www. ElectricalPartManuals. com Instructions for Cast Resin Bushing, 15 KV & Below

Similar documents
www. ElectricalPartManuals. com INSTRUCTIONS "INERTEEN AND OIL INSULATED FEEDER SWITCHES DESCRIPTION INSTALLATION MAINTENANCE

www. ElectricalPartManuals. com MECHANICAL RELIEF DEVICE

www. ElectricalPartManuals. com Instructions for Load Break Air Switch, Type LBF, for Power Centers

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

25 kv Apparatus Bushings

REPAIR PARTS LIST 31

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

U STYLE "TP" TIME RELEASE UNION SWITCH & SIGNAL DIVISION OF WESTINGHOUSE AIR BRAKE CO. INSTALLATION AND MAINTENANCE AUGUST, 1951

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Westinghouse Electric Corporation Distribution Apparatus Division Bloomington, Indiana 47401

15 kv and 25 kv Thru-Bushings

Swing-Flex Check Valve

PNO Condenser Bushings from 52 kv to 420 kv Oil-to-air - Oil-Impregnated Paper

Swing-Flex Check Valve

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

Installation Manual Bushings, IEEE/ANSI Standard

www. ElectricalPartManuals. com CPL Station Arrester Controlled Protective Level Page 1 Indoor-Outdoor Altitude 0-10,000 feet KV

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

Self-Priming Centrifugal Pumps Refer to pump manual for General Operating and Safety Instructions.

JUL 17 Rev M

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Heavy welded steel outlet half. 3/4-inch NPT test plug. Benefits

www. ElectricalPartManuals. com INSTRUCTIONS INTERLOCKED MOTOR-DRIVEN OPERATING MECHANISM For No-Load Tap Changers DESCRIPTION OPERATION MAINTENANCE

Maintenance Information

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

BUSHINGS: GENERAL INFORMATION

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

AJV8 Engine Assembly. AJV8 Engine Assembly

HARD FOLDING TONNEAU COVER INSTALLATION GUIDE

BR 31a Rack-and-pinion Actuator,

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Maintenance Information

Bus bar Bushings up to 1.1kV and from 1.6kA to 4kA for Liquid Filled Transformers:

Instruction Sheet Crimping Die Assemblies , , and

OIP Transformer Outdoor Bushings Type COT(C) 125 COT (C) kV to 550kV up to 5000A IEC

GBV-G Balancing Valves

HPS SERIES. Steam Joints DEUBLIN COMPANY Norman Drive, West Waukegan, IL USA Phone: 847/ Fax: 847/ Rev.

www. ElectricalPartManuals. com

Transformer bushings, type GOH. Technical guide

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

Bulletin 1494V Variable Depth, Flange Operated Disconnect Switch Kits for 400 and 600 Amperes (Series A) Switches

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

ATMOSPHERIC RELIEF VALVE

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Maintenance Information

SERVICE INSTRUCTIONS ASSEMBLY & DISASSEMBLY T50X DOUBLE ACTING HYDRAULIC SERIES ACTUATORS

1.28 ACCESSORY DRIVE. Accessory Drive Assembly Related Parts (Former Design) SERIES 60 SERVICE MANUAL. 1. Locknut 8. Drive Gear

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

PRESSURE REDUCING CONTROL VALVES

PV-250 Track Relay. Operating Values For Hz PV-250 Track Relay With 115 Volt Local 440 Turn Track Coil

ACCESSORIES FOR LPOF, HPPT AND XLPE HIGH VOLTAGE CABLE SYSTEMS PRODUCT CATALOGUE

Document: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Ford Brass Saddles Style 101B and 202B

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

Transportation Products

OWNER S GUIDE & INSTALLATION INSTRUCTIONS

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

Instructions for Replacing

W-Series Junction Boxes

SOLENOID CONTROL VALVE

1988 Chevrolet Pickup V SUSPENSION - FRONT (4WD)' 'Front Suspension - "V" Series 1988 SUSPENSION - FRONT (4WD) Front Suspension - "V" Series

General information on handling and maintenance of SDC TM Solid Dielectric Capacitor Bushings

UNIVERSAL JOINTS AND PROPELLER SHAFT

Removal and Installation of Fuel Injection Pumps

Fruitland 250,370 and 500 Pump Rebuild Procedure

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Instructions for Installation, Operation, Care and Maintenance

INSTRUCTION MANUAL. for BUTTERFLY VALVES

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

GH-BETTIS OPERATING & MAINTENANCE INSTRUCTIONS DISASSEMBLY & ASSEMBLY FOR THE T80X-M4-S DOUBLE ACTING SERIES HYDRAULIC ACTUATORS

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

M9000-3xx Series Weather Shield Enclosures

DESCRIPTION. 10" Square Valve 10" Valve for United Plastics Tank Valve Handle-Complete Assembly Auxilliary Handle Lock less Hardware (see page 12)

