AXICOM Telecom-, Signal and RF Relays. W11 Relay V Nov. 07 Rev. C ECOC: JM10

Similar documents
PCB Relay. Contact form Terminal Single-side stable Single-winding latching

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

1 Form A 5A small size power relay for interface

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

PCB Relay RC FCC. Ordering Information. Fully Sealed Relay with High Impulse Dielectric for Use in Telecommunications Equipment

Features. * 2 Form C contact. * High switching capacity 60W, 125VA. * Fit standard 16 pin IC socket. * Epoxy sealed for automaitc-wave COIL

PCB Relay. 2. Contact Form 2: DPDT 3. Terminal Shape None: PCB terminal F: Surface mount terminal

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

55 Series - Miniature General Purpose Relays 5-10 A

40 Series - Miniature PCB relays A. Features

Signal Signal Relays. Potter & Brumfield. R10 Series Relay

Industrial Relay KML(1C, 2C)

General Purpose Relays Industrial Relays. Power Relay RM 2/3/7

AC 250V AC 250V AC 250V AC 250V DC 110V DC 110V DC 110V DC 110V Max. Allowable Current 15A 10A 10A 10A

PCB Relay. Single-side stable EN60950/EN41003 PCB terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y Surface mounting. stable

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

RI-80 SMDH Series Housed Dry Reed Switch

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Ordering Information. Text Surface-Mounting Signal Relay G6K

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

Ordering Information. Text PCB Power Relay G5LE

PCB Relay. Ordering Information. Surface Mounting DPDT Relay G6S

5 mm contact pin pitch PCB or 95 series sockets

Type Contact form Model Plug-in socket/solder terminals Hermetically sealed 4PDT MY4H-US

General Purpose Relay

RUC industrial relays of small dimensions

General Purpose Low Power PCB Relays

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Automotive Relays PCB Single Relays. Micro Relay K (THT THR)

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load G6C - - VDC

High Current Solutions High Current Devices

Model Number Structure

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

2 pole 10 A PCB mount A1 A

Z b. General Purpose Relays PCB Relays SCHRACK. Power PCB Relay RT1

FINDER RELAYS & MODULAR TIMERS IN STOCK AT MARSH ELECTRONICS

Pluggable interface relays RT, PT and MT range

PCB Relay RC+ Ordering Information. Subminiature Relay that Switches up to 5 A G6B VDC

2 pole, 10 A power contacts 8 pin plug-in CO (DPDT) 3 CO (3PDT) Rated current/maximum peak current

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

Power Contactor with Mirror Contacts

2c 15A, 4c 10A polarized power relays

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

T75S5D Product Details

Type List. Standard Type. High Power Type

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

MasterINTERFACE 39 Series - Relay interface modules

Slim P.C.B. Relays (EMR or SSR) A

Features. Type List. Enclosure style. Terminal style. Contact. Sealed type washable. form Dust cover Flux tight

60 Series - General purpose relays 6-10 A. Features SERIES

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Type List. Standard Type. High Power Type. Designation (provided with) Terminal style Contact form Contact gap

General Purpose Relays Power Relays. T9G series, DC coil 30A PCB Relay

General Purpose Relay

General purpose relays 6-10 A

RT Product Details

Series 858, Relay Sockets with Industrial Relay

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

General Purpose Relay

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS

G7L. A High-capacity, High-dielectric-strength Relay Compatible with Momentary Voltage Drops. Application Examples. Model Number Legend

Miniature Intermediate Power Relay HY

Features. Type List 832A

Model Number Structure

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

PCB Relay. Ordering Information. Compact, Low-cost 30-A Power Relay for PC Board or Panel-mounted Applications G8P - - VDC

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

G7S Safety Relay. Ordering Information. Safety Relay conforming to EN standard G7S. Accessories Safety Relay Sockets

DPDT BTA12-2C-S-C BTA12-2C-S-CL BTA12-2C-S-CLM SPST-NO-DM BTA12-1X-S-C BTA12-1X-S-CL BTA12-1X-S-CLM

Plug-in relays Mini ISO relays

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

PG02S Series 2W DC/DC CONVERTER, SIP-Package

COMPACT FLAT SIZE FOR AUTOMOTIVE

Twin relays. Twin coil relays TCR and TCR-F. Convenience. Powertrain Systems. Safety Security Body Driver Information.

