Selection and application guide

Similar documents
Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard A fusible panelboards

Bussmann series Quik-Spec Coordination Panelboard

Quik-Spec Coordination Panelboard

Quik-Spec Coordination Panelboard Specifications

CUBEFuse. CUBEFuse catalog numbers (amps)

Quik-Spec Electrical Gear

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

Now - Up To 400A Mains!

Quik-Spec. Section Contents

Effective December 2015 Supersedes September 2013

Fused Coordination Panelboard

Low-Peak 600V Class RK1

Bussmann series Quik-Spec Power Module Switch elevator disconnect

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Specification made simple for selective coordination in a compact size

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Assembly not available for new installations.

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Selection and application guide

Low Voltage, Branch Circuit Rated Fuses

Fused Coordination Panelboard

Low voltage, branch circuit fuses

SECTION PANELBOARDS

Compact Circuit Protector

Product Specification Sheet #3LD2.1

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Panelboards Circuit Breaker / Lighting and Distribution

Power Mod. Standard Tapboxes.

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Compact Circuit Protector

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP)

N0N A 250V One-Time Class H Fuse

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

QMB Fusible Panelboards

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Pow-R-Line 3E Panelboard

Quik-Spec Coordination Panelboard

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

Compact Circuit Protector (CCP)

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Compact Circuit Protector (CCP)

PANELBOARDS SECTION 1

Compact Circuit Protector (CCP)

fastfax Rock Solid TM Load Centers General Information

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

footprint of traditional fusible switches

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Power Mod. Introduction.

NQOD Circuit Breaker Panelboards

Open-Style Power Distribution Blocks

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

MP Meter-Pak Meter Centers

Product Guide. QR Circuit Breaker. usa.siemens.com/circuitbreakers

Quick Connection Panel (QCP) Installation Guide

Three-Phase Ventilated

Section Contents. Disconnect Switches

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

SPEEDFAX TM 2011 Disconnect Switches Contents

WARREN COUNTY, N.Y. M/E REFERENCE

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

Heavy Duty Safety Switches

Totally Enclosed Non-Ventilated

UL Recognized power distribution blocks

Jefferson Public Works Shop Building 2011

NQOD Circuit Breaker Panelboards

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Product guide. Enclosed NEMA starters. Answers for industry.

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

Design Guide for Integration of Fixed-Mount Circuit Breakers

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Instruction sheet WARNING. October, 2014

Compact Circuit Protector (CCP) Application Note

Typical AEP Panelboard

A. Submit manufacturer's literature and technical data before starting work.

NEMA Pump Controls Class 82 slim line NEMA pump controller for the agricultural industry Answers for industry.

I power distribution. Blocks. challenges. Finger-Safe / FSPDB Series...I2. MPDB Open-Style PDBs... I4. MPDB62-MPDB63 (Mini) Open-Style PDBs...

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Typical ADP Panelboard

Loadcenters and Circuit Breakers. Contents. Overview. Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta

Lighting Panelboards. P2 Panelboards

Application guide. Tmax Link OEM UL 891 Switchboard Program

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

RCS1000 Data Sheet. RCS1000 Series Controllable Circuit Breaker Panel

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Type VBII Visible Blade Disconnect Switches

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

PANELBOARDS C1/C2 SECTION 6

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

Transcription:

Selection and application guide 30A 400A fusible panelboards Coordination Panelboard www.usa.siemens.com/fusiblepanel

Coordination panelboards Table of contents Subject Page Specifications 2-3 Enclosure types and voltages/systems 4 Main and feed through lugs, main disconnects 5-6 Neutral and ground assemblies 7 Dimensions and panelboard configurations 8-9 SCCPB branch disconnect, CUBEFuse replacement parts and performance data 10 Fuse curves 11 Coordination panelboard selection & application guide 1

