PRODUCT CATALOGUE Volume 4

Similar documents
Catalogue. Index INDUSTRIAL CABLE

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

FLEX-O-POWER FLEXIBLE WELDING

P High Voltage Catalogue Cables Australia Powering your Project

FR-3S Fire Resistant Cables

The cables you need when you need them

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

CONTROL CABLES CABLES FZE.

Power & Control Cable IEC

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

Any inquiries, please feel free to contact or Caledonian

POLYCAB WIRES PVT. LTD.

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

Power & Control Cables. U o. /U 0.6/1 kv - IEC

Power & Control Cable IEC

Technical Data Sheet Shielded (CY) PVC Control Cable

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

POLYCAB WIRES PVT. LTD.

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

CRANE, CONVEYOR, LIFT & REELING CABLES

POLYCAB WIRES PVT. LTD.

Technical Data Sheet Shielded (CY) PVC Control Cable

Telephone Cables Fire Warning Cables

Power & Control Cable IEC

600/1000V, PVC Insulated Cables according to IEC

POLYCAB WIRES PVT. LTD.

Power & Control Cables

Technical Data Sheet Unshielded (YY) PVC Control Cable

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

600/1000V, XLPE Insulated Cables according to IEC

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx

PRODUCT INFORMATION ÖLFLEX HEAT 125 C MC. Info Improved characteristics in the event of a fire GL - Germanischer Lloyd approved

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

PRODUCT INFORMATION H07V-K


Technical Data Sheet Shielded (CY) PVC Control Cable

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

POLYCAB WIRES PVT. LTD.

flame Retardant overall screened Instrumentation cables (Multicore)

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

LOW VOLTAGE c a b l e s

WIRES & WIRING CABLES

Airfield Ground Lighting

ELECTRICAL ITEMS Cables : Specification: XLPE Insulated Power Cable All Cables Cables PVC Insulated Cables Fire Resistant Cables Aluminium Cables

PVC INSULATED HEAVY DUTY CABLES

Quintas & Quintas Group

POLYCAB WIRES PVT. LTD.

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

Your Partner in Safe Power Solutions. About RESCAB

AN ISO 9001 : 2008 COMPANY

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Technical Data Sheet Unshielded (YY) PVC Control Cable

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

ÖLFLEX CLASSIC 110 CY

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

Data sheet chainflex CF240

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

BS6724 SWA/LSZH Cable IEC /1000V

CAAI-S 0,6/1 kv with Public Lighting

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

Data sheet chainflex CF6

VDE tested single cores according to EN (H05Z-K & H07Z-K) for more demanding requirements

N2XY IEC XLPE PVC 0.6/1kV Cable

THERMOCOUPLE AND RESISTANCE THERMOMETER CABLES

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

LSZH Fire Resistant Cables

Chemical resistance Accidental

Data sheet chainflex CF8821

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

o o blue-brown Fire Performance BS EN BS EN

Data sheet chainflex CF10

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

TRATOS OIL&GAS NEK606

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

Building & Infrastructure Cables DELIVERING ENERGY

BS 6724 Armoured Power Cables, 600/1000V

Data sheet chainflex CF140.UL

ÖLFLEX CLASSIC 115 CY

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

CO P P E R C A B LES A N D C O N N E C TO R S (P TY)

Data sheet chainflex CF210.UL

Wires that don t catch fire

Caledonian Fire Resistant Optic Fiber Cables

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

CABLES FOR AUTOMOTIVE MARKET Sensor and multimedia cables. Catalogue

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

Electronic Cable C O N N E C T I N G T E C H N O LO G Y W I T H P E R F O R M A N C E & P R E C I S I O N

www. h itech controls.com (800) I (303) Click or Call for a Quotel Photo: HELUKABEL Robotic Cables C HELUKABEL

PRODUCT INFORMATION. UNITRONIC LiYCY. Benefits Overall shield minimises electrical interference Versatile application possibilities

Transcription:

PRODUCT CATALOGUE Volume 4 Tel: +27(11) 864 1606 Main Fax: +27(11) 864 8294 E-mail: yasmin@soew.co.za Admin Fax: +27(11) 908 6439 Website: www.soew.co.za Agent - Durban Congella Cables cc 21 Canada Road Congella South Africa Tel: +27(31) 304 1417 Fax: +27(31) 304 1418 Agent - Cape Town South Atlantic Cables 25 Jenkinson Street Parow East South Africa Tel: +27(21) 930 6560 Fax: +27(21) 930 6536 We are committed to the highest quality and service.

COMPANY PROFILE PRODUCT GUIDE INTRODUCTION South Ocean Electric Wire Company (Pty) Ltd (SOEW) was established in 1989 and is a subsidiary of the JSE listed company, South Ocean Holdings Ltd. SOEW operates an electrical cable manufacturing plant in Alrode, since relocating from King Williams Town in December 2001. A full range of low voltage electrical cables are manufactured, from typical household wiring to industrial steel wire armoured cables. These are sold to electrical wholesalers and distributors who supply the building, construction, mining and retail industries. Manufacturing processes utilise practices which minimize any potential harmful impact on the environment. Bare Copper Earth Wire General Purpose House Wire Flat Twin and Earth Surface Wiring SOEW is a medium sized manufacturer of electrical cables with its main market in the general-purpose market, focusing on the wholesale sector. In 2008, the company initiated exports into new markets in Africa and this growth has been steady. SOEW endeavours to maintain excellent customer relationships, meeting their short and long term requirements, which is supported by excellent service and competitive pricing. The products are delivered to customers by SOEW s fleet of trucks and delivery vehicles. Twin Illumination Cable Cabtyre Single Core Flex Solid Panel Wire Quality products are supplied to customers and our products comply with standards laid down by the South African Bureau of Standards. The company was certified compliant with ISO 9001:2008 Management Standard in July 2009. The plant has quality control facilities and a testing laboratory to ensure that SOEW products perform optimally. The quality of all products are tested by the quality department team in its newly upgraded laboratory to ensure that SOEW products comply to the highest standards and perform optimally. Flex Power Ripcord Mainscord Submersible Pump Cable SOEW employs approximately 259 people who represent the full complement of personnel necessary to sustain the growth of our operation and includes electrical, engineering, administration, marketing and semi-skilled personnel. The company consistently works to improve the skill levels of staff, encouraging growth and development. The company emphasises on-the-job training and provides Adult Basic Education and Training to staff members. The company values the Health and Safety of its employees, creating a safe environment to operate in. Nitrile Trailing Cable PVC Nitrile Welding Cable Copper Flame Retardent (FR) Armoured Cable 600/1000V Copper Low Halogen (LHC) Armoured Cable 600/1000V MISSION STATEMENT To Offer Excellent and Reputable Service to our Shareholders, Customers, Suppliers and Staff. To be the Lowest Cost Producer with Products of the Highest Quality. To Remain an Entrepreneurial Company, and Create an Environment that Develops all of our Employees to Attain their True Potential. Copper Flame Retardent (ECC FR) Armoured Cable 600/1000V Copper Single Core XLPE PVC Cable Copper Single Core XLPE AWA PVC Cable Copper Flame Retardent Armoured Cable (FR) 1.9/3.3KV Aerial CNE Cable Aerial SNE Cable Aluminium Conductor Steel Reinforced (ACSR) Aerial Bundle Conductor (ABC) Aluminium Flame Retardent (FR) Armoured Cable 600/1000V Aluminium Low Halogen (LHC) Armoured Cable 600/1000V Aluminium ECC (FR) Armoured Cable 600/1000V Single Core Aluminium XLPE PVC Cable Aluminium Flame Retardent (FR) Armoured Cable 1.9/3.3KV Aluminium Low Halogen (LHC) Armoured Cable 1.9/3.3KV

