Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

Similar documents
744A SprAyer Control U S e r M A n U A l

844-E Sprayer Control. Installation, Programming and Operating

Assisted Steering Hydraulic Installation Manual for Vehicle Kit Number Fits Only AGCO Gleaner R62/R65 (after S/N 66000) and R72/R75 (after

SENTRY ISOBUS Tip Flow Monitor. Software Version 1.00

834 Sprayer Control L2.12 User Guide R1

Matrix Pro GS. Setup Guide. For use with software version 3.0x. TeeJet Aabybro Mølhavevej 2 DK 9440 Aabybro Danmark

RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

unipilot Installation Manual Assisted Steering Kit Number

Reference Manual /12

Case IH 3320, 3330, and Booms AutoBoom Installation Manual. P/N Rev B 06/15

MONITORS AND CONTROLS. Liquid filled 100 PSI pressure gauge.

S P R AY E R VA L V E S AND C O N T ROL S C AT A L OG

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Installation Instructions Diesel Nitrous System (#82028)

GPS AutoSteer System Installation Manual

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

CONTENTS 1.0 INTRODUCTION SAFETY... 5

Buhler Versatile 23XX/24XX, Versatile 9X80, and New Holland Versatile 9X8X SmarTrax MD Installation Manual. P/N Rev A 04/16 E23635

DC Singledock Vehicle Wiring and Mounting Instruction

AutoBoom Installation Manual

IVTM Installation Manual

INSTALLATION AND OPERATION MANUAL FOR MCH-GPS17 GPS Compass and Ambient Temperature Gauge. NUTS (x3) 1 +12V TEMP SENSOR

GPS AutoSteer System Installation Manual

Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS2 with Servo Control

Installation Tips for your Remote Start system (for RS4LX>GMBP for GM vehicles)

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

GPS AutoSteer System Installation Manual

UNIVERSAL GAUGE WIRE HARNESS

JEEVES. JEEVES Installation Manual. Installation Manual The Easiest Do-It-Yourself Dumbwaiter on the Market

Massey Ferguson 76X0/ 86X0/8700 Series, AGCO DT-B Series, and Challenger MT6X5C/D/E Series - Steering Ready SmarTrax Installation Manual

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

EasyStart Installation Instructions for Dometic Family RV A/Cs

Installation Instructions

Spray Height Controller

GPS Steering System Installation Manual

Case IH Puma and New Holland T70X0/T7.XXX - Steering Ready SmarTrax Installation Manual. P/N Rev B 09/15 E20796

Single Nozzle Systems UNIVERSAL NOZZLE SYSTEM INSTRUCTIONS Part #'S 00-1XXXXX

ONBOARD AIR HOOKUP KIT

ARAG Modular Electric Valve Operating Instructions and Parts Manual

RS-110 Rainfall Sensor Installation Guide

Model 1100B CHG Terminator. Installation Instructions

150 PSI ILLUMINATED DASH PANEL GAUGE KIT

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

MODEL 1100 TURBINE FLOW METER

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

TC26-B Vehicle Sensor

ISIS Power Manual and Installation Guide Race Car Replicas- Superlite Coupe

GPS AutoSteer System Installation Manual

Installation Instructions

Overview of EIS Installation

CUMMINS 6.7L EXHAUST BRAKE PRXB EXHAUST BRAKE KIT FOR 2007½-2015 TRUCKS EQUIPPED WITH 6.7L CUMMINS ISB DIESEL ENGINES. C Kit C Kit

Installation Instructions

METROLOGIC INSTRUMENTS, INC. MX001 Industrial Control Interface Installation and User s Guide

AEROMOTIVE Part # and F-Body Fuel System Kit INSTALLATION INSTRUCTIONS

350/370Z System Instructions Part #

# and # FAST Fuel System Kits

Fitting Instructions: Street Triple from VIN and Street Triple R from VIN A

MODEL NO. UTL-60-7

INSTALLATION AND OPERATING MANUAL

PN: A. Reactive Steering Kit Installation Manual

Spray Height Controller

Spray Height Controller

ONBOARD AIR SYSTEM FOR ALL VEHICLES APPLICATIONS

User Guide. Digital Shipping Scale S150

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

GM ALLISON 6 SPEED LCT-1000/2000/2400 CO-PILOT Parts list

Fast Master Products, Inc. P.O. Box 654, Katy Texas Tel: (281) Fax: (281)

