Accord DS/DM Series UltraSwitch Switch box

Similar documents
Accord DS/DM Series UltraSwitch Switch box

Automax DS/DM Series UltraSwitch Switch box

PMV WS/WM Series UltraSwitch

Accord WS/WM Series UltraSwitch

PMV WS/WM Series UltraSwitch

USER INSTRUCTIONS. Automax WS/WM Ultraswitch Switchbox. Installation Operation Maintenance FCD AXENIM /16

Installation Operation Maintenance

Installation Operation Maintenance

Product Specification

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

Product Specification

USER INSTRUCTIONS. PMV PS/PM Ultraswitch Switchbox. Installation Operation Maintenance FCD PMENIM /13

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

USER INSTRUCTIONS. Accord PS/PM Ultraswitch Switchbox. Installation Operation Maintenance FCD ACENIM /14

Product Specification

Valve Position Monitors

flowserve.com Limitorque LRP Limitorque Rack & Pinion Pneumatic Actuator

CRANE Limit Switches. CCR Series. CXA Series. CCA Series

Valve Position Monitors

Logix 3800 Digital Positioner

Installation Operation Maintenance

USER INSTRUCTIONS. Automax XCL/XML UltraSwitch. Installation Operation Maintenance. Switchbox. Experience In Motion FCD AXENIM A4-09/16

TECHNICAL BULLETIN. NAF Trunnball DL Ball Valves. Experience in Motion FCD NFENTB A4 09/14

Kämmer Series Low Flow Valves

Logix 3800 Digital Positioner

Vogt Valves The Connection Bulletin for Y Pattern Globe & Check Valves Class 1690 & Class 2680 CB 18

Kämmer Series Low Flow Valve

TECHNICAL BULLETIN. NAF Setball SF Ball Sector Valves. Experience In Motion. flowserve.com. NAF Setball FCD NFENTB A4 02/16

Kämmer Series Split Body Valves

APS & APIS ATEX AIRPOWER SWITCH BOXES FEATURES DESCRIPTION

PMV. P5 Pneumatic Positioner. Product Information

TECHNICAL BULLETIN. NAF Duball DL Ball Valves. Experience in Motion FCD NFENTB A4 12/14

Sensor boxes SRBE Key features and product range overview

MARPAC K SERIES. Full Bore Fire Safe Flanged Ball Valves

Quartz. Save Space with Low Profile Design

Vogt Valves The Connection Bulletin for Forged Steel Globe Valves for Water-Free Chlorine Service Class 300, 600 & 800 CB 07

General purpose / hazardous area

WORCESTER CONTROLS F519/529/819/829. Full Bore Fire Safe Flanged Ball Valves

NAF Duball DL Pocket Ball Valves TECHNICAL BULLETIN FCD NFENTB A4 11/17

D30 Compact Digital Positioner

CONTROLS INC. Position Indicators. Valve Positioners

Solenoid Block Kit for Series 90 Modular Accessory System Installation, Operation and Maintenance Instructions

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

Worcester Controls Directional Ball Valves

ACCUTRAK ROTARY POSITION MONITORS FLAMEPROOF - ATEX/IEC

Explosionproof NEC. Fully integrated and encapsulated rotary valve position monitors that are certified for use in explosive atmospheres.

Kämmer Multi-Z Severe Service Valves

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

Limit Switch Type 4747

Desuperheater FCD VLENTB /11. Experience In Motion

Product cataloge 2017

Installation Operation Maintenance

LIMIT SWITCH BOX MODEL - APL

Integrated Control modules

Edward. Equiwedge Forged Gate Valvee. Experience In Motion

Mounting: The following instructions apply to rotary actuators only. Linear applications require special mounting and coupling (consult factory).

