Certificate of Compliance

Similar documents
Certificate of Compliance

CABLE GLANDS AND CONNECTORS FOR THE IEC & NEC WORLD ATEX 95 & BEYOND ATEX 95 CMP PRODUCTS. Triple Certified

Certificate of Compliance

Certificate of Compliance

Certificate of Compliance

Cable Glands - American Series - NEC/IEC

TWO LEADING BRANDS, UNITED IN ONE PASSION: YOUR SAFETY.

Appleton s ATX product line includes a wide selection of both Increased Safety and Flameproof cable glands for use with unarmored and armored cable.

CERTIFICATE OF COMPLIANCE

Certificate of Compliance

Cable Connectors GET CONNECTED

Certificate of Compliance

APPLICATION MANUAL. Universal Explosionproof Two-Compartments Instrument Housing Type: XD-ID100, XD-ID100win, XD-ID100H, XD-ID100Hwin

Certificate of Compliance

AUTOMATION. Operator s Manual. RPM Series Float Level Sensors. Rev. E, 08/16 Doc Automation Products Group, Inc.

Control Device System NEC Series ConSig 8040

VALIADIS S.A. HELLENIC MOTORS

The safety you rely on.

Ex-proof proportional relief valves Direct or pilot operated, without transducer - ATEX, IECEx, EAC or CULUS

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

TERMINAL BOXES FOR HARSH & HAZARDOUS ENVIRONMENTS

ADE 4F. > For armoured cable > IP68. > Compliance. > EX Performance. > Nickel plated brass and stainless steel

ADE 6F ADE 6F. page 46

Mercmaster LED Series Luminaires Enclosed and Gasketed Fixtures

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Armoured / Un-armoured Cable Gland

ABG Cable Glands Installation Procedure

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

SynergEX Panelboards for Hazardous Locations

Capri ADE 6F - for Armoured Cable

Safety Instructions Proline Promass 300

Global Cable Gland Solutions

INTERNATIONAL METAL ENGINEERING

Cable Glands for Hazardous Areas

Motors and drives for applications in explosive atmospheres

Sensor boxes SRBE Key features and product range overview

Areamaster 1000 Floodlights Integrally Ballasted W HID For hazardous locations.

Assembly. Trunk IN + - S U, I U, I. Spur 1

Myers Hubs. Standard Finishes: Aluminum: Natural Zinc: Natural Stainless: Natural

GHG43 Series Control Stations

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Floodlight LED Series 6525

INSTRUCTION MANUAL (ATEX / IECEx)

Global Cable Gland Solutions

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22

Type Z & Ex pz purge and pressurization system

Flameproof Level Sensor (Flameproof F/S FP)

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Amphenol Cable Glands and Cord Grips Amphenol

Technical Data. Dimensions

Terminal Boxes Series 8125

New products Ex Equipment 2015

Terminal Boxes Series 8252/1

IECEx Certificate of Conformity

Flameproof Alternators

Position Switches Series 8060/2

INSTRUCTION MANUAL (ATEX / IECEx)

Cable and Cord Fittings Hazardous and Non-Hazardous

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Certificate of Conformity

EX CABLE GLANDS FOR HAZARDOUS AREAS ATEX & IECEX. Zones 1, 2, 21 and 22.

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

HTSB system System overview

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Kopex-Ex cable glands offer superior protection in hazardous environments

Position Switches Series 8070/2

Terminal Boxes in Stainless Steel SLS**.T

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

Series 3730 Electropneumatic Positioner Type

Floodlight LED Series 6525

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

BETA SWITCHES FOR HAZARDOUS AREA

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

Thread conversion products, breather drains and accessories

Floodlight Range Installation Guide

Stainless steel valves for water base fluids standard or ex-proof solenoid valves with Multicertification ATEX, IECEx, EAC or CULUS certification

SERIES 54 Inductive Proximity Sensor

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

OPERATING INSTRUCTIONS

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

STAINLESS STEEL PANEL MOUNT

IECEx Certificate of Conformity

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

High voltage flameproof induction motors The simplest solution for hazardous environments

Pratley Ezee-Fit Box Replacement Gaskets Replacement Gasket for the Pratley Ezee-Fit Box