Features. Type List A

Square D General Purpose Relays

RELAYS G E N E R A L P U R P O S E & P O W E R R E L A Y S.

6mm and 14mm Slim Interface Relay

BENEFITS 782 STANDARD PART NUMBERS FEATURES 782 XDX M4L- 120A ORDERING CODE DPDT 10 AMP & 4PDT 3 & 5 AMP MINIATURE POWER RELAY FLAG INDICATOR:

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

COMPACT FLAT SIZE FOR AUTOMOTIVE

Miniature Industrial relay 8-16 A

Miniature General Purpose Relay HY

Magnetic and Hydraulic-Magnetic Circuit Breaker

W Datasheet: DIN Rail Contactors, series AMPARO

EB Series Eighth - Brick Up to 100 Watt DC-DC Converter

General Purpose Relay

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

Type Terminal Coil Contact form Model

Customized switching solutions High current solutions

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Transcription:

108-98010 Nov. 07 Rev. C ECOC: JM10

Disclaimer While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this datasheet, Tyco Electronics does not guarantee that it is error-free, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties (and all express warranties, except as otherwise stated in this datasheet) regarding the information contained herein, including but not limited to any implied warranties or merchantability or fitness for a particular purpose. It is recommended that you test any new or replacement product before incorporating into a system. The dimensions in this datasheet are for reference purpose only and are subject to change without notice. Specifications are subject to change without notice. Index UL 508 File No. E 111441 Dimensions 4 Coil Data and operating range 6 Relay Code 9 Contact Data 10 Insulation / General Data 11 All specifications subject to change. Consult Tyco Electronics for latest specifications. 2 of 13

1 pole PCB relay, non-polarized, Through Hole Type (THT) ROHS compliant (Directive 2002/95/EC) as per product date code 0401. Features Multi purpose relay Small size permitting high packing density 1 changeover contact (1 form C / SPDT) 200 mw and 450 mw coils 1 A and 3 A contacts High shock resistance of 30 g Ambient temperature for sensitive version up to 85 C Immersion cleanable Typical applications Security devices Electric door openers Duplex intercommunication systems Measurement and controls Relay types Non-latching, 1 coil Terminal assignments symmetrical or asymmetrical 5- or 6-pin version All specifications subject to change. Consult Tyco Electronics for latest specifications. 3 of 13

Dimensions Dimensions in mm L W H T mm 15.5 ± 0.1 10.5 ± 0.1 11.5-0.2 3.5-0.2 THT V23101-Dxxx-Xxxx inch 0.610 ± 0.004 0.413 ± 0.004 0.453-0.008 0.138-0.008 THT Version Mounting hole layout View onto the component side of the PCB (top view) Version: 6 pins Version: 5 pins (without pin no. 6) All specifications subject to change. Consult Tyco Electronics for latest specifications. 4 of 13

Terminal assignment Relay top view V23101-D0 xxx-axxx 6 pin version with symmetrical coil assignment V23101-D1 xxx-axxx 5 pin version with symmetrical coil assignment V23101-D0 xxx-bxxx 6 pin version with asymmetrical coil assignment V23101-D1 xxx-bxxx 5 pin version with asymmetrical coil assignment All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 13