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Limitorque Actuation Systems PT Series Worm Gear Operator

Integrated Control modules

Limitorque Actuation Systems B320 Series. Rugged and dependable bevel gear operators for manual or motorized valve control applications

TECHNICAL BULLETIN. Audco Ball Valve. Reduced Bore Fire safe Flanged Ball Valves 51/52 Series. Experience In Motion

S-17 CATALOG. Forged Steel Strainers

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

Valtek XL Series High Performance Positioner. for Control Valves

Worcester Controls Rotary Switches

flowserve.com Kämmer Multi-Z Kämmer Multi-Z Severe Service Valves

Limitorque Accutronic MX/WTR Performance and Dimensions. Limitorque Actuation Systems

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

brands you trust. CRANE - Automation Actuators and Instrumentation

INTERNATIONAL METAL ENGINEERING

Limitorque HBC Series Worm Gear Operators

ITS Series Position Monitoring Switch

Limitorque. HBC Series Worm gear operators proven in the most demanding situations

Contents. FieldQ. FieldQ. Product data sheet Rev. 0 October FieldQ Valve Actuator 2. FieldQ Actuator Torque 4

SERIES 5A AND 5B VALVE STATUS MONITOR THE HIGH PERFORMANCE COMPANY BRAY SERIES 70 ELECTRIC ACTUATORS

Tri-Pac E325 / E525 Ball Valve Three-Piece Bolted Body, In-Line Maintainable, Regular and Full Port. McCANNA/MARPAC Valves RO400-R4

LSB Series Position Monitoring Switch

Know-how makes the difference. Limit Switches

INTERNATIONAL METAL ENGINEERING

Rotary Valve Maxflo + 60 and 80 Opening type NT

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

flowserve.com Durco PlugSeal Valve ASME Class 600 Plug Valves Serving the Worldwide Desalination Industry Experience In Motion

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /13

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

E818/828 Series Fugitive Emissions 150# and 300# Flanged 2" - 8" Two-Piece Ball Valves Installation, Operation and Maintenance Instructions

Mark 100. Technical Bulletin F C D F C A T B

USER INSTRUCTIONS. Limitorque TM V Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 02/15

McCANNA Actuation Systems B

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

AccuTrak Rotary Position Monitors

Plug Valve Solutions for the Upstream Exploration and Production Pipelines Production manifolds, test manifolds and other dirty services

Experience In Motion. Flowserve Control Valve Products North American Quick Response Centers

Installation Instructions

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Valtek Beta Positioner. Valtek Beta Positioners. for Control Valves

Installation Instructions

Transcription:

Accord DS/DM Series UltraSwitch Switch box

Features DS/DM Series Ultraswitch Description The DS/DM Series UltraSwich from Flowserve Accord provides cost efficient, accurate and reliable position signaling for hazardous locations. The sturdy enclosure is offered in aluminum or corrosion resistant stainless steel and is provided with multiple switch options. An external indicator is available. The DS/DM is designed to be directly and easily mounted onto actuators for both rotary and linear indication. It may also be used as a junction box for direct connection of solenoid valves. Minimum two open terminals are always provided. Its compact housing has multiple mounting possibilities, up to three conduit entries and pre-wired switches to enable easy installation. It is designed to meet IP66 and NEMA Type 4X standards and is offered for general purpose/weather proof and for explosion proof hazardous locations. Features and Benefits Tool-free Quick-Set cams SIL 2 ATEX Ex d IIC T4 IECEx Ex d IIC T4 ccsa Class I, Division 1/2, Groups B,C,D, T6 CSAus Class I, Division 1/2, Groups A,B,C,D, T6 ccsaus NI Class I. Division 2. Groups A, B, C, D Switches available in a wide range of options (See Technical Data page - switch options) Easily accessed pre-wired terminal strip Minimum two open terminals are provided Housing of aluminum or corrosion resistant stainless steel Temperature range -55 C to +85 C -67 F to +180 F Optional 4-20mA feedback signal Conduit entries (2x) 3/4 NPT or (2x) M25x1.5mm (third entry optional) 2