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

Transformer Bushing Type EKTO

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat


UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

Industrial Turbo Meters, Sizes 2" through 6"

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual

14 and Larger Wafer and Lug Style Dual Disc Check Valve. Operation, Maintenance and Installation Manual

Series V47 Temperature Actuated Modulating Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Ford Service Saddles and Tapping Sleeves

Product Specifications for Phase Over Phase GOABS(r)

Load Break Switch Type LBOR-II, Oil Immersed PTAT-LIR975 IZUA Technical Guide Nut Mount Weld Mount

Swing Check Valves

Instructions for changing bearings on all B&C Technologies SP and HP models

Transportation Valves

Transcription:

Instructions for Cast Resin Bushing, 15 KV & Below Fig. 1 Cast Resin Bushing The Westinghouse Cast Resin Bushing, used for voltages 15KV and below, is made by casting an insulating resin around the conductor. The flange is cast as an integral part of the insulating shell. A recessed groove around the underside of the cast flange provides a gasket retainer. To prevent excessive mechanical loading of the bushing, only flexible connections should be made to the bushing conductor. The conductor should not be used as a structural member to support other current carrying parts. The ends of the bushing conductor are flattened and drilled to facilitate bolting to other conductors. HANDLING AND STORAGE Care must be taken in handling the bushing to avoid cracking the resin or damaging its surface. I.L. 48-061-48 Store spare cast resin bushings in a clean, dry place in a vertical or horizontal position. MAINTENANCE The exposed insulating surface of the bushing should be cleaned periodically to prevent accumulation of contamination. When installing the bushing, cement a new gasket in the gasket recess on the underside of the flange to insure that the gasket is properly seated in the groove. Use a 1/4 inch thick cork-buna "N" gasket on Inerteen -filled transformers and a 7/32 inch thick cork-neoprene gasket on oilfilled transformers. A 1 inch outside diameter metal washer should be placed between the mounting nut and the flange. After the nuts are finger tight, each one should be tightened half a turn in sequence until the flange is approximately.010 inches from the tank wall all around the edge. RENEWAL PARTS If renewal parts are required, order from the nearest Westinghouse Sales Office, giving description of parts wanted, with transformer serial number and rating as stamped on transformer instruction plate. Westinghouse Electric Corporation Power Transformer Division, Sharon, Pa. Effec:ive October, 1966 Printed in U.S. A. (T. P.l

Instructions for Draw Lead Bushing, Type RJ Nema Standard DRAW LEAD TERMINAL TERMINAL CAP 5--- gfsiff LING SILICONE RUBBER tl---- GASKET FIG. 1 Typical Cross-Section of ''RJ" Draw Lead Bushing The Westinghouse Draw Lead Bushing, type "RJ", conforms to Nema Standard dimensions and is used for voltages 15 KV and lower, up to 600 amperes. This bushing is made of a single piece, wet process porcelain with a one-piece forged aluminum flange rolled into a groove in the porcelain over a silicone rubber gasket. The draw lead terminal is provided with a steel pin through its diameter. The pin extends beyond the terminal on both sides and engages in a slot provided in the porcelain near the top. The terminal cap screws on to the top end of the draw-lead terminal which extends beyond the top of the porcelain. A nitrile, reuseable gasket provides a seal between the terminal cap and the porcelain. See Fig. 1. Effective December, 1970 HANDLING AND STORING I. L 48-061-63 Care must be taken in handling the bushing to avoid cracking the porcelain or damaging its surface. Bushings should be stored in a clean, dry place. INSTALLATION These bushings are usually shipped mounted in place on the transformer. The bushing is mounted on a boss which is welded to the transformer tank cover. A recessed groove in the boss contains a nitrile reuseable gasket to seal between the bushing flange and the boss. When the mounting nuts are tightened, the flange and boss are drawn together to make a metal-to-metal gasket stop. The terminal which is crimped to the draw lead has a steel pin pressed through a hole in the terminal diameter below the threads. About 1/4 inch of pin extends on both sides of the terminal to engage a slot inside the porcelain top end. A hole at the top of the draw lead terminal facilitates holding the lead while sliding the bushing over it into position. When the draw lead terminal is properly engaged in the slot about 1/2 inch of thread protrudes above the porcelain top. A stiff draw lead will remain in position. However, it may be necessary to hold some leads by pressing between threads of the terminal with a screw driver until the terminal cap is partially threaded onto the draw lead terminal. A thin coating of petrolatum is applied to the top surface of the terminal gasket. The coated side of the gasket is then pressed against the terminal cap gasket seat and held in place. The terminal cap has a tapped hole in the bottom and is screwed onto the draw lead terminal until hand tight. The gasket should be properly seated and the terminal cap centered on the porcelain. To obtain proper compression of the gasket the terminal cap is turned 1/2 turn with a wrench after tightening as much as possible by hand.

