GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Similar documents
GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

WPS60/S EP Series. Features:

WPS100/S EP Series. Features:

WPS350/S EP Series. Features:

WPS150/S EP Series. Features:

EC Series GMS200C. Generator Set Specification. Your Partner for Power. Page of 5

WPS250/S EP Series. Features:

WPS20/S EP Series. Features:

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

EP Series WPS150S. Generator Set Specification. Super Quiet, Superior Life! Page of 5

GMS200C/S EC Series. Features:

GMS350C/S EC Series. Features:

GMS100C/S EC Series. Features:

EP series WPS100S-AU rpm,3-phase/5-wiring

EP series WPS150BS-AU rpm,3-phase/5-wiring

EP series WPS800S rpm,3-phase/5-wiring

Better Soundproof, Better Life!

Super Silent, Superior Life!

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

Super Silent, Superior Life!

EC series GMS30CS-AU 50

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Super Silent, Superior Life!

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

CGT Stamford UCI 274 E1

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

130 KW / 165 KVA POWERED by

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET MPS180S-1E / MPS180-1E

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Model NA 2 L

PGKT / / / / / / / / / / / /

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

55 KW / 70 KVA POWERED by

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

DIESEL GENERATOR DATA SHEET

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

Diesel Generating Set 300KW / 375KVA 275KW / 344KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

TPD2250H6.3 TECHNICAL DATA

Technical specification

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

Standby Power(60Hz) Prime Power(60Hz) 513KW / 642KVA 456KW / 570KVA. Standard Features

PGDLS352KW 380/ / / / / / / / /

Diesel Generating Set

Diesel Generating Set 286KW/358KVA 260KW/325KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

kva kw Rated Speed Standard Voltage r.p.m V V Cos Phi Rated at power factor

204 KW / 254 KVA POWERED by

640 KW / 800 KVA POWERED by

Diesel Generating Set 520KW / 650KVA NA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

PGDLS / / / / / / / / /

APD-ULJ250. Standby Power

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

Prime Ratings (KW/KVA) 400/ / / /910

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Diesel Generating Set. Generator Ratings

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

WCS2000 / WCS2000S. Features: WCS Series

Model MP150 W W

500 KW / 625 KVA POWERED by

30 KW / 40 KVA POWERED by

WPS1000 / WPS1000S. Features: EP Series

Diesel Generating Set 315KW / 394KVA 280KW / 350KVA. Standby Power(50Hz) Prime Power(50Hz) Standard Features

NG904PES SERIES. Power Output Ratings. kva 904 kw 723 kva 808 kw 646. Standby Power (ESP) Prime Power (PRP)

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

GMS1400C / GMS1400CS. Features: EC Series

Rating Definitions and Conditions

FE - C KW / 650KVA 600KVA

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PGDLS / / / / / / / / /

Powered by Cummins Model:YN-95C

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Rating Definitions and Conditions

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

DIESEL GENERATOR SET MTU 18V2000 DS1400

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

600 KW / 750 KVA POWERED by

Standby Power(60Hz) Prime Power(60Hz) 1000KW / 1250KVA 900KW / 1125KVA. Standard Features

700 KVA / 550 KW POWERED by

70 KW / 90 KVA POWERED by

Volvo TAD733GE diesel engine Leroy Somer LSA 46.2 M5 alternator Standard Generator Features

kva kw r.p.m V V Cos Phi Ambient conditions of reference: 1000 mbar, 25ºC, 30% relative humidity. Power according to ISO 3046 normative.

APD-NG400. NG Standby Power

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Diesel Generating Set

Transcription:

Widely applied in Telecom, Industry, Rental, Outdoor Projects, Mining, Military, etc. GKP Series GKP 660KVA Generator Set Specification NO: GKP660KVA2012 c 2012 The Generator King (Pty) Ltd. Ultra Silent, Extended Life! Page - 1 - of 5

3-Phase, 50Hz@1500RPM Voltage kw kva Amps 380 532 600 Prime Power 400 532 600 Standby Power 380 583 660 400 583 660 Notes: Noise Level at 7 meters (dba) 73.5 1) Reference conditions: Ratings at sea level ;applicable de rating will apply at altitude 2) Standby Power: the maximum power available under varying loads. Only for standby and emergency use. No overload is permissible. Prime Power: the maximum power available under varying loads for continuous operation. A 10% overload is permissible for 1 hour every 12 hours. Features Excellent design and craftsmanship Designed with safety in mind Earth leakage protection Quick fix electrical power connections Extensive option list Well enclosed canopies with high protection against water and dust Benefits Beautiful appearance Low operating costs Ease of installation, operation, and maintenance Customization Good quality components Performance Specification and Craftwork Performance Specification Efficiency of Rated Power 96.3% TIF 50 Time needed from start-up to full load (inductive) 125 seconds THF 2% Time needed from start-up to 50% load (inductive) allowed 8 seconds 1.1 times overload operation time (hour) 1 Craftwork Voltage Regulation, steady state ±1% Voltage Regulation, transient state 20%-15% Voltage Settle Time Voltage Fluctuation Ratio 0.5% 5 seconds Frequency Regulation, steady state ±0.5% adjustable Frequency Regulation, transient state ±5% Frequency Settle Time 5 seconds Frequency Fluctuation Ratio 0.5% Recovery Time 0.5 seconds Telephone Interference, Electromagnetism Radio interference in compliance with BS800 and VED LEVELS G and N. Steel base frame with AV mounting standard 8h fuel tank with flexible rubber fuel tube, fuel level indicator and drainage Overall sprayed powder coating Whole set documents, including Installation Manual, Operation Manual, Circuit Diagram Criterion ISO8528-1995, GB2820-1997, YD/T502-2007 2006/42/EC and 2006/95/EC Page - 2 - of 5

