IMPROVED BOTTOM LINE & PV ASSET MANAGEMENT

Similar documents
IMPROVED BOTTOM LINE & PV ASSET MANAGEMENT. SolarEdge Commercial Offering for Installers & EPCs

Improved Bottom Line. SolarEdge Commercial Offering. for Installers & EPCs

IMPROVED BOTTOM LINE & PV ASSET MANAGEMENT

3 Phase Power Systems - Designed for Canada

POWER OPTIMIZERS. SolarEdge Power Optimizer. Module Embedded Solution OPJ300-LV. PV power optimization at the module-level.

SOLAREDGE S STOREDGE SOLUTION

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Sunny Tripower CORE1.

SolarEdge Single Phase StorEdge Inverter for Europe, APAC & South Africa

SolarEdge. Distributed Solar Power Harvesting Systems. Company Presentation SolarEdge

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Segen offer the SE2200, SE3000, SE3500, SE3680, SE4000, SE5000 and SE6000 single-phase inverters at great value prices.

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

SolarEdge. Distributed Solar Power Harvesting Systems. Company Introduction SolarEdge

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

SMA COMMERCIAL PRODUCTS SUNNY TRIPOWER CORE1. Stands on its own. Up to 60 % faster installation for commercial PV systems

MAKING PV SYSTEMS SMARTER. SolarEdge Residential Offering for Installers

The StorEdge Solution

A flexible and efficient residential solar solution. Conext RL single-phase grid-tie inverter

Your home and business energy independance. Energy Bundle CA5000TPV-3D

SolarEdge System Overview

MAKING SOLAR SYSTEMS SMARTER

MAY 2018 Improving CAPEX and OPEX of PV power plants with high power string inverters Gianluca Pieralli (Regional Sales Manager Lat Am) / Gianluca

The StorEdge Solution. Enabling Energy Independence

MAKING PV SYSTEMS SMARTER

Maximize your ROI. Conext CL-60 String Inverter. The ideal solution for decentralized power plants and commercial rooftops

MAKING SOLAR SYSTEMS SMARTER

SolarEdge. Distributed Solar Power Harvesting Systems SolarEdge

POWER OPTIMIZIER. (+34) Skype

SUNNY TRIPOWER CORE1 60% UP TO. faster installation for commercial PV systems. Subline lorem ipsum dolor sit amet EN DE STANDS ON ITS OWN

There s a new power in Solar 1500V ultra-high power string inverters for utility-scale PV applications

ABB central inverters PVS to 1000 kw

MAKING PV SYSTEMS SMARTER

RE10 tenksolar System Overview

ABB central inverters PVS to 1000 kw

SolarEdge Solution - Making PV Panels Smarter GGS. Greener Gas Scotland Renewables & Heating

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

Schneider Electric PV Skid. Optimized solar power conversion system tailored to enhance any North American PV power plant

Trinasmart SEUK Oct Daniel E. Mamat Product Management

Power Conversion System The Best Technology for your photovoltaic and storage system

Pre-announcement. Transformerless Solar Inverters

The microinverter The latest in solar technology

SPEEDFAX TM 2011 Renewable Energy Products Contents

Microgrid solutions Delivering resilient power anywhere at any time

MAKING PV SYSTEMS SMARTER

MAKING PV SYSTEMS SMARTER

OPTIMIZING COMMERCIAL SOLAR

MAKING PV SYSTEMS SMARTER

SolarMax MT A series A reliable solution for commercial PV applications

MAX310 BEESMART SOLAR MICRO INVERTER 260 COMMUNICATION GATEWAY Apparent Power Control (APC)

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

StorEdge Solar and Energy Storage System Review

SAMPLE PERMIT APPLICATION PACKAGE

ABB central inverters ULTRA-750/1100/ kW to 1560kW

X-SERIES SOLAR PANELS

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

ABB central inverters PVS to 2000 kva

Catch Eco Range : Technical Specification Sheet

PLUG-AND-PLAY ENERGY STORAGE SOLUTION

ABB central inverters PVS to 2091 kva

Retrofit to Single phase / Three phase PV system Micro-grid, UPS, Peak shift, Pure off-grid retrofitting etc multi-working

Greater reliability and flexibility for large solar installations. Conext Core XC-NA series central inverters

ABB micro inverter system MICRO-0.25/0.3/0.3HV-I-OUTD 0.25kW to 0.3kW

Enphase M215 PRODUCTIVE SIMPLE RELIABLE. Enphase Microinverters

Sunny Tripower. Can do everything that we can

SolarMax P series The power package for residential solar plants

TerraSAS High-Performance 600V PV simulator

The intelligent, reliable cloud-connected inverter for utility-scale renewable power

Re-defining the utility-scale inverter

MAKING SOLAR SYSTEMS SMARTER PANEL TO GRID SOLUTIONS FROM A GLOBAL LEADER IN SOLAR TECHNOLOGY

Module-Integrated Power Electronics for Solar Photovoltaics. Robert Pilawa-Podgurski Power Affiliates Program 33rd Annual Review Friday, May 4th 2012

Creating technology to keep the sky blue... MAVI SOLAR PHOTOVOLTAIC ENERGY STORAGE SYSTEM

OUR PARTNERS. More: Please note: All product illustrations in this brochure may differ from the original.

MAX310 BEESMART SOLAR MICRO INVERTER TYPE 260. Apparent Power Control (APC) SOLAR PV MODULES UP TO 310 W peak

SolarMax MT series. The power pack for maximum yields.

Micro-Inverter. Corporate and Product Presentation. AEconversion GmbH & Co. KG. Micro vs. String. Product Details. USPs. Market Overview.


FusionSolar Smart PV Solution. Exceed your profit targets through Digitalization Networking Higher Yields. FusionSolar

SolarMax MT series The all-rounder for trade and industry

SolarMax 50TS/80TS/100TS/300TS. Ready for the future.

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

Green Inverters from. Solar inverters. for Asia. Solar inverters. for Europe. Solar inverters. for America. Solar inverters.