463 Arag High Pressure Controls OM

English. Fitting Instructions: Trophy and Trophy SE A of 12. Parts Supplied:

Nitro (4000 Series) Installation Manual NT04

Model 1100 Turbine Flow Meter

GPS AutoSteer System Installation Manual

665 Series Dispenser. Metering tip kit

MODEL NO. UTL Gallon 12 Volt Skid Mounted Utility Sprayer ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

Thank You. for purchasing an Edelbrock Nitrous Oxide Injection System. Please take the time to read and understand the following.

INSTALLATION AND OPERATING

User Manual SatStation Extreme Dock - Blue for IRIDIUM 9575

Installation Instructions. Part #65100

MSD 7AL-3, Ignition Control PN 7230

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Toro Sprayer Calibration Tool

Spray Height Controller

U L T I M A T E R A D A R / L A S E R D E F E N S E S Y S T E M

INSTRUCTIONS. #82044 Race Diesel Nitrous System

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

INSTALLATION AND OPERATING MANUAL

RECON ZONE BLOCKAGE AND FLOW MONITOR INSTALLATION MANUAL. Document revision: 1.2 Last revised: October 25, 2017

FLEXI-COIL 67 Series (1999+) Installation Manual FC1

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

#82044 Race Diesel Nitrous System

Components. Options Accessory Harness USB Charger. Quick Connector. Hook & Loop / Cable-ties. RFID Antenna. Module. Main Harness.

Challenger 60 & 70 Tow Series. Installation & User Manual

CS 550/150RC. Spreader Joystick Controller Installation Manual

General Information. Notations and Conventions. Compatibility Check. Kit Description. Call-Outs. Part Lists Great Plains Manufacturing, Inc.

Plus SABRE LIGHTBARS

Clutch Control. PN: November 2013 Rev E 1

U1 Battery Buddy DC-to-GO w/ RIGrunner 4005

Installation. Manual. OnTrac2+ GPS Assisted Steering System PN: A

Panel Mount Digital Tachometer Model

Transcription:

Sprayer Control Plumbing & Installation Manual for SprayLink Cable Installations Tank Jet Tank Shut-Off Diaphragm Pump Electric Ball s Transducer Strainer Relief Regulating

Copyrights 2012 TeeJet Technologies. All rights reserved. No part of this document or the computer programs described in it may be reproduced, copied, photocopied, translated, or reduced in any form or by any means, electronic or machine readable, recording or otherwise, without prior written consent from TeeJet Technologies. Trademarks Unless otherwise noted, all other brand or product names are trademarks or registered trademarks of their respective companies or organizations. Limitation of Liability TEEJET TECHNOLOGIES PROVIDES THIS MATERIAL AS IS WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESSED OR IMPLIED. NO COPYRIGHT LIABILITY OR PATENT IS ASSUMED. IN NO EVENT SHALL TEEJET TECHNOLOGIES BE LIABLE FOR ANY LOSS OF BUSINESS, LOSS OF PROFIT, LOSS OF USE OR DATA, INTERRUPTION OF BUSINESS, OR FOR INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OF ANY KIND, EVEN IF TEEJET TECHNOLOGIES HAS BEEN ADVISED OF SUCH DAMAGES ARISING FROM TEEJET TECHNOLOGIES SOFTWARE. Safety Information TeeJet Technologies is not responsible for damage or physical harm caused by failure to adhere to the following safety requirements. As the operator of the vehicle, you are responsible for its safe operation. Be sure that the area around the vehicle is clear of people and obstacles before and during engagement.

