Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 250/400/630 A, 185mm Sammelshienenabstand

Similar documents
Special Purpose Fuses

Technical data. Busbar support 3 7, 5 6, 8 ETIBUSBAR 1 0, 5 BBS-60/4


K50H004UP cam changeover switch - 4-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting

LV HRC fuse switch-disconnectors

Cylindrical fuse-link

Fuse switch-disconnectors

AF40... AF96 3-pole contactors Technical data

Fuse switch disconnectors

Vertical fuse disconnects

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Size 00-4a LV HRC fusebases. plates and for direct mounting on busbars. In addition, they serve as bases for LV HRC fuselinks

vertical fuse switch disconnectors

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

MULTIBLOC 2.RST8 Size 2, 400A, 690VAC, Design for bus bar installation, Triple Pole

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Fuse switch-disconnectors

9-0. Product family. LV HRC fuse switch-disconnectors. Surface mounting Busbar mounting

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

Varius SUMMARY OF MODELS

Position switches FD series

Cylindrical fuse-link

Motorized switch-disconnectors OTM 40 to 125 Amperes

Safety rope switches with reset for emergency stop

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

FL series position switches

K63F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

D509E. Manual Motor - Starters

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

70 RT HP SWITCH DISCONNECTORS IN PLASTIC BOX

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

Horizontal fuse disconnects

Vertical fuse disconnects

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Safety rope switch with reset for emergency stop

Modular contactor for installation into distribution boards

MULTIBLOC 1.ST8 Size 1, 250A, 690VAC, Design for Bottom Fitting, 1-,2-,3-,4-pole

MULTIVERT 1000A Main Incomer, 690VAC

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Fuse Switch Disconnectors XNH. Fuse Switch Disconnectors XNH... For fuse links NH000 to NH3. Rated operating current of 160, 250, 400 and 630A

MULTIBLOC 2.ST8 Size 2, 400A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Special Purpose Fuses

Vertical fuse disconnects

PUSHBUTTON SWITCHES. electrical controls 1/5 SPECIFICATIONS: TECHNICAL DATA CONTACT BLOCKS LIGHTING BLOCKS

Industrial Contactors CTX 3 3P 185A - 800A

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

LC1F330M7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 330 A - coil 220 V AC

XACA871 pendant control station XAC-A - 8 pushbuttons

Fuse switch disconnectors

LC1F500FD TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 500 A - coil 110 V DC

LK Position Switches TECHNICAL DATASHEET.

SFS-UFS Single Foot Switches

Safety switches with separate actuator

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

ASL09..S 3-pole Contactors - Spring Terminals

Pressure switches 30 A/F

6-0. Product family. LV HRC strip-fuseways

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A

cor Long Run Experience

Electronic overload relays EF205 and EF370

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

MANUALLY OPERATED CHANGEOVER SWITCHES

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

ic60a circuit breakers (curve C)

Varius SUMMARY OF MODELS

mainly used for power distribution

Thermal Overload Relays - WEG RW Series, 2 Pole

XACA871 pendant control station XAC-A - 8 pushbuttons

3NP1 Fuse Switch Disconnectors up to 630 A

NB1 Miniature Circuit Breaker

Varius SUMMARY OF MODELS

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Switches with manual reset

Limit Switch - Prewired Type Metal Body

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Safety switches for hinged doors

XACA871 pendant control station XAC-A - 8 pushbuttons

LC1F630F7 TeSys F contactor - 3P (3 NO) - AC-3 - <= 440 V 630 A - coil 110 V AC

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Limit Switches - Limit Type (PS21L) Metal Body IP66

GREEN PROTECT PROTECTION OF PV SYSTEMS. Green protect - DC POWER NEEDS CONTROL

LC1F400E7. Main. Product or component type Device short name. Utilisation category. Poles description Pole contact composition

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

LR-LX-LK-LW Safety Switches with separate actuator

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Miniaturecircuitbreaker(MCB),6A,1Np,C-Char,AC. Application Switchgear for industrial and advanced commercial applications.