HYBRID POWER FOR TELECOM SITES

Get More When Shopping for Solar

MORNINGSTAR PRODUCT TRAINING

Pika Energy Island Made in America

ABB string inverters PVI-3.8/4.6-I-OUTD 3.8 to 4.6 kw

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

ABB string inverters PVI-3.0/3.6/4.2-TL-OUTD 3 to 4.2 kw

SOL-ARK 8K We guarantee it s the most effcient & affordable Multi-Mode Inverter in its class

off-grid Solutions Security of supply Basics: Off-grid energy supply

SOL-ARK 8K. More Affordable: 5-15% less solar panels & 5-20% less batteries than others! World s Most Efficient Battery Inverter

AC MODULE P72PCS-300W

Commercial 1000VDC String Inverter XGI Installation and Operation Guide Models: XGI XGI

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

Features MICRO-0.25-I MICRO-0.3-I PRODUCTS PANEL

INSTALLATION MANUAL CRYSTALLINE SOLAR MODULES

The sun as power station

40 Módulos FV TRINA SOLAR 265Wp Policristalino (Estructura Incluida) 1 Inversor KACO Blueplanet 10,0 TL3

Transcription:

IMPROVED BOTTOM LINE & PV ASSET MANAGEMENT SolarEdge Commercial Offering for Installers & EPCs

Content 04 SolarEdge Fact Sheet 06 Moving Forward to DC Optimized Inverters 08 PV Asset Management with Module-Level Monitoring 14 Maximum Energy Yield in Commercial Installations 16 Future Compatibility & Warranty 18 A Higher Lifetime Value 20 Commercial System Diagram 22 300kWp Rooftop System Comparison 24 300kWp Electrical Diagram Comparison 26 1MWp Ground Mount System Comparison 28 1MWp Electrical Diagram Comparison 30 Product Datasheets 30 SE15K-33.3K Three Phase Inverter 32 SE55K-82.8K Three Phase Inverter 34 SE66.6K-100K Three Phase Inverter for the Medium Voltage Grid 36 P600-P800 Power Optimizer 38 SolarEdge Control & Communication Gateway 40 Environmental Sensors 42 Analog Sensor Connections 1.63MW SolarEdge system, The Netherlands Installed by AliusEnergy 44 Comprehensive Service Suite 2 SolarEdge Commercial Offering www.solaredge.com 3

SolarEdge Fact Sheet About Us In 2006, SolarEdge invented an intelligent inverter solution that has changed the way power is harvested and managed in PV systems. SolarEdge provides module-level electronics for solar power harvesting and monitoring for residential, commercial, and utility-scale solar PV installations. The SolarEdge DC optimized inverter system maximizes power generation at the PV module level while lowering the cost of energy produced by the solar PV system. Vision > As a leading provider of intelligent inverter solutions for the PV industry, our vision is to enable every solar module to be individually managed by DC-DC module-level electronics > Our goal is to accelerate the pace toward grid parity and make clean, renewable solar energy affordable and widespread Bankability > SolarEdge has been audited and approved by major banks and financial institutions for projects and funds worldwide > Publicly traded on the NASDAQ under the SEDG symbol Global Outreach > Systems installed in 120 countries > Sales via leading integrators and distributors > Follow the sun call centers > Local teams of sales, service, marketing, and training experts > Global manufacturing with tier 1 electronic manufacturing service companies Power Optimizers Shipped (Cumulative) > Received nearly 30 awards, from prestigious organizations ranging from Red Herring to Frost & Sullivan Business Figures > 20,600,000 power optimizers and 856,000 inverters shipped worldwide > Monitoring platform continuously tracks over 490,000 PV installations Units Shipped (M) 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 2012 2013 2014 2015 2016 Q1/2017 Q2/2017 Q3/2017 Corporate Social Responsibility > As a global leader in renewable energy solutions, SolarEdge is deeply committed to promoting a greener world > SolarEdge is in full compliance with international standards on quality and control, ethical conduct and environmental protection 111 awarded patents and 149 additional patent applications Product Reliability > Long product warranties: 25-year power optimizer warranty and 12-year inverter warranty, extendable to 20 or 25 years > SolarEdge products and components undergo rigorous testing, and have been evaluated in accelerated life chambers > Reliability strategy includes proprietary application specific ICs (ASIC) (Calendar Years) 4 SolarEdge Commercial Offering www.solaredge.com 5

Moving Forward to DC Optimized Inverters Significance of Inverter Selection Inverter selection is key for the lifetime planning and performance of commercial PV systems. While inverters may only account for ~10% of the system cost, they: 1. Influence ~30% of system cost (EBoS, inverter, labor) 2. Manage 100% of system production 3. Control O&M expenses by enabling PV asset management Reduced BoS Costs Up to 15kW per string allows for more modules per string. This leads to fewer strings per inverter and therefore less wiring, combiner boxes, and fuses. This reduces BoS costs by up to 50%. Traditional Inverter SolarEdge DC Optimized Inverter Lifetime Revenue More Modules With module-level power optimization and maximum design flexibility, more modules can be installed on the roof, enabling a shorter project payback period. Standard inverter 149.5 kw DC SolarEdge 200 kw DC 34% added power More Energy The module-level MPPT eliminates losses to maximize power from each individual module, offering more energy production from the PV system. This technology future proofs the system against potential risks that could cause decreased lifetime energy production. System Lifetime O&M Costs Future Compatibility & Warranty Low-cost inverter replacement (~40% less than traditional inverters), long inverter warranty, free lifetime monitoring, and the ability to install different module power classes/brands in the same string, decrease future costs. Cost-Saving Maintenance & Higher System Uptime Free module-level performance monitoring & remote maintenance for system lifetime lead to more effective and efficient O&M by decreasing trips to sites, reducing the amount of time spent on site, and increasing system uptime. 1MW SolarEdge system, Hoffenheim, Germany Installed by Wircon Enhanced Safety The DC disconnect is designed to automatically drop DC voltage, as well as current from all DC string cables, whenever inverter or grid power is shut down. The voltage of each module is reduced to 1V. SolarEdge inverters comply with the UL1699B arc detection standard designed to mitigate the effects of some arc faults that may pose a risk of fire. 6 SolarEdge Commercial Offering www.solaredge.com 7