INDEX 1 Bare Copper Earth Wire Page 2 General Purpose House Wire Page 3 Flat Twin and Earth Page 4 Surface Wiring Page 5 Twin Illumination Cable Page 6 Cabtyre Page 7 Single Core Flex Page 8 Solid Panel Wire Page 9 Flex Power Page 10 Ripcord Page 11 Mainscord Page 12 Submersible Pump Cable Page 13 Nitrile Trailing Cable Page 14 PVC Nitrile Welding Cable Page 15 Copper Flame Retardent (FR) Armoured Cable 600/1000V Page 16 Copper Low Halogen (LHC) Armoured Cable 600/1000V Page 17 Copper Flame Retardent (ECC FR) Armoured Cable 600/1000V Page 18 Copper Single Core XLPE PVC Cable Page 19 Copper Single Core XLPE AWA PVC Cable Page 20 Copper Flame Retardent (FR) Armoured Cable 1.9/3.3KV Page 21 Aerial Service Connection Cable (CNE) Page 22 Aerial Service Connection Cable (SNE) Page 23 Aluminium Conductor Steel Reinforced (ACSR) Page 24 Aerial Bundle Conductor (ABC) Page 25 Aluminium Flame Retardent (FR) Armoured Cable 600/1000V Page 26 Aluminium Low Halogen (LHC) Armoured Cable 600/1000V Page 27 Aluminium ECC (FR) Armoured Cable 600/1000V Page 28 Single Core Aluminium XLPE PVC Cable Page 29 Aluminium Flame Retardent (FR) Armoured Cable 1.9/3.3KV Page 30 Aluminium Low Halogen (LHC) Armoured Cable 1.9/3.3KV Page 31 Coaxial Cable Page 32 Extension Cords Page 33 Cable Accessories - Conduit Page 34 Quick Cable Selection Guide Page 35 SABS Certification Page 36

2 BARE COPPER EARTH WIRE Available in coils and wooden drums Single core stranded, annealed copper conductor SPECIFICATION: SANS 1411 APPROX. OVERALL NOMINAL STRANDING No. x CURRENT RATING (mm 2 ) (mm) (A) (MV/A/M) 1.5 7 x 0.53 1.6 20 29.00 2.5 7 x 0.66 2.0 27 18.00 4.0 7 x 0.85 2.6 37 11.00 6.0 7 x 1.04 3.1 47 7.30 10.0 7 x 1.35 4.1 65 4.40 16.0 7 x 1.67 5.0 87 2.80 25.0 7 x 2.14 6.4 114 1.75 35.0 19 x 1.53 7.7 141 1.25 50.0 19 x 1.78 8.9 182 0.95 70.0 19 x 2.14 10.7 234 0.66 95.0 19 x 2.52 12.6 284 0.50 120.0 37 x 2.03 14.2 330 0.41 150.0 37 x 2.25 15.8 381 0.34 185.0 37 x 2.52 17.6 436 0.29 240.0 61 x 2.25 20.2 515 0.25 300.0 61 x 2.52 22.7 594 0.22 400.0 61 x 2.80 26.0 694 0.20 500.0 61 x 3.20 29.2 792 0.185 630.0 91 x 2.97 32.7 904 0.175 Note 1: These ratings are for 2 cables single phase AC or DC clipped direct as per SANS 0142 table 6.2

GENERAL PURPOSE HOUSE WIRE 3 Shrink-wrapped coils Also available on spools or drums 100m 500m Plain annealed stranded copper conductors, insultated with a general purpose grade PVC For the wiring of Housing, Buildings, Control Panels, Appliances SPECIFICATION: SANS 1507-3 Voltage Rating: 600/1000V Temperature Range: -10⁰C to 70⁰C Sheath colours: Black, Blue, Brown, Green/Yellow, Grey, Orange, Pink, Purple, Red, White, Yellow NOMINAL STRANDING No. x APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 1.0 7 x 0.43 2.9 15 44.00 1.7 1.5 7 x 0.53 3.2 20 29.00 2.3 2.5 7 x 0.66 3.6 27 18.00 3.3 4.0 7 x 0.85 4.5 37 11.00 5.2 6.0 7 x 1.04 5.1 47 7.30 7.2 10.0 7 x 1.35 6.0 65 4.40 11.2 16.0 7 x 1.67 7.0 87 2.80 17.0 25.0 19 x 1.31 8.6 114 1.75 26.6 35.0 19 x 1.53 10.0 141 1.25 35.7 50.0 19 x 1.78 11.5 182 0.95 48.3 70.0 19 x 2.14 13.3 234 0.66 68.0 95.0 19 x 2.52 15.5 284 0.50 94.0 120.0 37 x 2.03 17.1 330 0.41 115.4 150.0 37 x 2.25 19.0 381 0.34 142.6 185.0 37 x 2.52 21.2 436 0.29 179.0 240.0 61 x 2.25 24.1 515 0.25 233.5 300.0 61 x 2.52 27.0 594 0.22 195.0 400.0 61 x 2.80 30.3 694 0.20 375.0 500.0 61 x 3.20 34.1 792 0.185 479.0 630.0 91 x 2.97 38.0 904 0.175 612.0 Note 1: These ratings are for 2 cables single phase AC or DC clipped direct as per SANS 0142 table 6.2

4 FLAT TWIN AND EARTH Shrink-wrapped coils Also available on wooden drums 100m 1000m Solid or stranded plain copper conductors, PVC insulated, laid up with bare copper earth wire, PVC sheathed overall For the wiring of Under-plaster wiring, Roof wiring, Under-floor wiring SPECIFICATION: SANS 1507-2 Voltage Rating: 300/500 V Temperature Range: -10 C to 70 C Sheath colours: Core colours: Black and white 2 core - black and red 3 core - blue, red and yellow CONDUCTOR TYPE APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (Main) (Earth) (mm) (A) (MV/A/M) (kg) 1 1/1.5 1/1.5 7.9 x 4.3 15 44.0 6.76 1.5 1/1.38 1/1.15 8.8 x 4.8 19 29.0 8.33 2.5 1/1.78 1/1.38 10.4 x 5.6 27 18.0 11.7 4 7/0.86 1/1.38 12.2 x 6.2 36 11.0 18.3 6 7/1.04 1/1.78 13.7 x 7.2 46 7.3 23.4 10 7/1.38 7/0.86 17.2 x 8.6 63 4.4 37.1 16 7/1.72 7/1.04 20.0 x 9.8 85 2.8 52.0 Note 1: These ratings are for 2 cables single phase AC or DC clipped direct as per SANS 0142 table 6.3 # Conductors of 4mm2 and over are stranded

