NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: FM2369

Similar documents
QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

QWIK JON ULTIMA 203 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEMS MODELS 104*, 105, 110, 115, 120, 131

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

DRAIN PUMP SYSTEM MODEL 105 (Korean) INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

MODEL 585 BATTERY BACKUP PEDESTAL SUMP PUMP PREINSTALLATION CHECKLIST SEE BELOW FOR LIST OF WARNINGS CAUTION SEE BELOW FOR LIST OF CAUTIONS

INSTALLATION INSTRUCTIONS RECOMMENDED MODELS

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

Series: PFUEG 1/12HP, 5000 RPM, 60 Hz Utility Pumps

MODEL VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECK LIST SEE BELOW FOR LIST OF WARNINGS SEE BELOW FOR LIST OF CAUTIONS

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class 1, Division 1, Groups C & D Applications) Explosion Proof Motors

PRE-PLUMBED SEWAGE SYSTEM

ON-SITE WASTEWATER PROD UCTS

Pressure Booster System Models 350 & 351

PREINSTALLATION CHECKLIST

ON-SITE WASTEWATER PRODUCTS

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

AUTOMATIC SUBMERSIBLE UTILITY PUMP

SUBMERSIBLE SUMP PUMPS

OWNER S MANUAL 600 SERIES SUBMERSIBLE NON-CLOG UNITS. Safety Instructions. Table of Contents. Owner s Information

CAUTION PREINSTALLATION CHECKLIST. visit our web site: Your Peace of Mind is Our Top Priority. Section: 6.10.

SUBMERSIBLE SUMP PUMPS

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

Series: PFSWCPC75. 3/4 HP 1750 RPM 60 Hz Submersible Sewage Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

12 VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECKLIST

12 VOLT DC BATTERY BACKUP PUMP PREINSTALLATION CHECKLIST

MODEL 510 THE BASEMENT SENTRY II 12 VOLT DC BACKUP PUMP

OWNER S MANUAL. ZOELLER HAZARDOUS ENVIRONMENT PUMPS (For Class I, Division 1, Groups C & D Applications) Explosion Proof Motors

507/53 507/98 CAUTION. NOTICE TO INSTALLER: Instructions must remain with installation. Your Peace of Mind is Our Top Priority

SHEF30 Submersible Sump/ Effluent Pump

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

OWNER S MANUAL Series: PFSPPPP33 1/3 HP 3450 RPM 60 Hz Series: PFSPCPC50 1/2 HP 3450 RPM 60 Hz Submersible Sump Pumps

OWNER S MANUAL Commercial Duty Pumps

ESE Series Cast Iron Sewage Pumps

GARDEN HOSE UTILITY PUMP

Installation and Service Manual JB-1 System Sewage Ejector Pump Package

MODEL SPC-PANEL. Pump Controls for 2 HP Grinder Pumps

THERE IS NO OTHER EXPRESS WARRANTY.

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

HALLMARK INDUSTRIES INC

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

OWNER S MANUAL 71 SERIES SUBMERSIBLE GRINDER UNITS SAFETY INSTRUCTIONS TABLE OF CONTENTS OWNER S INFORMATION. visit our web site:

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

Series: PF33, PF33X, PF33X-30 PF33A, PF33AX, F33AX-30, PF33VF, PF33VFX, PF50X, PF50AX, PF50VFX

Full Flow Drinking Water System Model: 3MFF100

Potable Water Submersible Turbine Pumps

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

2460 / 2472 / Series Simplex Grinder Systems

SUNC3000 / Item #40885

StormPro BA Series Sump Pump

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

ME3H/ME3F SERIES. Automatic and manual models. Single phase power only 115 or 230 volt.

Installation Manual. Q Series Quadplex Grinder Systems. Contents

W/D/V-A1. Submersible Sump Pump. Pump Installation and Service Manual W-A1 V-A1 D-A1

OWNER S MANUAL MODEL 404/4404 AND

A+ Battery Backup Power Supply For use with Hydromatic model B-A1/BV-A1

OWNER S MANUAL X71 HAZARDOUS ENVIRONMENT SERIES CLASS I, DIVISION 1, GROUP C & D SUBMERSIBLE GRINDER UNITS CAUTION

OWNER S MANUAL MODELS 840, 841 & 842 SUBMERSIBLE GRINDER UNITS

StormPro BCV400 Sewage Ejector Pump

SUBMERSIBLE SWIMMING POOL DRAINER

Powerful & Intelligent Submersible Pumps

SUBMERSIBLE MINI-PUMP

S33 Sump Pump INSTRUCTIONS AND SERVICE MANUAL VERTICAL FLOAT SWITCH S33V1 & S33V1C AUTOMATIC S33P1 & S33PC-1 (CONTROL WITH SERIES PLUG) NOT SHOWN