2 RENEWAL PARTS If renewal parts are required, order from the nearest Westinghouse Sales Office, giving Westinghouse Electric Corporation POWER TRANSFORMER DIVISION SHARON, PA. MUNCIE, IND. S. BOSTON, VA. description of parts wanted, with transformer serial number and rating as stamped on transformer instruction plate. Printed in U.S.A. (W.E.)

Instructions for Cast Resin Bushing, 15 KV & Below Fig. 1 Cast Resin Bushing The Westinghouse Cast Resin Bushing, used for voltages 15KV and below, is made by casting an insulating resin around the conductor. The flange is cast as an integral part of the insulating shell. A recessed groove around the underside of the cast flange provides a gasket retainer. To prevent excessive mechanical loading of the bushing, only flexible connections should be made to the bushing conductor. The conductor should not be used as a structural member to support other current carrying parts. The ends of the bushing conductor are flattened and drilled to facilitate bolting to other conductors. HANDLIJ\G AND STORAGE Care must be taken in handling the bushing to avoid cracking the resin or damaging its surface. I. L. 48-061-48 Store spare cast resin bushings in a clean, dry place in a vertical or horizontal position. MAINTENANCE The exposed insulating surface of the bushing should be cleaned periodically to prevent accumulation of contamination. When installing the bushing, cement a new gasket in the gasket recess on the underside of the flange to insure that the gasket is properly seated in the groove. Use a 1/4 inch thick cork-buna "N" gasket on Inerteen -filled transformers and a 7/32 inch thick cork-neoprene gasket on oilfilled transformers. A 1 inch outside diameter metal washer should be placed between the mounting nut and the flange. After the nuts are finger tight, each one should be tightened half a turn in sequence until the flange is approximately. 010 inches from the tank wall all around the edge. RENEWAL PARTS If renewal parts are required, order from the nearest Westinghouse Sales Office, giving description of parts wanted, with transformer serial number and rating as stamped on transformer instruction plate. Westinghouse Eiectric Corporation Power Transformer Division, Sharon, Pa. Effective October, 1966 Print in U.S. A. (T. P. I

Instructions for Draw Lead Bushing, Type RJ Nema Standard DRAW LEAD TERMINAL TERMINAL CAP CAP SEALING 5---- GASKET WET PROCESS 1---- PORCELAIN SILICONE RUBBER '0--- GASKET FIG. I Typical Cross-Section of "RJ" Draw Lead Bushing The Westinghouse Draw Lead Bushing, type "RJ", conforms to Nema Standard dimensions and is used for voltages 15 KV and lower, up to 600 amperes. This bushing is made of a single piece, wet process porcelain with a one-piece forged aluminum flange rolled into a groove in the porcelain over a silicone rubber gasket. The draw lead terminal is provided with a steel pin through its diameter. The pin extends beyond the terminal on both sides and engages in a slot provided in the porcelain near the top. The terminal cap screws on to the top end of the draw-lead terminal which extends beyond the top of the porcelain. A nitrile, reuseable gasket provides a seal between the terminal cap and the porcelain. See Fig. I. Effective December, 1970 HANDLING AND STORING I. L. 48-061-63 Care must be taken in handling the bushing to avoid cracking the porcelain or damaging its surface. Bushings should be stored in a clean, dry place. INSTALLATION These bushings are usually shipped mounted in place on the transformer. The bushing is mounted on a boss which is welded to the transformer tank cover. A recessed groove in the boss contains a nitrile reuseable gasket to seal between the bushing flange and the boss. When the mounting nuts are tightened, the flange and boss are drawn together to make a metal-to-metal gasket stop. The terminal which is crimped to the draw lead has a steel pin pressed through a hole in the terminal diameter below the threads. About l/4 inch of pin extends on both sides of the terminal to engage a slot inside the porcelain top end. A hole at the top of the draw lead terminal facilitates holding the lead while sliding the bushing over it into position. When the draw lead terminal is properly engaged in the slot about 1/2 inch of thread protrudes above the porcelain top. A stiff draw lead will remain in position. However, it may be necessary to hold some leads by pressing between threads of the terminal with a screw driver until the terminal cap is partially threaded onto the draw lead terminal. A thin coating of petrolatum is applied to the top surface of the terminal gasket. The coated side of the gasket is then pressed against the terminal cap gasket seat and held in place. The terminal cap has a tapped hole in the bottom and is screwed onto the draw lead terminal until hand tight. The gasket should be properly seated and the terminal cap centered on the porcelain. To obtain proper compression of the gasket the terminal cap is turned 1/2 turn with a wrench after tightening as much as possible by hand.

2 RENEWAL PARTS If renewal parts are required, order from the nearest Westinghouse Sales Office, giving Westinghouse Electric Corporation POWER TRANSFORMER DIVISION SHARON, PA. MUNCIE, IND. S. BOSTON, VA. description of parts wanted, with transformer serial number and rating as stamped on transformer instruction plate. Printed in U.S.A. (W.E.)