FULL SWEEP STEPPER MOTOR INSTRUMENT KIT INSTRUCTION MANUAL 1969,REDLINE, 2020 SERIES

Similar documents
NEW VINTAGE INSTRUMENT AND GAUGE KIT INSTALLATION INSTRUCTIONS

NEW VINTAGE INSTRUMENT AND GAUGE KIT INSTALLATION INSTRUCTIONS 3-1 INSTRUMENT KIT REV

NEW VINTAGE INSTRUMENT AND GAUGE KIT INSTALLATION INSTRUCTIONS 3-1 INSTRUMENT KITS SPEEDO/TACH KITS REV

NEW VINTAGE INSTRUMENT AND GAUGE KIT INSTALLATION INSTRUCTIONS 3-1 INSTRUMENT KITS SPEEDO/TACH KITS 3-3/8 STUDDED SPEEDOMETERS REV.

PHOENIX TACHOMETER WITH OLED DISPLAY

MECHANICAL SPEEDOMETER KITS

NEW VINTAGE INSTRUMENT AND GAUGE KIT INSTALLATION INSTRUCTIONS GEN II BACKLIT INSTRUMENT KITS

INSTALLATION GUIDE Six Gauge Universal Digital Dash Panel Part Number: DP10002

INSTALLATION GUIDE Multi-Gauge Set with sending units Part Number: M 9999

INSTALLATION GUIDE Ford Mustang Digital Dash Panel Part Number: DP7009 Year Series:

INSTALLATION GUIDE Chevrolet Monte Carlo Dash Panel Part Number: DP9002 Year Series:

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6002 Year Series:

INSTALLATION GUIDE Chevrolet Impala/Caprice Digital Dash Panel Part Number: DP1208 Year Series: 1968

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6004 Year Series:

PHOENIX SPEEDOMETER INSTALLATION INSTRUCTIONS

Thank you for purchasing this instrument from Intellitronix. We value our customers!

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6002 YEAR SERIES:

CONTROL BOX. Wiring the control box into the vehicle. +12V

Switch select of sender types:

Classic Instruments Ford F100. Installation Manual

Full Sweep Minor Gauge Wiring:

Tach-Force Chevy Truck

Ford Mustang. Installation Manual

MODEL MVX-2011 TANK MOUNT SPEEDOMETER/TACHOMETER

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6003 Year Series:

Classic Instruments Cluster. Installation Manual

Classic Instruments. Ultimate Speedometer & Speed-Tachular. Installation Manual

UNIVERSAL GAUGE WIRE HARNESS

Series II ODYR/SLX-01-1-C PERFORMANCE SPEEDOMETER

Classic Instruments Chevelle. Installation Manual

Classic Instruments Chevy. Installation Manual

Replace light bulb with the same number bulb as the one removed. White Wire: Connect to +12 Volt Lighting

UTV-1200 Multi Gauge for 2008 Yamaha Rhino

Classic Instruments Ford. Installation Manual

ION-01-6 PERFORMANCE SPEEDOMETER/TACHOMETER COMBO

Part Number DP6003 Chevy Truck Digital Dash YEARS 67-72

Classic Instruments Camaro. Installation Manual. Revised: January 6, 2015 Page 1

Setup for using our speedometer with GPS sensor

UTV-1000 Multi Gauge for Yamaha Rhino

Classic Instruments & 1956 Chevy. Installation Manual

General Information. Installation Tips. Connections

6 Gauge Box Set with Programmable Speedometer. Made in the USA. Caution. Speedometer Parts. Tachometer Parts. Fuel Level Gauge Parts.

MCL-30K-SPD IMPORTANT NOTE!

6 Gauge Box Set IS0333

MODEL MCL-3212 SPEEDOMETER/TACHOMETER for 2012 up Dyna and Softail with 4 gauge

Ford Mustang

Replace light bulb with the same number bulb as the one removed. White Wire: Connect to +12 Volt Lighting

Classic Instruments. Six Pack. Installation Manual

Temperature Programming Quick Reference Guide

Mustang. Installation Manual

OMEGA KUSTOM INSTRUMENTS

Using the PST-2000 with Peterbilt Trucks. Document Number B

Programming Instructions for : Pressure 2 1/16 + DOWN MODE UP. Spek Pro Fuel Rail Pressure Gauge

NORMAL/DIAL BRIGHTNESS: Press the down or up button to adjust dial brightness. Press the center button to save and advance to PEAK PLAYBACK.

