User Guide. Model Insulation Tester / Megohmmeter

Similar documents
User Guide. Model Insulation Tester / Megohmmeter

Model Insulation Tester / Megohmmeter. User Manual

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

User's Manual Digital High Voltage Insulation Tester Model

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

DIGITAL INSULATION TESTER RS-5500/5505 INSTRUCTION MANUAL

USER MANUAL. Insulation Tester + DMM. Model MG320

Digital/Analog Megohmmeter Model 1026

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

True RMS Autoranging Multimeter

Autoranging Industrial Multimeter

Autoranging Multimeter

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Mini Multimeter with Non-Contact Voltage Detector (NCV)

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Safety design conforming to the following provisions

Mini Multimeter with Non-Contact Voltage Detector (NCV)

User's Manual. Earth Ground Resistance Tester. Model Introduction

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Safety design conforming to the following provisions

User's Guide. True RMS Multim eter. Extech 430

Table of Contents Title Page No.

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

DIGITAL RCD(ELCB) TESTER

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

Model Battery Powered Milliohm Meter

OPERATING INSTRUCTIONS

Dawson DDM190D. Digital Multimeter User s Manual

Digital Multimeter User's Manual

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

KMP Insulation-Continuity Tester. Users Manual

MEGOHMMETER. User Manual

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

5.2 PRE-OPERATION PROCEDURE WARRANTY

Non-Contact Phase Rotation Tester

Non-Contact Phase Rotation Tester

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

Solar Power Light Meter

4-WIRE EARTH RESISTANCE TESTER C1 ES P1 S. Max. AC 200V MICROPROCESSOR CONTROLLED TEST. Switch ON, TEST, SCROLL RESULTS 20Ω 200Ω 2000Ω OFF

3 PHASE TESTER & MOTOR ROTATION TESTER

OPERATING INSTRUCTION

Phase Sequence Tester

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

BM kv Digital Insulation Tester USER MANUAL

TRIPLETT. Model 310 Type C Type 9. Test Equipment Depot Washington Street, Melrose, MA TestEquipmentDepot.

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

OPERATING INSTRUCTION

USER MANUAL. White LED Light Meter. Model LT40. Additional User Manual Translations available at

Volt/mA Calibrator. Manual

Model UT601: OPERATING MANUAL

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

1.Safe testing IMPORTANT:

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

OPERATING INSTRUCTIONS

Users Manual. MegOhmMeter

PHASE ROTATION INDICATOR with OPEN PHASE CHECKER

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

Digital Multimeter AHMAD FOUAD ALWAN

HD110C Heavy-Duty Digital Multimeter

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

A.W. SPERRY INSTRUMENTS INC.

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

OPERATING INSTRUCTION

DIGITAL MULTIMETER INSTRUCTION MANUAL

Digital Formaldehyde Meter

Digital Insulation Resistance Testers. you can depend on

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

362 Clamp Meter. Users Manual

User's Guide. EzFlex Thermo-Anemometer. Model EZ30 UNITS MAX MIN AVG VEL

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

323/324/325 Clamp Meter

373 Clamp Meter. Users Manual

User's Guide. CO 2 Meter. Model CO250

365 Detachable Jaw True-rms Clamp Meter

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

Model UT602/603: OPERATING MANUAL

Transcription:

User Guide Model 380260 Insulation Tester / Megohmmeter

Introduction Congratulations on your purchase of Extech s Insulation Tester/Megohmmeter. The Model 380260 provides three test ranges plus continuity and AC/DC voltage measurement. A handy test lock feature and a data hold function are also included. This professional meter, with proper care, will provide years of reliable service. Safety 1. Circuits under test must be de-energized and isolated before connections are made (except for voltage measurements). 2. Circuit connections must not be touched during a test. Use extreme caution when working near bare conductors and bus bars. Accidental contact with conductors could result in electrical shock. 3. Use caution when working near voltages above 60VDC or 30VACrms. 4. After insulation tests, capacitors must be discharged. 5. Test leads (including alligator clips) must be in good working order, clean and without broken or cracked insulation. 6. When servicing, use only specified replacement parts. International Safety Symbols Caution, refer to this manual before using this meter Dangerous Voltages Meter is protected throughout by double or reinforced insulation Meter Description 1. LCD Display 2. Hold Button 3. Test Button 4. Rotary Switch 5. Backlight Button 6. Lock Button 7. Input Terminals 2

