Trimmer Auto Switch Series D- 7K/D-R K

Similar documents
Trimmer Auto Switch D-M9K/D-F7K/D-Y7K D-RNK/D-RPK

Trimmer Auto Switch D-F7K/D-Y7K D-RNK/D-RPK

Low Differential Pressure Sensor ±1% F.S.

Magnetic Field Resistant 2-color Indication Type Solid State Auto Switch

No.EX -OME0016-A PRODUCT NAME. SI unit. MODEL / Series / Product Number EX140-SDN1

Solid State Auto Switch

0.1 mm. Actuator Position Sensor. D-MP Series. Actuator stroke position is output with an analog signal. Repeatability IP67.

Low Torque Metal Seal Type Rotary Joint. MQR Series

10 PSE53 0 M5. Port size. M5 x 0.8 ø6 reducer 1/4-inch reducer. the cable at the time of shipment. 10-PSE to -101 kpa

Dome-Loaded Pressure Reducing BD-Series

Solid State Auto Switch D-M9#A#


High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Technical information for LFU20-Z07-3A-X2

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

1.8 w Port Solenoid Valve Direct Operated Poppet Type. New. Series VT307 CAT.ES11-107A. Power consumption

Dual-Rod Cylinder Compact Type

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Pressure Sensor for General Fluids PSE570/573/574

(Actual size) 2 switches 10 switches. Push Adjust to the set-value by the or button.

Operation Manual. Model name. MRHQ Rotary Gripper. Part number / Series MRHQ10,16,20,25

High Vacuum Solenoid Valve PRODUCT NAME. XSA Series MODEL/ Series

Doc. no.vn-omm0001-c. Coolant valve PRODUCT NAME. VNC/VNH Series MODEL / Series / Product Number

Base Mounted Series VQZ100/200/300. Nil. W Note) Compliant. Electrical entry. (DC speci- fication) terminal terminal. Coil voltage 24VDC

Mini Free Mount Cylinder

SI unit for AS-Interface EX250-SAS#

49.5 mm Overall. 30 mm MXZ ø20. Compact. Compact Cylinder with Linear Guide. MXZ Series CAT.ES20-236A. ø12, ø16, ø20, ø25. MXZ ø20, 10 mm stroke.

Doc. no.vn -OMA0002-D. Process valve PRODUCT NAME. VNA Series MODEL / Series / Product Number

Digital Flow Switch (Remote type sensor unit)

Free position locking flat and compact cylinder UFCD Series

Series MHS. 2, 3, 4 Finger Air Gripper D-F9P. Auto Switch Common Specifications. Auto Switch Common Specifications. Lead Wire Color Changes

This filter enables direct exhaust of air in a clean room! (Cleanliness class 4*: ISO ) (* Based on SMC s measuring conditions.

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Mounting style. B Basic style L Foot style. Shaft type. S Single shaft W Double shaft Not available for ø30. Size 11 - C D R A 1 B S C - A53

Series MXH. Compact Slide. ø6, ø10, ø16, ø20

Inductive Proximity Sensor

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Coolant valve. SGC/SGH Series

Series DV

Digital Flow Switch (Remote type monitor unit)

Pressure Relief 3 Port Valve With Locking Holes

Specifications MHC2-10D MHC2-16D MHC2-20D MHC2-25D MHC2-10S. Double acting MHC2-16S. Single acting MHC2-20S MHC2-25S. Angular style air gripper

2-Color Display High-Precision Digital Pressure Switch

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Dual-Rod Cylinder Compact Type

SI unit for Ethernet POWERLINK

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

Digital Flow Switch (Integrated display type)

9.8 mm. Digital Pressure Switch. 3-step setting. RoHScompliant. Series ZSE10(F)/ISE10. Vertical mounting space reduced to approx.! Reduced in depth!

AS Series. 4.0 g. Weight: Approx. 27% lighter. Flow Rate Reproducibility. Larger Knob. Easy Identification of Product Type. 5.5 g.

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

HS6B Series Subminiature Interlock Switch

CAT.ES A -UK. Low Profile Air Gripper. Series MHF2. Low profile air gripper with space-saving design is newly released.