PV Asset Management with Module-Level Monitoring As a strategic O&M tool for optimum plant operation and PV asset management, the SolarEdge cloud-based monitoring platform increases system uptime. As equipment prices drop and system sizes trend upward, PV projects are increasingly seen as secure long-term investment opportunities. Like any financial asset, PV systems must be monitored and managed to realize their full potential. Traditional inverters offer limited information, such as string-level or system-level monitoring that can indicate underperformance of the array, but little else. It then becomes costly and time consuming to send skilled technicians to perform on site troubleshooting on inverters operating under load and on DC lines at nearly 1000V. They must connect expensive equipment to the arrays in an effort to sift through the tea leaves of complex IV trace curves to detect issues. SolarEdge Saving 15%-25% Overhead Monitoring & Reporting The SolarEdge DC optimized inverter solution offers advanced PV monitoring and asset management through its cloud-based monitoring platform. Power optimizers constantly track MPP and report high-resolution data on module performance. O&M Cost 1MW SolarEdge system, Florida, United States Developed and installed by Region Solar & Sol Integrators The SolarEdge monitoring platform transforms O&M from a manual, resource-intensive process to an automated, at-a-glance service. The solution delivers module-level insights and ensures that a plant is performing to the best of its ability at all times. Corrective Maintenance * Exclusive of module cleaning Preventive Maintenance 8 SolarEdge Commercial Offering www.solaredge.com 9

PV Asset Management with Module-Level Monitoring (cont.) SolarEdge's Monitoring Platform Features: 1. Real-time remote monitoring at the module, string, and system levels 3. Pinpointed and automatic alerts for immediate fault detection, accurate maintenance, and rapid response. The alerts show the specific fault location, fault description, and fault status. Energy threshold alerts can be set to detect underperforming modules. Custom settings available for time of day and offset from sunrise and sunset. The logical layout displays the electrical connectivity between modules, strings and inverter The hierarchy layout displays grouping of components per inverter 2. Comprehensive analytics tracking and reports of energy yield, system uptime, performance ratio, and financial performance 4. The time-of-use feature allows system owners to define peak and off-peak rates in order to track expected PV revenue. This may be used as an indication of the systems ROI. Dashboard - Energy production is displayed with weekly, monthly and yearly resolution Performance Ratio - Analyze and track the system's performance ratio 10 SolarEdge Commercial Offering www.solaredge.com 11

PV Asset Management with Module-Level Monitoring (cont.) 5. Accurate and remote troubleshooting for fast and efficient resolution with minimal and shortened onsite visits. Examples of identifying underperforming modules: Bypass Diode Failure Soiling Before cleaning After cleaning It is easy to identify the bypass diode failure with the module-level voltage graphs. The faulty module outputs at only 2/3 of the voltage (5/6 in this case of power optimizer connected to two modules). 6. The consumption monitoring feature shows data about electricity consumption, PV production, and self-consumption. This feature is integrated into all SolarEdge inverters and requires only a connection of a SolarEdge Modbus Meter. Potential Induced Degradation (PID) Looking at the modules within one string, it is possible to see the power degradation increasing towards the negative pole. No need to send technicians to the roof module voltage is measured remotely 12 SolarEdge Commercial Offering www.solaredge.com 13

Maximum Energy Yield in Commercial Installations Unavoidable in commercial installations, module-level mismatch occurs when modules in a string have different Maximum Power Points (MPPs). Arising from a variety of sources, the mismatch decreases the energy yield of the entire string. Impp Traditional String Inverter 247W 250W 242W 248W Impp Impp Impp Impp SolarEdge DC Optimized Inverter Solution 247W 250W 242W 248W Impp Impp Impp Examples of power mismatch in commercial installations: Manufacturing Tolerance Mismatch The module manufacturer-warranted output power range may vary greatly. A standard deviation of 3% is sufficient to result in ~2% energy loss. Guaranteed power output from module manufacturers 0~+3% Vmpp Vmpp Vmpp Vmpp Vmpp Vmpp Vmpp Vmpp Soiling & Shading Module soiling, from dirt, bird droppings or snow, contributes to mismatch between modules and strings. (Figure 1) While there may be no obstructions during site installation, throughout a system s lifetime, a tree may grow or a structure may be erected that creates uneven shading. (Figure 2) > MPPT per string - all modules operate at same current, regardless of their individual MPP > Weak modules reduce the performance of all modules in the string or are bypassed > Power losses due to module mismatch > MPPT per module - current & voltage adjusted per module > Maximum power produced and tracked from each module individually > 2%-10% more energy from the PV system The SolarEdge DC optimized inverter solution mitigates power losses caused by module mismatch for maximum power generation from each module. With SolarEdge, strong modules are not affected by the weaker ones. Figure 1 - Soiling mismatch Figure 2 - Partial shading Uneven Module Aging Module performance can degrade up to 20% over 20 years, however, each module ages at a different rate, which causes aging mismatch. Worst module Average Best module Batch Source: A. Skoczek et. al., The results of performance measurements of field-aged c-si photovoltaic modules, Prog. Photovolt: Res. Appl. 2009; 17:227 240 14 SolarEdge Commercial Offering www.solaredge.com 15

Future Compatibility & Warranty As part of PV asset management planning, it is important to account for future costs that can impact the return on investment of a PV system. The SolarEdge DC optimized inverter solution effectively minimizes these potential costs. Forward compatibility eliminates expensive stock of spare module inventory. > Replacement: SolarEdge allows modules of different power classes and brands in the same string. > Expansion: New power optimizers can be utilized in the same string with older models. SolarEdge offers 25-year power optimizer warranty, 12-year inverter warranty, and free monitoring for 25 years. SolarEdge offers extended warranties at attractive prices. Power Optimizers 600W - 800W Commercial Inverters 15kVA - 100kVA Cloud-based Monitoring Platform SolarEdge provides low-cost inverter replacement out of warranty > ~40% less than traditional inverters Products are certified for ammonia resistance - suitable for agricultural areas AMMONIA RESISTANT 2.02MW SolarEdge system, Denmark 16 SolarEdge Commercial Offering www.solaredge.com 17