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Safety Instructions. Table of Contents. Owner s Information

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

SIMPLEX, SINGLE PHASE PUMP CONTROL PANEL Model SPC-PANEL Pump Controls for 2 HP Grinder Pumps

OWNER S MANUAL 6680 SERIES SUBMERSIBLE NON-CLOG UNITS

Series: PF3CCE3, PF4CCE3, PF5CCE3, PF10CCE3, PF15CCE3, PF20CCE, PF25CCE

Access Riser Fits PRO370 and PRO380 Series

SHALLOW WELL JET PUMP

AEROMOTIVE Part # & Mustang 5.0L Stealth Fuel System Kit INSTALLATION INSTRUCTIONS

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL INSTALLATION AND OPERATION INSTRUCTIONS

Installation and Service Manual SK50 Submersible Sewage Ejector Pump

Non-qualifi ed users should never open or remove covers, as this will expose dangerous voltage points and other serious risks.

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

AEROMOTIVE Part # Ford 5.0 Liter INSTALLATION INSTRUCTIONS

MODEL HPGX200. (Class I, Division 1, Groups C & D): FM HAZARDOUS LOCATION SUBMERSIBLE GRINDER PUMP

SUBMERSIBLE POND PUMP

MODELS S4LX, S4BX, S4KX, S4QX, H4QX, S4LVX, S6AX, S6LX and S8FX

Owner s Manual Drill and Light Weight Portable Utility Pumps

L-SERIES PUMPS. Operating Manual. Includes Pumps: L-305 L PONDS

FP0S2300X FP0S3000X. Submersible Waterfall/Utility Pumps OWNER S MANUAL. Call Installation/Operation/Parts. English...

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

Operating Manual Includes Pumps: PG-9000 Part #R809606

Power Controller IMPORTANT INFORMATION. What s In the Box? Assembly, Operation, & Maintenance

PreSoak System (NonFoaming) DU PS1-HP DU PS6-HP

Model Numbers: MAC-36-BDF, MAC-42-BDF, MAC-48-BDF CONSUMER: READ AND SAVE THESE INSTRUCTIONS

OWNER S MANUAL MODELS 7011, 7012 & 7013 SUBMERSIBLE GRINDER UNITS. Table of Contents. Safety Instructions. Owner s Information

Pump Installation and Service Manual HRS Hydromatic Retractable System

QUALITY MISTING PUMPS

WELLWORTH WATER-GUARD WITH PEACEKEEPER VITREOUS CHINA SIPHON JET TOILETS

(Class I, Division 1, Groups C & D): FM

SPC-PANEL Simplex, Single Phase Pump Control Panel

STAR STOP SHALLOW WELL JET PUMP

S MANUAL 64 HD SERIES SUBMERSIBLE NON-CLOG UNITS

SUBMERSIBLE PUMP. Model ASSEMBLY AND OPERATING INSTRUCTIONS

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Transcription:

NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.063 FM2369 Product information presented here re fl ects con di tions at time of publication. Consult factory regarding discrepancies or inconsistencies. Patent No. 7,203,976 Other Patents Pending MAIL TO: P.O. BOX 16347 Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road Louisville, KY 40211-1961 (502) 778-2731 1 (800) 928-PUMP FAX (502) 774-3624 QWIK JON ULTIMA 202 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST visit our web site: www.zoeller.com 0410 Supersedes 0310 MODEL NO. DATE CODE: DATE INSTALLED: 1. Inspect all materials. Oc ca sion ally, products are damaged dur ing ship ment. If the unit is damaged, contact your dealer be fore using. Do Not remove the test plugs from the pump. 2. Carefully read all the lit era ture pro vid ed to fa mil iar ize your self with specifi c details re gard ing in stal la tion and use be fore at tempt ing the in stal la tion. These ma te ri als should be retained for future reference. SEE BELOW FOR LIST OF WARNINGS 1. To help reduce the risk of elec tri cal shock, a properly ground ed re cep tacle or con trol box of grounding type must be in stalled and pro tect ed by a ground fault circuit interrupter (GFCI) in ac cor dance with the Na tion al Electrical Code and applicable local codes. Never re move ground pin from plug. 2. Make certain that the ground fault in ter rupt er protected re cep tacle is with in reach of the pump s power supply cord. DO NOT USE AN EXTENSION CORD. Ex ten sion cords that are too long or too light do not deliver suffi cient voltage to the pump motor. But more im por tant, they could present a safety hazard if the insulation were to become damaged or the con nec tion end were to fall into a damp or wet area. 3. Make sure the pump's elec tri cal sup ply cir cuit is equipped with fuses or circuit break ers of prop er capacity. A sep a rate branch circuit, sized ac cord ing to the National Electrical Code for the current shown on the pump name plate is recommended (see Note 3). 4. TESTING FOR GROUND. As a safe ty mea sure, each elec tri cal outlet should be checked for ground using an Un der writ ers Lab o ra to ry Listed cir cuit an a lyz er which will indicate if the power, neutral and ground wires are cor rect ly con nected to your outlet. If they are not, call a qualifi ed licensed electrician. 5. FOR YOUR PRO TEC TION ALWAYS DIS CON NECT PUMP FROM ITS POW ER SOURCE BE FORE HAN DLING. If pump is wired direct, de-energize the circuit at the control box. Ground ed pumps are supplied with a 3-prong grounded plug to help protect you against the possibility of elec tri cal shock. DO NOT UNDER ANY CIRCUM STANCES RE MOVE THE GROUND PIN. To re duce the risk of elec tri cal shock, a properly grounded receptacle of grounding type must be installed and protected by a ground fault circuit interrupter (GFCI) in ac cor dance with National Elec tri cal Code and ap pli ca ble local codes. 6. Installation and checking of elec tri cal cir cuits and hard ware should only be performed by a qual i fi ed li censed electrician. 7. According to the state of California (Prop 65), this product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. SEE BELOW FOR LIST OF CAUTIONS 1. This unit is not designed to handle any material other than human waste and toilet paper. The following list includes, but is not limited to, items that should not be used with this system: Feminine sanitary products, condoms, cotton balls and swabs, baby wipes, paper towels, etc. 2. Check to be sure your power source is ad e quate to handle the am per age requirements of the motor as indicated on the pump or unit I.D. tag. 3. All plumbing (discharge and vent lines) must be installed to meet local codes. Unit must be vent ed. Do not use an automatic plumbing vent device. Toilet will not flush. 4. Maximum operating tem pera ture for model 202 must not exceed 130 F (54 C). 5. Do not use cleaning products containing bleach in the toilet tank, toilet or attached fi xtures as they will degrade the pump seals. NOTES SEE BELOW FOR LIST OF NOTES 1. Repair and service should be performed by an Authorized Service Station only. (Consult Factory.) 2. NOTE: Recommended for installations up to 20' total dynamic head. Consult Factory if installation is above 15' vertical height in 1" pipe. Mini-Grinder Pump is de signed for use in Qwik Jon Ultima units only. It is not designed for use in any other application. 3. Mini-grinder pump is rated for 115V, 60 Hz, 7 Amps,.5 HP. 4. NOTE: Pumps with the UL mark and pumps with the US mark are tested to UL Standard UL778. CSA Certifi ed pumps are certifi ed to CSA Standard C22.2 No. 108.Qwik Jon Ultima units only. It is not designed for use in any other application. 5. Model 202 toilet utilizes 1.6 gallons per fl ush. 6. All fi xtures connecting to the system must be on the same fl oor level. REFER TO WARRANTY ON PAGE 2. P/N 018507