Coil Data (values at 20 C) Ordering Information Nominal Voltage Unom Operating voltage range Minimum Voltage Umin Maximum voltage Umax Release/ reset voltage Minimum Coil power mw Coil Resistance Ω ± 15% Relay code Tyco part number 6 pin version with symmetrical coil assignment, 450 mw nom. Power consumption, AgPd+Au contacts 1.5 1.3 2.6 0.15 375 6 V23101-D0001-A201 1393779-1 3 2.1 4.7 0.30 450 20 V23101-D0002-A201 1393779-3 5 3.5 7.9 0.50 446 56 V23101-D0003-A201 1393779-5 6 4.2 9.5 0.60 450 80 V23101-D0004-A201 1393779-8 9 6.3 14.2 0.90 450 180 V23101-D0005-A201 1-1393779-1 12 8.4 19.0 1.20 450 320 V23101-D0006-A201 1-1393779-3 24 16.8 38.0 2.40 450 1280 V23101-D0007-A201 1-1393779-8 6 pin version with asymmetrical coil assignment, 450 mw nom. Power consumption, AgPd+Au contacts 1.5 1.3 2.6 0.15 375 6 V23101-D0001-B201 1393779-2 3 2.1 4.7 0.30 450 20 V23101-D0002-B201 1393779-4 5 3.5 7.9 0.50 446 56 V23101-D0003-B201 1393779-6 6 4.2 9.5 0.60 450 80 V23101-D0004-B201 1-1393779-0 9 6.3 14.2 0.90 450 180 V23101-D0005-B201 1-1393779-2 12 8.4 19.0 1.20 450 320 V23101-D0006-B201 1-1393779-6 24 16.8 38.0 2.40 450 1280 V23101-D0007-B201 2-1393779-2 6 pin version with symmetrical coil assignment, 450 mw nom. Power consumption, AgNi contacts 12 8.4 19.0 0.20 450 320 V23101-D0006-A301 4-1419172-4 6 pin version with asymmetrical coil assignment, 450 mw nom. Power consumption, AgNi contacts 5 3.5 7.9 0.50 446 56 V23101-D0003-B301 1393779-7 12 8.4 19.0 1.20 450 320 V23101-D0006-B301 1-1393779-7 24 16.8 38.0 2.40 450 1280 V23101-D0007-B301 2-1393779-1 6 pin version with symmetrical coil assignment, 450 mw nom. Power consumption, AgNi+Au contacts 5 3.5 7.9 0.50 446 56 V23101-D0003-A401 1422028-2 12 8.4 19.0 1.20 450 320 V23101-D0006-A401 1422028-3 24 16.8 38.0 2.40 450 1280 V23101-D0007-A401 1422028-5 6 pin version with asymmetrical coil assignment, 450 mw nom. Power consumption, AgNi+Au contacts 12 8.4 19.0 1.20 450 320 V23101-D0006-B401 1422028-4 24 16.8 38.0 2.40 450 1280 V23101-D0007-B401 1422028-6 5 pin version with symmetrical coil assignment, 450 mw nom. Power consumption, AgPd+Au contacts 12 8.4 19.0 1.20 450 320 V23101-D1006-A201 4-1393779-1 5 pin version with asymmetrical coil assignment, 450 mw nom. Power consumption, AgPd+Au contacts 5 3.5 7.9 0.50 446 56 V23101-D1003-B201 4-1393779-0 12 8.4 19.0 1.20 450 320 V23101-D1006-B201 4-1393779-2 24 16.8 38.0 2.40 450 1280 V23101-D1007-B201 1413012-1 5 pin version with symmetrical coil assignment, 450 mw nom. Power consumption, AgNi+Au contacts 12 8.4 19.0 1.20 450 320 V23101-D1006-A401 1-1422028-2 5 pin version with asymmetrical coil assignment, 450 mw nom. Power consumption, AgNi+Au contacts 12 8.4 19.0 1.20 450 320 V23101-D1006-B401 1-1422028-3 All specifications subject to change. Consult Tyco Electronics for latest specifications. 6 of 13