Plumbing & Installation Table of Contents Plumbing Diagrams 1 Mounting Sprayer Components 5 Regulator In Bypass Mode... 5 Regulator In Throttling Mode... 5 Flow Meter... 5 Boom Control s... 6 Transducer... 6 Speed Sensors 7 Options... 7 Magnet & Proximity Speed Sensor Installation... 7 Step 1: Location... 7 Step 2A: Installing The Magnetic Sensor... 7 Installing the Wheel Magnets... 8 Step 2B: Installing The Proximity Sensor... 9 Confirming Speed Sensor Installation... 10 Magnetic & Proximity Wheel Sensor... 10 Radar... 10 Mounting The Console 11 Console Step 1: Location... 11 Console Step 2: Mounting... 11 Electrical Connections 12 Connect Step 1: Power... 12 Connect Step 2: Sensors... 13 Connect Step 3: s... 14 Main Cable Wire Chart... 14 Connect Step 4: Console... 15 98-70005 R2 c

Sprayer Control System System Tests 16 Test Step 1: Test Console Power Up... 16 Test Step 2: Test Speed Sensor Installation... 16 Test Step 3: Test s Installation... 17 Test Step 4: Test Flow Meter Installation... 17 Test Step 5: Transducer Installation... 17 Machine Connector... 17 d www.teejet.com

Plumbing & Installation Plumbing Diagrams The following diagrams are shown as general guidelines to follow when plumbing TeeJet Sprayer control components. The type of pump used, type of valves used and location of other components can vary from sprayer to sprayer. It is important to ensure that if a pressure transducer is used that it is located as close to the spray tips as possible. Normally this is at the boom control valves. However, if a particular boom section is always used, the pressure transducer can be mounted on that particular boom section. If a flow meter is used, ensure that all of the flow going through the flow meter is directed to the spray tips. Make sure that proper distance is allowed on the inlet and outlet side of the flow meter (refer to the flow meter section of this manual). Figure 1-1: Bypass Plumbing Diagram, Flow Based System,Centrifugal Pump Electric Ball s Tank Jet Flow Meter Tank Shut-Off Strainer Regulating Centrifugal Pump Throttle Figure 1-2: Bypass Plumbing Diagram, Based System, Centrifugal Pump Tank Solenoid s Transducer Jet Tank Shut-Off Regulating Centrifugal Pump Strainer Throttle 98-70005 R2 1

Sprayer Control System Figure 1-3: Throttle Plumbing Diagram, Flow Based System, Diaphragm Pump Tank Jet Tank Shut-Off Diaphragm Pump Electric Ball s Strainer Relief Flow Meter Regulating Figure 1-4: Bypass Plumbing Diagram, Based System, Diaphragm Pump Tank Jet Tank Shut-Off Diaphragm Pump Electric Ball s Transducer Strainer Relief Regulating 2 www.teejet.com

Plumbing & Installation Figure 1-5: Throttle Plumbing Diagram, Flow Based System, Diaphragm Pump Tank Jet Tank Shut-Off Diaphragm Pump Electric Ball s Strainer Relief Regulating Flow Meter Bypass Control Figure 1-6: Throttle Plumbing Diagram, Based System, Diaphragm Pump Tank Jet Tank Shut-Off Diaphragm Pump Electric Ball s Transducer Strainer Relief Regulating Bypass Control 98-70005 R2 3

Sprayer Control System Figure 1-7: Throttling Plumbing Diagram, Flow Based System, Centrifugal Pump Tank Regulating Solenoid s Jet Flow Meter Tank Shut-Off Strainer Centrifugal Pump Throttle Figure 1-8: Throttling Plumbing Diagram, Based System, Centrifugal Pump Tank Electric Ball s Transducer Jet Regulating Tank Shut-Off Strainer Centrifugal Pump Throttle 4 www.teejet.com

Mounting Sprayer Components Regulator In Bypass Mode All pressure regulating valves for TeeJet control kits will be wired for use in a by-pass system. While plumbed in a by-pass mode, with the AUTO/MAN key in the MAN mode, the valve should close when the + key (switch) is pressed and open when the key (switch) is pressed. The pressure regulating valve can also be mounted in a throttle position as an alternative location. Refer to the plumbing diagrams in the plumbing section of this manual for differences between throttle and bypass plumbing. Regulator In Throttling Mode The pressure regulating valve can be located in the supply line before the boom control valves. This means that all of the flow going through the regulating valve is directed to the spray booms. If you choose this location, the control console will need to be properly programmed to reverse the polarity of the valve. This programming step can be found in the Programming and Operating Manual supplied with your console. When in throttling mode, with the sprayer control console in manual mode, the valve should open when the + key (switch) is pressed, and close when the key (switch) is pressed. Be sure to check this before plumbing the valve into the system. Flow Meter To ensure accurate readings, the flow meter (if used) must be mounted 10 to 12 (25-35 cm) from other pipe fittings on the inlet side of the flow meter and 5 to 7 (12-17 cm) on the exit side of the flow meter. Mount (preferably) in a vertical position with the flow going up with direction of flow arrow (if applicable) pointing toward the boom control valves. Refer to figure below. Be sure the flow meter is plumbed so that all liquid passing through it is routed to the booms and not back to the tank. When using three-way boom control valves, refer to Programming and Operating instruction manual of your sprayer controller for programming guidelines. Plumbing & Installation Figure 1-9: Regulator Figure 1-10: Flow Meter Mounting 5"-7" 12-17 cm 10"-12" 25-35 cm Flow Meter Figure 1-11: Flow Meter Examples Electric Ball s 98-70005 R2 5