Specifications Catalog symbol: SQSCP4 Description: Panelboards for commercial/industrial branch or service entrance applications on systems up through 600Vac. The SQSCP is especially designed to address the NEC Selective Coordination Requirements for Emergency, Legally Required Standby, Healthcare Essential Electrical and Critical Operation Power Systems (COPS) per NEC 700.27, 701.18, 517.26 and 708.54. Not for applications requiring AFCI protected circuits. The SQSCP is configured to order for the application. To confirm availability of options and constructions, contact your Siemens distributor. Ratings: Volts: 600Vac (or less), 125 Vdc Amps: 30, 60, 100, 200, 225, 400A SCCR: 20kA or 100kA @ 125Vdc See panelboard short circuit ratings table for AC ratings. Agency information: UL 67 Standard for panelboards UL 50/UL 50E Enclosures for electrical equipment CSA 22.2, No. 29-M1989 Panelboards and encl. panelboards UL listed, class CTL panelboard (meets 2002 NEC 408.1 limit of 42 overcurrent devices per panel) UBC and CBC Seismic Qualified and IBC Approved Main options: Main lug only (MLO) Fused main disconnect Non-fused main disconnect Branch disconnect options: 1-, 2-, and 3-pole 15, 20, 30, 40, 50, 60, 70, 90, and 100A rejecting branch disconnects (see table for details). Branch ampacity on 125Vdc panels limited to SCCPB 80A or less. Branch circuit positions: 18, 30 and 42 Neutral options: Unbonded and bonded 200A, 400A and 800A Ground options: Isolated and non-isolated Enclosures: NEMA 1 and NEMA 3R. Other ratings available. Consult factory. Spare fuse compartment: Six space spare fuse compartment standard on all models Panelboard short-circuit current ratings AC main options SCCR Main lug only 70-200A main disc. no fuses a (MLO) a or w/ Class J fuses 225-400A main disc. no fuses a or w/ Class J fuses SCCP_CF main disc. (60A) b DC Main lug only (MLO) a High 200kA 200kA 100kA 200kA 100kA Std. 50kA 50kA 50kA 50kA 20kA a Class J, T or RK1 fuses upstream, max amps = panel amps. b CUBEFuse disconnect 2 Coordination panelboard selection & application guide

Specifications SCCPB horsepower ratings Amp HP rating @ vac SCCPB disconnect rating 120 240 480 600 SCCPB-(poles)-15CF 15 0.5 3 5 7.5 SCCPB-(poles)-20CF 20 0.75 3 7.5 10 SCCPB-(poles)-30CF 30 1.5 5 15 10 SCCPB-(poles)-40CF 40 2 7.5 20 10 SCCPB-(poles)-50CF 50 3 7.5 20 10 SCCPB-(poles)-60CF 60 3 7.5 20 10 SCCPB-(poles)-70CF 70 3 15 30 40 SCCPB-(poles)-90CF 80 5 20 40 50 SCCPB-(poles)-100CF 100 5 20 50 50 Branch disconnects SCCPB part no. Poles SCCPB-1-15CF 1 SCCPB-2-15CF 2 SCCPB-3-15CF 3 SCCPB-1-20CF 1 SCCPB-2-20CF 2 SCCPB-3-20CF 3 SCCPB-1-30CF 1 SCCPB-2-30CF 2 SCCPB-3-30CF 3 SCCPB-1-40CF 1 SCCPB-2-40CF 2 SCCPB-3-40CF 3 SCCPB-1-50CF 1 SCCPB-2-50CF 2 SCCPB-3-50CF 3 SCCPB-1-60CF 1 SCCPB-2-60CF 2 SCCPB-3-60CF 3 SCCPB-1-70CF 1 SCCPB-2-70CF 2 SCCPB-3-70CF 3 SCCPB-1-90CF 1 SCCPB-2-90CF 2 SCCPB-3-90CF 3 SCCPB-1-100CF 1 SCCPB-2-100CF 2 SCCPB-3-100CF 3 Fuse amp range Max. SCCBP amp. 1-15 15 17.5-20 20 25-30 30 35-40 40 45-50 50 Non-indicating fuses (standard) STCF1RN, STCF3RN, STCF6RN, STCF10RN, STCF15RN STCF17-1/2 RN STCF20RN STCF25RN STCF30RN STCF35RN STCF40RN STCF45RN STCF50RN Indicating fuses (opt l) STCF6 STCF10 STCF15 STCF17-1/2 STCF20 STCF25 STCF30 STCF35 STCF40 STCF45 STCF50 60 60 STCF60RN STCF60 70 70 STCF70RN STCF70 80-90 90 STCF80RN STCF90RN STCF80 STCF90 100 100 STCF100RN STCF100 SCCPB disconnect can accept CUBEFuses with amp ratings less than or equal to the amp rating of the SCCPB disconnect. b Correct fit with SCCPB disconnect requires indicating CUBEFuses with date code R30 or later. Coordination panelboard selection & application guide 3