Hazardous Locations Approvals Typical applications / industries suitable for the DS/DM-Series UltraSwitch are: Chemical Oil & Gas Pharmaceutical Offshore Hazardous locations approvals and communication Explosion proof: Approvals for: ATEX Ex d IIC T4 IECEx Ex d IIC T4 ccsa Class I, Division 1/2, Groups B,C,D, T6 CSAus Class I, Division 1/2, Groups A,B,C,D, T6 ccsaus NI Class I. Division 2. Groups A, B, C, D AS-Interface (AS-i) The DS/DM-series can be equipped with optional AS-i communication capabilities. This technology offers a very simple, flexible and cost efficient network system. Mounting options and visual indication NAMUR mounting kit with Indicator NAMUR mounting Standard NAMUR EN15714 mounting kits are available for standard NAMUR shafts. Available for 80x30 and 130x30 actuator top patterns with an actuator shaft height of 20, 30 or 50 mm. For linear applications the optional L shaft can be ordered. Visual indicator also shown. Mounting kit NAMUR p/n 23648 23649 23650 B C A = Bolt pattern length (mm) 80 80 130 A B = Bracket height (mm) 45 55 55 30 mm C = Height (mm) 145 155 155 3

Housing Aluminum or Stainless Steel housing Powder Epoxy painted Aluminum housing Base always black. Covers in black (standard), white or optional cover color on request Corrosion free Stainless Steel housing Unpainted stainless steel DIN 1.4408 4

Technical Data Switch Options Data/Materials Code Switch Option Manufacturer Load Capacity M1 SPDT Mechanical Honeywell MicroSwitch 15A @ 125/250 VAC; 0,5A @ 125 VDC; 0,25A @ 250VDC; 5A @ 120VAC MG SPDT Gold Mechanical Honeywell MicroSwitch 1A @ 125 VAC; 50 ma @ 24 VDC MC SPDT Mechanical Honeywell MicroSwitch Mechanical switch 250 F F3 IF5250 IFM 10-36VDC NC PNP, 150mA, 3-wire NC F5 IF6001 IFM 18-32VDC, NO PNP, 150mA@50 C F6 IF6034 IFM 10-36VDC, NO PNP, 150mA, Stainless Steel F7 IN0074 IFM 20-250 AC/DC NO, 350mA/100mA F8 IN0081 IFM 20-250 AC/DC NO, 350mA/100mA w/led P4 SPST Proximity Aleph 0.35A @ 140 VAC; 0.25A @ 200VDC (50 W Max.) P5 SPDT Proximity Hamlin 0.25A @ 120 VAC; 0.25A @ 28 VDC (3 W Max.) PE SPDT Sabre Proximity Flowserve 1A @ 120 VAC; 1A @ 24 VDC PP SPDT Phazer Proximity Flowserve 3A @ 120 VAC; 2A @ 24 VDC PT SPST BRS Proximity Flowserve 3A @ 120 VAC; 0.5 @ 24 VDC N3 Slotted NAMUR PF SJ3.5-S1N NAMUR NO 2-wire Safety function N8 Solid State Proximity PF NJ2 V3 N NAMUR NC Sensor; 8 VDC N9 Solid State Proximity PF NBB3-V3-Z4 NPN Sourcing; 100 ma max. Current; 5-60 VDC NP Solid State Proximity PF SJ3.5-N NAMUR Sensor Output; 5-25 VDC Supply NQ Solid State Proximity PF NJ4-12GK-N NAMUR NC Sensor; 8 VDC NR Solid State Proximity PF NJ4-12GM40-E1 PNP Sinking; 200 ma max. Current; 10-60 VDC NS Solid State Proximity PF NJ4-12GM40-E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC NT Solid State Proximity PF NJ4-12GK40-E2 NPN Sourcing; 200 ma max. Current; 10-60 VDC NW Solid State Proximity PF SJ3.5-SN NAMUR NC Sensor; 8 VDC Data Ingress protection IEC 529 IP 66 Weight 1.8kg / 4 lbs Aluminum housing Weight Stainless Steel housing Part Housings & Covers Shaft Cams/Splines Terminal Block Internal Brackets All External Fasteners All Internal Fasteners Indicator Label Certificate ATEX IECEx 3.5kg / 7.75 lbs Material Powder epoxy painted Aluminum or Stainless Steel Stainless Steel Nylon Nylon Nylon, Aluminum or Stainless Steel Stainless Steel Stainless Steel Polyurethane Polyester or Stainless Steel II 2GD Ex d IIC T4 Gb Ex tb IIIC T113 C Db Ex d IIC T4 Gb Ex tb IIIC T113 C Db ccsa Class I, Division 1/2, Groups B,C,D, T6 CSAus Class I, Division 1/2, Groups A,B,C,D, T6 ccsaus NI Class I. Division 2. Groups A, B, C, D More switch options available 5