Engine Specification Alternator Specification Brand Perkins - UK Brand Leroy Somer Model 2806C-E18TAG1A Model LSA 47.2L9 No. of Cylinders and Cycle 6L, 4 Stroke Rated Output (kva) 600 Induction System TCA Exciter Brushless Compression Ratio 14.5 Cooling Fan Cast alloy aluminum Displacement (L) 18.13L Bearing number Single Bore x Stroke (mm) 145 x 183 Windings 100% Copper Net weight (kg) 2050 Connection Type Star Connection Type of injection MEUI Insulation Class H Intake system Turbocharged, air to air charge cooled Winding Pitch 2/3 Cooling System Water Cooled Amortisseur Winding Full Fan Pusher A.V.R. Model AS440 Battery Voltage 24 V Voltage Regulation (no load- full load) ± 1.0% Type of oil 15W40 Underspeed Protection Standard Oil Capacity 62L Protection IP23 Phase Sequence A(U), B(V), C(W) Fuel Consumption (L/h) Governor Type 100% load 216 g/kw.h Excitation System Self-excited, PMG optional AmbientTemp. ( ) 40 Stator Rated Temp. ( ) 125 E Max. coolant friction head externalto engine (kpa) Thermostat adjusting temperature ( ) Min. opening pressure of radiator cap (kpa) Cooling System Coolant capacity-engine only (L) Fuel System 55 Type injection System MEUI 69 Fuel rail pressure (kpa) 22 69 58 Exhaust System Lubricating System Max. Back Pressure (kpa) < 6.9kPa Total system capacity (L) 62 Electrical System Oil pressure Starter (V) 24 Rated speed (kpa) 345-483 Battery charging system (A) 35 Page - 3 - of 5

Control System PLC-8610 GKP660KVA DSE-702 key manual start module is a manual engine control module designed to control the engine via a key switch and push buttons on the front panel. The module is used to start and stop the engine and indicate fault conditions, automatically shutting down the engine and giving a true first up fault condition of an engine failure. Standard Control Function Manual Engine Control Module Low Oil Pressure High Engine Temperature Auxiliary Shutdown Over speed Protection Protection hold-off timer Charge Failure warning PLC-8610 DSE-8610 control panel is applied Microprocessor control, with high stability and credibility Mains supply and generator operation monitoring Indicating operation status and fault conditions Multiple protections; multiple parameters display, like pressure, temp. Manual and automatic work mode selectable Real time clock for time and date display, overall runtime display, 99 log entries Overall power output display Integral speed/frequency detecting, telling status of start, rated operation, overspeed Communication with PC via RS485 OR RS232 interface, using MODBUS protocol. Engine ECU is available. Common USB cable is usable for parameter configuration. Multi-language is available. It can be translated for only one time and imported in forever. The idiom can also be changed after translation, eg. "Failure" to be "Malfunction". Dimension and Weight GKP660KVA Length Width Height, mm Weight (kg): 4692 1700 2487 6331 Page - 4 - of 5

Optional Engine Alternator Generator Set Fuel System Canopy Coolant heater Space heater AVR PMG with regulator Anti-damp and anti-corrosion treatment Anti-condensation heater Tools with the machine Low fuel level alarm Automatic fuel feeding system Trailer Container Lubricating System Exhaust System Cooling System Control Panel Voltages Oil with the machine Protection board from hotness Low frequency silencer Front heat protection 50 radiator Coolant (-30 O C) Remote control panel Automatic paralleling control panel Automatic Transfer Switch (ATS) 415/240V 400/230V 380/220V 220/127V 200-115V The Generator King (Pty) Ltd Head Office: 14 Lourens Street, Halfway House Midrand, South Africa Tel: 086 111 3847 Fax: 0866936326 E-mail: sales@genking.co.za Local Distributor Specification may change without prior notice. For more info, please contact Generator King or your local distributors. Page - 5 - of 5