ONYX VALVE CO. The Pinch Valve Authority

Similar documents
Wafer Butterfly Valves

The City of Sturgis Wastewater Treatment Plant Septage Waste Receiving Facility Operating Plan

AWWA Swing Check Valves

RAS & WAS Pumps (FLYGT Pump)

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

CCNE Check Valves Engineering Creative Solutions for Fluid Systems Since 1901

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

Check Valve MODEL. Schematic Diagram. Product Dimensions Data:

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Ballcentric Plug Valve

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

ENVIRONMENTAL & ENGINEERING SERVICES DEPARTMENT

ROTAMAT Sludge Acceptance Plant Ro 3

VB VALVES & AUTOMATION

Red Valve. The World Leader In Pinch Valve Technology MANUAL PINCH VALVES

PASCO PASCO PINCH VALVES

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

wipes ready technology

Series 800 AWWA Butterfly Valves

Wheels. performance. safety and. Crown s expertise. drives savings,

Valve and Piping Replacements Various Facilities Deer Island Treatment Plant

A ZURN Company Rotovalve Cone Valve 20 Questions

January 2016 GLOBE VALVES MIXING & DIVERTING SERIES 8600 MODEL Previously manufactured by Dezurik and Honeywell

ONYX VALVE CO MODEL GSF AND GSD Installation & Maintenance

Application. Key Features. Specifications

PLUG VALVE we PIPE ( ) Twice the tensile strength of cast iron Greater yield strength than steel

ECCENTRIC PLUG VALVES

ONYX VALVE CO MODEL DAC-ADA Installation & Maintenance

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

Pressure Distribution Design

Butterfly Valves. Jenkins Valves 254 Henry Street Brantford, Ontario N3T 5T7 Tel: Tel: Fax:

Series PV30. Split-Body Pinch Valve. CLA-VAL Copyright Cla-Val 2007 Printed in USA Specifications subject to change without notice.

Trash Hog II Self Priming Solids Handling Centrifugal Pumps

City Of London Environmental & Engineering Services Department Wastewater Treatment Operations

NE January 2016 THREE-WAY VALVES SERIES 1600 MODEL 1601 SERIES 1900 MODEL Previously manufactured by Dezurik and Honeywell

PN16 Resilient Seated Gate Valves DN50 - DN600

PackRyt Bearing Systems

PRESSURE REDUCING VALVE

AWWA SWING CHECK VALVES. Engineering Creative Solutions for Fluid Systems Since 1901

PRESSURE REDUCING VALVE

WATER and WASTE WATER Treatment

Available End Connections & Size Range

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

SERIES 2200 Replaceable Seat Butterfly Valves

Transportation Products

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

TREATMENTOF PETROCHEMICAL WASTEWATERS

Custom Fabricated and Cast Knife Gate Valves

ONYX VALVE CO MODEL DEC Installation & Maintenance

LPP PUMP LAROX PERISTALTIC PUMPS (LPP)

PRESSURE REDUCING CONTROL VALVE

GP & GH Range. Pneumatic and Hydraulic Actuators for Quarter-Turn Valves. Established Leaders in Actuation Technology

AUTOMATION ACCESSORIES IN-PLANT VALVE PRODUCTS EXTENSION STEMS FLOORBOX STEM GUIDES FLOORSTANDS COMMITTED TO ENVIRONMENTAL RESPONSIBILITY FLAP VALVES

LOW OPERATING COST LOW START-UP COST. Media TM has its own built-in. the initial savings over new mechanical

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

ISO-DE Double Eccentric Butterfly Valves

Sliding Frame Storage Systems

PRESSURE REDUCING VALVE

Sludge Management EENV Overview of Sludge Treatment & Disposal

2-inch operating nut (other options available) 10 millimeter fusion-bonded epoxy coating (NSF-61) Triple O-ring seal

Series 758 FireLock Actuated System Valve

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

SURGEBUSTER! BUILT WITH ADVANCED TECHNOLOGY TO WITHSTAND YOUR TOUGHEST APPLICATIONS. Air Release Air Valves. Air/Vacuum Air Valves

HAWLE-AIR RELEASE VALVES

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

Heavy welded steel outlet half. 3/4-inch NPT test plug. Benefits

Series 240 Pneumatic Control Valves Type and Type Three-way Valve Type 3244

OWS OPERATIONS & MAINTENANCE

Massachusetts Water Resources Authority

Crispin Valves Operating Guide. Crispin

VRX Plunger. Advanced Control Valve

Worldwide Contacts.