Coil Data (values at 20 C) Ordering Information Nominal Voltage Unom Operating voltage range Minimum Voltage Umin Maximum voltage Umax Release/ reset voltage Minimum Coil power mw Coil Resistance Ω ± 15% Relay code Tyco part number 6 pin version with symmetrical coil assignment, 200 mw nom. Power consumption, AgPd+Au contacts 1.5 1.1 3.6 0.15 188 12 V23101-D0101-A201 2-1393779-2 3 2.3 7.1 0.30 200 45 V23101-D0102-A201 2-1393779-4 5 3.8 11.6 0.50 208 120 V23101-D0103-A201 2-1393779-6 6 4.5 14.2 0.60 200 180 V23101-D0104-A201 2-1393779-8 9 6.8 21.2 0.90 203 400 V23101-D0105-A201 3-1393779-0 12 9.0 28.0 1.20 206 700 V23101-D0106-A201 3-1393779-2 24 18.0 56.0 2.40 206 2800 V23101-D0107-A201 3-1393779-5 18 13.5 33.0 1.80 200 1620 V23101-D0108-A201 3-1393779-9 6 pin version with asymmetrical coil assignment, 200 mw nom. Power consumption, AgPd+Au contacts 1.5 1.1 3.6 0.15 188 12 V23101-D0101-B201 2-1393779-3 3 2.3 7.1 0.30 200 45 V23101-D0102-B201 2-1393779-5 5 3.8 11.6 0.50 208 120 V23101-D0103-B201 2-1393779-7 6 4.5 14.2 0.60 200 180 V23101-D0104-B201 2-1393779-9 9 6.8 21.2 0.90 203 400 V23101-D0105-B201 3-1393779-1 12 9.0 28.0 1.20 206 700 V23101-D0106-B201 3-1393779-3 24 18.0 56.0 2.40 206 2800 V23101-D0107-B201 3-1393779-8 6 pin version with symmetrical coil assignment, 200 mw nom. Power consumption, AgNi contacts 12 9.0 28.0 1.20 206 700 V23101-D0106-A301 1422037-2 24 18.0 56.0 2.40 206 2800 V23101-D0107-A301 3-1393779-7 6 pin version with asymmetrical coil assignment, 200 mw nom. Power consumption, AgNi contacts 12 9.0 28.0 1.20 206 700 V23101-D0106-B301 3-1393779-4 6 pin version with symmetrical coil assignment, 200 mw nom. Power consumption, AgNi+Au contacts 5 3.8 11.6 0.50 208 120 V23101-D0103-A401 1422028-7 12 9.0 28.0 1.20 203 700 V23101-D0106-A401 1422028-8 24 18.0 56.0 2.40 206 2800 V23101-D0107-A401 1422028-9 18 13.5 33.0 1.80 200 1620 V23101-D0108-A401 1-1422028-1 6 pin version with asymmetrical coil assignment, 200 mw nom. Power consumption, AgNi+Au contacts 24 18.0 56.0 2.40 206 2800 V23101-D0107-B401 1-1422028-0 5 pin version with symmetrical coil assignment, 450 mw nom. Power consumption, AgPd+Au contacts 12 9.0 28.0 1.20 203 700 V23101-D1106-A201 4-1393779-3 24 18.0 56.0 2.40 206 2800 V23101-D1107-A201 4-1393779-6 5 pin version with asymmetrical coil assignment, 450 mw nom. Power consumption, AgPd+Au contactsw 12 9.0 28.0 1.20 203 700 V23101-D1106-B201 4-1393779-4 24 18.0 56.0 2.40 206 2800 V23101-D1107-B201 4-1393779-7 5 pin version with asymmetrical coil assignment, 200 mw nom. Power consumption, AgNi contacts 12 9.0 28.0 1.20 203 700 V23101-D1106-B301 4-1393779-5 5 pin version with symmetrical coil assignment, 200 mw nom. Power consumption, AgNi+Au contacts 12 9.0 28.0 1.20 203 700 V23101-D1106-A401 1-1422028-4 5 pin version with asymmetrical coil assignment, 200 mw nom. Power consumption, AgNi+Au contacts 12 9.0 28.0 1.20 203 700 V23101-D1106-B401 1-1422028-5 All specifications subject to change. Consult Tyco Electronics for latest specifications. 7 of 13