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Limit switches 3. Page 92. Page 92

For Info: Phone: Fax:

TAE pole Contactors

Bulletin 193-T1 Bimetallic Overload Relays

Transcription:

LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Range / Produktpalette Type 415 fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing Typ 415 NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 2/400/, mm Sammelshienenabstand Reference Artikelnummer Type Typ Current Nennstrom Protection Schutz Connections Anschluss Fuse-link Busbar spacing Sicherungseinsatz Sammelschienenabstand 415.11.10.XX.YY 415.12.10.XX.YY BTVA Without protection ohne Schutzabdeckung Top / Bottom Oben / Unten NH-1 NH-2 415.21.10.XX.02 415.22.10.XX.02 415.23.10.XX.02 BTVA-P mm protection mit Schutzabdeckung mm Top / Bottom Oben / Unten NH-1 NH-2 NH-3 mm 415.31.10.XX.02 415.32.10.XX.02 415.33.10.XX.02 BTVA-P 120mm protection mit Schutzabdeckung 120mm Top / Bottom Oben / Unten NH-1 NH-2 NH-3 BTVA BTVA-P Terminals / Anschlüsse XX Code: page/seite??? Accessories / Zubehör YY Code: page/seite??? Technical Data / Technische Daten: page/seite??? Dimension drawings / Abmessungen: page/seite??? 20

LV-SWITCHING DEVICES / NH-SCHALTGERÄTE 1 Vertical 415 design fuse rails TRIVER / NH-Sicherungsleisten TRIVER Dimensions fuse rails BTVA/BTVA-P, NH 1/2/3, 2/400/, mm busbars spacing Abmessungen NH-Sicherungsleisten, BTVA/BTVA-P, NH 1/2/3, 2/400/, mm Sammelschienenabstand BTVA / BTVA-P BTVA-P Width / Breite mm BTVA-P Width / Breite 120mm BTVA-P NH 1/2 x=118 y=164 BTVA-P NH 3 x=128 y=174 BTVA-P NH 1/2 x=118 y=164 BTVA-P NH 3 x=128 y=174 Range / Produktpalette: page /Seite 25

Vertical design fuse switches NH-1/2/3 2/400/ One pole switching - Reference Type Current Switching Connections Fuse link 428.51.10.XX.YY 428.52.10.XX.YY 428.53.10.XX.YY one pole XX: add code for terminal type (see page 33) YY: add code for accessories (see page 34-35) Bottom connection Top connection 315 165 95 94,5 775 665 600 6 206 197 103,5 0 187 206 165 315 25

Vertical design fuse switches NH-1/2/3 -E 2/400/ One pole switching - - with retractable handle Reference Type Current Switching Connections Fuse link 428.41.10.XX.YY 428.42.10.XX.YY 428.43.10.XX.YY -E -E -E one pole with retractable handle XX: add code for terminal type (see page 33) YY: add code for accessories (see page 34-35) -E Bottom connection Top connection 315 165 775 665 600 6 206 197 103,5 0 95 94,5 187 206 165 315 26

Vertical design fuse switches NH-1/2/3 T 2/400/ Three pole switching - Reference Type Current Switching Connections Fuse link 428.61.10.XX.YY 428.62.10.XX.YY 428.63.10.XX.YY T T T three pole 428.91.10.XX.YY 428.92.10.XX.YY 428.93.10.XX.YY -BC -BC -BC three pole with locking device XX: add code for terminal type (see page 33) YY: add code for accessories (see page 34-35) T and -BC Bottom connection Top connection 355 780 0 103.5 775 665 600 6 206 197 0 187 206 95 94.5 355 26

Vertical design fuse switches NH-1/2/3 /T 2/400/ One pole switching - lateral input Reference Type Current Switching Connections Incoming connection Fuse link 428.51.62.XX.YY 428.52.62.XX.YY 428.53.62.XX.YY lateral input one pole right side nut 428.51.63.XX.YY 428.52.63.XX.YY 428.53.63.XX.YY lateral input one pole left side nut 428.61.62.03.YY 428.62.62.03.YY 428.63.62.03.YY T lateral input three pole right side nut 428.61.63.03.YY 428.62.63.03.YY 428.63.63.03.YY T lateral input three pole left side nut XX: add code for terminal type (see page 33) YY: add code for accessories (see page 34-35) 140 75 1 311 - lateral input Right side lateral input 775 665 6 600 360 140 75 311 1 197 206 197 Left side lateral input 665 775 206 360 28