ø20, ø32 ø50, ø63, ø80 How to Order Piping direction Flange side Nil Cylinder stroke 15mm 15 (RSH20) 20mm 20 (RSH32) 30 D L Cylinder stroke

HS6B Series Sub-Miniature Interlock Switch. Direct Opening

Electric Cylinder. LZB/LZC Series. It can be operated like an air cylinder. LZB Series. LZC Series LEF LEJ LEL LEM LEY LES LER LEH 25A- LEC

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

A Metal Head That's. Highly Durable and Provides Long-distance Detection. mm 7(M18 Model) Proximity Sensor with All-stainless Housing E2EF NEW

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

2NC (slow-action) Direct. Model. opening

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual

KV series. Innovatively detachable Manifold Block. Smart Solenoid Valve (plug-in type, D-SUB multi-connector type)

Digital display Pressure range ON/OFF output Linear output Model

Digital Flow Switch. How to Order PF2D C. Port size: (inch) PF2D504 PF2D520 PF2D540

69% 30.5 mm 16 mm. Compact Guide Cylinder. Compact. lighter 0.32 kga0.1 kg (Compared with the current MGP-Z series, ø16, 10 mm stroke) Weight

l/min (Comparison under Nozzle diameter: ø0.3, Vacuum pressure: 60 kpa) New

NAMUR Interface 5 Port Solenoid Valve

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Mini Free Mount Cylinder

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Compact Type Dual-Rod Cylinder

Doc. No. IZ -OML0002-B OPERATION MANUAL. Ionizer PRODUCT NAME:

Series 10-ZSE40A(F)/10-ISE40A

Solid State Relays G3NA. Model Number Structure. Model Number Legend

SI unit for EtherCAT. EX260 Series

SeriesMHZL2 How to Order

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

2.5mm. Output configuration NPN. 2.5mm PNP. 2.5mm

Series CRJ. Mini-Rotary Actuator. Rack-and-Pinion Type/Size: 05, 1

Digital Flow Switch (Integrated display type)

EX-F70 SERIES EX-F60 SERIES

Air Catch Sensor ISA2

Solid State Relays G3RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. SSR and Socket Combinations

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Doc. No.VT307 -OMH0001-C. 3 Port Direct Operated Solenoid Valve PRODUCT NAME. VT307 Series MODEL/ Series

Vacuum pump system type

High-speed detection even a little liquid leak

Balancing Unit BBS Series

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

10 VQ F. Nil Latching type: Push-locking type (Tool required) B. Nil. Electrical entry

Digital Pressure Switch

EX##-OMN0011-A. SI unit for EtherCAT PRODUCT NAME. EX260 Series MODEL/ Series

Digital Flow Switch PFM7##

Digital Gap Checker. ISA3 series

HS1L Interlock Switches with Solenoid

45% 6.5 mm. 6 mm. 4 mm. Compact Cylinder. Compact. lighter. JCQ Series CAT.ES20-239C. Weight. ø12, ø16, ø20, ø25, ø32, ø40, ø50, ø63, ø80, ø100

Digital pressure switch for energy-saving control ejector

Electric Cylinders. It can be operated like an air cylinder. Directional control driver like a solenoid valve

Ejector Valve Unit Series ZYY/ZYX

Transcription:

CAT.ES0-180 B Trimmer Auto Switch Series D- K/D-R K Large work piece OUT1 and OUT are adjustable separately. OUT1 Trimmer OUT Trimmer OUT Medium work piece Small work piece Operating range of sensor (LED of sensor is on.) OUT1 Detecting range Output ON = Green LED is on. Adjustable by trimmer OUT Detecting range Output ON = Orange LED is on. Adjustable by trimmer No work piece Small work piece Medium work piece Large work piece OUT1 0. mm 0. Minimum width to detect With one switch, various sized work pieces can be detected by the difference of more than 0. mm. on applied actuator. From 0. mm to detectable width dependant One auto switch allows work pieces to be distinguished easily. OUT OUT1 Examples To confirm depth of the machined hole To judge height of a work piece Can be mounted on a standard actuator. Direct mounting / Rail mounting Joining of connector Sensor and amplifier can be connected without restriction. Two mounting types (Amplifier unit) DIN rail mounting / Direct mounting IP (Sensor unit) IP0 for amplifier

