P099-P0998-E.qxd 0..5 :5 AM Page 99 Directional Control Driver for Electric Cylinder Series LCF LJ LG LCF-5A 첸 LCF-5A5 첸 LTF Able to control the stroke with only / signals. LC Directional control driver like a solenoid valve LC8 LC7 LXF Able to set thrust arbitrarily. LXP LXS Thrust can be adjusted by adjustment trimmer. LC6첸 Able to control with only different types of input signals. LZ첸 LCF q Directional instruction w Thrust selection e Output / X첸 D-첸 Can be operated manually. E-MY Maintenance performance for wiring check has been improved. Product Specifications Model LCF-5A첸 VDC ± 0% Power supply Front side label color Input signal Selction of thrust Ambient temperature Ambient humidity Environment LCF-5A5첸 Max.. A Max.. A Gray Blue Photocoupler input VDC ±0% Max. 8 ma/point 00% or set value (Setting range 0 to 70% F.S.) +5 to 0 C 5 to 85% Rh (No condensation) Indoor (Direct sunlight should be avoided.) No corrosive gas, inflammable gas, oil mist or dust particle Display LED Mass POWER,,, 5 g 99 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-670-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com
Directional Control Driver for Electric Cylinder Series LCF RoHS How to Order Option LCF A A5 Power supply 5 VDC Applicable motor DC motor (Cylinder size ) DC motor (Cylinder size 5) 5AB Housing set (Connector set) Housing for CN,, (connector) & contact A (connector pin) are included as an accessory. B Nothing included. Cable for power supply terminal LCF C 0 Cable type Cable for CN power C supply terminal Cable length 0 0 m m Cable for control terminal LCF C 0 Cable type Cable for CN C control terminal Cable length 0 0 m m Cable for motor output terminal LCF C 0 Cable type Cable length Cable for CN motor C output terminal 0 05 m 5 m Housing set (Connector set) LCF C0 Housing for power supply terminal (Connector) Housing for control terminal (Connector) Housing for motor output terminal (Connector) Contact (Connector pin) 60 ± 5 Cable length 60 ± 5 60 ± 5 Cable length 60 ± 5 CN Control Table COM Common terminal Output Adjusted thrust Traveling direction 60 ± 5 Cable length 60 ± 5 pc. pc. pc. pcs. VHR-N: J.S.T. Mfg Co., Ltd. VHR-N: J.S.T. Mfg Co., Ltd. VHR-N: J.S.T. Mfg Co., Ltd. BVH-T-P.: J.S.T. Mfg Co., Ltd. CN Power Supply Table Do not apply repetitive bending or pulling stress to the cable. Wiring with repetitive bending or pullling stress to the cable will likely cause the cable to break. In the event of crimping the contact (connector pin) and wire, use the specified tools as well as the recommended cable. Crimping tool: YC-60R (J.S.T. Mfg Co., Ltd.) Pulling tool: EJ-NV (J.S.T. Mfg Co., Ltd.) Recommended cable connection (common for individual cable) AWG (0.5 mm ), Insulated wire O.D..7 to.0 mm with shield, Heat resistance is more than 80 C. Maximum cable length CN cable for power supply terminal m CN cable for control terminal m CN cable for motor output terminal 5 m Shield is attached with an optional cable for the LCF series. When grounding a shield, remove the sheath and use a metal U-crip or P-crip. 99 : Motor output : No motor output : Adjusted thrust : 00% thrust (Max. thrust) : (Retracted side) : B-PHASE (Extended side) FG Frame ground DC (+) Driver power supply (+ V) DC ( ) Driver power supply (0 V) Pin number Pin number Optional cable color Yellow/Green Brown Blue Optional cable color White Red Yellow Orange CN Motor Output Table Pin Optional number cable color OUTA Motor output A (Blue) Blue OUTB Motor output B (Red) Red Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-670-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com
Directional Control Driver for Electric Cylinder Series LCF Applicable Cylinder Table Cylinder part no. L Z - A - L Z 5 - A5 - Applicable directional control driver LCF-5A LCF-5A5 Dimensions 9 9 8.7 8 8.5.6 8.5 Mounting 5.5 CN control terminal M x 0.5 For protection grounding terminal mounting 78.6 86 x ø.6 For main body mounting Consider the cooling period, so that the operating temperature of main body should be within the range of specifications. Also, allow enough distance from each side of the main body, construction and the parts. Cooling should be considered, so the surface temperature of a heat sink should not be more than 50 C even though the temperature is within the operating range. 78.6 mm 57 5.5 (.5) () CN power supply terminal CN motor output terminal Protection grounding terminal Protection grounding Cross recessed bind screw M x pc. terminal Spring washer Nominal pc. related components Tooth lock washer (A) Nominal pc. Related components for mounting the protection grounding terminal are provided together with the product. LJ LG LTF LC LC7 LC8 LXF LXP LXS LC6 LZ LCF X D- E-MY How to Mount Mount the directional control driver vertically against the wall, using two mounting screw holes, so the front side (on which its adjustment trimmer and manual switch are located) is facing to an operator. Applicable mounting screw: M ( pcs.) [to be supplied by customer] How to mount a protection grounding terminal Cross recessed bind screw (Accessory) M x.6 Spring washer Nominal (Accessory) Crimping terminal 78.6 Tooth lock washer (A) (Accessory) Nominal Note) Crimping terminal and grounding cable are supplied by customer. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-670-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com x ø.6 995
