perma STAR VARIO Operators pocket guide

Similar documents
perma FLEX Quick Reference Pocket Guide

perma FUTURA Quick Reference Pocket Guide

Pressure chlorine changeover unit C 7520

IM012E (ELECTRONIC) POSITIVE DISPLACEMENT FLOWMETER INSTRUCTION MANUAL

If a single test is completed entirely, but indicated as "not OK", a DTC will be stored in DTC memory. Check DTC Memory Page

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

POSITIVE DISPLACEMENT FLOWMETER

Installation and Operating Instructions. Solar System Controller ISC3030

Domestic Water Supply Pressure Pumps

Installation and Operating Instructions. Solar System Controller ISC3020

User Manual Solar Charge Controller 3KW

Installation Instructions & Users Manual

Installation and Operating Instructions

Installation Guide perma STAR VARIO

Minerals. Warman Accumin Automatic Lubricators Overview

User Manual. Solar Charge Controller 3KW

Owners Manual. Features

LCD EWP /FAN DIGITAL CONTROLLER Installation Instructions

Installation Guide perma CLASSIC

Owners Manual. Features

Preventive Maintenance for Pail Melters

Der PARAVAN KALI V2 Cassette lift Owner`s Manual. User manual/ PARAVAN KALI V3.3 cassette lift (Software-Update 2.0)

Section 55 Chapter 6

CONTENTS. GENERAL PRESENTATION 2 SAFETY INSTRUCTIONS 2 Caution 2 Safety instructions 2

perma Automatic Lubrication Systems

CONGRATULATIONS ON YOUR PURCHASE OF YOUR THUNDER SOLAR REGULATOR!

FREEWAY RANGE OWNERS MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

Aftermarket Manual. Aftermarket Manual. Table Of Contents. Ground Control 3.0

Visit for more technical information & downloads

AP500 FAULT FINDING NEW INSTALLATION

Service Manual Model S800 Smart Stand

Electronic Crane Scale

TRITON ERROR CODES ERROR CODE MODEL SERIES DESCRIPTION RESOLUTION

STREAMLINER M 500 cc Instructions. User Operating Manual

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

TROUBLESHOOTING FOR IDEAL - SCHWAB PATERNOSTER Models: TPL - 2 HD & TPL - S

The Expert in Lubrication Solutions. perma Lubrication Systems for Electric Motors

Service Manual Model S400 and S500 Smart Stand

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 01

SI AT A22. English. Printed: Doc-Nr: PUB / / 000 / 03

Part No EWP & FAN DIGITAL CONTROLLER INSTRUCTIONS

June 25, 2013 # Model 464 Electronic Pump Control Unit User Guide

Installation Guide. The Expert in Lubrication Solutions

HTL perma Australia Pty Ltd

ESCO EQUIPMENT SUPPLY COMPANY FORKLIFT JACK. Instruction Manual. Forklift Jack

ELECTRONIC POSITIVE AIR SHUTOFF

QUICKSTART ESSENTIALS

CMS Electric Cylinder. Addendum to the Operating Instructions. Edition 11/ / EN

Service instructions. MAGNA Series 2000

HG 20F-012E-01 OIL CONTROL GUN

Third Generation NITE Phoenix

January 10, 2017 # Rev. B. Model 464 Mk3 Electronic Pump Control Unit User Guide

PANcharge1k Battery Charger User's Manual

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

To ensure proper installation, digital pictures with contact information to before startup.

OWNERS MANUAL GPS RENTAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

Rutland Remote Display -Model Installation and Operation

WelCOMe TO YOUR new VOlVO! VOLVO V50 QUICK GUIDE

Electronic Brake Control

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3. MAY FORM Section

B-RAD Select USER MANUAL TABLE OF CONTENTS

SDC 204. Microprocessor-controlled system control unit for solar thermal systems. Installation and Operating Instructions

CeraControl. Temperature Programmer User Handbook.

Installation and Operating Instructions

User manual MTS-32. QUI-1013 Version 1.5 January

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

KeContact P20. User manual

HTL perma Australia Pty Ltd

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors

OWNER S MANUAL RIDE-ON LAWNMOWER. SUPPLEMENT FOR M SERIES. Part N o :

Ground Control TT Leveling System OWNER'S MANUAL

Service Manual Model L1000 Smart Lift

Owner s and Maintenance Manual for: Lincoln QuickLub Systems

All specifications and figures are subject to change without notice. Printed in China Instruction Manual