SURFACE WIRING 5 Shrink-wrapped coils Also available on wooden drums 100m 1000m Plain copper conductors, PVC insulated, laid up with a tinned earth wire in contact with a longitudinal Aluminium foil tape, PVC sheathed overall For the wiring of Under-plaster wiring, Roof wiring, Under-floor wiring, Surface wiring SPECIFICATION: SANS 1507-2 Voltage Rating: 300/500V Temperature Range: -10 C to 70 C Sheath colours: Core colours: Black and white 2 core - Black and red 3 core - Blue, red and yellow 4 core - Black, blue, red and yellow CONDUCTOR TYPE APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) MAIN EARTH 2C 3C 4C 2C 3C & 4C 2C 3C & 4C 2C 3C 4C 1.5 1.5 1/1.15 8.1 7.6 8.8 19 17 29.0 25.0 10.2 12.1 14.1 2.5 2.5 1/1.38 9.4 8.8 10.3 27 24 18.0 15.0 14.4 16.5 19.6 4.0 4.0 1/1.38 11.1 10.4 12.2 36 32 11.0 9.5 18.6 23.5 28.1 6.0 6.0 1/1.78 12.3 11.5 13.5 46 41 7.3 6.4 27.5 31.7 41.4 10.0 10.0 7/0.86 14.4 63 4.4 35.6 Note 1: These ratings are for 2 cables single phase AC or DC clipped direct as per SANS 0142 table 6.3

6 TWIN ILLUMINATION CABLE Shrink-wrapped coils 100m Stranded plain copper conductors, PVC insulated laid flat with a PVC outer Sheath For the wiring of Outdoor lighting using quickfit lampholders SPECIFICATION: SANS 1507 Voltage Rating: 300/500 V Temperature Range: -10 C to 70 C Sheath colour: Black or white Core colours: 2 core - Black and red NOMINAL STRANDING No.x APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 2.5 7 x 0.67 5.6 x 10.2 25 15 11.5

CABTYRE 7 Shrink-wrapped coils Also available on wooden drums 100m 1000m Flexible plain copper conductors, PVC Insulated, PVC Sheathed overall For the wiring of Extension Cords, Kitchen Appliances, Power Tools SPECIFICATION: SANS 1574 Voltage Rating: Light Duty (LD) 300/300 V Normal Duty (ND) 300/500 V Temperature Range: -10⁰C to 70⁰C Sheath colour: Black, White, Grey, Red and Orange Core colours: 2 core - Brown and Blue 3 core - Blue, Brown and Green/Yellow 4 core - Black, Blue, Brown and Green/Yellow 5 core - Black, Blue, Brown, Green/Yellow and Violet 7 core - Black, Blue, Brown, Green/Yellow, Violet, Pink and Orange CONDUCTOR STRANDS No. x APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 2C 3C 4C 5C 7C 2C 3, 4, 5 & 7C 2C 3C 4C 5C 7C LIGHT DUTY 0.5 16 x 0.20 5.2 5.6 6.1 6.6 3 93 80 3.5 4.2 5.1 6.7-0.75 24 x 0.20 5.7 5.9 6.6 - - 6 62 54 4.9 5.6 6.70 - - HEAVY DUTY - - 0.75 24 x 0.20 6.1 6.5 7.0 7.9 9.3 6 62 54 5.8 6.8 8.0 9.9 12.2 1.0 30 x 0.20 6.7 7.11 7.76 8.6 10.9 10 46 40 6.7 7.6 9.7 11.6 14.8 1.5 30 x 0.25 7.8 8.50 9.50 10.1 13.2 16 32 27 8.9 10.6 13.4 16.2 20.6 2.5 50 x 0.25 9.5 10.4 11.3 12.2 14.1 20 19 16 13.4 16.0 20.1 24.2 31.5 4.0 56 x 0.30 10.3 11.7 12.9 14.1 25 12 10 17.6 22.2 27.5 33.9 - Note 1: Based on a max ambient temperature of 30 C and max conductor temperature of 70 C

8 SINGLE CORE FLEX Shrink-wrapped coils Also available on wooden drums 100m 1000m Plain annealed flexible copper conductor, insulated with a flexible grade PVC. For the wiring of Control Panels, Light fittings, Appliances SPECIFICATION: SANS 1574-3 Voltage Rating: 600/1000V Temperature Range: -10⁰C to 70⁰C Sheath colours: Black, blue, brown, green/yellow, grey, orange, pink, purple, red, white and yellow NOMINAL STRANDING No. x APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 0.5 15w x 0.20 2.48 3 93.00 0.99 0.75 22w x 0.20 2.68 6 62.00 1.07 1.0 29w x 0.20 2.86 10 44.00 1.53 1.5 28w x 0.25 3.12 16 29.00 2.00 2.5 46w x 0.25 3.54 27 18.00 2.94 4.0 52w x 0.30 4.48 37 11.00 4.72 6.0 84w x 0.30 5.20 47 7.30 7.30 10.0 140w x 0.30 6.12 65 4.40 11.34 16.0 200w x 0.30 9.50 87 2.80 22.0 25.0 312w x 0.30 12.50 114 1.75 30.0 35.0 440w x 0.30 12.90 141 1.25 40.0 Note 1: Based on a max ambient temperature of 30 C and max conductor temperature of 70 C

SOLID PANEL WIRE 9 Shrink-wrapped coils 100m High conductivity, solid copper conductor to Sans 1411 part 1. PVC insulated 105 C For the wiring of Ballasts, Fluorescent Lights SPECIFICATION: SANS 1507-2 Voltage Rating: 300/500V Temperature Range: Sheath Colours: -10⁰C to 70⁰C Black, blue, brown, green, grey, orange, pink, purple, red, white and yellow NOMINAL STANDING No. x APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 0.5 1 x 0.8 2.00 10 93 0.83 1.0 1 x 1.2 2.31 15 44 1.30 Note 1: Based on a max ambient temperature of 30 C and max conductor temperature of 70 C

10 FLEX POWER Shrink-wrapped coils Also available on wooden drums 100m 500m Plain annealed flexible copper conductor, flexible PVC bedded, with a Nitrile PVC sheath For the wiring of Control panels and power installations where a flexible conductor is required. SPECIFICATION: SANS 1574-3 Voltage Rating: 600/1000V Temperature Range: -10⁰C to 70⁰C Sheath colours: Black, red, green/yellow, blue (Other colours available on request) NOMINAL STRANDING No. x APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 16.0 240 x 0.3 10.3 80 2.420 21.2 25.0 329w x 0.3 11.9 114 1.560 29.4 35.0 455w x 0.3 13.6 141 1.108 38.7 50.0 670w x 0.3 15.7 182 0.772 55.7 70.0 904w x 0.3 17.0 234 0.544 73.6 95.0 1190w x 0.3 19.1 284 0.412 95.3 120.0 1530w x 0.3 22.9 330 0.161 131.0 150.0 1917w x 0.3 25.8 376 0.258 155.3 Note 1: Based on a max ambient temperature of 30 C and a max conductor temperature of 70 C

