lindab we simplify construction Plafond Service & maintenance

Similar documents
Architect Luna/Prisma/Circum Service & maintenance. lindab we simplify construction

Use. Installation. Key figures. Worth noting. linx industries chilled beams

Halton Rex 600 RE6 - Adaptable active chilled beam

LindabPodium. Supply air beam. lindab we simplify construction

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Chilled beam for ceiling installation

PROMAX INSTRUCTION MANUAL

Shut-off valves SVA-DH, SVA-DL

KWF Water Wash Canopy with Supply Air

EVAC Commercial Marine Equipment TOILET TECHNICAL DATA EVAC 90, STAINLESS STEEL, FLOOR MODEL, *SHOCK TESTED. Fresh water.

SEMI RIGID THE PROFESSIONALS CHOICE

PLAFOND B. Connection cover. lindab we simplify construction

KLIMA Active Chilled Beams

KVI Kitchen Canopy With Capture Air

Instructions for Installing the Vi p e r Si g n a l Ma s t e r

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

Paraffin Block Trimmer Quick Trim UPBT 1011

Highline 260i EC Waterside Fan Coil Unit

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

Variable Air Volume Dampers

KWT GALLEY WATER WASH HOOD GALLEY WATER WASH HOOD KWT. With supply air and Capture Jet technology

OptimAir NF. Active Chilled Beam OptimAir NF. Nov

ROL NOZZLE DUCT ROL-S ADJUSTMENT AND SILENCER UNIT

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System. Perfect 16. Installation Manual

GUIDE TO CLEANING grease extraction systems

COLIBRI Ceiling QUICK FACTS. Square ceiling diffuser with discs for supply air

series CEVH Smoke Evacuation Damper

Technote. Frese OPTIMA Compact DN10-DN50 - pressure independent balancing & control valve. Application. Features. Benefits.

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

Apartment ventilation

Soft Touch Tap Range. Fitting Instructions & Contents List. Please keep these instructions for future reference and request of replacement parts

Wall air diffusers with discs for supply air and flush mounting. Quick guide COLIBRI WALL

Automatic balancing valves ASV-PV DN (3rd gen.)

EAGLE Wall. Wall air diffusers with discs for supply air and flush mounting QUICK FACTS

Ventilation grilles for installation into walls, sills or rectangular

New Options Bath Shower Mixer

Tube Axial Inline Fans

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

BRC

Machine Deals. The Complete 3M System: The Right Machine + The Right Abrasive + The Right Accessory = Outstanding Result

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

ADRIATIC VF. Active climate beam with cooling, heating and ventilation QUICK FACTS

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

VAV TERMINAL UNITS. VVD VAV Diffusers

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

Ventilation grilles for installation into walls, sills or rectangular

Installation Guide The RSi brief overview:

Measuring probe For ventilation and air-conditioning Model A2G-FM

Floor Swirls Models BZD and SZD

High Performance Axial Fans

(L=500) L=300 (L=500) PL /E... electric actuator version. Table standard dimensions, L = 300 mm.

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

CornerAir. CornerAir. Active chilled beam

VCL : 2-way regulating valve for dynamic hydronic balancing, PN 16, Valveco

Ceiling swirl diffusers

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

HAWLE-AIR RELEASE VALVES

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

Curvare Tap Range. Fitting Instructions & Contents List

FIVC. Static Balancing Valve. Technical data. Dimensions

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

INSTALLATION & OWNER S MANUAL

Active Chilled Beams

REPUS. Nozzle/Nozzle duct R32/R60

Active Chilled Beams

Warning. Document ref: A October 2015

Sniper EFI Fuel Kits P/N 526-5/526-8 (20 ft. hose) & (40 ft. hose)

SERVICE MANUAL ULTIMATE 200

Instructions for Installing the Vi p e r Si g n a l Ma s t e r with Brake Module

Java Basin Mixer Range

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

AXIAL FANS Catalogue CN0050C01 May 2008

Explosion decoupling inside connected ductwork to protect separators

Sapphire Horizontal Waterside Control Fan Coil Units

for suspended installation. Active climate beam with cooling, heating and ventilation

ATZAF DOUBLE INLET AIRFOIL BLADEDBACKWARD CURVED CENTRIFUGAL FANS

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

FIREGARD GILBERTS. Curtain Fire Dampers FEATURES

Pressure relief dampers

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Zest Iris Duct Dampers

Swegon PACIFIC. Integrated climate beam

Fire Block and Pressed Steel Grilles

EXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC. Installation, Operation and Maintenance Manual

Complete HVAC Capability

Apartment ventilation

TYPE EK-EU SMOKE CONTROL DAMPER

Series 42 Self-operated Regulators. Type RS Check Valve (backflow protection)

Ventilation grilles for installation into walls, sills or rectangular

NAPAF - NAPBC HIGH PERFORMANCE AIRFOIL NAPAF AND BACKWARD CURVED NAPBC PLENUM FANS. 1 a Edition - subject to future integrations