How to use the NOx sensor emulator NOXEM Part 1

Operating instructions Flow monitor SI / / 2014

Mitsubishi. VFD Manuals

EQUALIZER SYSTEMS County Road 3 Elkhart, IN Fax

VOLUMETRIC BLENDING SYSTEM OPERATION MANUAL

AMB100L-im-issue INSTRUCTION MANUAL 240V DIESEL MINI BOWSER AMB100L AMB100L

Troubleshooting Manual

Fixed Right First Time. Volvo Technicians, Service and Parts Managers

Statim G4 Error Codes

Installation Instructions

4.2 Component Identification

Yaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C , SIEP C , and SIEP C

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

:43 1/13 Victron & BYD B-Box

Orica Seismic Electronic Initiation System OSEIS TESTER. Manual

Installation and Operating Instructions. Solar System Controller ISC1000

OPERATIONS MANUAL M-520. Please take the time to read these instructions before starting to use the scales. Page 1

GENERAL PRESENTATION 2 SAFETY INSTRUCTIONS 2 Caution 2 Safety instructions 2

SERVICE MANUAL. Chairman Robo PG8

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

Operating instruction and technical description

NOTICE. Installation of MAM 8** can be performed only by professional technician

Subject Underhood G System Error Codes and Symptoms System or Parts affected

Stop! Read this important information before proceeding any further.

OWNER S TECHNICAL MANUAL

Transcription:

perma STR VRIO Operators pocket guide

1 attery insert & assembly Insert battery set into the underside of the Drive. It will click into place. The drive will perform a self-test, during which the LED system will change from red to green to orange and the drive motor will run continuously. The perma STR VRIO is set and controlled via a simple to navigate menu using a single SET button. The menu is intuitive and requires minimal manipulation after the initial setting. Features which support simple operation and error minimisation include: CLICK! OK Initial set screen new lubricator displays on the LCD. This forces users to set the time and lubricant canister size before the lubricator can be turned on. utomatic restart When the lubricant canister and battery set is changed the lubricator automatically restarts meaning that there is no need to use the SET button when serving lubricators. 1 2 3 Sit the Drive on top of the lubricant canister so that the socket of the Drive engages correctly with the hexagonal head of the grease canister spindle. Secure it by rotating the collar until it comes to its stop point. OK When correctly assembled the white triangle markings around the Drive will be visible as shown.

+60 C 140 F -10 C +14 F - - 8 - J 2 III 1 K OFF The canister SIZE and TIME settings must be assigned for each new Drive before first use. LC S60 Insert a new battery set. The lubricator will perform a self-test and display >. L LC L250 perma STR VRIO Setting for the 1 st time J K L The lines at the bottom of the display indicate the SIZE options of 60, 120 or 250 cm 3. Press the SET button for 5 seconds and the lines will begin to flash. Release and press the button to scroll through the SIZE options. Stop at the desired size. C The TIME setting must now be assigned. fter SIZE has been assigned wait for the TIME setting to begin flashing. Press and release the button to scroll through the TIME options. Stop at the desired monthly setting. - - - - D OK Wait for the screen to go to the OFF status. OFF Press the SET button for 1 second to turn LC S60 the lubricator ON. LC L250 The setting will now be displayed and after 8 seconds the lubricator will perform its initialisation run cycle. > new Drive Unit which has not been set LC S60 - - t the end of the run cycle the display will return to the allocated setting. LC L250

3 Changing the setting 4 Turning OFF & ON fter initial programming the asigned settings can be changed at anytime from either the ON or OFF status. Press the SET button for 5 seconds. The line indicating the SIZE setting will begin flashing. Release and press the button to scroll to the new SIZE setting. LC S60 LC L250 Wait for the TIME setting to begin flashing. Push and release the SET button to scroll to the new TIME setting. When the new setting is assigned the Drive will return to its previous operational status. - - - - - - The lubricator can be turned OFF at anytime except during a run cycle. If a lubricator is turned OFF for a period of time it will retain memory of its operational status and recommence the lubricant delivery program from that point when turned back ON. It is important to note that turning the lubricator OFF and ON does not reset the memory of the grease volume remaining. The only way to reset the memory is to remove and re-insert the battery set. Press the SET button for 1 second to turn the Drive OFF. The OFF screen will be displayed. off +60 C 140 F -10 C +14 F Press the SET button for 1 second to restart the lubricator. The programmed setting will be shown. J K

5 Dispensing rate options Setting, months 1 2 3 4 5 6 7 8 9 10 11 12 Canister Size 250 cm 3 cm 3 per day 8.3 4.2 2.8 2.1 1.7 1.4 1.2 1.0 0.9 0.8 0.8 0.7 Canister Size 120 cm 3 cm 3 per day 4.0 2.0 1.3 1.0 0.8 0.7 0.6 0.5 0.4 0.4 0.4 0.3 Canister Size 60 cm 3 cm 3 per day 2.0 1.0 0.7 0.5 0.4 0.3 0.3 0.3 0.2 0.2 0.2 0.2 Time between cycles Hrs : Mins 1h : 30m 3h : 00m 4h : 36m 6h : 06m 7h : 36m 9h : 06m 10h : 36m 12h : 12m 13h : 42m 15h : 12m 16h : 42m 18h : 12m

6.1 Lubricator status Dwell 6.2 Lubricator status Run The display shows the time setting and the lubricator canister size. For the example shown the time setting is 3 months and the canister size is 250cm 3. Single GREEN flash every 7 seconds. ru stands for run and indicates that lubricant is being dispensed. t the end of the run cycle the lubricator will return to the dwell mode, displaying the time setting and canister size. Single GREEN flash every 1 second. The line indicates the canister size The digit shows the time setting The lubricator is in between lubricant delivery cycles. The time between cycles depends on the lubricator time setting. The drive system is dispensing lubricant.