Enclosure/system types, AC & DC voltages NEMA 1 n Flush or surface mount. n Galvanized steel with removable end walls blank or with knockouts to order. n Box sizes: 20 W x 5.75 D x 33, 50, 59 or 69 H (510 W x 145 D x 838, 1270, 1500 or 1753mm H). Box can be rotated 180 to accommodate conduit feed. n Enclosure and chassis mounting instructions are found in supplied literature. n Chassis mounts directly onto studs in the enclosure. n Trim finished with gray powder coat paint over phosphatized steel (ANSI 61). n Door and door-in-door configurations with locks. n Door locks use key #2A1910-2. n Circuit directory card is located on the inside of the door. n Trim screws are concealed. AC voltages 1 phase, 2 wire n 120V 1 phase, 2 wire n 240V 1 phase, 2 wire 1 phase, 3 wire n 120/240V 1 phase, 3 wire A B 1 phase, 2 wire, Wye n 277V 1 phase, 2 wire N C A 1 phase, 2 wire, Delta n 480V 1 phase, 2 wire B C NEMA 3R n Surface mount only. n Finished with gray powder coat paint over phosphatized steel (ANSI 61). n Bottom feed only, no knockouts n Box sizes: 20 W x 7.7 D x 34.5, 51.5, 60.5 or 70.5 H (510 W x 195 D x 876, 1310, 1535 or 1791mm H). n Enclosure and chassis mounting instructions are found in supplied literature n Chassis mounts directly onto studs in the enclosure. n Gasketed door has vault handle with lock. n Door locks use key #2A1910-1. n Circuit directory card is located on the inside of the door. 1 phase, 3 wire, Delta n 240/480V 1 phase, 3 wire A N C B A B 3 phase, 4 wire, Wye n 208Y/120V 3 phase, 4 wire n 480Y/277V 3 phase, 4 wire n 600Y/347V 3 phase, 4 wire N C A 3 phase, 4 wire, Delta n 240/120V 3 phase, 4 wire n 480/240V 3 phase, 4 wire Busing Tin-plated copper with sufficient cross section to meet UL 67 temperature rise requirements. Distributed 1- & 3-phase busing All SCCPB branch disconnects can be mounted in any branch circuit position. B N C 3 phase, 3 wire, Delta n 240V, 3 phase, 3 wire n 480V, 3 phase, 3 wire n 600V, 3 phase, 3 wire n 240V, 3 phase, 3 wire, grounded B n 480V, 3 phase, 3 wire, grounded B n 600V, 3 phase, 3 wire, grounded B A A B C B 1 phase, 3 wire, Wye n 208Y/120V 1 phase, 3 wire n 480Y/277V 1 phase, 3 wire N C DC voltage 1 phase, 2 wire n 125Vdc, 2 wire (Up to 125Vdc, MLO option only, SCCPB 80A or less.) Single-phase 4 Three-phase Coordination panelboard selection & application guide N +125Vdc

