INSTALLATION INSTRUCTIONS FOR Owner's Copy FILTERED AND REGULATED POWER SUPPLY VOLTS DC INPUT: Hz.

Similar documents
50 AMP TRANSFER RELAY DELAY - DUAL INPUT GENSET

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

Installation Instructions

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

Installation Instructions

60 Series Engine Controls

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

RP-4000 Reserve Power Control

PBA Series Prelube Controls

AL600ULX Series. Power Supply/Charger Installation Guide

poollux Power plx-pw60 & plx-pw100

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

AccuPower AQU128B Installation Instructions

PS24/AC Volt AC 16 Amp

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

E.S.P. Embedded Sensing Probes for Motor Brushes

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

Table of Contents 文管中心 發行章

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Application Engineering

2. AC SERVICE AND MOTOR REQUIRED 1. ENCLOSURE REQUIRED

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

SmartBoost 50 INSTALLATION INSTRUCTIONS & OWNER S MANUAL LT93 SMTBST50 1. Issue 1 Print 2 AUTOMATIC SHORELINE TRANSFORMER

5300 Series Installation Guidelines

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

Installation Instructions & Users Manual

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

AccuPower AQU126B Installation Instructions

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Section R General Processing Unit Model GPU Operators Manual

CALTRAP INSTALLATION AND OPERATIONS MANUAL

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

Sentinel Field Satellite Controller

GV-10 Manual 10.5A / 140W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controllers with Maximum Power Point Tracking

FLOAT BATTERY CHARGER

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

ANZI Transfer Switch and Generator Wiring Installation Addendum

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

ELECTRICAL SYSTEM RP-7

Phoenix Inverter

POWERLINE 2000 Energy Management System TM

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Florham Park, NJ USA Call (ASCO) for sales or service

DIESEL Engine Fire Pump Controllers Features

SECTION MOTOR CONTROL

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Application Engineering

CONTROL FEATURES AVAILABLE OPTIONS

SMP3CTX Series Power Supply/Charger

Installation and Operation Guide. Tundra HD 2500 Power Inverter. for the. Webasto BlueCool Truck System

Series BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1

User Manual. Solar Charge Controller 3KW

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

The Power of Reliability INSTRUCTION MANUAL

GVB-8 (Boost) Manual

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

User s Manual. Automatic Switch-Mode Battery Charger

LP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999

SAVE THESE INSTRUCTIONS

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS

MODEL ELC-12/40-CVM-D BATTERY CHARGER

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

Instruction & Owner s Manual

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

OutdoorXUPS-600AHV-8364

WF-5110R True Sine Wave Inverter

Dycon D2430 EN54-4 Fire Alarm Power Supply Series


Florham Park, NJ USA Call (ASCO) for sales or service

2904 Power Supply Installation Instructions I-EA00041

OWNER S MANUAL POWER INVERTER

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

30A SMART ENERGY MANAGEMENT SYSTEM TM

Cruising Charger Series OWNER S MANUAL

1000 Watt Pure Sine Wave Power Inverter, Users Manual

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

MODEL 422 Submersible Pump Controller

WF-5110R True Sine Wave Inverter

Transcription:

103158 March 9, 2011 FOR INDOOR USE ONLY Detex Corporation, 302 Detex Drive, New Braunfels, Texas 78130-3045 (830)629-2900 / 1-800-729-3839 / Fax (830)620-6711 E-MAIL: detex@detex.com INTERNET: www.detex.com INSTALLATION INSTRUCTIONS FOR 90-800 Owner's Copy 90-800 FILTERED AND REGULATED POWER SUPPLY 1.0 AMP @ 24 VOLTS DC INPUT: 120 VAC @.65A MAX @ 60 Hz. CAUTION: De-energize unit before servicing. ATTENTION : éteindre l'unité avant l'entretien. Enclosure provides protection against electric shock and fire. Do not open without removing power. Only trained personnel should operate or service this equipment. Le couvercle protège contre les chocs électriques et incendies. Ne pas lòuvrir sans préalablement couper l àlimentation. Seul le personnel formé doit opérer ou effectuer l éntretien de cet équipement. Page 1