Operation Warning Ensure that the circuit under test does not include components that can be damaged by 1000VDC; such devices include power factor correction capacitors, low voltage mineral insulated cables, electronic light dimmers, and ballasts/starters for fluorescent lamps. Connecting Test Leads For all measurements, connect the red test lead to the V input terminal and the black test lead to the COM input terminal. Test Lead Check 1. Set the rotary switch to the 200 range. 2. Touch the test lead tips together. 3. Resistance should read less than 0.5 and the audio tone should sound. 4. With the leads not touching, the display should read infinity indicated by 1. 5. Readings displayed other than the readings described above are indicative of a test lead problem. The test leads must be replaced before using the meter. Failure to do so could result in damage to equipment and electrical shock. Insulation Resistance Measurements (Megohmmeter Tests) Warning: Do not perform Insulation Resistance measurements if AC Voltage is present on the device under test. 1. Connect the red test lead to the V input terminal; black lead to the COM terminal. 2. Set the function switch to the desired M test voltage position. 3. Connect the tips of the test leads to the equipment under test. If there is a voltage present, a constant beep will sound and the voltage will be displayed. 4. The display will show 1 until the TEST button is pushed. Press and hold the TEST button. The upper right display shows the test voltage applied and the flashing high voltage symbol will be displayed. The main display shows the resistance. 5. Keep the test leads connected to the equipment under test and release the TEST button. The circuit will discharge through the meter. Keep the test leads connected until the circuit is completely discharged and the upper right display shows 0 volts. Lock Function For hands-free operation, use the LOCK feature. 1. With the test leads connected to the equipment under test, simultaneously press the TEST and LOCK keys. 2. The LOCK icon will appear on the display. A beeper will sound every 2 seconds to indicate that the meter is in Lock mode. 3. Press the LOCK key to disable the Lock function and end the test. 3

Notes on IR (Megohmmeter) testing: 1. The maximum measurement range for the 380260 is 2000MΩ. Frequently, insulation resistance will exceed this value. When this happens, the display will indicate 1, meaning the resistance is very high and the insulation being tested is good. 2. If the device being tested is highly capacitive, the display will indicate an increasing resistance value over time. Always wait until the reading has stabilized before recording the value. AC/DC Voltage Measurement 1. Set the Rotary switch to the ACV or DCV position. 2. Connect the red test lead to the V terminal and the black test lead to the COM terminal. 3. Connect the test leads to the circuit under test. 4. Read the voltage value on the LCD. Resistance Measurement WARNING Do not run this test unless ACV = 0. Do not use this mode to check diodes. 1. Set the Rotary switch to the 200k position. 2. Connect the red test lead to the V terminal and the black lead to the COM terminal. 3. Connect the tips of the test leads to the circuit under test. 4. Read the resistance value on the display. Low Resistance (Continuity) Measurement 1. Set the Rotary switch to the 200Ω position. 2. Connect the red test lead to the V terminal and the black lead to the COM terminal. 3. Connect the tips of the test leads to the circuit under test. 4. Read the resistance value on the display. When the resistance of a circuit is less than approx. 40 the audible tone will sound. Auto Power Off To conserve battery life, the meter will automatically turn off after approx. 15 minutes of non-use. To turn the meter back on, turn the rotary switch to OFF, then to the desired function. Hold Function The hold function freezes the reading in the display. Press the HOLD key momentarily to activate or to exit the hold function Backlight Press the key for to turn on the display backlight function. The backlight will automatically turn off after 15 seconds. 4