Sludge Accumulation Rate Determination and Comparison for Nursery, Sow and Finisher Lagoons

CONTROL VALVES QUALITY, DEPENDABILITY, SERVICE. REPUTATION BUILT ON. Innovative Solutions

THE CENTRAL MARIN SANITATION AGENCY TREATMENT PLANT INITIAL ANALYSIS OF CO THICKENING PRIMARY AND SECONDARY SOLIDS

Series 769 FireLock NXT Deluge Valve

Current Trends in Digester Mixing Technologies Becky Daugherty Brian Hemphill

PNEUMATIC ON OFF GLOBE VALVE

GENESYS 2x3x6 DESIGN AND FEATURES

EASY TO OPERATE. EASY TO CLEAN. EASY TO MAINTAIN.

SECTION MISCELLANEOUS VALVES

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

Spiral Scraper Clarifier

FILTERS, STRAINERS AND VALVES PRODUCT GUIDE

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

Iron Check Valves Illustrated Index

Series 8500 Grayline Butterfly Valves

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

INTRODUCTION BODY SUB-ASSEMBLY (FIGURE 1) 2 G X L GLOBE CONTROL VALVE VALTEK SULAMERICANA. Top entry assembly: quick and easy maintenance

Temperature Regulators

PDC Elastomer Lined Series 27 Butterfly Valve 2" thru 36" for 125/150 lb. Flanging

GW MKIII DELUGE VALVE - ALUBRONZE EXTERNAL RESET, PNEUMATIC

CHECKtronic Pump Control Valve

BF Series Wafer/Lug Butterfly Valves

Factors to consider when selecting a diverter valve

Model 2VP TM. Belt Filter Press Industry Leader in Design and Manufacture of Filtration Equipment

SECTION H3 TRAYMASTER SERIES DEAERATORS

Transcription:

ONYX VALVE CO The Pinch Valve Authority David David Gardellin, P.E. P.E. President President

A DISCUSSION OF CORROSION PROBLEMS INCURRED AT THE BONNYBROOK WASTEWATER TREATMENT PLANT By ARNY VANWIEREN, P.Eng. Mechanical Engineer Wastewater and Drainage City of Calgary

The Bonnybrook Wastewater Treatment Plant has experienced problems with new materials in its piping. The BNR process has increased the corrosive nature of various wastewater streams. The level of struvite developing throughout the plant in the sludge processes has created large maintenance problems. The intent of this paper is to discuss some of the problems that our Plant has incurred and to show how the Plant developed a strategy to mitigate those problems.

The Bonnybrook Wastewater Treatment Plant has a nominal design capacity of 550,000 cubic meters per day. The Bonnybrook drainage area occupies approximately 435 square kilometers and represents about 65 percent of the city area.

The secondary sludge created a problem beginning in the anaerobic digesters. Since Bio 'P' bacteria release phosphorus under anaerobic conditions, secondary sludge fed to the digesters releases phosphorus into the Shepard lagoons. The phosphorus reacts with ammonia and magnesium in the digested sludge to form struvite. (The source of the magnesium is Calgary's hard water.) The majority of the struvite settles in the Shepard lagoons to be utilized as slow releasing fertilizer in the digested sludge. Unfortunately not all the phosphorus is removed and some is recycled back to the plant along with other ionic compounds. Although struvite is a nuisance, it is essential for the removal of phosphorous.