Limited Warranty Manufacturer warrants, to the purchaser and subsequent owner during the warranty period, every new product to be free from defects in material and workmanship under normal use and service, when properly used and maintained, for a period of one year from date of purchase by the end user, or 18 months from date of original manufacture of the product, whichever comes fi rst. Parts that fail within the warranty period, one year from date of purchase by the end user, or 18 months from the date of original manufacture of the product, whichever comes fi rst, that inspections determine to be defective in material or workmanship, will be repaired, replaced or remanufactured at Manufacturer's option, provided however, that by so doing we will not be obligated to replace an entire assembly, the entire mechanism or the complete unit. No allowance will be made for shipping charges, damages, labor or other charges that may occur due to product failure, repair or replacement. This warranty does not apply to and there shall be no warranty for any material or product that has been disassembled without prior approval of Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident or act of God; that has not been installed, operated or maintained in accordance with Manufacturer's installation instructions; that has been exposed to outside substances including but not limited to the following: sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil, gasoline, solvents, etc.), or other abrasive or corrosive substances, wash towels or feminine sanitary products, etc. in all pumping applications. The warranty set out in the paragraph above is in lieu of all other warranties expressed or implied; and we do not authorize any representative or other person to assume for us any other liability in connection with our products. Contact Manufacturer at, 3649 Cane Run Road, Lou is ville, Ken tucky 40211, Attention: Cus tom er Ser vice De part ment to obtain any need ed repair or re place ment of part(s) or additional in for ma tion pertaining to our warranty. MANUFACTURER EXPRESSLY DIS CLAIMS LI A BIL I TY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF EX PRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WAR RAN TY OF FIT NESS FOR A PAR TIC U LAR PURPOSE AND OF MERCHANTABILITY SHALL BE LIMITED TO THE DU RA TION OF THE EX PRESSED WAR RAN TY. Some states do not allow limitations on the duration of an implied warranty, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or con se quen tial dam ag es, so the above lim i ta tion or exclusion may not apply to you. This warranty gives you specifi c legal rights and you may also have other rights which vary from state to state. Helpful Hints For Easy Installation 1. Read all instructions before beginning installation. 2. Be sure the fl oor is level within 1/8". 3. Install vent pipe seal with fl ange side of seal on outside of lid. 4. Use soapy water to lubricate all seals to aid in stal la tion. 5. Install rubber coupling/union in vent line to aid dis as sem bly. 6. Do not over torque toilet mounting screws. 7. Do not use an automatic plumbing vent device. 8. Obtain model number and date code, and record in for ma tion in the space provided on the front of this manual. Refer to this information when calling Fac to ry. Do s And Don't s For Installing A Unit 1. DO read all installation material with the unit. 2. DO inspect unit for any visible damage caused by shipping. Contact dealer if unit appears to be damaged. 3. DO clean all visible debris from the unit. 4. DO always disconnect pump from power source before han dling. DO always connect to a separately protected and prop er ly grounded ground fault protected circuit. DO NOT ever cut, splice or damage power cord. DO NOT carry or lift pump by its power cord. DO NOT use an extension cord. 5. DO install a ball or gate valve and a union in the discharge line downstream of the check valve. 6. DO test pump immediately after installation to be sure that the system is working properly. 7. DO review all applicable local and national codes and verify that the installation conforms to each of them. 8. We DO NOT recommend this product be connected to utilities other than those found in a normal bathroom application. Washing machines and dishwashers are examples of equipment that we Do Not recommend. 9. DO inspect and test system for proper operations at least every 3 months. 2

Typical Piping Configurations NOTE: All installations must comply with all ap pli ca ble Electrical and Plumbing Codes, in clud ing, but not limited, to Na tion al Elec tri cal Code; Local; Re gional and/or State Plumbing Codes, etc. Installation may not be exactly as shown. Service Parts SK2587 Item Description Part No. 1 Qwik Jon Ultima Model 202 Sewage Removal System without Toilet 202-1000 2 N202 replacement pump with discharge pipe 017374 3 Tank cover with discharge fi ttings 017373 4 Tank 018500 5 Seal 017350 6 Float switch assembly 018501 7 Toilet bowl 202-2000 Toilet tank with cover (left handed) 202-3000 8 Toilet tank with cover (right handed) 202-3001 Toilet tank cover (Figure A) 018504 9 Toilet tank cover (Figure B) 150012 10 Rubber coupling with hose clamps 018505 11 Extension kit for behind the wall installation 10-2123 12 Tank to Toilet Hardware 017360 13 Flush valve replacement kit 150658 14 Fill valve assembly with tube 150823 15 Flush valve assembly 150824 16 Flapper with clip and chain 150825 SK2605 3