Coil Operating Range Coil Voltage [U/Unom] 2.6 2.4 2.2 2 1.8 1.6 1.4 1.2 1 0.8 Unom. nominal coil voltage 200 mw coil Umax. at 0 A Umax. at 1.25 A Unom = Umax. = Uop. min. = Urel. min. = Nominal coil voltage Upper limit of the operative range of the coil voltage (limiting voltage) Lower limit of the operative range of the coil voltage (reliable operate voltage) For latching relays Uset min. resp. Ureset min. Lower limit of the operative range of the coil voltage (reliable release voltage) 0.6 Uop. min. 0.4 Urel. min. 0.2 0-40 -30-20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature [ C] 2.6 2.4 450 mw coil 2.2 2.0 Umax. at 0 A Umax. at 1.25 A Coil Voltage [U/Unom] 1.8 1.6 1.4 1.2 1.0 0.8 Unom. nominal coil voltage 0.6 0.4 Uop. min. Urel. min. 0.2 0.0-40 -30-20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature [ C] All specifications subject to change. Consult Tyco Electronics for latest specifications. 8 of 13

Relay Code V 2 3 1 0 1 Identification of the Relay W11-1 changeover contact Pin version D0 = Standard 6 pins D1 = 5-pin version (without pin no. 6) Coil number Standard version 001 = 1.5 V nominal voltage 002= 3 V 003 = 5 V 004 = 6 V 005 = 9 V 006 = 12 V 007 = 24 V Sensitive version 101 = 1.5 V nominal voltage 102= 3 V 103 = 5 V 104 = 6 V 105 = 9 V 106 = 12 V 107 = 24 V Coil assignment A = Symmetrical B = Asymmetrical Contact / Material 201 = AgPd, gold plated 301 = AgNi 401 = AgNi, gold plated Ordering example: V23101-D0104-B401 Small relay W11-1 changeover contact, standard pin version (6 pins), sensitive version, coil 6 V nominal voltage, terminal assignment B, contact material AgNi, gold plated. Note: Special designs can be carried out to customer specifications. Please contact your local representative. All specifications subject to change. Consult Tyco Electronics for latest specifications. 9 of 13

Contact Data Number of contacts and type Contact assembly Contact material AgPd, gold plated AgNi, gold plated 1 changeover contacts single contacts Limiting continuous current at max. ambient temperature 1.25 A 3 A Maximum switching current (see load limit diagram) 1.25 A 3 A Maximum swichting voltage 120 125 Vac AgNi 120 125 Vac Maximum switching capacity 30 W / 62.5 VA 72 W / 360 VA Thermoelectric potential < 10 µv < 10 µv Initial contact resistance / measuring condition: 10 ma / 20 mv 100 mω 100 mω Electrical endurance standard: at 24 / 1.25 A at 24 / 3 A at 120 Vac / 1.25 A at 120 Vac / 3 A min. 3 x 10 5 operations min. 1.5 x 10 5 operations min. 2 x 10 5 operations min. 4 x 10 5 operations sensitive: at 24 / 1.25 A at 24 / 3 A at 120 Vac / 1.25 A at 120 Vac / 3 A min. 2 x 10 5 operations min. 1 x 10 5 operations min. 1 x 10 5 operations min. 3 x 10 5 operations Mechanical endurance, typ 10 7 operations Max. DC Load Breaking Capacity DC Voltage [] DC current [A] All specifications subject to change. Consult Tyco Electronics for latest specifications. 10 of 13