DETEX Model 90-800 Filtered Regulated Power Supply Connection Diagram and Instructions The 90-800 is a regulated and filtered power supply. It has an output voltage of 24 volts DC. Refer to the drawing of the power supply (Figure 1) for connections and adjustments. All connections and adjustment should be made with the power supply de-energized AND main power switch (item 3) in the OFF position. Wiring between the fire control panel and fire loop input to this power supply must be configured for fail safe operation. This unit is intended to operate with door hardware devices. Refer to device instructions for additional details on connections and grounding requirements. Use minimum 18 ga copper conductor (from building power) AC INPUT 120VAC.650 AMPS MAX 60 HZ F2 RATED 1.5A@250V SLOW BLOW DETEX P/N 104239-1 RECOMMENDED WIRE SIZES: Figure 1. WIRE GAUGE MAXIMUM LENGTH OF TWO CONDUCTOR CABLE 20 AWG 10 FEET 18 AWG 40 FEET Page 2

1: Main Power Connection (J5). Observe correct terminal connections. Color code requires connections be made per NFPA72. Leave circuit de-energized while installing and servicing unit. Maximum tightening torque: 7 in-lbs (.79 Nm) White Black Green/Yellow NEUTRAL HOT GND J5 AC IN from building power 2: Fire Loop Control (J2). The fire loop control requires a connection be made between the Sense and Ret terminals. Some locking devices require this terminal be connected to the building fire system. For independent operation a jumper wire may be used to make the connection. When the connection is made, the power supply outputs 24 volts at J3 and J4. LED 2 will also light when the circuit connection is made (See Item 7). If the circuit is open, the output relay is de-energized and the output of the power supply is turned off. The fire loop terminal is polarity sensitive and has an adjustable sense voltage (See Item 8). The Ret is connected to the circuit board ground. Note: Each power supply should have an independent fire alarm relay. Maximum tightening torque: 5.3 in-lbs (.6 Nm) 3: Main ON-OFF Switch (S1). This switch can be used to de-energize the power supply for service and adjustments. High voltage is still present inside the enclosure (including T1 Item 10) as long as the main power at J5 is still energized. Caution should be used when performing service even when this switch is used. Ret J2 S1 4: Main Power Fuse (F2). This is a slow blow fuse and protects the main power into the power supply PWA and transformer. If the fuse fails, check and correct the cause of the overload before replacing with GMT 1.5A fuse. 5: Output Terminals (J3, J4). The power supply outputs 24 volts at a maximum of 1 amp total current. The output is protected by a thermally resetable fuse (F1, Item 9). The output is DC, and the PWA is marked with dual polarity indicators. Maximum tightening torque: 5.3 in-lbs (.6 Nm) J3 J4 F2 POS NEG 2 + 4 - D C (+) to load (-) Page 3

6: Power Output Good (LED 3). The LED will glow red when the PWA is operating normally and J3 and J4 are energized. LED 1 7: Fire Loop Active (LED 2). The LED will glow red when the Fire Control output terminal is connected correctly. LED 2 8: Fire Loop Voltage Select (S2). This switch selects the sense voltage of the fire loop circuit. It is set at the factory to 24, resulting in a sense voltage of 24 volts. For systems requiring 12 volt sensing, slide the switch to the 12 position. 24 ON S2 12 9: 24 Volt DC Thermal Fuse (F1). This fuse protects the output of the PWA from overloading. It requires no adjustment and will return to proper operation once the cause of the overload is found and corrected. F1 10: Class 2 50 V/A Transformer (T1). This transformer is supplied by Detex and is rated for proper operation with this power supply. Replace with Detex part number 104254. T1 J1 11: 24 Volt AC input (J1) from transformer secondary. This input is connected at the factory. Maximum tightening torque: 5.3 in-lbs (.6 Nm) 24 AC IN 12: Fused high voltage to transformer primary. This input is connected at the factory. This terminal block has at least 120 VAC live when the AC input at J5 is energized. Maximum tightening torque: 5.3 in-lbs (.6 Nm) To XMFR J6 Page 4

