1551A Ex/1552A Ex. Calibration Manual. Stik Thermometer

Similar documents
Calibration Manual. Detachable Jaw True-rms Clamp Meter

i400s Calibration Information Introduction

323/324/325 Clamp Meter

Tachometer. English. Users Manual

P5510. Users Manual. Pneumatic Comparison Test Pump

302+/303 Clamp Meter. Users Manual

80PK-2A Type K Immersion Probe

Infrared Thermocouple Probe

373 Clamp Meter. Users Manual

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

365 Detachable Jaw True-rms Clamp Meter

362 Clamp Meter. Users Manual

P5514, P5514-V & P5514-EP Hydraulic Comparison Test Pump

Temperature Calibrator

362 Clamp Meter. Users Manual

Users Manual. MegOhmMeter

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

233 True-rms Remote Display Digital Multimeter Safety Information

Users Manual. Phase Rotation Indicator

Users Manual. Airflow Meter

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings


The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

700G Series. Users Manual. Pressure Gauge

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

i3000s/i2000 Flex AC Current Probe

Go to to register your product and find more information.

707Ex. Users Manual. ma Calibrator

Visit us at

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

719 Series. Pressure Calibrator with Electric Pump. Product Overview (E)

80PK-8 Type K Thermocouple Pipe Clamp Temperature Probe

1000FLT. Users Manual. Fluorescent Light Tester

716 Pressure Calibrator

MegOhmMeter. Users Manual

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

5618B Platinum Resistance Thermometer User s Guide

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

712 RTD Calibrator. Instruction Sheet. Introduction

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

PK-8270-X/PK-8370-X. Lines and Fittings Kit. Instructions. Introduction. How to Contact Fluke Calibration

717 Series. Pressure Calibrators. Instruction Sheet. Introduction

721Ex. Users Manual. Pressure Calibrator

Automatic Pressure Calibrator. 3-Year Limited Warranty. See the Users Manual for the full warranty.

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

PY-11 Voltage & Continuity Tester

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

5616 Platinum Resistance Thermometer User s Guide

700G Series Pressure Gauges

KMP Insulation-Continuity Tester. Users Manual

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

THWD-3 and TH-3 Relative Humidity and Temperature Meters

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

TMD90A Dual Input Digital Thermometer

PK-VLV-ABORT-100M, PK-VLV-ISO-40M, PK-VLV-ISO-100M

TIME-10 Process Control Stopwatch

2-Year Limited Warranty. See the Users Manual for the full warranty.

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

9142-B-P-156/AF. User s Guide. Field Metrology Well. Distribution is limited to DoD and U.S. DoD contractors only.

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

SLA Battery Capacity Analyzer

SOIL RESISTIVITY TESTER

Instruction Manual. Ex-Time 40 / 50

KMP7010. Ground Resistance Tester. Users Manual

Model 1672, 1673 Triple Output Power Supply

Ti300 PRO, Ti400 PRO, Ti450 PRO, Ti450 SF6, Ti480 PRO Thermal Imagers

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

TACH-10 Contact / Non-Contact Tachometer

Megohmmeter Test Probe

Model 1693, 1694 Switching DC Power Supply

Ti200, Ti300, Ti400, Ti450, Ti480 Thermal Imagers

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

OPERATION MANUAL MILLIAMP PROCESS CLAMPMETER MODEL - KM 071 LIST OF PRODUCTS

718 30G/100G. Users Manual. Pressure Calibrator. 99 Washington Street Melrose, MA Phone Toll Free

DT304. Digital Temperature Logger INSTRUCTION MANUAL

IR-500 Infrared Thermometer / Voltage Detector / Flashlight

4-20mA DC PROCESS CLAMP METER

H2, HV2R, HV2G Rotary Laser Levels

Switching DC Power Supply

P5515, P5515-V, & P5515-EP Hydraulic Comparison Test Pump

BMRX Series ROTARY LEVEL CONTROL

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

Thermocouple Thermometer Models

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

TMA5 Mini Vane Anemometer

718 Series. Users Manual. Pressure Calibrator

OPERATING INSTRUCTIONS

80 Series V Digital Multimeter Safety Information

This manual covers the following model:

Cable Length Meter INSTRUCTION MANUAL

ANALOG INSULATION RESISTANCE TESTER

User Guide. Model Insulation Tester / Megohmmeter. Introduction

3-Year Limited Warranty. See the Users Manual for the full warranty.