Applications Measuring Power Tools and Small Appliances This section applies to any device under test that uses a line cord. For double insulated power tools, the meter s leads should be connected to the device s housing (chuck, blade, etc.) and the lines of the power cord. Testing AC Motors Disconnect the motor from the line by disconnecting the wires from the motor terminals or opening the mains switch. If the mains switch is opened, and the motor also has a motor-starter, then the starter must be held in the ON position. With the mains switch opened, the measured resistance will include the resistance of the motor wire and all other components between the motor and the main switch. If a weakness is indicated, the motor and other components should be checked individually. If the motor is disconnected at the motor terminals, connect one meter lead to the grounded motor housing and the other lead to one of the motor leads. Refer to diagram at below. Testing DC Motors 1. Disconnect the motor from the line. 2. To test the brush rigging, field coils and armature, connect one meter lead to the grounded motor housing and the other lead to the brush on the commutator. 3. If the resistance measurement indicates a weakness, raise the brushes off of the commutator and separately test the armature, field coils and brush rigging (one at a time). Leave one lead connected to the grounded motor housing while testing the motor components. This also applies to DC Generators. 5

Testing Cables 1. Disconnect the cable under test from the line. 2. Disconnect the opposite end of the cable to avoid errors as a result of leakage from other equipment. 3. Check each conductor to ground and/or lead sheath by connecting one meter lead to ground and/or lead sheath and the other meter lead to each of the conductors in turn. 4. Check insulation resistance between conductors by connecting meter leads to conductors in pairs. Refer to diagram at right. In the diagram, note that the 3-conductor cable has two wires shorted to the ground shield. This two-wire/shield connection is then connected to one side of the meter. The remaining conductor is connected to the other side of the meter. Specifications Range Specifications Accuracies are specified as % reading + digits at 23 o C ± 5 o C < 80% RH MEGOHMMETER RANGES Range Resolution Accuracy Terminal Voltage 200M 250V 0.1M ±3% + 5d 250V + 10% ~ -0% 200M 500V 0.1M ±3% + 5d 500V + 10% ~ -0% 0-1000M 1000VDC 1M ±3% + 5d 1000V + 10% ~ -0% 1000-2000M 1000VDC 1M ±5% + 5d 1000V + 10% ~ -0% 200M 250V 200M 500V Range Test Current Short Circuit Current 0-1000M 1000VDC 1000-2000M 1000VDC AC VOLTAGE (40Hz-400Hz) 1mA 250k (load) 500k (load) 1M Range Resolution Accuracy Input Impedance <1mA Overload Protection 750VAC 1V ±1.2% + 10d 10M 750Vrms DC VOLTAGE Range Resolution Accuracy Input Impedance Overload Protection 1000VDC 1V ±0.8% + 3d 10M 1000Vrms 6

RESISTANCE Range Resolution Accuracy Max. Open Circuit Voltage Overload Protection 200 0.1 ±1% + 2d 4.5V 250Vrms 200k 0.1k ±1% + 2d 3V 250Vrms General specifications Display Sampling rate Continuity beeper Over range indicator Zero adjust Low battery indicator Environmental Power source Operating conditions Storage conditions Dimensions Weight IEC 1010 Approvals LCD with dual display 2.5 readings per second Ω, short circuit current <200mA, open circuit voltage 4.5V 1 displayed Automatic Low battery symbol displayed when battery voltage is low Installation category II, Pollution Degree 2, Altitude up to 2000 meters, Indoor use only Six (6) 1.5 AA batteries 32 to 104 o F (0 to 40 o C); 80% RH 14 to 140 o F (-10 to 460 o C); <80% RH 7.8 x 3.6 x 1.9 (200 x 92 x 50mm) 24.6oz (700g) CAT III-1000V 7

Maintenance Battery Replacement When the low battery symbol appears on the LCD, the six 1.5V AA batteries must be replaced. 1. Turn the meter off and remove the test leads 2. Unsnap the tilt stand from the rear of the meter 3. Remove the four Phillips head screws holding the battery cover 4. Remove the battery compartment cover 5. Replace the batteries observing polarity 6. Affix the rear cover and secure the screws. 7. Reattach the tilt stand Cleaning Periodically wipe the case with a dry cloth. Do not use solvents or abrasives to clean this instrument. Copyright 2006 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. 8