A Higher Lifetime Value The SolarEdge DC optimized inverter solution offers a better LCOE for a system s lifetime by maximizing yield and reducing costs. The SolarEdge DC optimized inverter solution maximizes power generation at the individual module level, which leads to a higher lifetime revenue from PV systems. While the initial cost of the SolarEdge solution is generally slightly higher than the equivalent traditional inverter system, the total installation cost as well as the lifetime maintenance cost, is lower. This makes the SolarEdge solution more economically attractive. Lifetime PV System Cost and Revenue $ Lifetime revenue BoS cost Inverter replacement cost Lifetime O&M cost System lifetime Value Traditional inverter SolarEdge solution 1.3MW SolarEdge system, Arizona, USA 18 SolarEdge Commercial Offering www.solaredge.com 19

Commercial System Diagram The SolarEdge solution consists of inverters, power optimizers, and a cloud-based monitoring platform. The technology provides superior power harvesting and module management by connecting power optimizers at the module level. The ability to connect two modules to one optimizer, combined with DC to AC conversion and grid interaction being centralized at a simplified PV inverter maintains a competitive cost structure. Cloud-based Monitoring Platform Full visibility of system performance Remote troubleshooting Access via browser or any Android, ios smart phone or tablet Communication with the power optimizers over existing DC power lines (PLC) Control & Communication Gateway Connection of multiple environmental sensors to analyze system performance P600 P800 2-to-1 Power Optimizer Configuration 15kVA 100kVA Inverter Environmental Sensors Module-level MPPT - no mismatch power losses Strings of uneven lengths, modules on multiple azimuths & tilts Compatible with SolarEdge inverters SE15K & larger SafeDC - automatic module-level safety shutdown Lower cost compared to traditional inverters Superior efficiency Small, lightweight, easy to install Built-in communication hardware Optional integrated DC Safety Unit Embedded export limitation Connection of environmental sensors to calculate site performance ratio and measure environmental conditions 20 SolarEdge Commercial Offering www.solaredge.com 21

300kW Rooftop System Comparison Comparison of a 300kWp SolarEdge system to an identical system with a traditional string inverter The system, in Amsterdam, The Netherlands, comprises 1,000 300Wp modules. One system was designed with 3 x SE82.8K SolarEdge inverters and 500 P700 power optimizers in a 2:1 configuration. The second system was designed with 9 27.6kW traditional string inverters. SolarEdge Large Capacity Inverters The 82.8K inverter is part of SolarEdge's extended offering of commercial solar inverters, providing large capacity with reduced installation time and cost. The inverter is based on three small and lightweight units; one primary unit easily connected to two secondary units. Up to 31 inverters can be configured directly from one master inverter for fast commissioning. Energy Comparison PVsyst was used to simulate the yield of both systems in year 1 and year 20. The SolarEdge advantage is growing with time due to uneven module aging which increases mismatch between modules. Traditional String Inverter SolarEdge System SolarEdge Advantage PVsyst year 1 yield (MWh) 272.3 279.1 2.5% PVsyst year 20 yield (MWh) 242.9 257.2 5.9% BoS comparison Traditional String Inverter SolarEdge DC Optimized Inverter DC power (kw) 300 300 AC power (kw) 248.4 248.4 Modules (300W, 72-cell) 1,000 1,000 Inverters 9 3 No. of strings 54 27 Modules per string 18/19 36/38 DC cable CU 1 6mm 2 (m) 6,227 2,195 AC cable N2XY 4 x 16mm 2 54 - AC cable N2XY 4 x 35mm 2-18 MC4 connectors (1 pair) 108 54 Datalogger 1 - BoS cost 100% 33% BoS cost saving* * Estimated saving on BoS components based on typical market prices in Cabling Comparison 1.19 c/w Traditional Inverter Cabling Diagram Total of 54 strings SolarEdge Cabling Diagram Total of 27 strings Included DC cables Additional DC cables 22 SolarEdge Commercial Offering www.solaredge.com 23

300kWp Rooftop System Electrical Diagram Comparison Traditional String Inverter System SolarEdge DC Optimized Inverter Solution AC Combiner Box AC Combiner Box 24 SolarEdge Commercial Offering www.solaredge.com 25

1MWp Ground Mount System Comparison Comparison of a 1MWp SolarEdge solution to an identical system with a traditional string inverter The system, in Munich, Germany, comprises 4,050 260Wp modules. One system was designed with 11 SE82.8K SolarEdge inverters and 2,025 P600 power optimizers in a 2:1 configuration. The second system was designed with 18 50kW traditional string inverters. SolarEdge Large Capacity Inverters The 82.8K inverter is part of SolarEdge's extended offering of commercial solar inverters, providing large capacity with reduced installation time and cost. The inverter is based on three small and lightweight units; one primary unit easily connected to two secondary units. Up to 31 inverters can be configured directly from one master inverter for fast commissioning. Energy Comparison PVsyst was used to simulate the yield of both systems in year 1 and year 20. The SolarEdge advantage is growing with time due to uneven module aging which increases mismatch between modules. Traditional String Inverter SolarEdge System SolarEdge Advantage PVsyst year 1 yield (MWh) 1,159 1,182 2% PVsyst year 20 yield (MWh) 1,036 1,090 5.2% BoS comparison Cabling Comparison Traditional String Inverter SolarEdge DC Optimized Inverter DC power (kw) 1,053 1,053 AC power (kw) 900 910.8 Modules (300W, 72-cell) 4,050 4,050 Inverters 18 11 No. of strings 180 99 Modules per string 22/23 40/42 DC cable CU 1 6mm 2 (m) 7,347 5,244 MC4 connectors (1 pair) 360 198 AC cable NA2XY 4 95mm 2 (m) - 747 AC cable NA2XY 4 70mm 2 (m) 1,349 - Datalogger 1 - BoS cost 100% 62% BoS cost saving* * Estimated saving on BoS components based on typical market prices in 0.4 c/w Traditional Inverter Cabling Diagram Total of 180 strings SolarEdge Cabling Diagram Total of 99 strings Included DC cables Additional DC cables 26 SolarEdge Commercial Offering www.solaredge.com 27