Sprayer Control System Boom Control s The Boom Control s are connected in tandem and centered in front of the boom sections. See the Control Instruction Manual for mounting instructions. NOTE: If using a flow based (flow meter) control system, flow should not be bypassed back to the tank from the valves unless using three-way, constant pressure valves. All flow that goes through the flow meter should either be directed to the boom sections or dead head at the valves. If using three-way valves, refer to the instruction manual of the valves you are using for valve calibration instructions. Transducer The pressure transducer (if used) should be installed as close to the spray tips as possible. Normally this is at the boom control valve assembly. Refer to diagrams below. Mount the unit vertically on a short stand pipe to help protect the sensor. NOTE: drop, to some degree, is found in most plumbing systems. drop is created when there is any kind of restriction in the spray line reducing flow rate and is quite often produced between the boom control valve assembly and the spray tips. If one of the boom sections on the sprayer is always used, the pressure transducer can be installed on that particular boom section, therefore minimizing any potential pressure drops between the sensor and spray tips. If the pressure drop in your system is greater than 5 psi (0.3 bar), you should consider this as an alternative location for the pressure transducer. Check all components to make sure they are mounted securely to avoid excessive vibration. Figure 1-12: Boom Control s Examples Figure 1-13: Transducer Electric Ball s Transducer 6 www.teejet.com

Speed Sensors Options Magnetic Speed Sensor Plumbing & Installation Two magnets, Sensor with attached connector cable, and mounting hardware. Proximity Speed Sensor Radar Speed Sensor Proximity speed sensor with attached connector cable. Radar speed sensor and appropriate adapter cable (if ordered). Follow the instructions supplied with Radar Speed Sensor for installation. GPS Speed Sensor GPS speed sensor, GPS antenna and appropriate adapter cable (generic, Raven or Deutsch). Follow the instructions supplied with GPS Speed Sensor for installation. Matrix Pro Guidance System Built-in GPS supplies speed. Follow the instructions supplied with the Matrix Pro guidance system for installation. Magnet & Proximity Speed Sensor Installation Step 1: Location The speed sensor assembly should be installed on a non-driven wheel to avoid potential errors that are likely to occur from a slipping drive wheel. In case of a tractor mounted sprayer the speed sensor is usually mounted on one of the front wheels. In case of a trailed sprayer the sensor is usually mounted on one of the sprayer wheels. Step 2A: Installing The Magnetic Sensor The flat L bracket of the wheel speed sensor kit should be secured to a vertical member near the non-driven wheel. The round, right angle steel bracket is then secured to the flat bracket with the two U-bolts and necessary hardware provided. The round, right angle bracket is then used to secure the magnetic sensor mounting clamp. 98-70005 R2 7

Sprayer Control System Figure 1-14: Installing The Magnetic Sensor Sensor Flat L Bracket Sensor U-bolts Clamp Screw Sensor Clamp Steel Bracket Rim Magnet The magnetic sensor should be inserted into the mounting clamp and positioned to within 1/8 to 3/8 (3-10 mm) of the wheel magnet. Tighten the sensor clamp using the clamp screw. NOTE: Your installation will likely vary from the example. It may be necessary to customize the installation to accommodate your specific machine. The magnetic sensor must be mounted in-line with the magnets and positioned within 1/8 to 3/8 (3-10 mm) from each magnet as they pass the Sensor assembly. Installing the Wheel Magnets The two magnets must be spaced an equal distance around the wheel. Check for pre-drilled holes in the wheel rim. If pre-drilled holes are not available, lay out a pattern as shown in figure above and drill two 3/8 (10 mm) holes, locating them near the outer edge of the rim, if possible, and 180 from each other. Place the magnets into each of the two holes on the inside rim and securely fasten using the nuts and washers provided. 8 www.teejet.com