COMBINATION SPEEDOMETER/TACHOMETER GAUGE KIT J

FEATURES: SPEK PERFORMANCE GAUGE FEATURES:

NEXUS. Introduction SENSOR MODULE &

HLY-3016 PERFORMANCE SPEEDOMETER/TACHOMETER COMBO (weather and vibration resistant for exposed environments)

FEATURES: SPEK PERFORMANCE GAUGE TACHOMETER FEATURES:

5 Gauge Box Set IS0342

Chevy Truck

SPEK PRO MONITOR AND CONTROL

Chevy Truck

AURORA SERIES GAUGES FUEL GAUGE SUGGESTED TOOLS AND MATERIALS. 3 3 /8 in (85.7 mm) PARTS LIST

Owner s Manual DIGITAL HANDLEBAR GUAGE EA1640, EA1641

MODEL MCL-2002 TANK MOUNT SPEEDOMETER/TACHOMETER

Viewline Instrument Kit Installation Instructions. Rev E. Important Installation Notes:

MODEL MCL /8 SPEEDOMETER/TACHOMETER for 2004 up

Classic Instruments Chevy. Installation Manual

Chevy Truck

Speedo With Telltales and Display 85mm Tech Support Instruction Sheet # A2C Rev

MODEL MCV-7000 series SPEEDOMETER/TACHOMETER INFORMATION GAUGE Please read this before beginning installation or wiring.

HDX. Analog / Digital Gauge System INSTALLATION AND OPERATION MANUAL. Please read this before beginning installation or wiring.

REMOVAL OF FACTORY GAUGE ULTRA FLHT & FLHX (STREET GLIDE

Flow Chart Programming Instructions for : VOLTMETER 2 1/16

PRO-COMP/PHANTOM TACH

Chevy Truck

Chevy Truck

Chevrolet. Installation Manual

Tachometers and Tach/Hourmeters AT and ATH Series

SERIES 3 MODEL VFD3-88C-PU-U

Chevy Truck

VACUUM FLUORESCENT DIGITAL DASHBOARD. The latest in digital dashboard technology for the street rodder, car, and truck enthusiast.

Classic Instruments Corvette. Installation Manual

MODEL MCL-2002 TANK MOUNT SPEEDOMETER/TACHOMETER

SPA MICROPROCESSOR COMBINED TACHO&SPEEDO/GAUGE INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS

MCL-5100, 5200, & 5400 Bar mount digital speedometer with indicators.

FOR SERVICE SEND TO: AUTO METER PRODUCTS, INC. 413 W. Elm St., Sycamore, IL USA (815) us at

Mustang. Installation Manual. Revision 11/16/10

MCL-30K-TCH. Remove nuts/screws and clamp to remove factory gauges 1 MAN#650336

SERIES 3 MODEL VFD3-92C-PU-U

Classic Instruments. Installation Manual

REMOVAL OF FACTORY GAUGES ULTRA FLHT & FLHX

MODEL MCL-2004(-R) TANK MOUNT SPEEDOMETER/TACHOMETER

Package Contents: Transferring Data to a PC

Installation. Sender Pack. Installation Manuals. VHX Display. Control Box. CAT5 Cable. 1/8 Plastic Spacer

CUSTOM INSTRUMENT KIT INSTALLATION INSTRUCTIONS

MODEL HLY-2001 rev. B TANK MOUNT SPEEDOMETER/TACHOMETER INFORMATION SYSTEM

Classic Instruments SN74Z. Installation Manual

INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH

Transcription:

FULL SWEEP STEPPER MOTOR INSTRUMENT KIT INSTRUCTION MANUAL 1969,REDLINE, 2020 SERIES REVB071211

INDEX 3-3/8 PROGRAMMABLE SPEEDOMETER 3-3/8 TACHOMETER 2-1/16 GAUGES TEMPERATRURE SENDER PRESSURE SENDER PROGRAMMABLE FUEL GAUGE PROGRAMMING/USE OF RECALL FUNCTIONS PAGES 3-4 PAGES 5-6 PAGE 7 PAGE 7 PAGE 7 PAGE 8 PAGES 9-10 Thank you for choosing New Vintage USA products. We strive to provide the finest quality and design components available on the market. If you need technical assistance, please call 248.259.4964 or email info@newvintageusa.com New Vintage USA 5-Year Warranty New Vintage USA warrants all merchandise against defects in workmanship and materials for 60 months. After the 60 month period, a pro-rated service fee of no more than 50% production costs may be applied. This warranty applies to all instrumentation products, excluding senders. The warranty does not apply to a product used in a manner for which it was not designed, of if it has been altered in any way.; New Vintage USA LLC is not responsible for any damage or costs associated with any product that has been purchased. This is a limited warranty as identified in the Magnunson-Moss Warranty Act of 1975. Warranty Service Service can be obtained during the normal warranty period by contacting New Vintage and obtaining a Return Authorization Number (RZA#). New Vintage will repair or replace any item found to be defective and return ship to no cost via ground or post office services. Other shipping/international services will be applied at additional cost. Buyer is responsible for shipping to New Vintage for warranty repair. Return shipping will be the responsibility of the customer if the product is found to be damaged or out of warranty. An RZA number must be obtained and proper return/warranty form accompanied with the product. Missing items/returns Missing items/returns must be processed within 15 days of end user receiving the product. All returned must be shipped back to the place of purchase. Any return shipping costs to New Vintage are the responsibility of the purchaser. An RZA number must be obtained and proper return/warranty form accompanied with the product. A restocking fee not to exceed 10% may be applied to items that must be repackaged. Any item returned in a non-usable condition will be returned or charged to the customer. Missing items must be reported within 15 days of receiving the product. Items found to be missing will be shipped via ground or postal service at no charge. Expedited/international shipping options are available at an additional charge. It is the policy of New Vintage to quickly replace any items that may be missing in a timely manner but not to overnight or expedite shipping in any way at no cost.

3-3/8 PROGRAMMABLE SPEEDOMETER WIRING PIN ROW NOTE SIGNAL 1 TOP Connect to signal wire on speedometer sender. LAMP 1 2 TOP Connect to 12V+ dash lighting for white backlight. GROUND 3 TOP Connect to a good common ground. LAMP 2 4 TOP Connect to 12V+ dash lighting for amber backlight. ACC 5 BOTTOM Connect to 12V+ ignition circuit so power is ON when ignition is turned on. NOT USED 6 BOTTOM CAL 7 BOTTOM Connect to the RED wire on the calibration/trip button. BATT 8 BOTTOM Connect to a 12V+ source that is always on, even when ignition is OFF (i.e. Battery +) 3

Installation Instructions for 3-3/8 Programmable Speedometer Before You Start General Information Signal Interface This speedometer is designed to work with both hall effect senders and magnetic pickup sensors. The input level can range from TTL 5V square wave (hall effect) to AC sign wave signals (magnetic pickup). Connect the signal output wire from the sender to the SIG terminal on the gauge. Always consult the service manual for the vehicle you are working on to ensure proper connection. Incorrect hookup will damage the speedometer and void warranty. Please read these instructions carefully. Wiring Use 20 AWG stranded or heavier wire for installation. Route wires away from any moving parts and hot engine components. Secure wires firmly along their route. Note: As a safety precaution, the ACC and 12V+ connections should be fused. We recommend using a 1 Amp, 3 AG fastacting type cartridge fuse. Calibration 1. With the ignition off, press and hold the CAL/TRIP button. Turn the ignition on, then release the CAL/TRIP button. 2. The odometer/trip display will indicate CAL to verify that calibration mode has been accessed. The pointer will move to 50% scale. 3. Drive the vehicle EXACTLY one (1) measured mile then stop. 4. Press the CAL/TRIP button again to complete the calibration. 5. If the number of pulses is between 4,000 to 200,000 the odometer/trip display will indicate the actual pulses counted by the speedometer for five (5) seconds. This indicates a successful calibration. The speedometer will return to normal operation automatically. If the number of PPR is below 4,000 OR ABOVE 200,000 at the end of one mile, the odometer/trip display will show zeros for five (5) seconds after the button is pressed. The calibration will not be updated, and the original calibration will be maintained. Calibration/Trip Button Installation The speedometer includes a remote mount calibration/trip reset button. Connect the BLACK wire on the button to a common ground. Connect the RED wire to the CAL terminal on the speedometer. Mount the remote button in a convenient location. Odometer and Trip Operation The speedometer comes with an odometer (ODO) and two trip functions (TRIP 1 and TRIP 2). Press the CALIBRATION/TRIP button multiple times to cycle from ODO to TRIP 1 to TRIP 2. To reset a specific TRIP reading, hold the CALIBRATION/TRIP button for 3 seconds. The Odometer can not be reset. Dimmable LED Lighting This gauge features through-dial, high-definition LED lighting that will not dim when used with standard dash dimmers. A dimmer switch specifically designed for use with this gauge is available separately. 4