Trimmer Auto Switch Series D- K/D-R K Sensor unit Direct mounting type Rail mounting type Specifications Sensor Unit Model Mounting Applicable amplifier unit Status indication Electrical entry D-FK D-YK Rail mounting Direct mounting D-RNK, D-RPK Operating position: Red light is ON. Suitable operating position: Green light is ON. Grommet Amplifier unit Internal Circuit Sensor Unit 1 D- K Switch main circuit Detective sensor Amplifier Unit D-RNK Sensor Brown White 3 Blue Black 1 D-RPK Sensor Brown White 3 Blue Black 1 Main circuit Main circuit DC (+) (Brown) OUT 1 (Black) OUT (White) DC ( ) (Blue) DC (+) (Brown) OUT 1 (Black) OUT (White) DC ( ) (Blue) Vsw (Brown) GND (Blue) SOUT 1 (Black) SOUT (White) Load Load Load Load 1 to VDC 1 to VDC Lead wire Oilproof heavy-duty vinyl cord ø3. 0.1 mm With one e-con connector Note) cores 3 m Impact resistance 980 m/s Insulation resistance Withstand voltage Ambient temperature Enclosure Weight 0 MΩ or more (00 VDC Mega) between lead wire and case 1000 VAC for 1 min. (between lead wire and case) 10 to 0 C IP 8 g (with connector) Note) The e-con connector is not attached to the lead wire. They will be supplied loose in the same shipment. Amplifier Unit (with Sensor Unit) Model D-RNK Applicable sensor unit Application Power supply voltage Current consumption Output specification Load voltage Load current Internal voltage drop Leakage current Response time Status indication Electrical entry Connection to sensor Power supply/ output cable Lead wire Impact resistance Insulation resistance Withstand voltage Ambient temperature Enclosure Weight D-FK, D-YK For relay and PLC 1 to VDC 0 ma or less NPN open collector outputs PNP open collector outputs 8 VDC or less 80 ma or less 1. V or less 100 µa or less 1 ms or less READY: Red light emitting diode when the piston position detected. (When the sensor is connected). OUT 1: Green light emitting diode when ON OUT : Orange light emitting diode when ON e-con connector Grommet D-RPK Oilproof heavy-duty vinyl cord ø3. 0.1 mm cores 3 m 98 m/s 0 MΩ or more (00 VDC Mega) between lead wire and case 1000 VAC for 1 min. (between lead wire and case) 10 to 0 C IP0 0 g

Trimmer Auto Switch Series D- K/D-R K Descriptions Sensor unit w q q Sensor Unit 1 Indicator light Red light turns ON when sensor detects the magnet field. Green light is ON during the suitable position to detect the magnetic field (including most sensitive position). ø3. mounting hole M. x L slotted set screw Fixes the sensor to the actuator. D-FK Amplifier unit q w e r t w D-YK y u Amplifier Unit 1 Output (OUT1) indication: Green Illuminates when OUT1 outputs. OUT1 adjusting trimmer Adjusts the output range of OUT1 when sensor unit detects the magnetic field. 3 Output (OUT) indication: Orange Illuminates when OUT outputs. OUT adjusting trimmer Confirmation of detection at sensor unit (READY): Red Offset adjusting trimmer (ADJ) Adjusts the output range of OUT when sensor unit detects the magnetic field. Illuminates when sensor unit is detecting the magnetic field. While its lighting, output ranges of OUT1 and OUT are adjustable. Adjusts the sensor unit at the time of connection. Once adjusts, no need to re-adjust as long as the sensor unit is not replaced. Adjustment must be undertaken while the sensor unit is removed from the actuator. Refer to the operation manual for details. D-R K Confirmation of offset adjustment (OFFSET): Red Illuminates when offset adjustment is completed. Refer to the operation manual for how to adjust/set. Applicable Actuators and Operation Range (Angle) The operating ranges are provided as guidelines including the hysteresis and are not guaranteed value. Please consult with for alternative actuators than those shown below. Sensor Unit D-YK Air Gripper Parallel gripper Wide opening Parallel gripper Parallel gripper Parallel gripper Angular gripper 180 opening/closing Air Cylinder Compact guide cylinder Non-rotating rod double power cylinder Air cylinder Model Sensor Unit D-FK Air Cylinder Model Air cylinder Air cylinder Compact cylinder Compact cylinder/guide rod type Plate cylinder 3 position cylinder Rotary clamp cylinder MHZ MHL MHS ( finger) MHS3 (3 finger) MHS ( finger) MHC MHW MGP MGZ CA CJ CM CQ CQM MU RZQ MK/MK 10. 10.8 30 to 10 1. Bore size 1 1 0 3 0 0 3 8 8. 10. 8 11 8. 1.... 8. 8 8. 30 to 10 30 to 10. to 10 88 to to 8 to 1 to 30 to 3... Bore size 1 0 3 0 0 3 80 100 1. 3. 3. 3. 3... (mm or ) 80 100 (mm) 10 10..