Plumbing & Installation Figure 1-15: Installing the Wheel Magnetics Step 2B: Installing The Proximity Sensor An optional proximity sensor is available to use in cases where space is limited or for drive shaft speed sensing. The proximity sensor will work by sensing any metal object. The proximity sensor must be mounted in-line with the bolts and positioned within 1/8 to 3/8 (3-10 mm) from each bolt as they pass the Sensor assembly. Secure the Proximity speed sensor to a bracket that is mounted on a vertical member near the non-driven wheel. NOTE: A mounting bracket is not included with a proximity speed sensor kit. You will need to fabricate a mounting bracket. This is usually accomplished using a flat piece of steel that is rigid enough to avoid vibration yet flexible enough to bend to position the sensor in the desired location. Figure 1-16: Installing The Proximity Sensor LED 98-70005 R2 9

Sprayer Control System The proximity sensor should be secured with two self tapping screws. The sensor bracket must be installed in such a way that excessive vibration is prevented. Otherwise false pulses can be detected by the sensor due to vibrations of the sensor itself. NOTE: Your installation will likely vary from the example. It may be necessary to customize the installation to accommodate your specific machine. Keep in mind that the bolts must be spaced an equal distance around the wheel (which is normally the case). Confirming Speed Sensor Installation NOTE: Control console must be powered on to confirm the speed sensor installation. If you have not yet installed the control console and connection to power, continue on with the installation and confirm speed installation during the testing procedures. Magnetic & Proximity Wheel Sensor After your wheel or proximity sensor is installed and once the control console is installed and powered up, you can test the speed sensor installation. Connect the wheel speed or proximity sensor to the main cable, and in turn connect the main cable to the control console. When the connection is made, rotate the wheel that is being used for the speed sensor. If using a proximity sensor, you will be sensing metal objects and not magnets. Each time a magnet (metal object for proximity sensor) passes the sensor a red LED (orange LED for proximity sensor) on the back of the sensor will light. The LCD display on the console will also indicate a speed as the sensor receives and sends electronic pulses. Figure 1-17: Magnetic & Proximity Wheel Sensor LED LED Radar If you are using a radar speed sensor it should be connected to the speed sensor connector on the main cable. An adapter cable will be necessary when using most radars and is available through your TeeJet dealer. The TeeJet control console will automatically sense if the speed sensor is a wheel speed, proximity type or radar type sensor during calibration. TeeJet control consoles are automatically adapted to most brands of radar speed sensors, provided that the appropriate adapter cable is used. If using a radar sensor, the control console will usually show some indication on the display during the calibration procedure. The indication may be different from console to console. Refer to the speed sensor calibration instructions in the Programming and Operating Manual for your console. 10 www.teejet.com

Plumbing & Installation Mounting The Console Console Step 1: Location Determine the best location for the control console in the cab or operator s compartment. Allow sufficient clearance, approximately 6 to 8 (15-20 cm) to accommodate for the Main Cable that will be connected to the connector on the right hand side of the console. Console Step 2: Mounting Mount the console to a firm support within the cab area, and secure using the slots provided on the top, back, or bottom of the Console. The mounting brackets included with the kit can provide angle adjustment if necessary. The slots in the Console will accept 1/4 (6 mm) bolts. Figure 1-18: Installing The Proximity Sensor 98-70005 R2 11

Sprayer Control System Electrical Connections Connect Step 1: Power Locate the power cable; it has a black connector on one end, and two battery terminal rings on the other. Extend the battery terminal ring end of this cable to the battery. NOTE: Some tractors use two 6 Volt batteries as a power source. Make sure there is a total of 12 Volts delivered to the controller by connecting to the (+) terminal on one battery and the (-) terminal on the other battery. Refer to the diagram below. Figure 1-19: Electrical Connections Reliable operation of the 844 Sprayer Control depends on a clean power supply. Ensure this by connecting the power cables directly to the battery and not to another power source. Connect the battery terminal rings to the battery posts, making sure that the positive (red) and negative (black) wires correspond with the polarity of the battery terminals. Connect the battery cable to the main cable by matching the appropriate connectors. NOTE: The power cable is designed to provide the simple addition of a remote master boom switch in a convenient location (i.e., on the throttle, gear shift, of floor switch). To install a remote boom switch, simply splice the switch into the brown wire in the power cable. The switch should be rated to handle the total current used by all boom section valves combined. If installed, the remote master switch will operate in series with the boom switches on the console. 12 www.teejet.com