1MWp Ground Mount System Electrical Diagram Comparison Traditional String Inverter System SolarEdge DC Optimized Inverter Solution AC Combiner Box AC Combiner Box 28 SolarEdge Commercial Offering www.solaredge.com 29

SE15K-33.3K Three Phase Inverter Datasheet Specifically designed to work with power optimizers Superior efficiency (98%) Small, lightest in its class, and easy to install Built-in LAN internet connection IP65 Outdoor and indoor installation Fixed voltage inverter Optional integrated DC Safety Unit - 2-pole Mechanical DC disconnect - DC surge protection (type II) - DC fuses SE15K SE16K SE17K SE25K SE27.6K SE33.3K* OUTPUT Rated AC Power Output 15000 16000 17000 25000 27600 33300 VA Maximum AC Power Output 15000 16000 17000 25000 27600 33300 VA AC Output Voltage - Line to Line / Line to Neutral 380 / 220 ; 400 / 230 480 / 277 Vac (Nominal) AC Output Voltage - Line to Neutral Range 184-264.5 244-305 Vac AC Frequency 50/60 ± 5 Hz Maximum Continuous Output Current (per Phase) 23 25.5 26 38 40 A Residual Current Detector / Residual Current Step Detector 300 / 30 ma Grids Supported - Three Phase 3 / N / PE (WYE with Neutral) V Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds Yes SE15K SE16K SE17K SE25K SE27.6K SE33.3K INPUT Maximum DC Power (Module STC) 20250 21600 22950 33750 37250 45000 W Transformer-less, Ungrounded Yes Maximum Input Voltage 900 1000 Vdc Nominal DC Input Voltage 750 840 Vdc Maximum Input Current 22 23 23 37 40 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 700kΩ Sensitivity 350kΩ Sensitivity (1) Maximum Inverter Efficiency 98 98.3 98.1 % European Weighted Efficiency 97.6 97.7 97.7 98 98 98 % Nighttime Power Consumption < 2.5 < 4 W ADDITIONAL FEATURES Supported Communication Interfaces (2) RS485, Ethernet, Zigbee (optional), Wi-Fi (optional), Built-in GSM (optional) DC SAFETY UNIT (OPTIONAL) 2-pole Disconnection N/A 1000V / 40A DC Surge Protection N/A Type II, field replaceable DC Fuses on Plus & Minus N/A Optional, 20A Compliance N/A UTE-C15-712-1 STANDARD COMPLIANCE Safety IEC-62103 (EN50178), IEC-62109, AS3100 VDE-AR-N-4105, G59/3, AS-4777,EN 50438, CEI-021,VDE 0126-1-1, CEI-016 Grid Connection Standards (4), (3) BDEW Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 RoHS Yes INSTALLATION SPECIFICATIONS AC Output Cable Gland - diameter 15-21 Cable Gland - diameter 18-25 mm DC Input 2 MC4 pairs 3 MC4 pairs DC Input with Safety Unit N/A Gland outer diameter 5-10 mm Wire cross section 0.5-13.5 mm 2 Dimensions (HxWxD) 540 x 315 x 260 mm Dimensions with Safety Unit (HxWxD) N/A 775 x 315 x 260 mm Weight 33.2 45 kg Weight with Safety Unit N/A 48 kg Operating Temperature Range -20 to +60 (M40 version -40 to +60) C Cooling Fan (user replaceable) Noise < 50 < 55 dba Protection Rating IP65 - Outdoor and Indoor Bracket Mounted (Bracket Provided) (1) Where permitted by local regulations (2) Refer to Datasheets -> Communications category in Downloads page for specifications of optional communication options: http://www.solaredge.com/groups/support/downloads (3) For all standards refer to Certifications category in Downloads page: http://www.solaredge.com/groups/support/downloads (4) Models SE25K and SE27.6K only * 33.3k requires separate 480V-MV transformer 30 SolarEdge Commercial Offering www.solaredge.com 31