Main and feed-through lugs and main disconnects 225-400 amp main lugs 200 amp main lugs Main mechanical lugs Main barrier cover open 600 KCMIL-4 AWG / 500 (56) Main mechanical lugs 60A panels 2-4 AWG / 50 (5.6) 6-10 AWG / 40 (4.5) 12-14 AWG / 15 (1.7) > 60 to 100A panels 300 KCMIL-1AWG / 375 (42) 2-6 AWG / 275 (31) Main sub-feed mechanical lugs Main barrier cover open 600 KCMIL-2 AWG / 375 (42) Main sub-feed mechanical lugs 200A panels 300 KCMIL-6 AWG / 275 (31) Smaller lugs for 60A panels not available Main compression (crimp) lugs a Main barrier cover open Wire range 600-250 KCMIL Main compression (crimp) lugs a Wire range 60A panels 8 AWG - 1/0 > 60A panels 300 KCMIL - 4 AWG Feed-through lugs Compression, mechanical and double (sub-feed) lugs are all available as feed-through lugs except if TVSS or loadside disconnect options are chosen. Lug ampacity ratings will be based upon panelboard ampacity rating. 225-400 amp loadside fused disconnect Available on: 18 and 30 branch position MLO 18 branch position non-fused main disconnect Mechanical lugs 300 KCMIL - 1 AWG / 375 (42) 2-8 AWG / 275 (31) Fuse mounting torque: 40 lb - in (4.5 N M) a Versa-Crimp VC6 crimp tool recommended for wire crimping. Coordination panelboard selection & application guide 5

Main disconnects Fused and non-fused, 1 and 3 phase 225-400 amp main disconnects Fused main disconnect, 1 and 3 phase 100-200 amp main disconnects Fused main disconnect, 1 and 3 phase Not available with DC ratings 600 KCMIL-2 AWG / 375 (42) Wire rating: 75 c, Cu only Not available with DC ratings 300 KCMIL-4 AWG / 200 (23) Wire rating: 75 c, Cu only Fuse mounting torque: 40 lb - in (4.5 N M) Non-fused main disconnect, 1 and 3 phase Fuse mounting torque: 40 lb - in (4.5 N M) Non-fused main disconnect, 1 and 3 phase Not available with DC ratings 600 KCMIL-2 AWG / 375 (42) Wire rating: 75 c, Cu only Not available with DC ratings 300 KCMIL-4 AWG / 200 (23) Wire rating: 75 c, Cu only 30-60 amp main disconnects 30-60A fused main disconnects (SCCP), 1 and 3 phase 3-phase 60A Single-phase 60A Not available with DC ratings 18-10 AWG single & dual / 20 (2.2) 8-6 AWG, single & dual / 35 (3.9) 4 AWG single / 35 (3.9) Wire rating: 75 c, Cu only 6 Coordination panelboard selection & application guide

Neutral and ground assemblies 200, 400, & 800A and connection wire torques 200A neutral assemblies Ground assemblies Unbonded Bonded Main terminal 300 KCMIL 1 AWG / 375 (42) Branch connections. See table below. Bar material: Aluminum Main terminal 300 KCMIL 1 AWG / 375 (42) Branch connections. See table below. Isolated Non-isolated See table below Bar material: Aluminum See table below Bar material: Aluminum 400A neutral assemblies Unbonded Bonded 800A neutral assemblies Unbonded Bonded Bar material: Aluminum Main terminal 600 KCMIL 4 AWG / 500 (56) Branch connections. See table below. Bar material: Aluminum Main terminal 600 KCMIL 4 AWG / 500 (56) Branch connections. See table below. Bar material: Aluminum Main terminal 600 KCMIL 4 AWG / 500 (56) Branch connections. See table below. Bar material: Aluminum Ground and neutral bars connection wire torques Wire* AWG Torque lb-in (N M) Neutral and ground assembly installation To facilitate installation and wiring, both neutral and ground assemblies can be installed on either side of the chassis with the desired orientation using the supplied screws. Assembly torques Torque to 25 lb-in (2.8 N M) Max. no. wires per opening Neutral GND Small opening 14 25-35 (2.8-3.9) 2 2 12 25-35 (2.8-3.9) 2 2 10 25-35 (2.8-3.9) 2 2 8 30-40 (3.4-4.5) 1 1 6-4 35-40 (3.9-4.5) 1 1 Large opening 14 25-35 (2.8-3.9) 3 3 12 25-35 (2.8-3.9) 3 3 10 35 (3.9) 3 3 8 30-40 (3.4-4.5) 1 1 6-4 35-40 (3.9-4.5) 1 1 3-1/2 40-50 (4.5-5.6) 1 1 * 60 / 75 c, Cu-Al Main terminal 600 KCMIL 4 AWG / 500 (56) Branch connections. See table below. Bar material: Aluminum Coordination panelboard selection & application guide 7