RIPCORD 11 Shrink-wrapped coils 100m Flexible plain copper conductors, PVC insulated For the wiring of Audio Equipment, Intercoms, Alarm Systems SPECIFICATION: SANS 1574 Voltage Rating: 80V Temperature Range: -10⁰C to 70⁰C Sheath Colours: Black, white, brown, transparent (Other colours available on request) NOMINAL STANDING No. x APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 0.5 16 x 0.20 2.4 x 4.8 5 93 2.2 0.75 24 x 0.20 2.6 x 5.2 6 62 2.8 Note 1: Based on a max ambient temperature of 30 C and a max conductor temperature of 70 C

12 MAINSCORD Shrink-wrapped coils 100m Flexible plain copper conductors, PVC insulated laid flat with a PVC outer sheath For the wiring of Lamps, Light Household Appliances, Visual Equipment SPECIFICATION: SANS 1574 Voltage Rating: 300/300V Temperature Range: -10⁰C to 70⁰C Sheath Colours: Black, White Core Colours: 2 core - Brown and Blue NOMINAL STRANDING No. x APPROX. OVERALL CURRENT RATING CONDUCTOR RESISTANCE AT 200C MAXIMUM APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (Ω/KM) (MV/A/M) (kg) 0.5 0.20 x 16 3.1 x 5.0 3 39 93 4.0 0.75 0.20 x 24 3.8 x 6.1 6 26 62 4.2 Note 1: Based on a max ambient temperature of 30 C and a max conductor temperature of 70 C

SUBMERSIBLE PUMP CABLE 13 Shrink-wrapped coils Also available on wooden drums 100m 500m Flexible plain copper conductors, PVC insulated, PVC Nitrile overall Submersible Pumps, Boreholes, Farms SPECIFICATION: SANS 1574 Voltage Rating: 600/1000 V Temperature Range: -10⁰C to 70⁰C Sheath Colours: 3 core - Royal Blue 4 core - Green Core Colours: 3 core - Red, Yellow, Blue 4 core - Red, Yellow, Blue, Black NOMINAL STANDING No. x APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 1.5 X 3 28w x 0.25 9.0 15 26.00 12.0 2.5 X 3 46w x 0.25 10.0 20 16.00 17.0 4.0 X 3 52w x 0.30 11.9 30 10.00 23.0 6.0 X 3 84w x 0.30 14.5 35 6.40 42.0 10.0 X 3 140w x 0.30 17.0 50 3.80 52.0 16.0 X 3 210.w x 0.30 19.0 65 2.40 70.0 4 Core (mm 2 ) (mm) (A) (MV/A/M) (kg) 1.5 X 4 28w x 0.25 10.5 15 26.00 20.0 2.5 X 4 46w x 0.25 11.0 20 16.00 25.0 4.0 X 4 52w x 0.30 13.5 30 10.00 32.0 6.0 X 4 84w x 0.30 16.0 35 6.40 48.0 10.0 X 4 140w x 0.30 18.3 50 3.80 68.0 16.0 X 4 210.w x 0.30 21.0 65 2.40 90.0 Note 1: Based on a max ambient temperature 30⁰C and conductor temperature of 70⁰C

14 NITRILE TRAILING CABLE Shrink-wrapped coils Also available on wooden drums 100m 500m Flexible plain copper conductors, PVC insulated, PVC bedded, PVC Nitrile sheathed overall For the wiring of Portable and mobile machinery SPECIFICATION: SANS 1574 Voltage Rating: 600/1000V Temperature Range: -10⁰C to 70⁰C Sheath Colour: Orange Core Colours: 4 core - Red, Yellow, Blue and Black NOMINAL STRANDING No. x APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 1.5 x 4 30 x 0.25 12.0 16 27.00 22.0 2.5 x 4 50 x 0.25 13.5 25 16.00 27.0 4.0 x 4 56 x 0.30 15.5 32 10.00 38.0 6.0 x 4 84 x 0.30 18.0 37 6.50 52.0 10.0 x 4 140 x 0.30 20.0 50 3.80 72.0 16.0 x 4 224 x 0.30 24.0 65 2.40 104.0 25.0 x 4 376 x 0.30 28.0 89 1.50 149.0 Note 1: Based on a max ambient temperature of 30 C and a max conductor temperature of 70 C

PVC NITRILE WELDING CABLE 15 Shrink-wrapped coils Also available on wooden drums 100m 500m A light duty welding cable comprising of a flexible conductor insulated with a Nitrile/PVC (Synthetic Rubber) compound A welding cable for use in an environment where there is minimal abrasion or oil. SPECIFICATION: SANS 1576/AS A GUIDE Voltage Rating: 100/100 V COLOUR APPROX. OVERALL MAXIMUM CONDUCTOR RESISTANCE APPROX. CABLE WEIGHT MASS PER 100M COIL 100% (60min/hr) CURRENT RATING AT A DUTY CYCLE OF: 85% (50min/hr) 60% (36min/hr) 30% (18min/hr) 20% (12min/hr) (mm 2 ) (mm) (Ω/km) (kg) (A) 16.0 Green 10.3 1.19 21.2 110 120 140 200 245 25.0 Blue 11.9 0.78 29.4 140 150 180 255 315 35.0 Grey 13.6 0.55 38.7 185 200 240 340 415 50.0 Red 15.7 0.39 55.7 230 250 295 420 515 70.0 Brown 17 0.28 73.6 290 315 375 530 650 95.0 Yellow 19.1 0.21 95.3 350 380 450 640 785 120.0 Black 22.9 0.16 131.0 405 440 525 740 905 Note 1: Based on a max ambient temperature 30⁰C and conductor temperature of 70⁰C

16 COPPER FLAME RETARDENT (FR) ARMOURED CABLE 600/1000V Wooden drums 300m & 500m Plain Annealed copper conductors, PVC insulated, PVC,Bedded, Galvanised Steel Wire Armour, PVC (FR) Sheath These cables may be used for main power distribution in general industries,houses and commercail buildings. These cables are suitable for direct burial installations as well as in air or ducts. The flame retardency in the PVC of the cable prevents the spread of fire SPECIFICATION: SANS 1507-3 Voltage Rating: 600/1000V Sheath Colours: Core Colours: Black with Red stripe 2 core -Black and Red 3 core -Red, Yellow and Blue 4 core -Red, Yellow, Blue and Black 7 core -Red, Yelllow, Blue, Black, Voilet, Brown and Orange APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 2C 3C 4C 7C 2C 3, 4, & 7C 2C 3C 4C 7C 1.5 13.9 14.4 17.2 17.2 21 18 29 38 44 48 61 2.5 14.6 15.2 16.2 18.3 28 25 18 44 49 56 74 4 16.7 17.4 18.9 21.2 38 33 11 56 64 73 99 6 17.8 18.8 20.2 23.2 49 42 7.3 67 77 88 119 10 19.9 20.8 22.5-67 58 4.4 84 96 113-16 17.8 20.1 22.2-89 77 2.8 76 103 128-25 - 26.5 28.4-118 102 1.75-164 192-35 - 27.9 31.2-145 125 1.25-220 237-50 - 31.5 36.5-175 151 0.93-287 320-70 - 35.5 40.1-222 192 0.63-361 450-95 - 40 44.7-269 231 0.46-490 596-120 - 42.2 47.4-310 267 0.36-572 710-150 - 46 52.7-356 306 0.29-690 925-185 - 51.2 57.5-405 348 0.23-869 1103-240 - 57.2 64.2-476 409 0.18-1076 1372-300 - 62.2 70.2-547 469 0.145-1295 1654 - Note 1: These ratings are per SANS 0142 table 6.4