Plumbing & Installation Connect Step 2: Sensors Now that you have the console installed you can begin connecting it to the other components of the system. Lay out the cables before installing the sprayer components to be sure the cables are long enough. If your installation requires longer cables, an extension that installs between the console and the standard main cable is available. If an exit hole had to be cut in the cab, be sure the edges are de-burred and protected to prevent damage to the cables. First match the connectors from the main cable to the mating connectors on the sensors (i.e. speed, flow, etc.) Next, determine the best cable routing to the sprayer control components on the sprayer. This could be along the flow line, mainframe of the sprayer, or wherever the cables can be conveniently secured. Avoid any situation where the cables may lay in puddles, or come in contact with extreme heat sources. WARNING: System Components should be mounted at least 3 feet (1 meter) from areas of excessive vibration (i.e., engines) to avoid high frequency interference. Now route the appropriate cable lead for each sensor to the sensor. Be sure to tie up any unused cable lengths to prevent possible damage. Connect the sensor leads from the main cable to the sensors. If both the flow meter and pressure transducer are not used simultaneously, there will be one extra connection on the sensor end cable. Simply tie this part of the cable back as it will not be used. Figure 1-20: Sensors Power Connection Shut-off Wires Refer to Connect Section for wire colors Speed Connection Connection Flow Connection Regulating Connection 98-70005 R2 13

Sprayer Control System Connect Step 3: s Repeat the procedure above with the cable leads to the Regulating and the Boom Control s. Refer to the chart below when attaching the boom section wires. This cable also includes two ground wires for ground connections and two wires for constant power (+12 VDC) connections if needed (i.e. for electric ball valves). Main Cable Wire Chart Description Wire Color Section 1 White Section 2 Brown Section 3 Green Section 4 Yellow Section 5 Gray Ground Green +12 VDC Red NOTE: Most TeeJet controls are designed to handle a maximum of 4 amps per boom section. T-tap connectors must be attached to the ground wires to connect them to the boom control valves, which should be evenly distributed across the two. The same procedure with the T-tap connectors should be followed for the constant power wires (if used). Figure 1-22: T-tap connectors Figure 1-21: s 1 2 3 4 5 1 2 3 T-tap connector Step A Step B Step C 14 www.teejet.com

Plumbing & Installation Figure 1-23: Wire Connections White Wires: Connected to the appropriate section wires from Main cable; see table above Green Red Black Wires: Connected to the green (ground) wires from Main cable Red Wires: Connected to the red (+12VDC) wires from the Main cable Connect Step 4: Console Now connect the main cable to the console. The connection is slotted so that it will connect in only one way. Simply rotate the connector until you feel the slots line up Then twist the locking ring of the connector onto the console connection to complete the connection. Figure 1-24: Locking Ring and Cable Connection Locking Ring Main Cable 98-70005 R2 15

Sprayer Control System System Tests Test Step 1: Test Console Power Up Make sure that the Main Cable is connected with the Console. Check if the Console starts up by pressing the appropriate ON key (refer to the Programming and Operating Manual of your console for instructions on turning the console on) of the Console. If the display shows information then the power to the Console is correctly connected. If the Console does not power up, check the Main Cable connection and check the connection at the battery. NOTE: Most TeeJet Sprayer Controls have an automatic power down feature. With the master boom switch in the off position, the console will automatically shut down after 10 minutes of no inputs. This prevents possible battery drainage. To turn the console off, refer to the Programming and Operating manual shipped with your console. WARNING: DO NOT SWITCH OFF THE CONSOLE BY REMOVING THE MAIN CABLE. Test Step 2: Test Speed Sensor Installation Rotate the wheel on which the speed sensor is installed. Each time a bolt (magnet) passes the sensor, an LED on the sensor will light up The display on the console will also indicate a speed as the bolts (magnets) pass the sensor or you can count the pulses when the Console has an auto speed calibration mode (see Programming and Operation Manual of the Console). If using a radar speed sensor, follow the instructions supplied with that unit. The only good test with a radar is to actually drive the vehicle with the radar installed and connected to determine if you are getting a speed signal. Figure 1-25: Speed Sensor LED LED 16 www.teejet.com