Dimensions NEMA 1 and NEMA 3R 0.3 21 (7/8, 1-1/8) Concentric KO 3.1 2.9 1.5 (1-3/4, 2, 2-1/2, 3, 3-5/8, 4-1/8) Concentric KO 1.1 2.2 NEMA 1 enclosures and interior 0.5 DETAIL A 11.3 7.4 Blank Endwall Knockout Endwall Enclosures Available with 2 Blank, 2 Knockout, or 1 Each Endwall Flush Mount DW + 3.0 Surface Mount DW Flush Mount DW + 3.0 Surface Mount DW SH A Ground Door Lock s Flush Mount H + 3.0 s CH MH Neutral RH H Surface Mount H DH Spare Fuse Compartment 20.0 16.0 2.0 D 0.25 Mounting Hole Emboss Front View (Door in Door Option Shown on Right) Box with Interior Side View of Box NEMA 3R enclosures Interior same as NEMA 1 0.2 0.5 SH 2.0 DETAIL B SCALE 1 : 4 Top End Wall (No Knockouts) B 0.65 7.68 D 0.6 2X H MH HC Box Interior Same as NEMA 1 13.0 DW Front View Side View Bottom End Wall (No Knockouts) 8 Coordination panelboard selection & application guide

Dimensions and panelboard configurations NEMA 1 and 3R enclosure dimensions Encl. type NEMA 1 NEMA 3R Dimensions (inches) Encl. height H HC MH CH DH RH SH DW D 33 33.0 N/A 29.0 26.0 28.9 25.0 2.0 20.0 5.7 50 50.0 N/A 43.0 40.0 37.9 39.0 3.5 20.0 5.7 59 59.0 N/A 52.0 49.0 46.9 48.0 3.5 20.0 5.7 69 69.0 N/A 62.0 59.0 56.9 58.0 3.5 20.0 5.7 33 33.0 34.5 35.5 26.0 28.9 25.0 2.0 20.0 6.3 50 50.0 51.5 52.5 40.0 37.9 39.0 2.0 20.0 6.3 59 59.0 60.5 61.5 49.0 46.9 48.0 2.0 20.0 6.3 69 69.0 70.5 71.5 59.0 56.9 58.0 2.0 20.0 6.3 Available panelboard configurations Based on enclosure height, panel amp rating and number of branch circuit positions Encl. height (in.) Panel amp rating 33 30 200 Branch positions 18 Available configurations main lug only, with or without feed-through lugs non-fused disconnect, no loadside options 30 main lug only, no loadside options 18 30 through 60A fused main disconnect with or without feed-through lugs or TVSS device 30 60 30 30 through 60A fused main disconnect with or without feed-through lugs or TVSS device 42 30 through 60A fused main disconnect with or without feed-through lugs or TVSS device 50 59 18 70 through 200A fused main disconnect with or without feed-through lugs or TVSS device 70 200 30 70 through 200A fused disconnect with or without feed-through lugs 18 main lug only with TVSS device non-fused disconnect, with feed-through lugs or TVSS device 30 200 30 main lugs only, with feed-through lugs or TVSS device non-fused disconnect, with or without feed through lugs 42 main lug only, with or without feed-through lugs or TVSS device non-fused disconnect, with or without feed-through lugs main lug only, with ot without feed through lugs or TVSS device 18 225 400A non-fused disconnect, with or without feed-through lugs 30 main lug only, with or without feed-through lugs 30 70 through 200A fused main disconnect, with TVSS device 70 200 42 70 through 200A fused main disconnect with or without feed-through lugs or TVSS device 30 200 42 non-fused disconnect with TVSS device main lug only with loadside disconnect 18 non-fused disconnect, with TVSS device 225 through 400A fused disconnect with or without feed-through lugs or TVSS device 225 400A main lug only, with TVSS device 30 225 through 400A fused disconnect, with no loadside options 42 main lug only, with or without feed-through lugs or TVSS device non-fused disconnect, with no loadside options 18 non-fused disconnect, with loadside disconnect 69 225 400A 30 42 main lug only with loadside disconnect 225 through 400A fused disconnect with feed-through lugs or TVSS device non-fused disconnect, with or without feed through lugs or TVSS device 225 through 400A fused main disconnect, with or without feed-through lugs or TVSS device Coordination panelboard selection & application guide 9