COPPER LOW HALOGEN (LHC) ARMOURED CABLE 600/1000V 17 Wooden drums 300m & 500m Plain Annealed copper conductors, PVC insulated, PVC(LH), Bedded, Galvanised Steel Armour, PVC (LH) Sheath These cables may be used for main power distribution in general industries, houses and commercial buildings. These cables are suitable for direct burial installations as well as in air or ducts. The PVC in LHC armoured cable is specially formulated to reduce corrosive halogen gasses which are produced by burning PVC, so are suitable for use in closed areas such as mines and offices. SPECIFICATION: SAN 1507-3 Voltage Rating: 600/1000V Sheath Colours: Core Colours: Black with Blue stripe 2 core - Black and Red 3 core - Red, Yellow and Blue 4 core - Red, Yellow, Blue and Black 7 core - Red, Yellow, Blue, Black, Violet, Brown and Orange APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) 2C 3C 4C 7C 2C 3, 4, & 7C 2C 3C 4C 7C 1.5 13.9 14.4 15.2 17.2 21 18 29 39 45 49 63 2.5 14.6 15.2 16.2 18.3 28 25 18 45 50 58 76 4 16.7 17.4 18.9 21.6 38 33 11 58 66 75 102 6 17.8 18.8 20.2 23.2 49 42 7.3 69 79 91 123 10 19.9 20.8 22.5-67 58 4.4 87 99 116-16 17.8 20.1 22.2-89 77 2.8 78 106 132-25 - 26.5 28.4-118 102 1.75-169 198-35 - 27.9 31.2-145 125 1.25-227 244-50 - 31.5 36.5-175 151 0.93-296 330-70 - 35.5 40.1-222 192 0.63-372 464-95 - 40 44.7-269 231 0.46-505 614-120 - 42.2 47.4-310 267 0.36-589 731-150 - 46 52.7-356 306 0.29-711 953-185 - 51.2 57.5-405 348 0.23-895 1136-240 - 57.2 64.2-476 409 0.18-1108 1413-300 - 62.2 70.2-547 469 0.145-1334 1703 - Note 1: These ratings are per SANS 0142 table 6.4

18 COPPER FLAME RETARDENT (ECC FR) ARMOURED CABLE 600/1000V Wooden drums 300m & 500m Plain Annealed copper conductors, PVC insulated, PVC Bedded Galvanised Steel Wire Armour with Earth continuity Conductors in the armour, PVC Sheath These cables may be used for main power distribution in general industries, houses and commercial buildings where the concentric earth eliminates the need for a supplementary earth continuity conductor SPECIFICATION: SANS 1507-3 Voltage Rating: 600/1000V Sheath Colours: Core Colours: Black with Brown stripe 2 core - Black and Red 3 core- Red, Yellow and Blue 4 core -Red, Yellow, Blue and Black 7 core -Red, Yellow, Blue, Black, Voilet, Brown and Orange SIZE OF ECC APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm 2 ) (mm) (A) (MV/A/M) (kg) 2C 3C 4C 7C 2C 3, 4, & 7C 2C 3C 4C 7C 1.5 1 13.9 14.4 15.2 17.2 21 18 29 39 45 49 63 2.5 15 14.6 15.2 16.2 18.3 28 25 18 45 50 58 76 4 2.5 16.7 17.4 18.9 21.6 38 33 11 58 66 75 102 6 4 17.8 18.8 20.2 23.2 49 42 7.3 69 79 91 123 10 6 19.9 20.8 22.5-67 58 4.4 87 99 116-16 10 17.8 20.1 22.2-89 77 2.8 78 106 132-25 16-26.5 28.4-118 102 1.75-169 198-35 16-27.9 31.2-145 125 1.25-227 244-50 25-31.5 36.5-175 151 0.93-296 330-70 35-35.5 40.1-222 192 0.63-372 464-95 50-40 44.7-269 231 0.46-505 614-120 70-42.2 47.4-310 267 0.36-589 731-150 70-46 52.7-356 306 0.29-711 953-185 95-51.2 57.5-405 348 0.23-895 1136-240 120-57.2 64.2-476 409 0.18-1108 1413-300 150-62.2 70.2-547 469 0.145-1334 1704 - Note 1: These ratings are per SANS 0142 table 6.4

COPPER SINGLE CORE XLPE PVC CABLE 19 Wooden drums 300m & 500m Plain annealed stranded copper conductors, XLPE insulated unarmoured, PVC Sheath Power distribution Distribution Panels and Transformers SPECIFICATION: SANS 1507-3 Voltage Rating: 600/1000V Temperature Range: -10⁰C to 70⁰C Sheath colours: Black (Other colours available on request) NOMINAL STRANDING No. x APPROX. OVERALL NOMINAL S CURRENT RATING APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (A) (MV/A/M) (kg) Insulation Sheath 120.0 37 x 2.03 17.1 20.2 330 0.410 129 150.0 37 x 2.25 19.0 22.2 381 0.340 158 185.0 37 x 2.52 21.2 24.7 436 0.290 197 240.0 61 x 2.25 24.1 27.8 515 0.250 256 300.0 61 x 2.52 26.9 30.9 594 0.220 322 400.0 61 x 2.80 30.3 34.4 694 0.200 407 500.0 61 x 3.20 34.0 38.3 792 0.185 516 630.0 91 x 2.97 37.9 42.5 904 0.175 655 Note 1: These ratings are for 2 cables single phase AC or DC clipped direct as per SANS 0142 table 6.2

