Test. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder Answer:

Similar documents
ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (PRODUCT CODE: SAP 20B)

SAP E & C ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (FOR ITI) (PRODUCT CODE: SAP 20B-I)

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS. This work covers part of outcome 3 of the Edexcel standard module:

Actuators and directional control valves

Pneumatic Systems. Module 3: Logic Operations in Electropneumatics. IAT Curriculum Unit PREPARED BY. August 2008

Input, Control and Processing elements

The CASCADE Method. IA Cascade Method

HYDROMODEL-200. Implements and controls hydraulic and electro-hydraulic circuits. Transparent Hydraulics - Electro-hydraulics

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Multi Processing Station with Oven 24V

ME 360 Test #3 Spring 08 5/5/08. Closed book, closed notes portion of test. Total of 25 out of 100 points for questions #1 to #6.

G1/8-3/2-Way Valves - Series K9

FRL unit consist of Filterations, Regulators and Lubricator unit.

[You may download this article at: ]

DISCUSSION OF FUNDAMENTALS. A hydraulic system can be controlled either manually or automatically:

Function Description Of Roll-over Bar

Electrohydraulics Basic Level Textbook TP 601

Project Manual Industrial Hydraulics

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Basic Machine Interface Options

The pneumatic circuit and parts' list needed to perform this operation are shown by Figure C.1.

Subject: Pneumatic Training Kit with portable Air Compressor

Function description of roll-over bar

Special valves. Logic components AND/OR Timer 2/2 way screw-in valves Miniature screw-in pressure regulators Relief valves

MINIVALVES, MECHANICALLY AND HAND OPERATED SERIES VME

PNEUMATIC & HYDRAULIC SYSTEMS

Z1 B1 B2 Z2 B3 B4. Steuerteil + 24 V. Leistungsteil K1 K2 K1 K2. Practice for Professionals Electropneumatics Trainee s manual. Version 1.

Sorting Line with Detection 24V

Cambridge International Examinations Cambridge International General Certificate of Secondary Education

Module 5: Valves. CDX Diesel Hydraulics. Terms and Definitions. Categories of Valves. Types of Pressure Control Valves

Projekthandbuch. Project Manual Industriehydraulik. Industrial Hydraulics RE 00846/ Trainee's manual. Schülerhandbuch

Overview. References TEST SPECIFICATION FORT WORTH, TEXAS TROTTER CONTROLS REPORT X TS-0005 A MODEL ORDER TITLE BY CHK D. Tests

5/2-way monostable/bistable - 5/3 CC, CO, CP With outlets on the body - For individual or manifold assembly Size 10,5 mm

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Electro Pneumatic WorkStation Scientech 2470

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

Personal Restraint Hydraulic Lock "LE" for passenger restraint systems

Valves and Solenoid valves Series E 2/

Level 7 Post Graduate Diploma in Engineering Mechatronics

Festo Modular Production System (MPS)

BASIC PNEUMATIC & ELECTROPNEUMATIC TRAINING SYSTEM

Suggested list for the Hydraulic and Pneumatic lab Instruments Mechatronics Engineering Department School of Applied Technical Science

Introduction. Pre-Lab

I) Clamping the work piece II) Drilling the work piece. III) Unclamping the work piece. 10

2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA

: Automation Laboratory 1

Courseware Sample F0

Technical Bulletin AA 304. Central Locking System. m.y. 97

Ch 4 Motor Control Devices

INTEGRATED ELEMENTS. 1. FLIP-FLOP VALVES (pneumatic) ORDER CODIFICATION : AZ100354

Fluid Power Systems: Hydraulics and Pneumatics

Chapter 19. Applying Pneumatic Power. Typical Circuits and Systems

Learning System for Automation and Communications. Electropneumatics. Workbook Basic Level S1 K1 K1 Y1

Basic Hydraulics. Module 2: Actuators and directional control valves. Curriculum Development Unit PREPARED BY. August 2013

TWO HAND NON-TIE-DOWN CONTROLS SC SERIES

BG45 BG65S BG75 Axial Parallel Axial Parallel Axial Parallel CASM-32 (LS/BS/BN) X X CASM-40 (LS/BS/BN) X X X X CASM-63 (LS/BN/BF) X X

. Control unit (N53) The roll-over bar control unit is located on the tunnel below the rear seat.