13: LED System Indicator on Front Cover. This Led glows green when the unit is energized, S1 is 'ON' and the PWA inputs are working normally. 14. AC Input Rating: This is the required AC power input to this power supply. AC INPUT 120VAC.650 AMPS MAX 60 HZ 15. Fuse Rating: Only replace fuse with the type rating specified by this label. F2 RATED 1.5A@250V SLOW BLOW DETEX P/N 104267-2 Page 5

90-800 Testing and Trouble Shooting 1. The green LED on the cover indicates High Voltage is being supplied to the power supply board. If there is no light check F2, replace with same rating and type if blown. Check the load and wiring for proper operation if fuse blows again. Also check incoming power source for disconnect or fault. Make sure S1 is set to 'on'. 2. LED 2 indicates the status of the fire loop connection. This connection must be closed for proper operation. If LED 2 does not light, check the following: a) J2 terminal connection to the building fire system. An Isolation Relay is recommended. b) If an isolation Relay is not used, try reversing the wires on the J2 terminal block. Some building fire systems are polarity sensitive. c) Check S2 for proper fire loop sense voltage. S2 is set to 'ON' at the factory for 24 volt DC sense voltage. Set S2 to 'OFF' for 12 volt sense systems. d) If code does not require this connection, a jumper wire may be placed across the terminals of J2. 3. When the board is powered, LED 3 will light, indicating the 24 volts DC output is active. If LED 3 is not on, first make sure LED's 1 and 2 are both on, following the listed steps above. If they are both on but LED 3 is off, check for a shorted load or wiring to the load. Remove the load from the J3 (and J4) terminal(s), wait 15-30 seconds and see if LED 3 comes on. If so, the load or associated wiring has a short. Correct these faults before reconnecting the power supply. 4. Low line voltage: Low input voltage may effect output voltage. 5. Shorted load: A shorted load will cause the output voltage and current to turn off. Locate and correct cause of fault. 6. Enclosure provides protection against electric shock and fire. Do not open without removing power. Disconnect installed at facilities. 7. Only trained personnel should operate or service this equipment. 8. WARNING: When replacing F2 fuse, use ONLY a fuse of the same rating and type. 90-800 Maintenance and Spare Parts 1. Replacement Fuse: Detex number 104267-2 2. Replacement transformer: Detex number 104254 3. Replacement circuit board: Detex number PWA 104252 Page 6

Single Page Quick Reference:. Use minimum 18 ga copper conductor (from building power) AC INPUT 120VAC.650 AMPS MAX 60 HZ F2 RATED 1.5A@250V SLOW BLOW DETEX P/N 104239-1 Figure 2 Use minimum 20 ga copper conductor. Observe proper polarity. 1. AC input. 2. Building fire loop connection. 3. Main On/OFF switch. 4. AC input fuse. See label for rating & type. 5. 24 VDC output connections (x2). 6. DC output active indicator. 7. Fire Loop/Panel connection active. 8. Fire loop sense voltage select. 24 VDC or 12 VDC. 9. PTC resetable output protection fuse. 10. Class 2 transformer. Contact Detex for replacement if needed. 11. 24 VAC input from transformer. 12. Fuse protected AC input to transformer. 13. Power good indicator on front panel of Power Supply. 14. AC input power requirements. 15. Fuse rating Page 7

INSTALLATION 90-800 1. Place box on vertical wall surface - intended use on drywall or concrete block wall. Total top to bottom space required is 10" (255mm). Mark and attach with four #10 screws and #10 nylon conical anchors, minimum length of 1-7/16" for drywall, or equivalent masonry anchors for concrete block wall. 2. Attach conduit and couplings making sure there is still sufficient clearance around the controller board. 3. Connect 120VAC power to Power Supply positions 1, 2 & 3. Insure ground is connected prior to switching power on. Circuit should have breaker or fuse protection equal to 15 ampere. Minimum wire size to be 18 gauge using a minimum torque of 7 in-lbs on the screws. Mounting holes AC INPUT 120VAC.650 AMPS MAX 60 HZ F2 RATED 1.5A@250V SLOW BLOW DETEX P/N 104239-1 10" 10" Mounting holes Page 8