Insulation Insulation resistance at 500 Dielectric test voltage (1 min) between coil and contacts between open contacts > 10 9 Ω 1000 Vrms 750 Vrms High Frequency Data Capacitance between coil and contacts between open contacts max. 10 pf max. 2 pf General Data Operate time at Unom typ./ max. Release time without diode in parallel, typ. / max. Release time with diode in parallel, typ. / max. Bounce time at closing contact, typ. / max. 5 ms / 7 ms 3 ms / 5 ms 10 ms / 12 ms 1 ms / 2 ms NO contact 5 ms / 10 ms at NC conctact Maximum switching rate without load 20 operations/s Ambient temperature -40 C... +70 C / 85 C, standard / sensitive coil Thermal resistance < 125 K/W Maximum permissible coil temperature 130 C Vibration resistance (function) 10 G, 10 to 200 Hz Shock resistance, half sinus, 11 ms 30 G (function) 100 G (damage) Degree of protection immersion cleanable, IP 67 Needle flame test application time 20 s, burning time < 15 s Mounting position any Processing information Ultrasonic cleaning is not recommended Weight (mass) max. 4 g Terminal coating SnCu 0,7 Resistance to soldering heat 265 C / 10 s Packing Dimensions in mm Tube dimensions 25 relays per tube 625 relays per box All specifications subject to change. Consult Tyco Electronics for latest specifications. 11 of 13