ATM 322 PNEUMATICS MODULE 4

Flow sharing control block in sandwich plate design M7-25

INSTRUCTION MANUAL ENGINE IDLER MODEL # VOLTGAE MONITOR MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Engine-specific faults and their remedy are given in the operating manual of the engine manufacturer. Fault Possible cause Rectification

TAILOR MADE METAL FABRICATIONS LTD. VEHICLE ACCESS CONTROL BARRIER (VAC B)

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

Electro Pneumatic Workbench Scientech 2470

Electropneumatics Basic Level Set of Overhead Transparencies TP 201

Engineering Science: Pneumatics ENGINEERING SCIENCE. Pneumatic Systems

Control/Dimming. Design / DELTA line 2/8. Design / DELTA vita 3/9. Design / DELTA miro 4/8

Process switches and PLC circuits

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

PNEUMATE-200 Your mate in Pneumatics!

Industrial Pneumatic Systems Syllabus [Detailed]

Installation, Operation & Maintenance Manual Control Panels for Automatic Self-Cleaning Strainers Model 596 and Model 2596

O500LE & O500RF OVERVIEW OF READING MB PNEUMATIC DIAGRAMS AND PORT IDENTIFICATION. DaimlerChrysler Australia / Pacific Service & Parts CV

PREHEATER BYPASS SYSTEMS

Maintenance Guide AZTEC BNF-2000 BILL ACCEPTOR PRIMARY COMPONENT PARTS

2.11. Limit Switches. Contents Description. Special Purpose Limit Switches. Special Purpose Limit Switches

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

CURRICULUM BOSCH-REXROTH (CENTRE OF EXCELLENCE) GANPAT UNIVERSITY

Coating systems. Subject to change. Krautzberger GmbH /

LECTURE 15 TO 17 DIRECTIONAL CONTROL VALVES FREQUENTLY ASKED QUESTIONS

SOFT TOUCH A NEW STANDARD FUNCTION FOR UNITROL SOLUTION

HYDROTRAINER-200 Hydraulics - Electro-hydraulics

Series 3 valves are equipped with a manual override which allows a stable operation and they can use Series U or G solenoids (22x22).



Common wiring modules can be connected by fieldbus, multi-pole or common earth/neutral modules.

FLUID POWER P&IDs. IDENTIFY the symbols used on engineering fluid power drawings for the following components:

Front panel valves SV

TRESHOLD SENSORS LOGIC PNEUMATIC COUNTERS TIMERS VALVES

Modern Industrial Pneumatics. Design and Troubleshooting Industrial Pneumatics PN111 PN121

White paper: Pneumatics or electrics important criteria when choosing technology

Lesson 5: Directional Control Valves

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

Thin-line. Weld Heads

Air. Time delay. Figure 60. We can change the length of a delay by changing the size of the reservoir or adjusting the restrictor.

SUMMARY KIT PNEUMATIC MOTION

Syslog Technologies Innovative Thoughts

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3

Model CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"

Transcription:

Test This test allows you to establish whether your basic knowledge of pneumatic controls is sufficient for you to attend the advanced course P or whether you should attend the basic level course P. The test is designed to be completed quickly answers are multiple choice and do not require writing of words or sentences. You will find the correct answers in the Solutions sheet document.. Selecting a cylinder You have to select a pneumatic cylinder for installation in a machine. It must be able to exert a force of 00 N (approx. 0 kg) during its forward stroke. The return stroke is initiated by external force from the machine. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder. Setting the advancing speed The piston rod of the cylinder shown extends too quickly (motion to the right). You have to reduce the advancing speed. At which of the two one-way flow control valves would it be preferable to change the setting? A. One-way flow control valve B. One-way flow control valve 3. Selecting a valve A double-acting cylinder operates in a pneumatic system. The piston moves only to the forward or retracted end position (mechanical stop). Intermediate positions are not required. Which final control element (valve) should be used in this case? A. /-way valve B. 3/- way valve C. 5/- way valve D. 4/- way valve E. 4/3- way valve 4. Workpiece-clamping cylinder You have to select a cylinder / final control element combination for a workpiece-clamping cylinder. What overall behavior makes sense for this application? A. Bistable, retentive behavior, valve (final control element) without spring return B. Monostable, non-retentive behavior, valve (final control element) with spring return

5. Safe motion to end position A pneumatic cylinder operates in a production system. The sequence requires that the piston safely reaches its forward end position. Which pneumatic element would you use to ensure this? A. Timer (time delay valve, time relay ) B. Limit switch C. Pressure element (pressure sequence valve, electrical pressure switch) D. One-way flow control valve E. Shuttle valve (OR element) 6. Recognizing symbols You have installed valves requiring external lubrication into a previously unlubricated pneumatic control. A B C aaasa A Which of the valve combinations must you now install? D E 7. Recognizing valves by the port identification You have removed the valve shown from a control and want to replace it. What type of valve is it? A. 3/-way valve, pneumatically actuated on both sides B. 4/-way valve, pneumatically actuated, spring return C. 5/-way valve, pneumatically actuated, spring return D. 5/-way valve, pneumatically actuated on both sides E. 4/-way valve, solenoid-actuated

8. Way-valve designs Which type of valve is shown here? A. 5/-way valve (double pilot valve), suspended disk type B. 3/-way valve, ball poppet type C. 4/3-way valve, rotary slide type D. 5/-way valve (double pilot valve), slide valve type E. 3/-way valve, poppet type 9. Selecting a start pushbutton A system with multiple pneumatic cylinders is purely pneumatic. No electrical devices are installed. You have to install a suitable START pushbutton. What type of valve would you select as the start pushbutton? A. 3/-way valve, manually operated, normally closed B. 4/-way valve, manually operated, bistable C. 3/-way valve, manually operated, normally open D. /-way valve E. Dual-pressure valve 0. Selecting a valve You have to set up a pneumatic control. It must be possible for cylinder motion to be triggered by two different sensors at two different locations. Which additional valve must be installed? A B C D E

. Analyzing a simple circuit diagram The figure shows a simple electrical circuit comprising a Lamp H and the two switches S and S. Evaluate the following statements: +4 V S S H 0V Lamp H illuminates when Correct Incorrect... Switch S is operated.... Switch S is operated.... Both Switch S and S are operated.... Neither Switch S and S is operated. Mark your answers with a cross X in the appropriate column.. Selecting a valve combination A B C In a pneumatic control, the cylinder rod of a cylinder is only to extend after a delay of 0 seconds after signal input. 3 3 Which of the valve combinations shown must you install? D E 3

3. Detecting faults in a circuit diagram with one cylinder Documentation errors often cause time-consuming troubleshooting during commissioning. The circuit diagram shows the sequence for a simple control. Cylinder A should extend after actuation of S0 AND S, and return motion is controlled by S. Which of the following statements is correct? V A. Signal element S must provide a signal when cylinder A has reached the forward end position (right). For this reason, the position of S must be indicated by a mark on the front of the cylinder. B. The position of signal element S is incorrectly shown in the retracted position (left). S0 4 C. S0 must be mounted in the retracted position and should therefore also be designated there. D. The signal from S must act on the control side 4 and not on. E. The type of actuation Roller, mechanical for S is incorrect. 3 V /3 4 S 3 A 5 3 S S 3