6.3 Lubricator status Purge 6.4 Lubricator status Empty PU stands for purge and indicates that the purge cycle has been activated and that lubricant is being dispensed. Single GREEN flash every 1 second. The display shows LC. Double RED flash every 2 seconds. The purge cycle has been initiated by holding down the SET button for 10 seconds. full purge cycle delivers around 6cm 3 of grease and can be interrupted at anytime by pushing the SET button once. The lubricant canister (LC) is empty and needs to be changed. If LC is displayed but the canister is not empty check the following: 1. Check that the canister size setting correctly matches the actual canister size. 2. Ensure that batteries are exchanged with every new canister. This is necessary to reset the lubricator for the next service cycle.

6.5 5.5 Lubricator status Overload The grease point should be manually purged to check for blockages or problems. If free delivery of grease cannot be re-established the root cause of the high resistance must be investigated and rectified. OL stands for overload and indicates that resistance to lubricant delivery has been too high. Double RED flash every 7 seconds. Potential causes of an overload include: > plug of grease caused by excessive oil bleed; > Low temperatures which have affected lubricant pumpability; > n extended shutdown during which the resistance to grease flow to idle equipment has increased; > Poor installation practices such as grease lines which are too narrow. Overload is indicated by OL on the display screen and red flashing lights. If a manual grease kit is in place, close the valve so that the lubricator is not damaged during manual purging. The resistance to lubricant dispensing has been too high for the drive system to overcome and as a consequence overload has been registered. Lubricant dispensing has stopped.

C Purge the lubrication point using a manual grease gun and confirm that grease can be freely received. D fter approx. 1 minute open the ball valve. Reopening too quickly can allow grease pressure within the line to damage the lubricator. G If the short run cycle is successful the lubricator will return to normal operation, showing the time setting. H If the lubricator returns to overload again contact your supplier of perma lubricators to seek further technical support. E Press the SET button for 1 second to turn lubricator off. Press for another second to turn back on. F short run cycle will begin automatically. TIP For step C it is always preferable to use a manual grease gun, rather than a battery operated grease gun or an air operated grease pump. Using a manual grease gun will provide the operator with the opportunity to get a direct feel for the resistance against grease flow and how it changes as grease is pumped into the point.

6.65.5 5.5 Lubricator status Low battery 6.7 Lubricator status Fault The display shows Lo, meaning low. The display shows Er, meaning error. Double RED flash every 2 seconds. Double RED flash every 2 seconds. The battery which has been installed is either damaged or is depleted. new battery set must be used. Contact your perma supplier if a new battery set is found to be defective. The lubricator drive system has sustained damage and will not work. Contact your supplier of perma products for further advice.

7 Inspection guidelines C Check, mark and date the position of the piston. Compare the position to the expected piston position. D Refit lubricator cover. The periodic inspection of lubricators is important to support the integrity of the overall lubrication program. The following points are important: > Inspection of lubricators should be carried out by a competent person who understands the various display and light sequence combinations. > permanent marker should be carried in order to mark and date the piston positions. Remove lubricator cover. Leave the lubricator in its mounted position to complete the inspection. Confirm status using the display screen / flashing lights. The time setting on the display and a green light indicates normal operation. E Check the condition of fittings and grease lines. Repair or raise work orders as required.

8 Service guidelines C Exchange lubricant canister and battery set. D Insert new battery set, attach new canister and re-assemble. n automatic self test will occur. The service procedure for the perma STR VRIO is summarised here. Important points to note include: > LWYS exchange battery set; > LWYS record service dates on canister; > Lubricators can be serviced without removing the clear wet cap; > Replacing the battery set automatically resets the lubricator so there is no need to turn lubricators OFF and then ON again when servicing. Confirm lubricator status via display screen & piston level. Do not turn the lubricator off. Remove lubricator, disassemble & remove battery set using eject trigger. E Lubricator will start automatically. Observe first run cycle and afterwards confirm that the setting is correct F Record installation and next service dates on canister and remount to lubrication point.

HTL perma ustralia Pty Ltd 150 Highbury Road URWOOD VIC 3125 USTRLI technical@perma.com.au www.perma.com.au