Dimensions shown apply to both Stainless Steel and Mild Steel S1, SF*1 = 162, S2, SF*2, S2L, SF*2L = 170, S3, SF*3 = 250,

Ex-proof ISO cartridge valves multicertification ATEX, IECEx, EAC or North American certification CULUS directional control, ISO 7368

RS85 Vibrating fork level switch

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Load and Motor Switches, Load-Break Switches Series 8544

INTERNATIONAL METAL ENGINEERING

ILED Dorado. User Manual

Zone 1 Linear Range - Installation Guide

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

Transcription:

Certificate of Compliance Certificate: 2288626 Master Contract: 184585 Issued to: CMP Products Ltd Glasshouse St. St. Peters Newcastle Upon Tyne, NE6 1BS United Kingdom Attention: Dave Willcock The products listed below are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US or with adjacent indicator 'US' for US only or without either indicator for Canada only. Issued by: Jelena Dzeletovic Jelena Dzeletovic PRODUCTS CLASS 4418 85 CLASS 4418 05 - CABLE-Hardware - For Hazardous Locations-Certified to U.S. Standards - CABLE - Hardware - For Hazardous Locations CLASS 4418 85 - CABLE - Hardware - For Hazardous Locations US Requirements Class I, Div. 2, Groups A, B, C and D; Class II, Div. 2, Groups F and G; Class III, Div. 2; Type 4X; Oil Resistance II: Class I, Zone1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nr IIC Gc, Class I, Zone 20 AEx ta IIIC Da Series PX2K or PX2KW cable glands, integrally sealed (SL) for use only with Tray Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 10 full ISO metric threads. Series PXSS2K cable glands, integrally sealed (SL) for use with Tray Cable Type and braided-armored Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type DQD 507 Rev. 2012-05-22 Page: 1

EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 10 full ISO metric threads. Class I, Div. 2, Groups A, B, C and D; Class II, Div. 2, Groups F and G; Class III, Div. 2; Series PXB2KX cable glands, integrally sealed (SL) for use with braided-armored Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or RapidEx sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 10 full ISO metric threads. Class I, Div. 2, Groups C and D; Class II, Div. 2, Groups F and G; Class III, Div. 2; Type 4X; Oil Resistant II: Class I, Zone1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nr IIC Gc, Class I, Zone 20 AEx ta IIIC Da Series PX2K or PX2KW cable glands, integrally sealed (SL) for use only with Tray Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 5 full ISO metric threads. Series PXSS2K cable glands, integrally sealed (SL) for use with Tray Cable Type and Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 5 full ISO metric threads. Class I, Div. 2, Groups C and D; Class II, Div. 2, Groups F and G; Class III, Div. 2; Series PXB2KX cable glands, integrally sealed (SL) for use with braided-armored Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or RapidEx sealing DQD 507 Rev. 2012-05-22 Page: 2

compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 5 full ISO metric threads. Class I, Div. 1 and 2, Groups A, B, C and D; Class II, Div. 1 and 2, Groups E, F and G; Class III; Type 4X: Oil Resistant II: Class I, Zone1 AEx d IIC Gb, AEx e IIC Gb, Class I, Zone 2 AEx nr IIC Gc, Class I, Zone 20 AEx ta IIIC Da Series PX2KX and PX2K cable glands, integrally sealed (SL) for use with braided-armored or armoredjacketed Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M16 through M100 (Metric), when provided with NPT or a minimum of 10 full ISO metric threads. Class I, Zone 1, AE x d IIC; Class I, Zone 1, AEx e II, AEx nr II Series PXSS2K cable glands, integrally sealed (SL) for use with Extra Hard usage cord. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with a minimum of 5 full NPT threads or 10 full ISO metric threads Class I, Zone 1, AE x d IIC Series PXB2KX cable glands, integrally sealed (SL) for use with braided-armored or armored- jacketed Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or RapidEx sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with 5 full NPT threads or a minimum of 10 full ISO metric threads Class I, Zone 1, AE x d IIC, AEx nr II DQD 507 Rev. 2012-05-22 Page: 3