SE55K-82.8K Three Phase Inverter Datasheet Specifically designed to work with power optimizers Easy two-person installation Superior efficiency (98.3%) Lower BoS and labor costs compared to using multiple smaller string inverters Higher uptime and easy serviceability Built-in module-level monitoring with Ethernet or cellular GSM Wall/rail mounted, or horizontally mounted under the modules from a 10 tilt Fixed voltage inverter Integrated DC Safety Unit with DC Safety Switch Optional DC surge protection (Type II) Optional DC fuses Mobile configuration of up to 3.2MW in one go Simple, simultaneous configuration of an additional 31 inverters from a single master inverter Configure all relevant inverter settings including pairing and firmware updates Save valuable time with easy and fast commissioning Mobile inverter activation & configuration SE55K SE82.8K OUTPUT Rated AC Power Output 55000 82800 VA Maximum AC Power Output 55000 82800 VA AC Output Voltage - Line to Line / Line to Neutral (Nominal) 380 / 220 ; 400 / 230 Vac AC Output Voltage - Line to Line Range; Line to Neutral Range 318-460; 184-264.5 Vac AC Frequency 50/60 ± 5 Hz Maximum Continuous Output Current (per Phase) @Vac,nom 80 120 A Grids Supported - Three Phase 3 / N / PE (WYE with Neutral) V Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Yes Thresholds INPUT Maximum DC Power (Module STC) 74250 111780 W Transformer-less, Ungrounded Yes Maximum Input Voltage 1000 Vdc Nominal DC Input Voltage 750 Vdc Maximum Input Current 80 120 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 350kΩ Sensitivity per Unit (1) Maximum Inverter Efficiency 98.3 % European Weighted Efficiency 98 % Nighttime Power Consumption < 12 W ADDITIONAL FEATURES Supported Communication Interfaces (2) RS485, Ethernet, Cellular GSM (optional) DC SAFETY UNIT DC Disconnect 1000V / 2 x 40A 1000V / 3 x 40A DC Surge Protection Optional, type II, field replaceable DC Fuses on Plus & Minus Optional, 30A STANDARD COMPLIANCE (3) Safety IEC-62109, AS3100 Grid Connection Standards (4) VDE-AR-N-4105, G59/3, AS-4777,EN 50438, CEI-021,VDE 0126-1-1, CEI-016, BDEW Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 RoHS Yes INSTALLATION SPECIFICATIONS Number of units 2 3 AC Output Cable Cable gland - diameter 22-32; PE gland diameter Cable gland - diameter 20-38; PE gland diameter 10-16 10-16 mm DC Input (5) 6 strings, 4-10mm 2 DC wire, gland outer diameter 5-10mm ter 5-10mm 9 strings, 4-10mm 2 DC wire, gland outer diame- AC Output Wire Up to 50, Aluminum or Copper Up to 95, Aluminum or Copper mm 2 Dimensions (HxWxD) Primary Unit: 940 x 315 x 260; Secondary Unit: 540 x 315 x 260 mm Weight Primary Unit: 48; Secondary Unit: 45 kg Operating Temperature Range -20 - +60 (6) (M40 version -40 - +60) C Cooling Fan (user replaceable) Noise < 60 dba Protection Rating IP65 - Outdoor and Indoor Bracket Mounted (Brackets Provided) (1) Where permitted by local regulations (2) Refer to Datasheets -> Communications category in Downloads page for specifications of optional communication options: http://www.solaredge.com/groups/support/downloads (3) Pending (4) For all standards refer to Certifications category in Downloads page: http://www.solaredge.com/groups/support/downloads (5) Single input option per unit (up to 25mm 32 SolarEdge Commercial Offering 2 ) available (6) De-rating from 50 C www.solaredge.com 33

SE66.6K-100K Three Phase Inverter Datasheet for the Medium Voltage Grid Specifically designed to work with power optimizers Easy two-person installation Superior efficiency (98.1%) Lower BoS and labor costs compared to using multiple smaller string inverters Higher uptime and easy serviceability Built-in module-level monitoring with Ethernet or cellular GSM Wall/rail mounted, or horizontally mounted under the modules from a 10 tilt Fixed voltage inverter Integrated DC Safety Unit with DC Safety Switch Optional DC surge protection (Type II) Optional DC fuses Mobile configuration of up to 3.2MW in one go Simple, simultaneous configuration of an additional 31 inverters from a single master inverter Configure all relevant inverter settings including pairing and firmware updates Save valuable time with easy and fast commissioning Mobile inverter activation & configuration SE66.6K SE100K OUTPUT Rated AC Power Output 66600 100000 VA Maximum AC Power Output 66600 100000 VA AC Output Voltage - Line to Line / Line to Neutral (Nominal) 480 / 277 Vac AC Output Voltage - Line to Line Range; Line to Neutral Range 432-528 / 249.3-304.7 Vac AC Frequency 50/60 ± 5 Hz Maximum Continuous Output Current (per Phase) @277V 80 120 A Grids Supported - Three Phase 3 / N / PE (WYE with Neutral) V Utility Monitoring, Islanding Protection, Configurable Power Factor, Country Configurable Thresholds Yes INPUT Maximum DC Power (Module STC) 90000 135000 W Transformer-less, Ungrounded Yes Maximum Input Voltage 1000 Vdc Nominal DC Input Voltage 850 Vdc Maximum Input Current 80 120 Adc Reverse-Polarity Protection Yes Ground-Fault Isolation Detection 350kΩ Sensitivity per Unit (1) Maximum Inverter Efficiency 98.1 % European Weighted Efficiency 98 % Nighttime Power Consumption < 12 W ADDITIONAL FEATURES Supported Communication Interfaces (2) RS485, Ethernet, Cellular GSM (optional) DC SAFETY UNIT DC Disconnect 1000V / 2 x 40A 1000V / 3 x 40A DC Surge Protection Optional, Type II, field replaceable DC Fuses on Plus & Minus Optional, 30A STANDARD COMPLIANCE (3) Safety IEC-62109, AS3100 Grid Connection Standards (4) VDE-AR-N-4105, G59/3, AS-4777,EN 50438, CEI-021,VDE 0126-1-1, CEI- 016, BDEW Emissions IEC61000-6-2, IEC61000-6-3, IEC61000-3-11, IEC61000-3-12 RoHS Yes INSTALLATION SPECIFICATIONS Number of units 2 3 AC Output Cable Cable gland - diameter 22-32; PE Cable gland - diameter 20-38; PE gland diameter 10-16 gland diameter 10-16 mm DC Input (5) 6 strings, 4-10mm 2 DC wire, gland 9 strings, 4-10mm 2 DC wire, gland outer diameter 5-10mm outer diameter 5-10mm AC Output Wire Up to 50, Aluminum or Copper Up to 95, Aluminum or Copper mm 2 Dimensions (HxWxD) Primary Unit: 940 x 315 x 260; Secondary Unit: 540 x 315 x 260 mm Weight Primary Unit: 48; Secondary Unit 45 kg Operating Temperature Range -20 - +60 (6) (M40 version -40 - +60) C Cooling Fan (user replaceable) Noise < 60 dba Protection Rating IP65 - Outdoor and Indoor Bracket Mounted (Brackets Provided) (1) Where permitted by local regulations (2) Refer to Datasheets -> Communications category in Downloads page for specifications of optional communication options: http://www.solaredge.com/groups/support/downloads (3) Pending (4) For all standards refer to Certifications category in Downloads page: http://www.solaredge.com/groups/support/downloads (5) Single input option per unit (up to 25mm 2 ) available (6) De-rating from 50 C 34 SolarEdge Commercial Offering www.solaredge.com 35