3-3/8 TACHOMETER WIRING PIN ROW NOTE SIG 1 1 TOP Use SIG 1 input if signal is a clean signal (tach output terminal, ECU, tach adapter etc.). LAMP 1 2 TOP Connect to 12V+ dash lighting for white backlight. GROUND 3 TOP Connect to a good common ground. LAMP 2 4 TOP Connect to 12V+ dash lighting for amber backlight. ACC 5 BOTTOM Connect to 12V+ ignition circuit so power is ON when ignition is turned on. SIG 2 6 BOTTOM Use SIG 2 input if you are using a signal from an ignition coil (-). NOT USED 7 BOTTOM BATT 8 BOTTOM Connect to a 12V+ source that is always on, even when ignition is OFF (i.e. Battery +) 5

3-3/8 TACHOMETER INSTALLATION, CONTINUED General Information 12-volt DC negative (-) ground electrical systems. Wiring Use 20 AWG stranded or heavier wire for installation. Route wires away from any moving parts and hot engine components. Secure wires firmly along their route. Note: As a safety precaution, the ACC and 12V+ connections should be fused. We recommend using a 1 Amp, 3 AG fast-acting type cartridge fuse. Tachometer Signal Hookup This performance tachometer has two signal input options (SIG 1 & SIG 2). See Fig 1. Signal Hookup. Choose the option best suited for your vehicle's ignition system. Only connect 1 signal input. If you are unsure which signal input to use, connect your signal source to SIG 1. NEVER CONNECT SIGNAL WIRE TO THE COIL WHEN USING AN MSD OR SIMILAR HIGH OUTPUT CAPACITIVE DISCHARGE STYLE IGNITION SYSTEM. Incorrect installation will damage the tachometer and the warranty will be voided. Calibration Calibration of the tachometer is done via dipswitches in the back of the gauge. There are 3 dipswitches, each of which can be set to OFF (down) or ON (up). See Fig 1 for dipswitch settings. Dimmable LED Lighting This gauge features through-dial, high-definition LED lighting that will not dim when used with standard dash dimmers. A dimmer switch specifically designed for use with this gauge is available separately. 6

2-1/16 INSTRUMENT WIRING DIAGRAM BLACK (PIN 2) OUTPUT GROUND RED (PIN 1) WARNING OUTPUT 12V+ RED (PIN1) MENU BUTTON RED BLACK (PIN 2) MENU BUTTON BLACK GREEN (PIN 3) USED ONLY ON FUEL SENDER FOR CALIBRATION RED (PIN 1) NOT USED BLACK (PIN 2) NOT USED GREEN (PIN 3) SENDER INPUT VIOLET (PIN 1) CONSTANT 12V + + - WHITE (PIN 2) WHITE LED LIGHTING- CONNECT TO DASH LIGHT DWITCH OR ORANGE (PIN 4) AMBER LIGHTING- CONNECT TO DASH LIGHT SWITCH RED (PIN 5) CONNECT TO SWITCHED FUSED CIRCUIT (ON WHIT IGNITION ON) 1 AMP FUSE BLACK (PIN 3) GOOD GROUND Pressure and temperature sender installation: Pressure and temperature sender wiring: Sender input is by wiring the sender to the green wire SENDER INPUT Voltmeter wiring: Voltmeter input is via a switched 12V+ (ignition on) by connecting the green wire SENDER INPUT 7

Fuel Level Gauge Calibration (CAL) Before installing the 5-in-1 fuel level gauge you may need to calibrate it to match your fuel level sending unit. The gauge factory default calibration setting is 0-90 Ohms (Empty-Full). The 5 available programmable input ranges are shown in Table 2 below. To change the calibration setting: 1. To access calibration mode, turn the power to the gauge on with the CAL wire grounded. The CAL wire is the GREEN wire on Pin 3 of Connector 2 (see Fig 1). 2. The pointer will stop at 50% scale (2/4) to indicate you have successfully accessed calibration mode. 3. Once the pointer stops at 50% scale (2/4) remove the CAL wire from the ground source. The pointer will move to indicate the current calibration setting per Table 2 below. 4. To change the calibration setting, momentarily ground the CAL wire. Each time you momentarily ground the CAL wire the calibration setting will change. 5. When the desired calibration setting is obtained (i.e. 73-10), leave the CAL wire ungrounded for 5 seconds. The gauge will save the new calibration setting, exit calibration mode and return to normal operating mode. FUEL GAUGE CALIBRATION SETTINGS, TYPICAL Typical Application Ohms (Empty-Full) Pointer Position Most GM Vehicles After 1965 Most Ford & Chrysler Vehicles Most GM Vehicles Before 1965 Most Ford Vehicles After 1986 0-90 1/8 73-10 3/8 0-30 5/8 20-150 3/4 8