DS/DM-Series Ultraswitch Switch box Nomenclature A = B = C = D = E = F = G = H = I = J = K = L = M = Product & Connections (cable entry) DS Explosion proof / Flame proof switch box with 3/4 NPT cable entries DM Explosion proof / Flame proof switch box with M25x1,5 cable entries Number of open cable entries 2 2 x open cable entries (standard) 3 3 x open cable entries (option) Housing material /Surface treatment B Aluminum housing, polyester powdercoating, Black base & cover W Aluminum housing, polyester powdercoating, Black base & White cover C Aluminum housing, polyester powdercoating, Black base & Optional cover color S Stainless Steel housing Shaft D Double D Shaft 1/4 N Namur VDI/VDE 3845 Shaft (rotary actuators) T For NAF Turnex actuators L D style including nut for linear applications Indicator option 0 No indicator 1 Indicator below switch box Qty of switches 0 0 Switches 2 2 Switches 4 4 Switches Switch options - see page with switch options Certificate 14 General Purpose 18 ccsa Class I, Division 1/2, Groups B,C,D; Class II, Division 1/2, Groups E, F, G; Class III CSAus Class I, Division 1/2, Groups A,B,C,D; Class II, Division 1/2, Groups E, F, G; Class III; 19 ATEX II 2GD, Ex d IIC T4 Gb, Ex tb IIIC 25 IECEx Ex d IIC T4 Gb, Ex tb IIIC 28 ccsaus NI Class I. Division 2. Groups A, B, C, D. Product approval marking 0 Self-adhesive marking label, Polyester M Stainless steel marking plate Analog Output 0 None 4 4-20mA transmitter (G= none, M1 or MG only) Terminal Options 2 2 Extra open terminals (Standard) 4 4 Extra open terminals (Optional, not possible for all switch options) 6 6 Extra open terminals (Optional, not possible for all switch options) 8 8 Extra open terminals (Optional, not possible for all switch options) H Heavy Duty Terminal Block, 8 contact points. Options/ Elastomers 0 Nitrile O-rings V Viton O-rings Brand A Accord Ordering code example A B C D E F G H I J K L M DS 2 B N 1 2 MG - 14-0 0 2 0 A 6 Explosion proof / Flame proof switch box with 3/4 NPT cable entries, 2 Cable entries, Aluminum housing, NAMUR shaft, Indicator, 2 switches MG, General purpose, label, No output, 2 Extra terminals, Nitrile O-rings, Worcester Brand

Dimensions DS/DM (mm/inch) M6(4X) Ø 125 (4.213) 35,4 (1.394) 57,2 (2.252) 3/4-14 NPT OR M25x1.5 (1-3x) 149 (5.866) 4 (.157) 93 (3.740) 99,3 (3.090) 15(.590) Ø56 (2.203) 137,5 (5.413) 57,2 (2.252) 35,4 (1.394) 21(.827) 5/16-18 UNC(4X) Clearance=145 (5.701) 7

Flowserve Corporation Flow Control Division 1978 Foreman Drive Cookeville, Tennessee 38501 USA Phone: +931 432 4021 Fax: +931 432 5518 flowserve.com FCD ACENBR0136-02-A4-07/15 To find your local Flowserve representative: For more information about Flowserve Corporation, visit flowserve.com Hazardous Locations ATEX II 2GD Ex d IIC T4 Gb Ex tb IIIC T113 C Db IECEx Ex d IIC T4 Gb Ex tb IIIC T113 C Db ATEX Ex d IIC T4 IECEx Ex d IIC T4 ccsa Class I, Division 1/2, Groups B,C,D, T6 CSAus Class I, Division 1/2, Groups A,B,C,D, T6 ccsaus NI Class I. Division 2. Groups A, B, C, D Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware thatflowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide generalguidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume theultimateresponsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation and Maintenance (I & M) instructions included with the product, and train its employees and contractors in the safe useof Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2015 Flowserve Corporation, Irving, Texas, USA. Flowserve and PMV are registered trademarks of Flowserve Corporation.