SolarEdge Power Optimizer P600-800 The most cost-effective solution for module-level optimization in commercial installations More energy Superior efficiency (99.5%) Balance of System costs reduction; 50% less cables, fuses and combiner boxes, over 2x longer string lengths possible Fast installation with a single bolt Next generation maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety Use with two PV modules connected in series or in parallel P600 (for 2 x 60-cell PV modules) P700 (for 2 x 72-cell PV modules) P800p (for parallel connection of 2x 96-cell 5 PV modules) P800s (for series connection of 2x high power or bifacial modules) INPUT Rated Input DC Power (1) 600 700 800 W Absolute Maximum Input Voltage (Voc at lowest 96 125 83 120 Vdc temperature) MPPT Operating Range 12.5-80 12.5-105 12.5-83 12.5-105 Vdc Maximum Short Circuit Current (Isc) 10.1 14 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.6 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 18 Adc Maximum Output Voltage 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc P600 (for 2 x 60-cell PV modules) P700 (for 2 x 72-cell PV modules) P800p (for parallel connection of 2x 96-cell 5 PV modules) STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety) RoHS Yes Fire Safety VDE-AR-E 2100-712:2013-05 INSTALLATION SPECIFICATIONS Compatible SolarEdge Inverters Three phase Three phase inverters inverters SE16K & larger SE15K & larger Maximum Allowed System Voltage (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. (2) For other connector types please contact SolarEdge. (3) For ambient temperature above +70 C / +158 F power de-rating is applied. Refer to Power Optimizers Temperature De-Rating Application Note for more details. (4) Single input version has 1.8m output wires. P800s (for series connection of 2x high power or bifacial modules) 1000 Vdc Dimensions (W x L x H) 128 x 152 x 43 / 128 x 152 x 50 / mm / 128 x 152 x 59 / 5 x 5.97 x 2.32 5 x 5.97 x 1.69 5 x 5.97 x 1.93 in Weight (including cables) 834 / 1.8 933 / 2.1 1019 / 2.2 1064/2.3 gr / lb Input Connector (2) MC4 MC4 (Single or Dual input) (6) MC4 Output Connector MC4 1.2 / 3.9 (portrait 1.2 / 3.9 (portrait 1.2 / 3.9 (portrait 1.2 / 3.9 (portrait Output Wire Length orientation) or orientation) or orientation) or orientation) or 1.8 / 5.9 2.1 / 6.9 1.8 / 5.9 2.1 / 6.9 m / ft (landscape orientation) (landscape orientation) (landscape orientation) (4) (landscape orientation) Operating Temperature Range (3) -40 - +85 / -40 - +185 C / F Protection Rating IP68 / NEMA6P Relative Humidity 0-100 % PV SYSTEM DESIGN USING A SOLAREDGE INVERTER (5)(6) THREE PHASE SE15K AND LARGER THREE PHASE SE16K AND LARGER THREE PHASE SE33.3K Compatible Power Optimizers P600 P600, P600, P800 P700 P700 P800 Minimum String Power Optimizers 13 12 13 Length PV Modules 26 24 26 Maximum String Power Optimizers 30 Length PV Modules 60 Maximum Power per String 11250 (7) 13500 12750 (8) 15300 W Parallel Strings of Different Lengths or Orientations Yes (5) P600 and P700 can be mixed in one string. It is not allowed to mix P600/P700/P800 with P300/P350/P500/P404/P405 in one string. (6) In a case of odd number of PV modules in one string it is allowed to install one P600/P700 /P800 power optimizer connected to one PV module. When connecting a single module to the P800p the single input version should be used. (7) For SE27.6K: It is allowed to install up to 13,500W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W; inverter max DC power: 37,250W. (8) For SE33.3K: It is allowed to install up to 15,000W per string when 3 strings are connected to the inverter and when the maximum power difference between the strings is up to 2,000W; inverter max DC power: 45,000W. 36 SolarEdge Commercial Offering www.solaredge.com 37

SolarEdge Control & Communication Gateway All-in-one communication gateway Environmental sensors support Power reduction interface & MV grid control Modbus meter reader Easy installation - DIN rail and wall mount SE1000-CCG-G POWER Power Supply - Wall Mount Included, 100-240VAC, EU/UK/US/AU interchangeable, 2-pin plug Supply Voltage 9-14 VDC Connector Type terminal block Power Consumption <2 W ANALOG SENSOR INPUT Number of Inputs 3 Range Accuracy Resolution Input 1 0-30mV or 0-2V Input 2 0-2V or 0-10V +/- 1% f.s 10 bit Input 3-20mA 20mA COMMUNICATION INTERFACES Ethernet Interface SE1000-CCG-G 10/100-BaseT Wireless Connections ZigBee module ( * ) Power Reduction Interface RS232 Interface SUPPORTED RS485 DEVICES (A) SolarEdge Devices Export Inverter Data Revenue Meters 4 control pins, 5V, GND For local connection Export Data to Non-SolarEdge Logger Yes ENVIRONMENTAL Operating Temperatures -20 to 60 C Protection Rating IP20 Indoor MECHANICAL Mounting Type DIN Rail / Wall mount Dimensions (L W H) 161.6 90 62 mm Weight 0.5 kg STANDARD COMPLIANCE Safety UL60950-1, IEC-60950-1 EMC FCC Part 15 class B, IEC61000-6-2, IEC61000-6-3 (a) for supported protocols and devices, see link: www.solaredge.com/files/pdfs/se-gateway-supported-devices (*) sold separately - see individual product specs for supported locations Yes Yes Yes 38 SolarEdge Commercial Offering www.solaredge.com 39