20 COPPER SINGLE CORE XLPE AWA PVC CABLE Wooden drums 300m & 500m Plain annealed stranded copper conductors, XLPE insulated AWA, PVC Sheath Power distribution Distribution Panels and Transformers SPECIFICATION: SANS 1507-3 Voltage Rating: 600/1000V Temperature Range: -10⁰C to 70⁰C Sheath colours: Black (Other colours available on request) NOMINAL STRANDING No. x DIAM- ETER APPROX. CURRENT RATING VOLT DROP APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) Ground (A) Insulation AWA Sheath Duct (A) Air (A) (MV/A/M) (kg) 120.0 37 x 2.03 17.1 1.6 25.66 301 269 314 0.41 178 150.0 37 x 2.25 19.0 1.6 28.00 336 299 357 0.34 210 185.0 37 x 2.52 21.2 1.6 30.3 370 329 401 0.29 254 240.0 61 x 2.25 24.1 1.6 33.3 410 363 481 0.25 311 300.0 61 x 2.52 26.9 2.0 37.7 476 420 546 0.22 412 400.0 61 x 2.80 30.3 2.0 42.3 529 465 622 0.20 513 500.0 61 x 3.20 34.0 2.0 46.00 581 509 695 0.18 620 630.0 91 x 2.97 37.9 2.5 50.9 623 541 779 0.17 821 Note 1: These ratings are for 2 cables single phase AC or DC clipped direct as per SANS 0142 table 6.2

COPPER FLAME RETARDENT (FR) ARMOURED CABLE 1.9/3.3KV 21 Wooden drums 300m & 500m Shaped stranded copper conductors, XLPE insulated, PVC Bedded, Galvanised steel wire Armour, PVC (FR) Sheathed These cables may be used for main power distribution in general industries, houses and commercial buildings.these cables are suitable for direct burial installations as well as in air or ducts. The flame retardency in the PVC of the cable prevents the spread of fire SPECIFICATION: SANS 1507-3 Voltage Rating: 1900/3300V Sheath Colour: Black with Red stripe Core Colours: 3 core - Red, Yellow and Blue APPROX. OVERALL CURRENT RATING IMPEDANCE VOLT DROP APPROX. CABLE WEIGHT MASS PER 100M COIL (mm 2 ) (mm) (Ω/km) (MV/A/M) (kg) Overall Ground (A) Ducts (A) 10 26 70 58 62 2.19 4.4 142 16 29 91 75 83 1.38 2.8 196 25.0 32 119 96 110 0.727 1.257 224 35.0 34 143 116 135 0.524 0.907 237 50.0 37 169 138 163 0.387 0.67 274 70.0 39 210 171 207 0.268 0.464 382 95.0 42 251 205 251 0.193 0.334 507 120.0 43 285 234 290 0.153 0.265 593 150.0 45 320 263 332 0.124 0.215 717 185.0 46 361 298 378 0.153 0.265 809 240.0 55 416 344 445 0.104 0.18 1108 300.0 59 465 385 510 0.078 0.14 1564 Note 1: These ratings are per SANS 0142 table 6.4 Air (A)

22 AERIAL SERVICE CONNECTION CABLE (CNE) Wooden drums 500m Stranded hard drawn copper phase conductor, XLPE insulated with bare/neutral earth conductors. Polyethylene sheathed house service cable. Nylon ripcord laid under sheath. Aerial CNE Cable is used for house connections. This cable can only be used for single phase supply. Cable is made to be suspended in the air. Aerial CNE Cable is also suitable for underground general use. Split concentric cable suitable for power distribution as an underground or overhead cable. SPECIFICATIONS: SANS 1507/6 Voltage rating: 600/1000V Conductor type: Bare neutral and earth conductors Cable Size (mm 2 ) 10 16 Phase Conductor Resistance (Ohm/Km) DC @ 20 C 1.89 1.19 Phase Conductor Impedance (Ohm/Km) 2.34 1.47 Phase Conductor Strand size (mm) & No. 1.35 x 7 1.74 x 7 Phase Conductor Insulation Thickness (mm) 0.7 0.7 Phase conductor OD (mm) 5.45 6.41 Neutral Size (mm 2 ) 10 16 Neutral Conductor Strand size (mm) & No. 1.33 x 7 1.67 x 7 Earth size (mm 2 ) 7.5 11 Earth Conductor Strand Size (mm) & No. 1.78 x 3 2.2 x 3 Communication Cores - Solid - OD(mm) & No. 0.8 x 2 0.8 x 2 Current Rating (A) 67 89 (In Air 30 C ambient - max Conductor Temperature 90 C) Nominal Sheath Thickness (mm) 1.4 1.6 Approximate Cable OD (mm) 12 14 Approximate Cable Mass (Kg/Km) 319 488

AERIAL SERVICE CONNECTION CABLE (SNE) 23 Wooden drums 500m Stranded hard drawn copper phase conductor, XLPE insulated, Polyethylene insulated neutral with bare earth conductors. Polyethylene sheathed cable. Nylon ripcord laid under sheath. Aerial SNE Cable is used for house connections. This cable can only be used for single phase supply. Cable is made to be suspended in the air. Aerial SNE Cable is also suitable for underground general use. Split concentric cable suitable for power distribution as an underground or overhead cable. SPECIFICATIONS: SANS 1507/6 Voltage rating: 600/1000V Conductor type: Insulated neutral and bare earth conductors Cable Size (mm 2 ) 10 16 Phase Conductor Resistance (Ohm/Km) DC @ 20 C 1.89 1.19 Phase Conductor Impedance (Ohm/Km) 2.34 1.47 Phase Conductor Strand size (mm) & No. 1.35 x 7 1.74 x 7 Phase Conductor Insulation Thickness (mm) 0.7 0.7 Phase conductor OD (mm) 5.45 6.41 Neutral Size (mm 2 ) 10 16 Neutral Conductor Strand size (mm) & No. 1.33 x 7 1.67 x 7 Earth size (mm 2 ) 7.5 11 Earth Conductor Strand Size (mm) & No. 1.78 x 3 2.2 x 3 Communication Cores - Solid - OD(mm) & No. 0.8 x 2 0.8 x 2 Current Rating (A) 67 89 (In Air 30 C ambient - max Conductor Temperature 90 C) Nominal Sheath Thickness (mm) 1.4 1.6 Approximate Cable OD (mm) 12 14 Approximate Cable Mass (Kg/Km) 319 488

24 ALUMINIUM CONDUCTOR STEEL REINFORCED (ACSR) Wooden drums Plain Hard drawn Aluminium strands laid up around a Galvanised Steel Wire centre strand Conductor for overhead transmission lines SPECIFICATION: IEC 61089 MASS (KG/KM) CODE NAME EQUIVALENT COPPER AREA STRANDING OR WIRE OVERALL TENSILE STRENGTH DC RESISTANCE @ 200C CURRENT RATING STD. DRUM LENGTH (mm 2 ) (mm) (mm) Aluminium Steel Total (N) (Ω/km) (A) (M) Mole 6.45 6/1/1.50 4.50 29.10 13.89 42.99 4780 2.7062 87 3000 Squirrel 12.9 6/1/2.11 6.33 57.70 27.38 85.08 8020 1.3677 130 3000 Gopher 16.3 6/1/2.36 7.08 72.20 34.27 106.47 9610 1.0933 150 3000 Fox 22.58 6/1/2.79 8.37 100.55 47.87 148.42 13100 0.7822 190 3000 Ferrett 25.81 6/1/3.00 9.00 116.77 55.50 172.27 15200 0.6766 210 1500 Rabbit 32.26 6/1/3.35 10.05 145.57 69.20 214.77 18500 0.5426 240 1500 Mink 38.71 6/1/3.66 10.98 173.80 82.39 256.19 21900 0.4546 260 1500 Beaver 45.16 6/1/3.99 11.97 206.56 98.12 304.67 25900 0.3825 290 1500 Raccoon 48.39 6/1/4.09 12.27 217.04 103.15 320.19 27200 0.364 300 1500 Hare 64.52 6/1/4.72 14.16 289.00 137.02 426.02 36000 0.2733 360 1500