Condition Possible Cause Remedy A. PUMP WILL NOT START OR RUN. B. PUMP STARTS TOO SOON. C. WATER LEVEL EXCESSIVE BE FORE PUMP TURNS ON. D. PUMP WILL NOT SHUT OFF OR RUNS TOO LONG BEFORE WATER IS PUMPED. E. PUMP OPERATES BUT DELIVERS LITTLE OR NO WATER. Low voltage, blown fuse, open circuit. Impeller bound. Motor or wiring shorted. Debris on fl oat switch. Float ON point is adjusted too low. Float ON point adjusted to high. Pump not plugged into piggyback fl oat switch receptacle. Debris under fl oat. Faulty fl oat switch. Float Off point adjusted too low. Pump is air locked. Water level too low. Waste material has accumulated blocking fl ow of material. Debris around intake. Blockage in discharge pipe. Low or incorrect voltage. Damaged Impeller. Incorrect fl oat adjustment. Pump is air locked. Vertical lift too high. Have a qualified electrician check fuse and cir cuit. Contact a Zoeller Service Station. Remove debris Raise the float stops, make sure the float is be tween the two stops. Lower the upper fl oat stop. Ensure pump is not plugged directly into the outlet. Plug pump into piggyback fl oat switch receptacle. Remove debris from around fl oat. Contact a Zoeller Service Station. Raise the lower fl oat stop. Make sure vent hole in discharge pipe is clear. Raise the lower fl oat stop. Hold fl ush handle down on toilet for 15 seconds. If unit will not clear, unplug and wait 30 minutes. Plug unit back in and repeat. If unit still will not turn off, it will need to be opened and the debris relocated. Clean area around intake. Remove pipe and fl ush out debris. Have a qualifi ed electrician check house wir ing. Contact a Zoeller Service Station. Contact Technical Service Department. Make sure vent hole in discharge pipe is clear. Change discharge piping or contact Technical Service Department. Before servicing a pump, always shut off the main power breaker and then unplug the pump - making sure you are not standing in water and are wearing insulated protective sole shoes. Under fl ooded conditions, contact your local electric company or a qualifi ed licensed electrician for disconnecting electrical service prior to pump removal. Submersible pumps contain oil which become pres sured and hot under operating conditions - allow 2½ hours after dis con nect ing before at tempt ing ser vice. Do not dispose of feminine sanitary products, dis pos able di a pers, dish rags, etc. in the QWIK JON ULTIMA. They may jam the pump or other plumbing lines and cause malfunction. CARE OF FINISH: Soap and water is all that is recommended for cleaning the outside of the tank. Other cleaning products may cause discoloration and scratching. If the above checklist does not solve the problem, consult Zoeller Technical Service Department 1-(800) 928-PUMP - Do not attempt to service or otherwise dis as sem ble pump. 4

Qwik Jon Ultima Qwik Reference Guide STEP 1 Location Selection Plan your new installation carefully. Floor: The fl oor should be structurally sound and level within 1/8". If the fl oor is not level, use hydraulic cement or similar material to level the fl oor. DISCHARGE PIPE VENT PIPE Water: A water supply will be needed to operate the toilet. Usually a 1/2" line with a shut-off valve is suffi cient. Electrical: A 115 volt GFCI receptacle will be needed to supply electrical power to the pump. Sewage: Access to a sewage line is required. The Qwik Jon Ultima requires a 1" (or 3/4" if your codes permit) sewage discharge line to connect to an existing sewage line. A ball or gate valve should be installed in the discharge line. Vent: Access to a vent pipe is required. The use of a mechanical vent system is NOT recommended as the toilet will not fl ush. GFCI OUTLET WATER SUPPLY BALL OR GATE VALVE SOLD SEPARATELY. LEVEL FLOOR NOTE: If a built-in installation is to be used, locate the pump unit in an area that will allow access to the pump and switch. SK2588 STEP 2 Leveling of Pump Unit Do not use wooden shims to level the pump unit! Ensure that nails, screws or other sharp objects do not puncture the pump unit! Level the pump unit to within 1/8" using hydraulic cement or similar material. SK2589 5

STEP 3 Toilet Assembly NOTES: a) Do not use pipe dope on any plastic or rubber parts. b) Be careful when tightening bolts or nuts against china to avoid cracking the china. Item Description 1 Toilet tank cover 2 Toilet tank 3 Toilet tank to toilet bowl gasket bolts 4 Rubber toilet tank to toilet bowl gasket 5 Water supply connection 6 Water supply line rubber seal 7 Water supply line adapter 8 Water supply line (not included) 9 Plastic fl at washer 10 Plastic nut 11 Bolt cover 12 Toilet bowl SK2593 WATER SUPPLY HOOK UP DETAIL TANK TO BOWL DETAIL SK2594 Set the black rubber washer. Push down on the top of the tank one side at a time to tighten the nuts under the bowl. Alternate tightening nuts making sure bowl is level. DO NOT OVERTIGHTEN. Ballcock shank may split and void the warranty. crack. DO NOT OVERTIGHTEN or china may 6