Series LCF Wiring Example Single phase 00 VAC MCCB Noise filter MC CN power supply terminal Power supply VDC DC (+) DC ( ) Series LCF MC FG MCCB: Circuit breaker MC : Contactor Ry : Relay MC Ry Rated input VDC ±0% Max. 8 ma/point Blue Red Electric cylinder mounted motor Surge suppressor CN motor output terminal OUTA OUTB CN control terminal COM Ry Emergency stop signal For System Chart, refer to page 78. Do not short circuit the motor output terminal (CN). Excessive current will flow, and the directional control driver may become damaged. How to wire CN motor output terminal Warning CN power supply terminal There is no emergency stop function or power supply switch in the directional control driver. Please be sure to provide an emergency stop and power supply insulation (insulator) device as a total machine equipment, referencing the above wiring examples. Also, please be sure to turn off the power supply for the whole equipment prior to wiring the directional control driver. CN control terminal Heat sink side CN Power Supply Pin no. FG DC (+) DC ( ) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) Frame ground Driver power supply (+ V) Driver power supply (0 V) CN Motor Output Pin no. OUTA OUTB Motor output A (Blue wire) Motor output B (Red wire) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) 996 Heat sink side CN Control Pin no. COM Output Adjusted thrust Traveling direction Common terminal : Motor output : No motor output : Adjusted thrust : 00% thrust (Max. thrust) : (Retracted side) Note) : B-PHASE (Extended side) Note) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) Note) For the travelling direction (retracted, extended side), refer to the dimensions in page 980, 98, 986 and 987. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-670-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com
Directional Control Driver for Electric Cylinder Series LCF Description of Each Part and its Category Description Details Trimmer Thrust adjustment trimmer Thrust changes through adjustment. POWER Light illuminates when power is supplied. Indicator light Light illuminates by command. (Travelling to the retracted side when illuminated) Light illuminates when turning. (No motor output is generated when illuminated.) LJ LG Light illuminates by command. (Thrust set by the thrust adjustment trimmer, when illuminated, will be outputted.) LTF Manual switch command while pressing (Travelling to the retracted side) command while pressing (Motor output will be generated.) command while pressing (Thrust set by the thrust adjustment trimmer will be outputted.) LC LC7 LC8 Timing Chart Warning. Do not operate or adjust settings with wet hands. You may experience an electric shock.. When operating the manual switch, make sure that your hands do not come in contact, or is caught between the workpiece. Otherwise you may become injured.. Do not press the manual switch with sharp objects, as the manual switch may be damaged.. Do not touch the directional control driver's heat sink. It will be very hot while turned on, so operate after you have checked that it has become cold.. Adjust the thrust adjustment trimmer under the conditions below. ) Adjust so that the pressure applied to the thrust adjustment trimmer remain below.9 N. ) The adjustment section of the thrust adjustment trimmer should be below 68.6 mn m. LXF LXP LXS LC6 LZ LCF X D- E-MY (Extended side) Note) 00% CN Control Pin no. COM Output Adjusted thrust Traveling direction Common terminal : Motor output : No motor output : Adjusted thrust : 00% thrust (Max. thrust) : (Retracted side) Note) : B-PHASE (Extended side) Note) Housing: VHR-N (J.S.T. Mfg Co., Ltd.) Contact: BVH-T-P. (J.S.T. Mfg Co., Ltd.) Note) For the travelling direction (retracted, extended side), refer to the dimensions in page 980, 98, 986 and 987. Thrust 0% (Retracted side) Note) 00% Note) For the travelling direction (retracted, extended side), refer to the dimensions in page 980, 98, 986 and 987. Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-670-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com 997
Directional Control Driver Specific Product Precautions Be sure to read before handling. External force (Manual or spring loaded) Thrust on Design and Operation. If an electric cylinder with DC motor should be rotated by the larger external force than the generated thrust, the reverse inrush voltage generated may cause adverse effects on the electric cylinders directional control driver and result in malfunction or damage to the product. Example) Do not push or pull a cylinder rod, applying a larger load or external force than the generated thrust. (Please use caution if the generated thrust should be switched over between a high thrust and a low thrust.) LCF Do not use this product by stopping it with a load or external force. (control operation) LCF Command an operation in the reverse direction only after a cylinder rod stopped completely. LCF Do not operate a cylinder rod with an external force when the electric cylinder directional control driver is turned off or output is in the off state. (If a cylinder rod needs to be moved manually for the purpose of adjustment, etc., be sure to remove the CN motor output terminal beforehand.) LCF LCF 998 Courtesy of Steven Engineering, Inc.-0 Ryan Way, South San Francisco, CA 9080-670-Main Office: (650) 588-900-Outside Local Area: (800) 58-900-www.stevenengineering.com