SCCPB branch disconnects, CUBEFuse replacement parts, and performance data I Fuse and disconnect performance data For details and specifications, access the following data sheets online at www.usa.siemens.com/panelboards J CUBEFuse Specifications Catalog Symbols: STCF_ (6-100A Indicating version) STCF_RN (1-100A Non-indicating version) Description: The CUBEfuse is a finger-safe, dual-element, time delay UL Class CF power fuse with Class J fuse electrical performance charcteristics. 10 Seconds minimum operating time at 500% rated current. I CCPB branch disconnects Poles Ampacity Part no. 1-pole 2-pole 3-pole J CUBEFuse fuses For CCPB part no. SCCPB-(# of poles)-15cf SCCPB-(# of poles)-20cf SCCPB-(# of poles)-30cf SCCPB-(# of poles)-40cf SCCPB-(# of poles)-50cf 15A, 20A, 30A, 40A, 50A, 60A, 70A, 90A, 100A Non-indicating part no. STCF(amps)RN STCF1RN, STCF3RN, STCF6RN, STCF10RN, STCF15RN STCF17-1/2 RN STCF20RN STCF25RN STCF30RN STCF35RN STCF40RN STCF45RN STCF50RN SCCPB-1-(amp)CF SCCPB-2-(amp)CF SCCPB-3-(amp)CF Indicating part no. STCF(amps) STCF6 STCF10 STCF15 STCF17-1/2 STCF20 STCF25 STCF30 STCF35 STCF40 STCF45 STCF50 SCCPB-(# of poles)-60cf STCF60RN STCF60 SCCPB-(# of poles)-70cf STCF70RN STCF70 SCCPB-(# of poles)-90cf STCF80RN STCF90RN STCF80 STCF90 SCCPB-(# of poles)-100cf STCF100RN STCF100 Ratings: Volts: 600Vac/300Vdc Amps: 1-100 (non-indicating version) 6-100 (indicating version) IR: 300kA RMS Sym. (UL) 200kA RMS. Sym (CSA) 100kA DC (UL & CSA) Agency Information: UL Listed Special Purpose Fuse: Guide JFHR, File E56412 CSA Certified Fuse: Class 1422-02, File 53787 CE compliance for the European Union low voltage directive Other Ratings/Specifications Watts Loss at rated current: STCF30: 3.99W STCF60: 6.23W STCF100: 9.51W Operating and Storage Temperature Range: 14 to 149 F(-10 to 65 C) Material Specifications: Case: Glass filled PES (Polyethersulfone) Terminals: Copper alloy Terminal plating: Electroless tin Indicator lens: PES (Polyethersulfone) (indicating version only) Indicator: Energetic chemical CUBEFuse, Low-Peak, Quik-Spec, QuikShip, and easyid are valuable trademarks of Cooper Industries in the United States and other countries. CCPB disconnect can accept CUBEFuses with amp ratings less than or equal to the amp rating of the SCCPB disconnect. b 1A indicating CUBEFuse not available. Correct fit with SCCPB disconnect requires indicating CUBEFuse with date code R38 or later. 10 Coordination panelboard selection & application guide

Fuse curves Time-Current Characteristic Curves Average Melt Current Limitation Curves Coordination panelboard selection & application guide 11

Notes: 12 Coordination panelboard selection & application guide

Siemens Industry, Inc. Building Technologies Division 5400 Triangle Parkway Norcross, GA 30092 1-800-241-4453 info.us@siemens.com www.usa.siemens.com/fusiblepanel Subject to change without prior notice Order No.: PBSA-CBCPB-0212 All rights reserved Printed in USA 2012 Siemens Industry, Inc. The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.