2-1/16 INSTRUMENTS WITH HI/LOW WARNING AND PEAK RECALL Before You Start This gauge features peak recall, programmable high and low full dial warning and external warning output. Please read instructions completely before installing. ALWAYS WEAR SAFETY GLASSES. Install gauge only when engine is cool and ignition is off. Make sure all necessary tools, materials, and parts are on hand. Disconnect negative (-) battery cable before installing gauge. 2-1/16" gauge mounts in a 2-1/16" diameter hole. Make sure mounting location does not impair visibility or interfere with driving. Also check behind the mounting location for any wiring or components before drilling. MENU Button Installation Installation of the remote MENU button is only necessary if you want to use the RECALL and WARNING features of the gauge. Installation of the MENU button is NOT required if you do not wish to use the RECALL or WARNING features. Mount the included MENU button in a location that is convenient. Connect the red wire from the button to Connector 2, Pin 1 (Red) and the black wire on the button to Connector 2, Pin 2 (Black). See Fig 1. Dimmable LED Lighting This gauge features through-dial, high-definition LED lighting that will not dim when used with standard dash dimmers. A dimmer switch specifically designed for use with this gauge is available separately. Viewing and Clearing Peak Value (RECALL) 1. To view the peak value, press the MENU button one time. 2. To exit RECALL mode press the MENU button one time. 3. To clear the stored peak value press and hold the MENU button for 3 seconds while in RECALL mode. External Warning Output When warning mode is active the gauge outputs a 12V+ DC signal (500mA) on Pin 1 of Connector #1 (See Fig 1). This output is 0V when warning mode is not active. This output can be used to activate an external warning light or activate a switch. Do not install Connector 1 if external warning output is not required. 9

2-1/16 FUNCTION, CONTINUED Programming Full Dial Low Warning (WARN LO) This gauge can be configured to show a full dial low warning (flashing amber backlight) when the gauge goes BELOW a specific value (i.e. pressure goes below 10psi). 1. To access WARN LO programming mode, press and hold the MENU button until the pointer moves to 25% scale (approx 1 second). Release the MENU button after the pointer has reached 25% scale. 2. After releasing the MENU button the pointer will move to the current low warning set point. Factory default is 0% scale (WARN LO deactivated). 3. To change the set point, press the MENU button repeatedly to move the pointer by 2% increments. Once the pointer reaches 100% scale, pressing the MENU button will decrease the pointer position by 2% increments. 4. Once the pointer indicates your desired low warning set point leave the MENU button untouched for 5 seconds. The low warning set point will be saved and the gauge will return to normal operating mode. To turn the low warning OFF, repeat steps 1-4 above and change the low warning set point to 0% or 2% scale. Setting the low warning set point to 0% or 2% deactivates the low warning feature. Programming Full Dial High Warning (WARN HI) This gauge can be configured to show a full dial high warning (flashing amber backlight) when the gauge goes ABOVE a specific value (i.e. pressure goes above 80psi). 1. To access WARN HI programming mode, press and hold the remote button until the pointer moves to 75% scale (approx 3 seconds). Note: the pointer will stop at 25% scale for approx 1 second (for WARN LO programming mode), continue holding the button until the pointer has reached 75% scale. Release the button after pointer has reached 75% scale. 2. After releasing the button the pointer will move to the current high warning set point. Factory default is 100% scale (WARN HI deactivated). 3. To change the set point, press the MENU button repeatedly to move the pointer by 2% increments. Once the pointer reaches 0% scale, pressing the MENU button will increase the pointer position by 2% increments. 4. Once the pointer indicates your desired high warning set point leave the MENU button untouched for 5 seconds. The high warning set point will be saved and the gauge will return to normal operating mode. To turn the high warning OFF, repeat steps 1-4 above and change the high warning set point to 98% or 100% scale. Setting the high warning set point to 98% or 100% deactivates the high warning feature. 10

Notes: 11

RETURN AUTHORIZATION FORM RZA # CIRCLE ONE RETURN WARRANTY NAME ADDRESS CITY STATE ZIP PHONE( ) - EMAIL RETURN SHIPPING CHARGE INFO NAME ON CARD ADDRESS, ZIP CARD (CIRCLE ONE) VISA M/C NUMBER EXPIRATION SECURITY CODE (ON BACK) DESCRIPTION OF ISSUE: