THE CONTROLLED ELECTRIC DRIVE OF THE AUTOMATIC COOLING SYSTEM OF THE ENGINE ROOM ON A VESSEL

Similar documents
Methods of reducing power losses in distribution systems

Grounding systems for power supply facilities

Modeling and Simulation of Linear Two - DOF Vehicle Handling Stability

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

The Modeling and Simulation of DC Traction Power Supply Network for Urban Rail Transit Based on Simulink

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

E-15 Uninterruptible Power Systems (UPS)

Figure1: Kone EcoDisc electric elevator drive [2]

DIRECT TORQUE CONTROL OF A THREE PHASE INDUCTION MOTOR USING HYBRID CONTROLLER. RAJESHWARI JADI (Reg.No: M070105EE)

Low Speed Control Enhancement for 3-phase AC Induction Machine by Using Voltage/ Frequency Technique

Hardware Design of Brushless DC Motor System Based on DSP28335

Fabrication and Automation of Solvent less Packaging Machine

Simulation of Pressure Variation in Hydraulic circuit with & without Hydraulic Accumulator in MATLAB-Simhydraulics

Researches regarding a pressure pulse generator as a segment of model for a weighing in motion system

3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015)

Performance Analysis of Transmission Line system under Unsymmetrical Faults with UPFC

Development of a PID Controlled Arduino-Based Stabiliser

Universal Fluid Power Trainer (UFPT)

Torque Management Strategy of Pure Electric Vehicle Based On Fuzzy Control

Inverted Pendulum Control: an Overview

A new approach on the upgrade of energetic system based on green energy. A complex comparative analysis of the EEDI and EEOI

Research and Design on Electric Control System of Elevator Tower for Safety Devices Yuan Xiao 1, a, Jianping Ye 2,b, Lijun E 1, Ruomeng Chen 1

Multi-axial fatigue life assessment of high speed car body based on PDMR method

Study on the Servo Drive of PM-LSM to Be Used in Parallel Synchronous Drive

Simulation of Dynamics of System with Hydraulic Lines and Linear Hydraulic Motor with Mass Load

A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

Using MATLAB/ Simulink in the designing of Undergraduate Electric Machinery Courses

COMPARISON OF ENERGY EFFICIENCY DETERMINATION METHODS FOR THE INDUCTION MOTORS

Kinematic Analysis of the Slider-Crank Mechanism in Automated Vibration Sausage Feeder

Design control system of auto air remaining machine based on programmable logic controller in the automotive manufacturing industry

Design of Damping Base and Dynamic Analysis of Whole Vehicle Transportation based on Filtered White-Noise GongXue Zhang1,a and Ning Chen2,b,*

International Journal of Advance Research in Engineering, Science & Technology

ISSN: X Tikrit Journal of Engineering Sciences available online at:

Universal Fluid Power Trainer (UFPT)

Modeling and Simulation of A Bldc Motor By Using Matlab/Simulation Tool

International Journal of Advance Research in Engineering, Science & Technology. Comparative Analysis of DTC & FOC of Induction Motor

International Journal of Advance Research in Engineering, Science & Technology

The Application of Simulink for Vibration Simulation of Suspension Dual-mass System

Example application for an supply air control with recirculated air addition. HVAC Application Note 3

Fuji Electric s Latest High Functionality Temperature Controllers PXH, PXG and PXR, and Examples of their Application

The gelsluice, an innovative idea for the present sluice structures

Numerical Investigation of Diesel Engine Characteristics During Control System Development

Experimental research of variable rotation speed ICE-based electric power station

UNIT 6: BATTERIES, UPS AND CABLES

TRANSMISSION COMPUTATIONAL MODEL IN SIMULINK

Integrated Monitoring System Design of Hybrid Aircompressors

E-15 Uninterruptible Power Systems (UPS)

A DIGITAL CONTROLLING SCHEME OF A THREE PHASE BLDM DRIVE FOR FOUR QUADRANT OPERATION. Sindhu BM* 1

Asian Journal on Energy and Environment ISSN Available online at

Software for optimal selection of places for installation of balancing devices in 0,4 kv electric power systems loaded with electric motors

Computer Aided Transient Stability Analysis

Bond Graph Modeling and Simulation Analysis of the Electro-Hydraulic Actuator in Non-Load Condition

Backup Generation Application

ENERGY CONSERVATION IN AUTOMATIC FLUID FLOW CONTROL USING VARIABLE FREQUENCY DRIVE

Airpax Dimensions, Inc.