Series D- K/D-R K Dimensions Sensor unit D-FK 8 ø3. 11 1 D-FK Most sensitive position D-YK Amplifier unit D-R K. 1. 3000. 1 8. ø3. 1 3. 3000. 3. 8.. M. x L ø3.. ø3. 33 3000 10. 0. D-YK 1. Most sensitive position DIN rail Supplied by customer. 30 1.1 D-RNK -ø3. 3 Connector for sensor e-con

Trimmer Auto Switch Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These instructions indicate the level of potential hazard by labels of "Caution", "" or "Danger". To ensure safety, be sure to observe ISO 1 Note 1), JIS B 830 Note ) and other safety practices. Explanation of the Labels Labels Explanation of the labels Danger Operator error could result in serious injury or loss of life. Caution Operator error could result in injury Note 3) or equipment damage Note ). In extreme conditions, there is a possible result of serious injury or loss of life. Note 1) ISO 1: Pneumatic fluid power General rules relating to systems Note ) JIS B 830: General Rules for Pneumatic Equipment Note 3) Injury indicates light wounds, burns and electrical shocks that do not require hospitalization or hospital visits for long-term medical treatment. Note ) Equipment damage refers to extensive damage to the equipment and surrounding devices. Selection/Handling/Applications 1. The compatibility of the pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications. Since the products specified here are used in various operating conditions, their compatibility for the specific pneumatic system must be based on specifications or post analysis and/or tests to meet the specific requirements. The expected performance and safety assurance are the responsibility of the person who has determined the compatibility of the system. This person should continuously review the suitability of all items specified, referring to the latest catalog information with a view to giving due consideration to any possibility of equipment failure when configuring a system.. Only trained personnel should operate pneumatically operated machinery and equipment. Compressed air can be dangerous if handled incorrectly. Assembly, handling or repair of pneumatic systems should be performed by trained and experienced operators. (Understanding JIS B 830 General Rules for Pneumatic Equipment, and other safety rules are included.) 3. Do not service machinery/equipment or attempt to remove components until safety is confirmed. 1. Inspection and maintenance of machinery/equipment should only be performed once measures to prevent falling or runaway of the driver objects have been confirmed.. When equipment is removed, confirm that safety process as mentioned above. Turn off the supply pressure for this equipment and exhaust all residual compressed air in the system, and release all the energy (liquid pressure, spring, condenser, gravity). 3. Before machinery/equipment is restarted, take measures to prevent quick extension of a cylinder piston rod, etc.. Contact if the product will be used in any of the following conditions: 1. Conditions and environments beyond the given specifications, or if product is used outdoors.. Installation on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical equipment, food and beverages, recreation equipment, emergency stop circuits, clutch and brake circuits in press applications, or safety equipment. 3. An application which has the possibility of having negative effects on people, property, or animals, requiring special safety analysis.. If the products are used in an interlock circuit, prepare a double interlock style circuit with a mechanical protection function for the prevention of a breakdown. And, examine the devices periodically if they function normally or not. Exemption from Liability 1., its officers and employees shall be exempted from liability for any loss or damage arising out of earthquakes or fire, action by a third person, accidents, customer error with or without intention, product misuse, and any other damages caused by abnormal operating conditions.., its officers and employees shall be exempted from liability for any direct or indirect loss or damage, including consequential loss or damage, loss of profits, or loss of chance, claims, demands, proceedings, costs, expenses, awards, judgments and any other liability whatsoever including legal costs and expenses, which may be suffered or incurred, whether in tort (including negligence), contract, breach of statutory duty, equity or otherwise. 3. is exempted from liability for any damages caused by operations not contained in the catalogs and/or instruction manuals, and operations outside of the specification range.. is exempted from liability for any loss or damage whatsoever caused by malfunctions of its products when combined with other devices or software. Back page 1