AERIAL BUNDLE CONDUCTOR (ABC) 25 Wooden drums 300m & 500m Two systems are available, namely: SELF-SUPPORTING SYSTEM: Consists of four cores of hard drawn stranded compacted aluminium conductors of the same cross-sectional area insulated with Carbon loaded XLPE for UV protection SUPPORTING CORE SYSTEM: Consists of three phase cores of hard drawn stranded compacted aluminium conductors of the same cross-sectional area insulated with Carbon loaded XLPE and laid up around a bare aluminium alloy supporting core APPLICATIONS: ABC Cable is used in place of bare conductor overhead distribution systems. It provides a higher level of safety and reliability and economy with reduced maintenance and operative costs and reduced risks of vandalism and theft. It is ideal for difficult terrains and urban areas and is a flexible system that is easier to reroute than the conventional overhead line methods (SELF-SUPPORTING SYSTEM) DESCRIPTION NOMINAL CONDUCTOR NOMINAL CORE CONDUCTOR RESISTANCE @200C CONDUCTOR RESISTANCE @800C CURRENT RATING SHORT CIRCUIT RATING NOMINAL BUNDLE MAXIMUM DESIGN LOAD APPROX. BUNDLE WEIGHT STANDARD (mm) (mm) (Ω/km) (Ω/km) (A) (ka) (mm) (kn) (kg/km) (M) 35 x 4 7.2 10.4 0.868 1.078 144 3.2 25.1 7 566.38 500/1000 50 x 4 8.37 11.57 0.641 0.796 183 4.6 27.9 9 733.08 500/1000 70 x 4 9.95 13.55 0.443 0.550 228 6.4 32.7 14 979.99 500/1000 (SUPPORTING CORE SYSTEM) DESCRIPTION NOMINAL CONDUCTOR NOMINAL CORE CONDUCTOR RESISTANCE @200C CONDUCTOR RESISTANCE @800C CURRENT RATING SHORT CIRCUIT RATING NOMINAL BUNDLE MAXIMUM DESIGN LOAD APPROX. BUNDLE WEIGHT STANDARD (mm) (mm) (Ω/km) (Ω/km) (A) (ka) (mm) (kn) (kg/km) (M) 35 x 3 + 54.6 7.2 10.4 0.868 1.078 144 3.2 25.1 6 574.86 500/1000 50 x 3 + 54.6 8.37 11.57 0.641 0.796 183 4.6 27.9 6 701.07 500/1000 70 x 3 + 54.6 9.95 13.55 0.443 0.550 228 6.4 32.7 6 878.21 500/1000

26 ALUMINIUM FLAME RETARDENT (FR) ARMOURED CABLE 600/1000V Wooden drums 300m & 500m Plain Hard drawn Aluminium conductors, XLPE insulated, PVC Bedded, Galvanised Steel Wire Armour, PVC (FR) Sheath These cables may be used for main power distribution in general industries,houses and commercail buildings. These cables are suitable for direct burial installations as well as in air or ducts. The flame retardency in the PVC of the cable prevents the spread of fire SPECIFICATION: SANS 1507/4 Voltage Rating: 600/1000V Sheath Colours: Core Colours: Black with Red stripe 2 core -Black and Red 3 core -Red, Yellow and Blue 4 core -Red, Yellow, Blue and Black 7 core -Red, Yelllow, Blue, Black, Voilet, Brown and Orange APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT (mm 2 ) (mm) (A) (MV/A/M) (kg/km) 16 20.2 61 3.9 895 25 24.9 80 2.5 1197 35 27.3 99 1.8 1356 50 31.3 119 1.35 1845 70 37.3 151 0.92 2630 95 40.1 186 0.68 3181 120 44.8 216 0.55 3811 150 47.2 250 0.44 4745 185 53.5 287 0.37 5563 240 59.3 342 0.3 6861 Note 1: These ratings are per SANS 0142 table 6.7(a) Information shown is for 4 core. -2, 3 and 7 core information available on request

ALUMINIUM LOW HALOGEN (LHC) ARMOURED CABLE 600/1000V 27 Wooden drums 300m & 500m Plain Hard drawn Aluminium conductors, XLPE insulated, PVC (LH) Bedded, Galvanised Steel Wire Armour, PVC (LH) Sheath These cables may be used for main power distribution in general industries, houses and commercial buildings. These cables are suitable for direct burial installations as well as in air or ducts. The PVC in LHC armoured cable is specially formulated to reduce corrosive halogen gasses which are produced by burning PVC, so are suitable for use in closed areas such as mines and offices. SPECIFICATION: SAN 1507/4 Voltage Rating: 600/1000V Sheath Colours: Core Colours: Black with Blue stripe 2 core - Black and Red 3 core - Red, Yellow and Blue 4 core - Red, Yellow, Blue and Black 7 core - Red, Yellow, Blue, Black, Violet, Brown and Orange APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT (mm 2 ) (mm) (A) (MV/A/M) (kg/km) 16 20.2 61 3.9 895 25 24.9 80 2.5 1197 35 27.3 99 1.8 1356 50 31.3 119 1.35 1845 70 37.3 151 0.92 2630 95 40.1 186 0.68 3181 120 44.8 216 0.55 3811 150 47.2 250 0.44 4745 185 53.5 287 0.37 5563 240 59.3 342 0.3 6861 Note 1: These ratings are per SANS 0142 table 6.7(a) Information shown is for 4 core. -2, 3 and 7 core information available on request

28 ALUMINIUM ECC (FR) ARMOURED CABLE 600/1000V Wooden drums 300m & 500m Plain Hard drawn Aluminium conductors, XLPE insulated, PVC Bedded, Galvanised Steel Wire Armour with Earth Continuity Conductors in the Armour, PVC Sheath These cables may be used for main power distribution in general industries, houses and commercial buildings where the concentric earth eliminates the need for a supplementary earth continuity conductor SPECIFICATION: SANS 1507/4 Voltage Rating: 600/1000V Sheath Colours: Core Colours: Black with Brown stripe 2 core - Black and Red 3 core- Red, Yellow and Blue 4 core -Red, Yellow, Blue and Black 7 core -Red, Yellow, Blue, Black, Voilet, Brown and Orange APPROX. OVERALL CURRENT RATING APPROX. CABLE WEIGHT (mm 2 ) (mm) (A) (MV/A/M) (kg/km) 16 20.2 61 3.9 895 25 24.9 80 2.5 1197 35 27.3 99 1.8 1356 50 31.3 119 1.35 1845 70 37.3 151 0.92 2630 95 40.1 186 0.68 3181 120 44.8 216 0.55 3811 150 47.2 250 0.44 4745 185 53.5 287 0.37 5563 240 59.3 342 0.3 6861 Note 1: These ratings are per SANS 0142 table 6.7(a) Information shown is for 4 core. -2, 3 and 7 core information available on request