Series PX2KX cable glands, integrally sealed (SL) for use with braided-armored or armored- jacketed Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or RapidEx sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with 5 full NPT threads or a minimum of 10 full ISO metric threads CLASS 4418 05 - CABLE - Hardware - For Hazardous Locations Class I, Div. 2, Groups A, B, C and D; Class II, Div. 2, Groups F and G; Class III, Div. 2; Type 4X; Oil Resistant II: Series PX2K or PX2KW cable glands, integrally sealed (SL) for use only with Tray Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 10 full ISO metric threads. Series PXSS2K cable glands, integrally sealed (SL) for use with Tray Cable Type and braided-armored Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 10 full ISO metric threads. Class I, Div. 2, Groups A, B, C and D; Class II, Div. 2, Groups F and G; Class III, Div. 2; Series PXB2KX cable glands, integrally sealed (SL) for use with braided-armored Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or RapidEx sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 10 full ISO metric threads. DQD 507 Rev. 2012-05-22 Page: 4

Class I, Div. 2, Groups C and D; Class II, Div. 2, Groups F and G; Class III, Div. 2; Type 4X; Oil Resistant II: Series PX2K or PX2KW cable glands, integrally sealed (SL) for use only with Tray Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 5 full ISO metric threads. Series PXSS2K cable glands, integrally sealed (SL) for use with Tray Cable Type and Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 5 full ISO metric threads. Class I, Div. 2, Groups C and D; Class II, Div. 2, Groups F and G; Class III, Div. 2; Series PXB2KX cable glands, integrally sealed (SL) for use with braided-armored Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or RapidEx sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 5 full ISO metric threads. Class I, Div. 1,2 Groups A, B, C and D; Class II, Div. 1,2 Groups E, F and G; Class III, Div. 1,2; Type 4X: Oil Resistant II: Series PX2KX and PX2K cable glands, integrally sealed (SL) for use with braided-armored or armoredjacketed Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or RapidEx sealing compound, trade sizes ½ in NPT through 4 in NPT and M16 through M100 (Metric), when provided with NPT or a minimum of 10 full ISO metric threads. DQD 507 Rev. 2012-05-22 Page: 5

Class I, Div. 1,2 Groups C and D; Class II, Div. 1,2 Groups E, F and G; Class III, Div. 1,2; Type 4X: Oil Resistant II: Series PX2KX and PX2K cable glands, integrally sealed (SL) for use with braided-armored or armoredjacketed Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type 2122 sealing compound, trade sizes ½ in NPT through 4in NPT and M20 through M100 (Metric), when provided with NPT or a minimum of 5 full ISO metric threads. Class I, Div. 1, Groups A, B, C and D; Class II, Groups E, F and G; Class III; Type 4X; Oil Resistant II: Series PXSS2K cable glands, integrally sealed (SL) for use with Extra Hard usage cord. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or Rapid Ex sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with a minimum of 5 full NPT threads or 10 full ISO metric threads Ex d IIC Gb Series PXB2KX cable glands, integrally sealed (SL) for use with braided-armored or armored- jacketed Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or RapidEx sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with 5 full NPT threads or a minimum of 10 full ISO metric threads Series PX2KX cable glands, integrally sealed (SL) for use with braided-armored or armored- jacketed Marine Shipboard Cable Type. For vertical or horizontal mounting, for use with manufacturer s Type EP2122 or RapidEx sealing compound, trade sizes ½ in NPT through 4 in NPT and M20 through M100 (Metric), when provided with 5 full NPT threads or a minimum of 10 full ISO metric threads DQD 507 Rev. 2012-05-22 Page: 6