Trimmer Auto Switch Precautions 1 Be sure to read this before handling. For Auto Switch Common Precautions, refer to Precautions for Handling Pneumatic Devices (M-03-E3A). Design and Selection 1. Confirm the specifications. Read the specifications carefully and use this product appropriately. The product may be damaged or malfunction if it is used outside the range of specifications of current load, voltage, temperature or impact.. Take precautions when multiple cylinders are used close together. When multiple auto switch cylinders are used in close proximity, magnetic field interference may cause the switches to malfunction. Maintain a minimum cylinder separation of 0 mm. (When the allowable separation is indicated for each cylinder series, use the specified value.) 3. Keep the wiring as short as possible. Use a wire 3 m or shorter between the sensor and amplifier. Although wire length of power supply/output cable should not affect switch function, use a wire 100 m or shorter.. Take precautions for the internal voltage drop of the switch.. Pay attention to leakage current. Although a varistor for surge protection is connected at the output side of a trimmer auto switch, damage may still occur if the surge is applied repeatedly. When a load, such as a relay, solenoid, which generates surge is directly driven, use a type of switch with a built-in surge absorbing element.. Cautions for use in an interlock circuit. When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to avoid trouble by providing a mechanical protection function, or by also using another switch (sensor) together with the trimmer auto switch. Also perform periodic maintenance and confirm proper operation.. Ensure sufficient clearance for maintenance activities. When designing an application, be sure to allow sufficient clearance for maintenance and inspections. Mounting and Adjustment 1. Do not drop or bump. Do not drop, bump or apply excessive impacts (980 m/s or more for sensor unit and 98 m/s or more for amplifier unit) while handling. Although the body of the switch may not be damaged, the inside of the switch could be damaged and cause a malfunction.. Do not carry a cylinder by the auto switch lead wires. Never carry a cylinder by its lead wires. This may not only break the lead wires, but it may cause internal elements of the switch to be damaged by the stress. 3. Mount switches using the proper tightening torque. When a switch is tightened beyond the range of tightening torque, the mounting screws, mounting bracket or switch may be damaged. On the other hand, tightening below the range of tightening torque may allow the switch to slip out of position. Wiring 1. Avoid repeatedly bending or stretching lead wires. Broken lead wires will result from applying bending stress or stretching forces to the lead wires.. Be sure to connect the connector for sensor to the amplifier before power is applied. 3. Confirm proper insulation of wiring. Be certain that there is no faulty wiring insulation (contact with other circuits, ground fault, improper insulation between terminals, etc.). Damage may occur due to excess current flow into a switch.. Do not wire with power lines or high voltage lines. Wire separately from power lines or high voltage lines, avoiding parallel wiring or wiring in the same conduit with these lines. Control circuits, including auto switches, may malfunction due to noise from these other lines.. Do not allow short circuit of loads. Output is automatically stopped when the protection circuit is working, as the output unit registers any excess current flow, if loads are short circuited. Should this occur, shut off the power supply, remove the cause of this excess current flow and switch on the power again. Take special care to avoid reverse wiring between the power supply line (brown) and the output line (black, white).. Avoid incorrect wiring. If the connections are reversed (power supply line + and power supply line ), the switch will be protected by a protection circuit. However, if the power supply line ( ) is connected to the black, white wire, the switch will be damaged. Operating Environment 1. Never use in an atmosphere with explosive gases. The structure of trimmer auto switches is not designed to prevent explosion. Never use in an atmosphere with an explosive gas since this may cause a serious explosion.. Do not use in an area where a magnetic field is generated. Trimmer auto switches will malfunction or magnets inside cylinders will become demagnetized. 3. Do not use in an environment where the trimmer auto switch will be continually exposed to water. Although the sensor units of trimmer auto switches satisfy the IEC standard IP structure (JIS C090: waterproof construction), do not use trimmer auto switches in applications where continually exposed to water splash or spray. Poor insulation or swelling of the potting resin inside switches may cause malfunction. (Amplifier part D-RNK and RPK: IP0) Back page