PROHOOD AIR CAPTURE HOOD MODEL PH731

Self Closing Tap. Fitting Instructions & Contents List. Please keep these instructions for future reference and request of replacement parts

Ventiduct nozzle ducts

Accessories. Series REC

2-Port and 3-Port Zone Valves PN 16

Ventiduct nozzle ducts

Transcription:

Service & maintenance

1.0 Installation 1.1 Product description The chilled beams are designed for installation in the space between the ceiling and the wall. Especially suitable when the ceiling should be free from equipment. The supply air is directed along the ceiling or wall. 1.2 Handling The beam must be handled with care, ensuring that the beam does not sustain dents, scratches or bends during installation. Always seek to lift the beam at multiple points. Do not lift in pipes Do not lift in edges Each beam is equipped with protective film to avoid any damage during transport and handling at building site. The film needs to be removed before commissioning the products. 1.3 Mounting instruction Please visit www.lindqst.com Select Documentation Finder Select Select Mounting 1.4 Air connection installation The primary air supply should be connected with instructions from a ventilation specialist. Lindab s chilled beams can beneficially be used together with Lindab s Safe duct systems. 1.5 Connection description water Flow indication arrows are shown on the inlet and return pipes in order to assist the installer. If the beam has been ordered with integrated valves, a special direction of the flow must be upheld to ensure correct flow through the thermostatic valve. If the beam has been delivered without integrated valves, the flow can be reversed, depending on the location of the retrofitted valve. Please note the flow direction indicator on the valve to insure correct installation in relation to the desired flow. 2

1.5.1 Push-on fittings Please ensure that all pipes and fittings are undamaged, as even small dents and scratches potentially pose a risk of leakage in the system. Always remember to do a pressure test after assembly of the pipe work. Both flow and return pipe is covered by a plastic or rubber protection cover, which should be removed before installation. After removing the protection cover, make sure that the pipe is intact and undamaged, especially at the pipe end. Crocked or in other ways imperfect pipe ends will result in leaks. Deburr the pipe on the inside and the outside, using a deburring tool before installation Mount a push-on fitting to the pipe. Make sure to press the fitting all the way onto the pipe. Consult the installation guide for the specific fitting for further details on proper installation. Push-on fitting 3

Push-on valve Notice! The connection pipes are internally soft-welded why it s not allowed to solder the beam to the pipes. 1.5.2 Compression fitting Please ensure that all pipes and fittings are undamaged, as even small dents and scratches potentially pose a risk of leakage in the system. Always remember to do a pressure test after assembly of the pipe work. While mounting a compression fitting, the pipe will be exposed to a big amount of force, creating a risk of crushing the pipe. To ensure that the pipe won t be crushed when mounting the compression fitting, a copper insert should be inserted into the pipe. Both flow and return pipe is covered by a plastic or rubber protection cover during transport, which must be removed before installation. After removing the protection cover, make sure that the pipe is intact and undamaged, especially at the pipe end. Crocked or in other ways imperfect pipe ends will result in leaks. Deburr the pipe on the inside and the outside, using a deburring tool before installation 4

The copper insert should be placed inside the pipe on the beam. Always support the copper pipe coil when inserting the copper insert into position. Mount a compression coupling and/or a valve to the pipe. Don t stress the nut too much, since this may crush the pipe. Notice! The connection pipes are internally soft-welded why it s not allowed to solder the beam to the pipes. 1.5.3 Flex hoses Our flexible hoses can be used with both compression and Tectite fitting. We recommend using Tectite fittings, for easier and faster mounting. Please ensure that all pipes and fittings are undamaged, as even small dents and scratches potentially pose a risk of leakage in the system. Always remember to do a pressure test after assembly of the pipe work. Both flow and return pipe is covered by a plastic or rubber protection cover, which should be removed before installation. 5

After removing the protection cover, make sure that the pipe is intact and undamaged, especially at the pipe end. Crocked or in other ways imperfect pipe ends will result in leaks. Deburr the pipe on the inside and the outside, using a deburring tool before installation Mount a push-on fitting to the pipe. Make sure to press the fitting all the way onto the pipe. After mounting the push-on fitting, mount the flexible hose. Make sure that the flexible hose is pushed fully into the fitting. Consult the installation guide for the specific fitting for further details on proper installation. Push-on fitting Push-on valve Notice! The connection pipes are internally soft-welded why it s not allowed to solder the beam to the pipes. 6

2.0 Commissioning 2.1 Product labeling Fig.1: Label location exterior (On plastic wrapping) Fig.2: Label location interior (Air connection end) On the label you ll find: Order: Order identification number. Pos: Order position. Product: Product configuration. Project: Project name. Mark: Marking noted on order. Nozzles: Number of nozzles. Plugs: Number of plugged nozzles. Product ID: Product number. Sign: To be signed when checked and commissioned on site. 2.2 Measure air pressure and calculating the airflow. Before calculating the airflow, the static nozzle pressure must first be measured. The static nozzle pressure is the air pressure available at the nozzles. 2.2.1 Measure the static nozzle pressure. To measure the air pressure, a manometer, analog or digital (such as the Lindab PC410) will be needed. Insert the measuring tube onto the specialized measuring nozzle Read off the static nozzle pressure from the manometer 7