STEP 4 1) Position the pump unit a minimum of 1/8" from the wall with the inlet facing forward. Attach the bellows to the inlet using the worm drive clamp provided. 2) Place the toilet in front of pump unit aligning the discharge of the toilet with the inlet of the pump unit. Make sure that the bellows will bridge the gap adequately for final installation. The toilet tank should be a minimum of 1/2" from the wall. Rough-in (stand alone installation) 3) Lightly mark the locations of the pump unit, toilet and closet bolt locations on the fl oor. Lightly mark the wall with the height of the pump unit and the bottom and sides of the toilet tank to ensure against interference from pipe runs later. 4) Remove the toilet from the pump unit and set it aside. 14-3/8 31-1/2 17-1/2 20 SK2592 SK2590 STEP 5 Rough-in (behind the wall installation) 1) Installing the grinder unit behind a wall will require an extension kit (P/N 10-2123) sold separately. 2) Place the toilet assembly a minimum of 1/2" from the wall and mark the closet bolt locations on the fl oor. 3) Measure the appropriate length of 3½" Schedule 40 PVC pipe provided with the extension kit and cut it to length. See sketch at right. 4) Set toilet aside. Toilet assembly is top heavy. Take special precautions to ensure that toilet does not tip over and break. SK2634 7

STEP 6 Piping 1) Cut and dry-fi t the pipe and fi ttings as required for 1" diameter discharge pipe (may be reduced to 3/4" diameter if codes permit). 2) While dry-fitting the discharge pipe, position and mark the location of the pump unit discharge fi tting. 3) Cut and dry-fi t 1-1/2" vent pipe as required to ensure that the vent pipe does not interfere with other components. Make the connection to the pump unit with the provided street elbow. A 2" x 1" 90 discharge fi tting and a 1½" street elbow vent fi tting have been provided for space constraints in a stand alone confi guration. However, these are not required for a built in installation. It will reduce Total Dynamic Head on the system and simplify assembly on a built in installation to utilize straight pipe. For the discharge pipe, use a 2" straight coupling and reduce it down to 1". Proper venting is required for the toilet to fl ush. Do not use a mechanical type vent. 4) Temporarily set the toilet in place to check that there is no piping interference. Remove the toilet and set it aside. 5) Clean, prime and solvent weld the discharge piping and pump unit discharge fi tting. When applying solvent weld to discharge fitting, ensure that none gets into the check valve assembly. Pay close attention to the proper alignment of the discharge fi tting previously marked above. 6) Clean and solvent weld vent piping as required for proper venting. Note: Adding other bathroom fi xtures - The Qwik Jon Ultima is designed to accept additional bathroom fi xtures utilizing the two side inlets. These inlets can be attached via the 2" MPT (outside diameter) or the 1½" slip (inside diameter). These inlets must have the inner portion drilled out using a 1¾" hole saw. This is to ensure there is no leakage problems from inlets not in use. When utilizing side inlets, install a check valve on the incoming line. 2" MPT OUTSIDE 1-1/2" SLIP INSIDE DRILL POINT SK2589 SK2586 SK2591 STEP 7 Toilet Installation 1) Install the closet bolts at the points marked earlier. 2) Place the toilet assembly over the closet bolts. Install the anchoring hardware and tighten in an alternating pattern. Check for level and shim as required. Be careful when tightening bolts or nuts against china to avoid cracking the china. 3) Install rubber bellows onto the toilet discharge and grinder tank hub and secure with the worm clamps provided for stand alone installation. See sketch in Step 4. For built-in installation, install the rubber couplings to both the grinder tank and the toilet discharge and secure to extension pipe with worm clamps provided. See sketch in Step 5. 4) Install the water supply line from the existing water shut-off valve to the toilet water supply connection. 5) Open the water supply valve and check for leaks. The toilet tank should fi ll to the proper level. Adjust if required. 6) Plug the pump's power cord into the piggyback switch receptacle and then plug the piggyback switch into the GFCI outlet. 7) Flush the toilet and watch for proper operation. Listen for the pump to start. The pump unit requires proper venting in order for toilet to fl ush. Check for leaks. 8) Repeat fl ush cycles to assure proper operation. 9) Install an elongated toilet seat (supplied by others). 10) Install the lid on the toilet tank. GFCI OUTLET WATER SUPPLY 8 DISCHARGE PIPE PUMP UNIT FLOOR LEVEL TO WITHIN 1/8" VENT PIPE (PER ALL CODES. DO NOT USE MECHANICAL VENT.) AUX. INLET SK2595