Trimmer Auto Switch Precautions Be sure to read this before handling. For Auto Switch Common Precautions, refer to Precautions for Handling Pneumatic Devices (M-03-E3A). Operating Environment. Do not use in an environment with oil or chemicals. Please consult with if auto switches will be used in an environment with coolant, cleaning solvent, various oils or chemicals. If auto switches are used under these conditions for even a short time, they may be adversely affected by improper insulation, malfunction due to swelling of the potting resin, or hardening of the lead wires.. Do not use in an environment with temperature cycles. Please consult with if switches are used where there are temperature cycles other than normal temperature changes, as they may be adversely affected.. Do not use in an area where surges are generated. When there are units (solenoid type lifter, high frequency induction furnace, motor, etc.) which generate a large amount of surge in the area around cylinders with trimmer auto switches, this may cause deterioration or damage to the circuit element inside the switch. Take measures against sources of surge generation and take caution to crossed lines.. Avoid accumulation of iron powder or close contact with magnetic substances. When a large amount of ferrous powder such as machining chips or spatter is accumulated, or a magnetic substance is brought into close proximity with an auto switch cylinder, it may cause the auto switch to malfunction due to a loss of the magnetic force inside the cylinder. 8. Take measures against freezing when operating at C or less. 1. Perform the following maintenance periodically in order to prevent possible danger due to unexpected trimmer auto switch malfunction. 1) Secure and tighten switch mounting screws. If screws become loose or the mounting position is dislocated, retighten them after readjusting the mounting position. ) Confirm that there is no damage to lead wires. To prevent faulty insulation, replace switches or repair lead wires, etc., if damage is discovered. Maintenance Other 1. Please consult with concerning water resistance, elasticity of lead wires, and usage at welding sites, etc. Caution D-YK. Connection of sensor connector Cut the sensor cable as illustrated to the right. Referring to the table below, insert each lead wire of the cable at the position marked with a number corresponding to the color of the lead wire. Connector no. 1 3 Lever Sheath D-RNK 0 mm or more Insulator Wire core color Black (SOUT1) Blue (GND) White (SOUT) Brown (Vsw) Confirm that the numbers on the connector match the colors of the wires and that the wires are inserted to the bottom. Press part A by hand for temporary fixing. Press in the central part of Part A vertically with a tool such as pliers. A sensor connector cannot be taken apart for reuse once it is crimped. If the wire arrangement is incorrect or if the wire insertion fails, use a new sensor connector. Part A Wiring 1. Connection and removal of connector Hold the lever and connector body with two fingers and insert the connector straight into the pin until it is locked with a click sound. To remove the connector, pull it out straight while pressing the lever with one finger. Use a sensor conector, ZS-8-CA-3 (1 pc.) or e-con connectors as shown below. Manufacturer Sumitomo 3M Limited Tyco Electronics AMP K.K. OMRON Corporation Part no. 310-31-000FL 13- XNA-130 For detailed information about e-con connectors, please consult with the manufacturers of the respective connectors. Back page 3

Trimmer Auto Switch Precautions 3 Be sure to read this before handling. For Auto Switch Common Precautions, refer to Precautions for Handling Pneumatic Devices (M-03-E3A). Caution Use mounting screws (M3 x 1L) or DIN rail (3 mm width). Adjust offset before mounting of the amplifier unit. 1. Mounting with screws Tighten two M3 x 1L mounting screws at a tightening torque of 0. to 0. N m. Mounting surface should be flat and even. A bumpy or uneven mounting surface can result in damage to the case. Mounting of Amplifier Unit. Mounting and removal to DIN rail Mounting Hook the claw 1 of the amplifier body to the upper part of DIN rail, press down and push horizontally until the claw is locked with a click sound. Claw 1 Removal To remove from the DIN rail, push the amplifier body upward and then pull it horizontally to release from the claw 1 side. Washer Claw M3 x 1L In the case of mounting to the DIN rail, recommends the following end plates: as detailed in the table on the right. Consult each manufacturer for the handling and details of end plate. Manufacturer OMRON Corporation IDEC Corporation Part no. PFP-M BNL 3. Refer to each applicable actuator s catalog for the mounting of sensor unit. Safety Instructions Be sure to read Precautions for Handling Pneumatic Devices (M-03-E3A) before using. 1-1- Shimbashi, Minato-ku, Tokyo 10-89 JAPAN Tel: 03-30-0 Fax: 03-308-80 URL http://www.smcworld.com 00 Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. D-DN 1st printing HY printing JY 10DN Printed in Japan. This catalog is printed on recycled paper with concern for the global environment.