A Relationship between Tyre Pressure and Rolling Resistance Force under Different Vehicle Speed

Registration of the diagnostic signals of the starting system for selected faults

INDUCTION motors are widely used in various industries

Control and Simulation of Semi-Active Suspension System using PID Controller for Automobiles under LABVIEW Simulink

Load Frequency Control of a Two Area Power System with Electric Vehicle and PI Controller

World Academy of Science, Engineering and Technology International Journal of Mechanical and Mechatronics Engineering Vol:11, No:3, 2017

Applications of Frequency Conversion Technology in Aircompressor

Perodua Myvi engine fuel consumption map and fuel economy vehicle simulation on the drive cycles based on Malaysian roads

ANFIS CONTROL OF ENERGY CONTROL CENTER FOR DISTRIBUTED WIND AND SOLAR GENERATORS USING MULTI-AGENT SYSTEM

Power Switching Principles

Paralleling Equipment

Design and Implementation of Reactive Power with Multi Mode Control for Solar Photovoltaic Inverter in Low Voltage Distribution System

Basics of Paralleling

International Conference on Advances in Energy and Environmental Science (ICAEES 2015)

Study on Braking Energy Recovery of Four Wheel Drive Electric Vehicle Based on Driving Intention Recognition

Examples of Electric Drive Solutions and Applied Technologies

Excitation systems for high power synchronous generators with redundant configurations

Intelligent Sprinkler Control System

Conceptual design of planetary gearbox system for constant generator speed in hydro power plant

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

Signature of the candidate. The above candidate has carried out research for the Masters Dissertation under my supervision.

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

Power Quality and Power Interruption Enhancement by Universal Power Quality Conditioning System with Storage Device

Design of Active and Reactive Power Control of Grid Tied Photovoltaics

ABB June 19, Slide 1

Tooth contact analysis of spur gears. Part 2- Analysis of modified gears

The gelsluice, an innovative idea for the present sluice structures

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

The Levitation Control Simulation of Maglev Bogie Based on Virtual Prototyping Platform and Matlab

Design and Simulation of a Sun Tracking Solar Power System

A Simulation Model of the Automotive Power System Based on the Finite State Machine

Open Access The New Structure Design and Simulation of Preventing Electric Shock Multi-Jacks Socket

Modelling and Analysis of Thyristor Controlled Series Capacitor using Matlab/Simulink

Technical News Bulletin

UPS Wizard User s Manual

Development of Small-capacity OFF-LINE UPS

Available online at ScienceDirect. Procedia Engineering 129 (2015 ) International Conference on Industrial Engineering

NOVEL MODULAR MULTIPLE-INPUT BIDIRECTIONAL DC DC POWER CONVERTER (MIPC) FOR HEV/FCV APPLICATION

Task By Course 7.1D This task is covered for engineers in the Leadership and Managerial Skills course

DYNAMIC BRAKES FOR DC MOTOR FED ELECTRIC VEHICLES

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Transient Analyses of a Shore-to-Ship Connection System

INVESTIGATION OF DYNAMIC BRAKING OF ELECTRIC VEHICLES POWERED BY PERMANENT MAGNET DC MOTOR

MODELING OF A MICROTURBINE WITH PMSM GENERATOR USING MATRIX CONVERTER TECHNIQUE FOR GRID INTERCONNECTION SYSTEM

Simscape Getting Started Guide. R2014a

Transcription:

THE CONTROLLED ELECTRIC DRIVE OF THE AUTOMATIC COOLING SYSTEM OF THE ENGINE ROOM ON A VESSEL Dennis V. Bevz 1,*, Lubov A. Payuk 1, and Nataliya A. Voronina 1 1 Tomsk Polytechnic University, 634050 Tomsk, Russia Abstract. Development of an automatic cooling system control by the Zelio Logic controller. Development of the simulation model of the openloop system frequency inverter asynchrous motor with IRcompensation in Matlab Simulink. Analysis of the transient characteristics = f(t), M = f(t) at the start of the asynchrous motor. 1 Introduction The Engine room it is a room on board designed to accommodate machines and mechanisms for its moving [1]. In this room there are: the central control post, which derived all automation systems, control and alarm systems main engine, which rotates the rowing screw; electric motors, intended to generate electricity for lighting, heating, operation of various devices and mechanisms; pumps for supplying oil, liquid fuel, cooling water; separators intended for clarification fuel and oil from impurity; compressors, which compress air supplied for engines starting; steam boiler intended for heating, heating of liquid cargo, for techlogical needs. The engine room is presented in figure 1. The ventilation system of the engine room has two main objectives: to provide such an environment that will allow machines and mechanisms work reliably; to provide comfortable working conditions for staff. Heat that is emitted from the engine and other mechanisms of the machine room, absorbed by the surface of the engine room. Part of the heat transferred to the atmosphere or water through the hull. The remaining heat has to be removed by the cooling system. Place the input of outside air into the engine room should be located as far away from heat sources and as low as possible. Since heat causes the air to rise upwards, the air outlet should be done at the highest point of the engine room. * Corresponding author: d.v.bevz@mail.ru The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/).