Plumbing & Installation Test Step 3: Test s Installation From the Console turn the Master switch and the Boom Section switches ON and OFF - one by one - and verify whether the valves open and close properly. The Master switch must be on for the individual boom switches to work correctly. The regulating valve can be tested by switching the Console to Manual mode. When the Master switch is ON, you can drive the regulating valve by pressing the + or the key. The + key should increase pressure and the key should decrease pressure. Test Step 4: Test Flow Meter Installation Warning: Perform those initial tests only with water (no chemicals)! Make sure that the flow meter pick-up sensor is mounted in the correct position. If using a standard turbine type flow meter the pickup sensor should be mounted in the hole closest to the arrow on the flow meter body. This hole is also deeper than the other one. To test the flow meter, with the control console powered on, activate the sprayer pump. Now turn on the individual spray boom switches that will be used during the test. Next toggle the Master switch to the on position. You should see spray start to come out of the spray tips. View your console display screen to see if the flow information is being recorded. It is also possible to activate the flow meter by blowing through the flow meter until you see the turbine turning in the flow meter body. You can test the flow signal also when the flow meter pickup sensor is not yet screwed into flow meter body. The sensor can be activated by bringing a piece of metal (e.g. screw driver) against the pickup. Test Step 5: Transducer Installation Make sure that the pressure sensor is securely mounted and the sensor lead for the pressure transducer has been plugged in. To test the pressure transducer, with the control console powered on, activate the sprayer pump. Now turn on the individual spray boom switches that will be used during the test. Next toggle the Master switch to the on position. You should see spray start to come out of the spray tips. View your console display screen to see if pressure information is being recorded. Figure 1-26: Male Pin Connector (console connector) Machine Connector The machine connector is a 28-pole Framatome connector with all necessary machine connections. The connector socket on the side plate has male pins, so the connector on the cable should have the matching female sockets. The functions of each pin are explained in the following table. 98-70005 R2 17

Sprayer Control System Pin Signal Remarks A Main Output to drive the Main if used (+12V when active) B Section 1 Output to drive the valve for section 1 C Section 2 Output to drive the valve for section 2 D Section 3 Output to drive the valve for section 3 E Section 4 Output to drive the valve for section 4 F Section 5 Output to drive the valve for section 5 G Section 6 Output to drive the valve for section 6 H Section 7 Output to drive the valve for section 7 J Section 8 Output to drive the valve for section 8. K Section 9 Output to drive the valve for section 9 L N/A Not Used M N/A Not Used N N/A Not Used P N/A Not Used R Flow Sensor Input for the flow sensor (active GND) S Sensor Input for the pressure sensor (0 to 20mA or 4 to 20mA) T Speed Sensor Input for the speed sensor (Active GND). Proximity or Radar type. U N/A Not Used V N/A Not Used W N/A Not Used X N/A Not Used Y N/A Not Used Z N/A Not Used a Reg. + Output with the plus signal for the regulating valve b Reg. - Output with the minus signal for the regulating valve c +12V Switched Input +12V Supply for Main valve and Boom section valve outputs d Ground (-) Supply GND e +12V supply +12V Supply for Console 18 www.teejet.com

S p r a y e r C o n t r o l Plumbing & Installation MANUAL Congratulations! And thank you for choosing a TeeJet Technologies advanced sprayer control system. With its proper installation and maintenance, you can enjoy many seasons of accurate and uniform spray application with fingertip convenience and ease of operation. Installation of your control system components will be covered in easy-to-follow, step-by-step instructions. WE RECOMMEND THAT YOU READ THESE INSTRUCTIONS COMPLETELY before attempting installation of your sprayer control system. The unit s performance will depend on it s proper installation, along with planned preventive maintenance of your entire sprayer. 1801 Business Park Drive Springfield, Illinois 62703 USA Tel: (217) 747-0235 Fax: (217) 753-8426 www.teejet.com 98-70005 R2 TeeJet Technologies 2012