Environmental Sensors Environmental Monitoring of a SolarEdge System Connect environmental sensors to the SolarEdge Control and Communication Gateway Calculate site performance ratio Irradiance, temperature, and wind measurements Direct Irradiance Ambient Temperature Module Temperature Wind Velocity Units SE1000-SEN-IRR-S1 SE1000-SEN-TAMB-S2 SE1000-SEN-TMOD-S2 SE1000-SEN-WIND-S1 INSTALLATION SPECIFICATIONS Control and Communication Gateway (sold separately; SE1000- Needed CCG-G) Dimensions 154 x 86 x 40 / 64 x 58 x 34 / 64 x 58 x 34 / 165 x 105 x 105 / 6 x 3.5 x 1.5 2.5 x 2.3 x 1.3 2.5 x 2.3 x 1.3 6.5 x 4.2 x 4.2 mm / in Weight 340 / 0.75 350 / 0.77 350 / 0.77 750 / 1.65 gm / lb Enclosure type Powder-coated aluminum Pulver Coated Aluminium Pulver Coated Aluminium Housing - Aluminum (AlMgSi1) Cup star - Synthetic, with fibre glass (PC-GF10) Bottom - Synthetic (POM H2320) Operating Temperature -20 to 70 / -4 to 155-40 to 80 / -40 to 176-40 to 80 / -40 to 176 0 to 70 / 32 to 155 C / F Protection Rating IP65 IP67 IP67 IP55 The warranty and service for the sensors is provided directly by Ingenieurbüro Mencke & Tegtmeyer GmbH; for more details, please see http://www.imt-solar.com/products.html Direct Irradiance SE1000-SEN-IRR-S1 Ambient Temperature SE1000-SEN-TAMB-S2 Module Temperature SE1000-SEN-TMOD-S2 Wind Velocity SE1000-SEN-WIND-S1 OUTPUT Electrical output range 0-1.4V 0-10V 4-20mA 4-20mA MEASUREMENT -40 to 90 C / Range 0-1400 W/m 2-40 to 194 F ±5 W/sq.m ±2.5% of Accuracy measuring value -40 to 90 C / -40 to 194 F 1% of full scale 1% of full scale 0-50 m/s ±0.5 m/s or ±3% of measuring value Units 40 SolarEdge Commercial Offering www.solaredge.com 41

Analog Sensor Connections With the connection of sensors to the SolarEdge Control and Communication Gateway (CCG), PV system owners can monitor the site s irradiance, temperature and wind velocity. This also enables the SolarEdge monitoring server to calculate and display the site performance ratio (PR), calculated based on the sensor readings. 42 SolarEdge Commercial Offering www.solaredge.com 43

Comprehensive Service Suite SolarEdge supports you throughout your PV project life cycle. We provide the tools and services to help you grow your business with us. Project Design and Pre-Sale Our dedicated tools and engineering services help you close deals. Project design & Pre-Sale Tailor-made design optimization by SolarEdge pre-sale engineers Training and tools help your sales team convey the added value of the SolarEdge solution Project Execution LCOE and ROI analysis PV simulation and Comparative system analysis Operation & Maintenance 44 SolarEdge Commercial Offering www.solaredge.com 45

Comprehensive Service Suite (Cont.) Project Execution Operation & Maintenance Our advanced tools and features will assist you to easily and smoothly execute projects. Our advanced monitoring platform allows you to guarantee system availability and high performance ratio for system lifetime. Performance monitoring Project design validation prior to installation Hands-on installation training by local field engineers Installation validation checklist Fleet management Pre-scheduled performance and status reports of multiple sites Pinpointed automatic Inter-site and multi-site alerts comparisons Fault detection DC safety protecting installers from high DC voltage Easy and flexible string layout Satellite-based performance ratio Executive reporting Remote and on-site installation support by local service teams Inverter and module-level fault identification Remote troubleshooting tools Service Remote operations to commission and activate the installation Site specific automated production reports Automatic commissioning report Rapid RMA process 46 SolarEdge Commercial Offering Follow the sun call center www.solaredge.com 47

SolarEdge invented an intelligent inverter that has changed the way power is harvested and managed in PV systems. The SolarEdge DC optimized inverter maximizes power generation at the individual PV module-level while lowering the cost of energy produced by the PV system. Addressing a broad range of solar market segments, from residential to commercial and largescale solar, the SolarEdge DC optimized inverter solution includes PV inverters, power optimizers, and cloud-based monitoring. By connecting power optimizers to each module, the system enables superior power harvesting and module management. System costs remain competitive by centralizing the DC-AC inversion and grid interaction at a simplified PV inverter. Enhanced PV asset management including reduced O&M costs are enabled through module-level monitoring and remote troubleshooting. Another benefit is the automatic DC shutdown, for installer, maintenance personnel, and firefighter safety, through the SafeDC mechanism. Website Email Twitter Facebook www.solaredge.com info@solaredge.com www.twitter.com/solaredgepv www.facebook.com/solaredge SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 11/2017/V01/ENG ROW. Subject to change without notice. This document includes estimates of various parameters of the compared solar systems, including annual A/C energy production, performance ratio and shading loss based on PVsyst computer-simulated results for installations using our and competing systems. While we are not aware of any reason to believe these estimates and comparisons are materially inaccurate or misleading, they are inherently uncertain and the projected results are not guaranteed. Actual results will vary depending on a number of factors, including actual field conditions, quality of installment and other variances from the assumptions underlying the estimates. Although care has been taken to ensure the accuracy, completeness and reliability of the estimates and comparisons presented, SolarEdge assumes no responsibility for these. MORE SPECIFICALLY, IN NO EVENT SHALL SOLAREDGE BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL OR INCIDENTAL LOSSES OR DAMAGES RESULTING FROM OR ARISING OUT OF USE OF OR RELIANCE ON THE ESTIMATES AND COMPARISONS PRESENTED. Cautionary Note Regarding Market Data and Industry Forecasts: This brochure may contain market data and industry forecasts from certain third-party sources. This information is based on industry surveys and the preparer s expertise in the industry and there can be no assurance that any such market data is accurate or that any such industry forecasts will be achieved. Although we have not independently verified the accuracy of such market data and industry forecasts, we believe that the market data is reliable and that the industry forecasts are reasonable.