2.2.2 Calculating the airflow After measuring the static nozzle pressure, calculate the air flow per nozzle: q=0.0209 P q = air flow per nozzle P = static nozzle pressure After finding the air flow per nozzle, find the needed number of open nozzles: q tot /q=n open q tot = total air flow n open = open nozzles Alternatively, read off the needed number of nozzles in the diagram below. Δp t [Pa] 100 90 80 70 60 50 Total open nossles 40 50 60 75 100 125 150 175 200 225 250 275 300 325 350 375 400 450 500 550 40 30 20 q a [l/s] 5 6 7 8 9 10 15 20 25 30 40 50 60 70 80 Diagram 1: Shows needed number of open nuzzles to reach a desired air flow at a given pressure. 8

2.3 Apply plugs to reduce airflow When the needed amount of open nozzles have been found, plug or unplug nozzles to reach the needed amount. Use the specially designed Lindab Nozzle Plugs and Lindab plugging tool to plug the nozzles. To plug a nozzle, first locate the nozzles to plug. Keep in mind that the closed nozzles should be diveded as equally along the beam as posible to reach a symetric spread pattern. Insert the plug into the nozzle. Make sure that the plug is fully inserted. The reconfiguration is now complete. 2.3.1 Removing plugs to increase airflow Reverse the steps above. 9

3.0 Maintenance The interval of cleaning depends on the indoor environment where the beam is placed. Under optimal conditions the beams only need cleaning every 5 years. 3.1 Cleaning instructions Remove the faceplate Clean underneath the battery with a vacuum cleaner and a piece of wet cloth Only use lukewarm water and a mild detergent. 10

4.0 Product and system specification 4.1 Material data Weight, kg/m 11.5 Water content, cooling, l/m 0.50 Water content, heating, l/m 0.25 Copper pipes, quality SS/EN 12449 Pressure class PN10 4.2 Environmental declaration Please visit www.lindqst.com Select Documentation Finder Select Select Environmental declaration 4.3 Working and test pressure Lindab s waterborne products have been manufactured and tested according to the Pressure Equipment Directive 97/237EC. The products are classified as SEP Sound Engineering Practice. Pressure table Pressure class Max. working pressure Max. recommended dynamic pressure Max. test pressure PN10 10 bar 0,2 bar 16 bar Even though the battery of the chilled beam can withstand a very high static working pressure, we recommend a much lower dynamic working pressure, to avoid noise issues from the valves. 11

4.4 Water quality The water preparation and maintenance for the chilled beam water circuit should be handled by a specialist To prevent corrosion, the water circuit must be airtight The water system must also be equipped with aerators to remove any build-up air in the system. The water should be oxygen free, to prevent corrosion. The water system must be filled with potable water that complies with the EC directive 98/83/EC. ph value of water must be between approximately 6-9 ph The water velocities should not exceed 1m/s, and should be kept as close to the nominal flow as possible to minimize noise and optimize the energy yield There should be used in-line strainers to remove dirt particles from the water. If the water contains any additive inhibitor this must be appropriate to use with copper and solder. 4.5 Air quality Primary supply air should be clean and filtered before reaching the beam. 4.6 Capacity test Lindabs active chilled beams are Eurovent-certified and tested according to EN-15116. 12

Support Hjælp Hjälp Tuotetuki Unterstützung Supporto UK - Here you can find product updates/mounting instructions and support telephone number/mail. www.lindab.com Right to alterations reserved. DK - Her kan du finde seneste produkt opdateringer/montagevejledninger samt support tlf. nr/mail. www.lindab.dk Ret til ændringer forbeholdes. SE - Här kan du alltid hitta senaste produktuppdateringarna/montageanvisningarna samt support tel. /e-mail. www.lindab.se Rätt till ändringar förbehålles. FI - Täältä löydät uusimmat tuotetiedot ja asennusohjeet sekä tuotetuen yhteystiedot. www.lindab.fi Oikeus muutoksiin pidätetään. DE - Hier finden Sie aktuelle Produktinformationen/ Montageanleitungen und Telefonnummer/ E-Mail-Adressen der Ansprechpartner. www.lindab.de Änderungen vorbehalten. IT - Qui potete trovare istruzioni di montaggio, informazioni sul prodotto ed un supporto tecnico qualificato Tel. 011 9952099 - e-mail: lindab@lindab.it www.lindab.it Soggetto a modifica senza obbligo di preavviso. FR - Vous trouverez les fiches produits ou de montage actualisées ainsi que les coordonnées du support téléphonique à l adresse suivante : www.lindab.fr Toutes modifications réservées. Do you have trouble finding your local contacts please go to: www.lindab.com -03052013 www.lindab.com