Fig. 1. The engine room of a vessel. 2 Development of automatic control of the cooling system A functional diagram of automatic ventilation system is presented in figure 2 [2]. Three-phase network 380 V AC QF Start / Stop FC1 Failure M1 PLC Zelio Logic Temperature sensor Start / Stop Failure FC2 M2 Fig. 2. Functional diagram of automatic cooling system: QF the automatic circuit breaker, FC1 the main frequency inverter, FC2 the reserve frequency inverter, M1 the main asynchrous motor, M2 the reserve asynchrous motor PLC the programmable logic controller Zelio Logic of Schneider Electric. This system has two asynchrous motors. The first motor is main and the second motor is reserve. The temperature sensor has analog output in the range 0...10V which corresponds to a temperature range from 0 to 100 degrees Celsius. Analog output of temperature sensor connects to analog input of PLC. When the temperature rises exceeds 30 degrees Celsius PLC generates a start signal which comes from the digital output of the controller to the digital input of the first frequency inverter, then the main asynchrous motor is started and ventilation process is begins. Ventilation continues until the temperature of 20 degrees Celsius and then the PCL generates stop signal to the first inverter. In case of a malfunction of the main frequency inverter a fault signal is entered to the PLC digital input. The controller sends a stop signal to the first frequency inverter and a start signal to the second frequency inverter. If the temperature during the operation of the main asynchrous motor exceeds the preset critical value equals 40 degrees Celsius the controller will generate start signal to the reserve frequency inverter and then the reserve asynchrous motor is started. The standby motor is operated together with the main motor for a predetermined time interval. If after that time interval the temperature does t 2

decrease alarm is triggered. The developed algorithm [3] that explains the operations of automatic cooling system is presented in figure 3. Start t>30 Failure of FC1 M1 starting M2starting Failure of FC2 t>20 t>40 M1 and M2 staring 10 minutes t>40 Alarm Fig. 3. The algorithm of the operation of the automatic cooling system. The algorithm is written for the controller in the functional block diagram language. The exterior of the software window of the controller with algorithm [4] is shown in Fig. 4. The developed algorithm provides work of the system of cooling in 3 modes: 1. start the main motor when the temperature exceeds the set value; 2. start the backup motor if there is an accident at the first frequency inverter and the temperature exceeds the set value; 3. operation of both motors for a predetermined time interval. End Fig. 4. The exterior of the software window of the PLC. 3

3 Development of a simulation model of the open-loop system frequency inverter asynchrous motor with IRcompensation To control the speed of the electric drive is used scalar control law U / f = const. The simulation model of the open-loop system frequency inverter asynchrous motor with IR-compensation is created in Matlab Simulink 2012 and presented in figure 5 [5]. Fig. 5. The simulation model of the open-loop system frequency inverter asynchrous motor with IR-compensation. Block Lookup Table forms the required relationship of the scalar control between the frequency and voltage [6, 7]. It sets the received frequency regulation law. The control signal is entered to the direct coordinate converter (block subsystem 2). Three sine wave control voltages U1уА, U1уB, U1уС which are shifted relative to each other at an angle ±2*pi/3 with amplitudes proportional to the control voltage are formed at the output of the converter. The signals U1уА, U1уB, U1уС form phase output voltage of the automous voltage (block subsystem). The transient characteristics of speed and torque are presented in figure 6. rad/s 350 300 250 200 150 100 50 = f(t) transient period= 0,41 s 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 rad/s t s М N*m 250 200 150 =f(t) 100 50 Мs = 36,4 N*m 0-50 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Fig. 6. The transient characteristics = f(t), M = f(t). t s 4

4 Conclusion The designed automatic cooling system of the engine room on a vessel has a high reliability, is simple in service and ecomic: 1. the system has two asynchrous motors one of them is main motor and ather one is backup motor. The control of the asynchrous motors is provided by the programmable logic controller Zelio Logic depending on the signal from the tempearture sensor and the faulire signal from frequency inverters; 2. start and stop of the asynchrous machines are relized by the frequency inverters, which allow to relize smooth start of the motors. It leads to reduction of starting currents and therefore increases life cycle of the asynchrous motors. Also, use of the frequency inverter leads to saving of electricity. References 1. N. F. Emelyav, Design, construction and elements of the theory of vessel (Dalrybvtuz, Vladivostok, 2002) [in Russia] 2. М.P. Belov, А.D. Novikov, L.N. Rassudov, Automatic electric drive of industrial machinery and techlogical complexes (Academa, Moscow, 2007) [in Russia] 3. Е.P. Ugrumov, Digital circuitry, (BHV-Petersburg, St. Petersburg, 2007) [in Russia] 4. R. Coris, X. Schmidt-Walter, Reference circuit design engineer (Techsphere, Moscow, 2008) [in Russia] 5. L.S. Udut, O.P. Maltseva, N.V. Koyain, Asynchrous frequency controlled electric drive (Publisher of Tomsk Polytechnic University, Tomsk, 2009) [in Russia] 6. I.V. Chernyh., Simulation of electrical devices in MATLAB, SimPowerSystems and Simulink (Piter, St. Petersburg, 2007) [in Russia] 7. L. Payuk, N. Voronina, S. Korepav, O. Galtseva, N. Nataliva, MATEC Web of Conf. 79, 01060 (2016) 5