IM Relays 4th generation slim line low profile polarized 2 c/o telecom signal relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 1.5... 24 V, coil power consumption of 50... 200 mw, latching relays with 1 coil 100 mw. The IM relay is available as through hole and surface mount type (J-Legs and Gull Wings) and capable to switch loads up to 60 W/62,5 VA. It is currently the only 2 A rated 4G relay on the market. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kv 2 / 10 µs) and FCC part 68 (1,5 kv 10 / 160 µs). The IM relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 10 x 6 mm board space and 5.65 mm height. P2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3... 24 V, coil power consumption 140 mw, latching relays with 1 coil 70 mw. The P2 Relay is available as through hole or surface mount type and capable to switch currents up to 5 A. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kv 2 / 10 µs) and FCC part 68 (1,5 kv 10 / 160 µs). The P2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height. FX2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 coil. Nominal voltage range from 3... 48 V, coil power consumption of 80... 260 mw for the high sensitive version, 140... 300 mw for the standard version, latching relays with 1 coil 100 mw. The FX2 relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kv 2 / 10 µs) and FCC part 68 (1,5 kv 10 / 160 µs). The FX2 relay is tested according CECC/ IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10,7 mm height. FT2 / FU2 Relays 3rd generation non polarized, non latching 2 c/o telecom relay with bifurcated contacts. Nominal voltage range from 3... 48 V, coil power consumption 200... 300 mw. Most sensitive 48 V relay. Available as through hole and surface mount type. Dielectric strength fulfills the Telcordia requirements according GR 1089 (2,5 kv 2 / 10 µs) and FCC part 68 (1,5 kv 10 / 160 µs). The FT2/FU2 relay is tested according CECC/IECQ and certified in accordance with IEC/EN 60950 and UL 60950. Dimensions approx. 15 x 7,5 mm board space and 10 mm height. FP2 Relays 3rd generation polarized 2 c/o telecom relay with bifurcated contacts, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3... 48 V, coil power consumption of 80... 260 mw for the high sensitive version, 140... 300 mw for the standard version, latching relays with 1 coil 100 mw.. The FP2 Relay is available as through hole type and capable to switch loads up to 60 W/62,5 VA. Dielectric strength fulfills FCC part 68 (1,5 kv 10 / 160 µs). The FP2 is tested according CECC/IECQ approved. Dimensions approx. 14 x 9 mm board space and 5 mm height. MT2 2nd generation non polarized, non latching 2 c/o telecom and signal relay with bifurcated contacts. Nominal voltage range from 3... 48 V, coil power consumption 150/200/300/400 and 550 mw. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kv 10 / 160 µs). Dimensions approx. 20 x 10 mm board space and 11 mm height. D2n Relays 2nd generation non polarized 2 c/o relay for telecom and various other applications. Nominal voltage range from 3... 48 V, coil power consumption from 150... 500 mw. The D2n relay is capable to switch currents up to 3 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kv 10 / 160 µs). Dimensions approx. 20 x10 mm board space and 11 mm height. P1 Relays Extremely sensitive, polarized 1 c/o relay with bifurcated contacts for a wide range of applications, available as non latching or latching relay with 1 or 2 coils. Nominal voltage range from 3... 24 V, coil power consumption 65 mw, latching relays with 1 coil 30 mw. The P1 relay is available as through hole or surface mount type and capable to switch currents up to 1 A. Dielectric strength fulfills the requirements according FCC part 68 (1,5 kv 10 / 160 µs). Dimensions approx. 13 x 7,6 mm board space and 7 mm height for THT or 8 mm height for SMT version. W11 Relays Low cost, non polarized 1 c/o relay for various applications. Nominal voltage range from 3... 24 V, coil power consumption 450 mw, sensitive versions 200 mw. The W11 relay is capable to switch currents up to 3 A. Dielectric strength 1000 Vrms. Dimensions approx. 15,6 x 10,6 mm board space and 11,5 mm height. Reed Relays High sensitive, non polarized relay for telecom and various other applications, available with 1 n/o, 2 n/o or 1c/o contacts. Nominal voltage range from 5... 24 V, coil power consumption 50...280 mw for 1 n/o and 125... 280 mw for 2 n/o or 1 c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 1500. Dimensions approx. 19,3 x 7 mm board space and 5... 7,5 mm height for DIP or 19,8 x 5 mm board space and 7,8 mm height for SIL version. Cradle Relays Extremely reliable and mature relay family of 1st generation for various signal switching applications. Available as non polarized, polarized / latching and relay with AC coil. The benefit is the possibility of combining various contact sets from 1 up to 6 poles, single and bifurcated contacts, different contact materials with a coil voltage range from 1,5 to 220 Vac. Cradle relays are available as dust protected and hermetically sealed versions, with plug in or solder terminals and are capable to switch currents up to 5 A. Forcibly guided (linked) contact sets optional. Dielectric strength 500 Vrms. Dimensions from approx. 19 x 24 to 19x35 mm board space and 30 mm height. Other Relays We offer a variety of different relay families for maintenance and replacement purposes. These relays are up to 60 years old now, such as Card Relay SN (V23030 series), Small General Purpose Relay (V23006 series), Small Polarized Relay (V23063... V23067 and V23163... V23167 series). Accessories like sockets, hold down springs, etc. optional. High Frequency Relays HF3 / HF3S / HF6 series RF relays offering excellent RF characteristics in a small package. All HF series relays are suitable for SMD soldering processes. Available as non latching or latching versions with 1 or 2 coils and a nominal coil voltage range from 3 24 V, a coil power consumption of 140 mw or 70 mw (single coil latching types). HF3: Low cost RF relay suitable up to 3 GHz. Impedance 50 and 75 Ohm. 50 W hot switching and 50 W RF power carry capability. Dimensions 14.6 x 7.3 x 10.3 mm. HF3S: High performance, high power RF relay suitable up to 3 GHz, 50 W hot switching and 150 W RF power carry capability. Dimensions 15 x 7.6 x 10.6 mm. HF6: High performance, high power RF relay suitable up to 6 GHz, 50 W hot switching and 50 W RF power carry capability. Dimensions 15 x 7.6 x 10.6 mm. All specifications subject to change. Consult Tyco Electronics for latest specifications. 12 of 13

Tyco Electronics Logistics AG Werk Axicom Au Seestrasse 295 CH-8804 Au-Wädenswil / Switzerland Phone +41 44 782 91 11 Fax +41 44 782 90 00 E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenského 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com AXICOM Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +1 800-522-6752