Notes: CLASS 4418 85 1. Cable gland connectors material may be of brass, aluminum or stainless steel. Connectors with metric entry threads are only suitable for Areas Classified in ZONES unless fitted with an approved Metric to NPT thread conversion adaptor. According to US (NEC) wiring method for the types of cables that can be used in Class I, Div. 1 and 2 and Class I, Zone 1and 2 Classified Areas, according to 60079-14 installation wiring method restrictions. When used with RapidEx sealing compound the product Series has suffix REX added to it. E.g. PX2KW becomes PX2KW-REX. Tray Cable in the report could be read as TC, TC-ER, TC-ER-HL (tray cable). Notes: CLASS 4418 05 Cable gland connectors material may be of brass, aluminum or stainless steel. Connectors with metric entry threads are only suitable for Areas Classified in ZONES unless fitted with an approved Metric to NPT thread conversion adaptor. According to C.E.C. wiring method for the types of cables that can be used in Class I, Div. 1 and 2 and Class I, Zone 1and 2 Classified Areas, according to 60079-14 installation wiring method restrictions. Shipboard Cables are for use on Marine Platform and or shipboards only and are subject to local authorities having jurisdiction on the installation. When used with RapidEx sealing compound the product Series has suffix REX added to it. E.g. PX2KW becomes PX2KW-REX. DQD 507 Rev. 2012-05-22 Page: 7

Tray Cable in the report could be read as TC, TC-ER, TC-ER-HL (tray cable). APPLICABLE REQUIREMENTS CAN/CSA-C22.2 No 0-M91 - General Requirements CAN/CSA-C22.2 No 18-04 - Outlet Boxes, Conduit Boxes, and Fittings CAN/CSA-C22.2 No 25-1966 - Enclosures for Use in Class II, Groups E, F and G Hazardous Locations CAN/CSA-C22.2 No 30-M1986 - Explosion Proof Enclosure for use in Class I Hazardous Locations Industrial Products CAN/CSA-C22.2 No.174-M1984 - Cables and Cable Glands for Use in Hazardous Locations CAN/CSA-C22.2 No.94-M91 - Special Purpose Enclosures CSA C22.2 No 60079-0-11 - Electrical Apparatus for Explosive Gas Atmospheres Part 0 -General Requirements CSA C22.2 No 60079-7-12 - Electrical Apparatus for Explosive Gas Atmospheres Part 7 - Increase Safety e CSA C22.2 No 60079-1-11 - Electrical Apparatus for Explosive Gas Atmospheres Part 1 - Flameproof CSA C22.2 No 60079-15-12 - Electrical Apparatus for Explosive Gas Atmospheres Part 15 - protection type "n" CSA C22.2 No 60079-31-12 - Explosive atmospheres -Part 31: Equipment dust ignition protection by enclosure t. CAN/CSA-E61241-1-1 - Electrical Apparatus for use in the presence of combustible dust- Part 1-1 ANSI/UL 514B Edition 5 - Conduit, Tubing, and Cable Fittings ANSI/UL 50 Edition 11 - Enclosures for Electrical Equipment ANSI/UL 2225 Edition 4 - Cables and Cable Fittings For Use in Hazardous (Classified) Locations ANSI/ISA 60079-31 (12.10.03)-2013 - Explosive atmospheres - Part 31: Equipment dust ignition protection by enclosure t. DQD 507 Rev. 2012-05-22 Page: 8

UL60079-0:09 - Electrical Apparatus for Explosive Gas Atmospheres Part 0 - General Requirements UL60079-7:08 - Electrical Apparatus for Explosive Gas Atmospheres Part 7 - Increase Safety e UL60079-1:09 - Electrical Apparatus for Explosive Gas Atmospheres Part 1 - Flameproof UL60079-15:13 - Electrical Apparatus for Explosive Gas Atmospheres Part 15 - Protection type "n" MARKINGS Permanently Die Stamped on each Body of the Gland: - Manufacturer name or trade mark - Catalogue number designation - Hazardous Location designation - Trade size and appropriate thread form - The letters "SL" (for integrally sealed gland) - Enclosure Type 4X and or IP66. - May be marked Oil Resistance II (where applicable). - Extra Hard Usage Cord Fittings (for Series PSS2K fittings only) - May be marked with the cord/cable diameter range (where applicable). - Certificate Number: CSA 10.2288626X (Applicable for A/Ex d and A/Ex e Marking). - CSA followed with the us or c us indicator (where applicable). Notes: Installation instruction sheet provided in each packaged unit containing the following information: 1. Instruction for mixing the compound. 2. Filling or assembly instructions, 3. Type of sealing compound. 4. Specification temperature of installation and curing time. DQD 507 Rev. 2012-05-22 Page: 9