Vertical design fuse switches NH-1/2/3 /T 2/400/ Three pole switching - lateral output Reference Type Current Switching Terminal type Connections Fuse link 428.51.60.XX.YY 428.52.60.XX.YY 428.53.60.XX.YY lateral ouput one pole inserted nut right side 428.51.61.XX.YY 428.52.61.XX.YY 428.53.61.XX.YY lateral ouput one pole inserted nut left side 428.61.60.XX.YY 428.62.60.XX.YY 428.63.60.XX.YY T lateral ouput three pole inserted nut right side 428.61.61.XX.YY 428.62.61.XX.YY 428.63.61.XX.YY T lateral ouput three pole inserted nut left side XX: add code for terminal type (see page 33) YY: add code for accessories (see page 34-35) T - lateral output 140 75 335 Right side lateral output 665 6 600 1 197 103,5 140 75 335 Left side lateral output 1 665 197 103,5 29

Vertical design fuse switches NH-3 DU 910 A One pole switching Reference Type Current Switching Terminal type type Connections Fuse link 428.58.13.04.02* DU 910 A one pole inserted nut g Tr 428.58.13.36.00 DU 910 A one pole Ø14 special plate top g Tr 428.58.16.08.00 DU 910 A one pole Ø14 rear plate rear g Tr * with connection over (see page 34) Bottom connection Top connection DU STANDARD 188 151 84 56 46 665 247 160 912 102 5 5 247 160 917 0 193 84 56 46 151 314 DU SPECIAL PLATE 200 75 75 5 368 n14 762 20 55 151 314 298 261 424 DU REAR INPUT 108 193 669 80 5 n14 15

Vertical design double fuse switches NH-2/3 800/1260 A One pole switching - Reference Type Current Switching Terminal type Connections Fuse link 428.54.70.XX.YY 428.54.71.XX.YY 428.54.72.XX.YY 800 A 105 bolt/inserted nut 428.56.70.XX.YY 428.56.71.XX.YY 428.56.72.XX.YY 1260 A 105 bolt/inserted nut 428.56.84.03.02 428.56.82.03.02 1260 A inserted bolt XX: add code for terminal type (see page 33) YY: add code for accessories (see page 34-35) Bottom connection Top connection bolt/inserted nut 33 105 52.5 52.5 inserted bolt A + 163 315 95 33 A + A 315 913 913 197.5 103.5 13 913 913 187 0 146 94.5 665 2 A + 163 A A + 33 33 2 665 52.5 52.5 105 32

Technical data TRIVER LV fuse rails & fuse switches Vertical design fuse rails NH-1/2/3 BTVA 2 / 400 / (fuse rails reference 415) IEC / EN 60269 Type BTVA / BTVA-P Type 415 Electrical characteristics Rated operational voltage Ue (V) AC 0 AC 690 AC 0 AC 690 AC 0 AC 690 Rated operational current Ie (A) 2 200 400 315 6 0 Conventional free air thermal current with fuses Conventional free air thermal current with solid links Ith (A) 2 200 400 315 6 0 Ith (A) 320 510 800 Rated frequency (Hz) Rated conditional short-circuit current (kaeff) Test voltage (kv) 3 Total power loss at Ith (without fuse) Pv (W) 25 16 52 32 98 62 Mechanical characteristics Weight (kg) 3, 3,610 4,380 Busbar distance (mm) Fuse links Size to IEC / EN 60269 -- 1 2 3 Max. rated current (gl/gg) In (A) 2 200 400 315 6 0 Max. permis. power loss per fuse-link Pv (W) 32 45 60 Terminals Bolt terminal Diameter -- M10/ Cable lug (S/DIN 46235) (mm 2 ) 2x25-0 Torque (Nm) 32 V-terminal Terminal cross section (mm 2 ) -0 Torque (Nm) 25 Bimetallic terminal Terminal cross section (mm 2 ) 35- Torque (Nm) 32 Protection level Front operated switchgear fi tted -- IP20 Operating Conditions Ambient temperature ( C) -25 to +55 *(1) Rated operating mode -- continuous operation Actuation -- dependant manual operation Mounting position -- vertical / horizontal Altitude (m) up to 2000 Pollution degree -- 3 Overvoltage category -- IV *(1) 35 C normal temperature, at 55 C with reduced operating current 46