Concentrations of the ions NH 4 +, P0 4 3-, and Mg 2 + found in the effluent results in the deposition of the crystalline mineral struvite, NH 4 MgP0 4 throughout effluent and sludge lines.

Struvite Struvite, which looks like cement, blocks pipes, pumps, valves, and nozzles. Struvite build-up occurs frequently where there is turbulent flow. Previously hydrated aluminum sulfate, a flocculent chemical, works effectively to bind the phosphorous without compromising the plant piping but is expensive.

Although struvite is not corrosive, it has a large impact on process piping degradation due to lost capacity. The Shepherd pump house was rebuilt approximately five years ago, utilizing PVC piping. Within two years heavy struvite buildups were seen on the piping. In addition the PVC piping did not last very long because surge pressures caused the line to fail catastrophically a number of times.

The piping was replaced with glass lined ductile iron pipe and fittings three years ago, and has proven very successful. The pipe was examined in October and it was observed that there was no struvite buildup inside the piping.

The plug valves were also a problem. We observed that struvite tended to build up on the nickel seat. Consequently, the struvite would tear the Buna rubber on the plug, eventually making the valve inoperable in a short time period. Typical Struvite in Plug Valve

Boston Harbor WWTP at Deer Island encounters struvite problems on sludge systems. Magnesium originates in the salt air environment.

Onyx series DAC Onyx model DAC: Full Round Full Port dual pinch on Center Line. Maintenance free actuator. Stem and rods stainless steel.

Onyx series DEC Electric Actuated Pinch Valves Full Round Dual Pinch Configuration Sizes from 1/2 to 30 On / Off or Modulating Service. Stainless steel stem and rods.

Onyx Valves and Pressure Sensors Work on Waste Water

Model DEC Throttles Raw Waste Water Model DEC diverts raw waste water from Burlington Twp to Burlington City during periods of peak load. Range = 100 to 1000 gpm, with flow accurate to 5 gpm.

The valves at the Shepherd pump house have been switched from motorized plug valves to motorized pinch valves because: 1. Valve closes to center, preventing debris build up around the stem as it typically does with the plug valves. 2. There is no tearing action created by the rotating Buna-N coated plug on the struvite built up on the valve seat.

The valves at the Shepherd pump house have been switched from motorized plug valves to motorized pinch valves because: 3. The valve operator is less likely to be jammed causing the electric operator to fail early. 4. Movement of the rubber sleeve causes crystalline struvite to break up.

The valves at the Shepherd pump house have been switched from motorized plug valves to motorized pinch valves because: 5. Valve can digest rocks, iron scrap, rags, from the Shepard dump station.

The valves at the Shepherd pump house have been switched from motorized plug valves to motorized pinch valves because: 6. The fully enclosed rubber sleeve by the iron body allows the valve to handle high surge pressures.

Boston Harbor WWTP at Deer Island encounters struvite problems on sludge systems. Magnesium originates in the salt air environment.

Onyx DHC pinch valves effectively control sludge feed to digesters at 500 ft head pressure.

Watson Marlow Peristaltic hose pump feeds sludge into egg shaped digesters.

Onyx model DAC at Back River WWTP in Baltimore MD. 6 DAC with Fail Closed Pneumatic actuator Controlling Raw Activated Sludge and Waste Activated Sludge.

Onyx Valve Co. Compression Molded Sleeves Superior dimensional control. Wall thickness +/- 0.005 Superior bond strength between rubber and fabric. Method of choice for all modern tires. Less labor intensive so replacement sleeves cost less.

Series GSF, GSD and GSS Shell & Tube type Pinch Valves Available with flanged connections Available with slip-on connection (no threads or grooves). Available with integrally mounted solenoid valve and pressure regulator.

Throttling service Why size pinch valves? Longer sleeve life More accurate flow control Why are pinch valves better in throttling service than other valves? Change system capacity with a simple sleeve change. No need to replace entire valve and actuator as with ball, butterfly, globe, plug style valves. Pneumatically Operated pinch valve w/ Fisher Positioner.