SINGLE CORE ALUMINIUM XLPE PVC CABLE 29 Wooden drums 300m & 500m Plain hard drawn stranded aluminium conductor, XLPE insulated, unarmoured with a PVC sheath Power distribution: distribution panels and transformers SPECIFICATION: SANS 1507 Voltage Rating: 1900 / 3300V Temperature range: -10 C to 90 C Sheath colours: Black (other colours on request) NOMINAL STRANDING No. x APPROX. OVERALL CURRENT RATING VOLTAGE DROP APPROX. CABLE WEIGHT (Nominal diameters) (mm 2 ) (mm) (A) (MV/A/M) (Kg/Km) Insulation Sheath 120 37 x 2.03 18 21.8 290 0.6 590 150 37 x 2.25 20 23.3 337 0.49 686 185 37 x 2.52 21 25.6 391 0.41 840 240 61 x 2.25 24 27.9 465 0.34 1014 300 61 x 2.52 26 30.1 540 0.29 1199 400 61 x 2.80 29 33.4 625 0.24 1495 500 61 x 3.20 33 37.5 714 0.21 1890 630 91 x 2.97 37 41.3 800 0.19 2319

30 ALUMINIUM FLAME RETARDENT (FR) ARMOURED CABLE 1.9/3.3KV Wooden drums 300m & 500m Plain Hard drawn Aluminium conductors, XLPE insulated, PVC bedded, Galvanised Steel Wire. Armoured, PVC (FR) Sheathed. The use of intermediate voltage represents a considerable cost saving compared to the conventional systems through the ability to convey increased power over longer distances with smaller conductor sizes. Suitable for direct burial installations as well as in air or ducts. The flame retardency in the PVC prevents the spread of fires. SPECIFICATIONS: SANS 1507/4 Voltage rating: 1900 / 3300V Core colours: 3 core - Red, Yellow and Blue Sheath colours: Black with Red stripe CURRENT RATING () APPROX. OVERALL () APPROX. CABLE WEIGHT (mm2) (mm) (Amps) (MV/A/M) (Kg/Km) 25 29 80 2.5 1320 35 30 99 1.81 1598 50 34 119 1.34 1879 70 38 151 0.933 2569 95 42 186 0.681 3061 120 46 216 0.54 3507 150 50 250 0.45 4433 185 52 287 0.36 4837 240 58 342 0.29 5859 Note 1: These ratings are per SANS 0142 Table 6.7

ALUMINIUM LOW HALOGEN (LHC) ARMOURED CABLE 1.9/3.3KV 31 Wooden drums 300m & 500m Plain Hard drawn Aluminium conductors, XLPE insulated, PVC bedded, Galvanised Steel Wire Armoured, PVC (LH) Sheathed. The use of intermediate voltage represents a considerable cost saving compared to the conventional systems through the ability to convey increased power over longer distances with smaller conductor sizes. Suitable for direct burial installations as well as in air or ducts. The PVC in LH Cable is specially formulated to reduce corrosive gasses which are produced by burning PVC, so are suitable for use in closed areas such as mines and offices. SPECIFICATIONS: SANS 1507/4 Voltage rating: 1900 / 3300V Core colours: 3 core - Red, Yellow and Blue Sheath colours: Black with Blue stripe CURRENT RATING () APPROX. OVERALL () APPROX. CABLE WEIGHT (mm2) (mm) (Amps) (MV/A/M) (Kg/Km) 25 29 80 2.5 1320 35 30 99 1.81 1598 50 34 119 1.34 1879 70 38 151 0.933 2569 95 42 186 0.681 3061 120 46 216 0.54 3507 150 50 250 0.45 4433 185 52 287 0.36 4837 240 58 342 0.29 5859 Note 1: These ratings are per SANS 0142 Table 6.7

32 COAXIAL CABLE Shrink-wrapped reels 100m RG6U TV coaxial cable 75 ohm 100 meters. A coaxial cable has a solid copper or copper-clad-steel centre conductor surrounded by a non-conductive dielectric insulating material. The dielectric is surrounded by foil shield/s and/or copper braid/s which form the outer conductor and also shield against electromagnetic interference (EMI). The outer conductor/shield is encased in a PVC jacket. Most coaxial cables for video applications have a nominal impedance of 75 ohms. Their differing electrical and physical characteristics make it important to select the correct type of cable to suit the application. CABLE LENGTH IMPEDANCE JACKET FOIL BRAID CORE COLOUR 100m 75 ohms 6.80mm PVC Aluminium/Pet 64/0.12mm Aluminium Copper coated steel White

EXTENSION CORDS 33 PRODUCT DESCRIPTION COLOURS Extension cords 3m 10 Amp / 16 Amp Double socket White 5m 10 Amp / 16 Amp Double socket White 7.5m 10 Amp / 16 Amp Double socket White 10m 10 Amp / 16 Amp Double socket White 15m 10 Amp / 16 Amp Double socket White 20m 10 Amp / 16 Amp Double socket White Dedicated extension cords 3m 10 Amp Double dedicated socket 5m 10 Amp Double dedicated socket 10m 10 Amp Double dedicated socket 15m 10 Amp Double dedicated socket Red Red Red Red

34 CABLE ACCESSORIES - CONDUIT 100m Bundles PRODUCT SPECIFICATION UNITS PER PACK STANDARD LENGTHS 20mm 25 4m 25mm 25 4m 32mm 10 4m

QUICK CABLE SELECTION GUIDE 35 A B C DISTANCE BETWEEN POWER SUPPLY & LOAD METERS 2700 2000 1400 1000 900 800 700 600 500 400 300 200 MOTOR SIZE IN HORSE POWER & KILLOWATTS AMPS PER PHASE 1 1.75 2 1.5 3 1 2.2.75 4 3 5 4 6 2 1.5 7.5 3 2.2 5 4 6 7.5 SINGLE PHASE 10 7.5 12 15 11 20 15 25 18.5 30 22 35 40 30 50 37 60 45 75 80 90 90 2 3 4 5 6 7 8 9 10 12 15 20 25 30 40 50 60 70 80 90 100 150 4MM 6MM 10MM 16MM 25MM 35MM 70MM FOR ANY GIVEN LOAD OVER A DISTANCE OF 100 METERS AND OVER INSTRUCTIONS FOR USE: 1. From column B, select the size of the motor, ie: HORSEPOWER/KILOWATT Alternatively, if the motor current is known then select the current to be drawn NB: If working in HP/KW be careful to select 1 phase/3 phase as needed 2. Now select the distance from the motor to the distribution point under column A 3. Line a ruler up with the points selected on both A and B and look at column C for conductor size of the cable needed for the given installation 150 3 PHASE 200 HORSE POWER KILOWATT AMPS PER PHASE 95MM

36 SABS CERTIFICATION