Technical data TRIVER LV fuse rails & fuse switches Vertical design fuse switches NH-1/2/3 - one / three pole switching / T 2 / 400 / (fuse switches reference 428) IEC / EN 60947 Electrical characteristics *(1) 35 C normal temperature, at 55 C with reduced operating current Type / T Type 428 Rated operational voltage U e (V) AC C 0 AC 690 AC C 0 AC 690 AC 0 AC 690 Rated operational current Ie (A) 2 2 200 400 400 315 6 0 Conventional free air thermal current with fuses Ith (A) 2 2 200 400 400 315 6 0 Conventional free air thermal current with solid links Ith (A) 400 400 510 510 800 Rated frequency (Hz) 40-60 Rated insulation voltage U i (V) AC 0 Rated conditional short-circuit current (ka eff) 80 Utilization category -- AC-23B AC-22B AC-23B AC-22B AC-22B AC-21B Rated making capacity (A) 20 1200 600 4000 1890 945 1890 7 Rated breaking capacity (A) 2000 1200 600 3200 1890 945 1890 7 Rated impulse withstand voltage U imp (kv) 20kV Operating cycles with current -- 200 Total power loss at I th (without fuse) P v (W) 25 25 16 52 52 32 98 62 Mechanical Weight (kg) 5,120 5,4 6,240 characteristics Busbar distance (mm) Panel front opening * (see picture on page ) (mm) 600/6 Operating cycles without current -- 1400 1400 1400 800 800 1400 800 800 Fuse links Size to IEC / EN 60269 -- 1 2 3 Max. rated current (gl/gg) I n (A) 2 2 200 400 400 315 6 0 Max. permis. power loss per fuse-link Pv (W) 23 34 Terminals Bolt terminal Diameter -- M10/ Cable lug (S/DIN 46235) (mm 2 ) 2x25-0 Torque (Nm) 32 V-terminal Terminal cross section (mm 2 ) -0 Torque (Nm) 25 Bimetallic terminal Terminal cross section (mm 2 ) 35- Torque (Nm) 32 Protection level Front operated switchgear fi tted -- IP20 Operating Ambient temperature ( C) -25 to +55 *(1) Conditions Rated operating mode -- continuous operation Actuation -- dependant manual operation Mounting position -- vertical / horizontal Altitude (m) up to 2000 Pollution degree -- 3 Overvoltage category -- IV 47

Technical data TRIVER LV fuse rails & fuse switches Vertical design fuse switches NH-3 910 A Vertical design double fuse switches NH-2/3 800 / 1260 A (fuse switches reference 428) IEC / EN 60947 Type Type 428 910 A 800 A 1260 A Electrical characteristics Rated operational voltage Ue (V) AC C 0 AC 690 AC 0 AC 690 Rated operational current Ie (A) 910 800 6 1260 0 Conventional free air thermal current with fuses Conventional free air thermal current with solid links Ith (A) 910 800 6 1260 0 I th (A) 12 960 7 10 1200 Rated frequency (Hz) 40-60 Rated insulation voltage Ui (V) 0 AC 0 Rated conditional short-circuit current (kaeff) Utilization category -- AC-22B AC-22B AC-21B AC-21B AC-20B Rated making capacity (A) 27 2400 945 2400 -- Rated breaking capacity (A) 27 2400 945 2400 -- Rated impulse withstand voltage Uimp (kv) 20 20 -- Operating cycles with current -- -- Total power loss at Ith (without fuse) P v (W) 200 70 200 1 Mechanical characteristics Weight (kg) 12,974 14,536 15,722 Busbar distance (mm) Panel front opening * (see picture on page ) (mm) 600/6 600/6 Operating cycles without current -- 0 0 Fuse links Size to IEC / EN 60269 -- 3 2 3 Max. rated current (gl/gg) In (A) 910(gTr) 400 315 6 0 Max. permis. power loss per fuse-link Pv (W) 70 34 45 60 Terminals Bolt terminal Diameter -- Cable lug (S/DIN 46235) (mm 2 ) 2x95-0 3x95-0 Torque (Nm) 32 32 Protection level Front operated switchgear fi tted -- IP20 Operating Conditions Ambient temperature ( C) -25 to +55 *(1) Rated operating mode -- continuous operation Actuation -- dependant manual operation Mounting position -- vertical / horizontal Altitude (m) up to 2000 Pollution degree -- 3 Overvoltage category -- IV *(1) 35 C normal temperature, at 55 C with reduced operating current