Transcription:

1551A Ex/1552A Ex Stik Thermometer Calibration Manual November 2010 2010 Fluke Corporation. All rights reserved. Printed in USA. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY Each Fluke product is warranted to be free from defects in material and workmanship under normal use and service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke does not warrant that software will be error free or operate without interruption. Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts when product purchased in one country is submitted for repair in another country. Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, or replacement of a defective product which is returned to a Fluke authorized service center within the warranty period. To obtain warranty service, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that service center, with a description of the difficulty, postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition of operation or handling, including overvoltage failures caused by use outside the product s specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair costs and obtain authorization before commencing the work. Following repair, the product will be returned to the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges (FOB Shipping Point). THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY. Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other provision. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands 11/99

Table of Contents Title Page Introduction... 1 How to Contact Fluke... 1 Safety Information... 2 ATEX Safety Information... 3 Symbols... 3 Approvals... 4 Specifications... 4 Calibration... 5 Overview... 5 Recommended Equipment... 6 Initial Setup... 6 Record as-found Calibration Parameters... 7 Evaluate as-found Measurement Errors... 7 Adjustment at the Low Calibration Point... 8 Adjustment at the Zero Calibration Point... 9 Adjustment at the High Calibration Point... 9 Set the Calibration Date... 10 Evaluate as-left Measurement Errors... 10 Record as-left Calibration Parameters... 11 Maintenance... 11 Clean the Product... 11 Battery Replacement... 11 i

1551A Ex/1552A Ex Calibration Manual ii

List of Tables Table Title Page 1. Symbols... 3 2. Recommended Equipment... 6 3. As-found Calibration Parameters... 7 4. Test Temperatures... 7 5. As-found Measurement Errors... 8 6. Low-Adjustment Temperature... 8 7. Zero Adjustment Temperature... 9 8. High Adjustment Temperature... 9 9. As-left Measurement Errors... 10 10. As-left Calibration Parameters... 11 11. Approved Batteries... 12 iii

1551A Ex/1552A Ex Calibration Manual iv

List of Figures Figure Title Page 1. Battery Replacement... 12 v

1551A Ex/1552A Ex Calibration Manual vi

Introduction The Stik Thermometer (the Product) is a precision digital thermometer that can be used as an alternative to mercury liquid-in-glass (LIG) thermometers. It can also be used as a reference standard for other types of digital or analog thermometers. Because of its intrinsically safe certification, it can be used in many of the same hazardous locations as analog thermometers. For complete usage instructions, see the 1551A Ex/1552A Ex Users Manual. How to Contact Fluke To contact Fluke, call one of the following telephone numbers: Technical Support USA: 1-800-44-FLUKE (1-800-443-5853) Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-675-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Or, visit Fluke's website at www.fluke.com. To register your product, visit http://register.fluke.com. To see, print, or download the latest manual supplement, visit http://us.fluke.com/usen/support/manuals. 1

1551A Ex/1552A Ex Calibration Manual Safety Information A Warning identifies conditions and actions that pose hazard(s) to the user. A Caution identifies conditions and procedures that could cause Product damage, equipment under test damage, or permanent loss of data. Symbols used on the Product and in this manual are explained in Table 1. XWWarning To prevent possible electrical shock, fire, or personal injury: Use the Product only as specified, or the protection supplied by the Product can be compromised. Do not use the Product to measure the temperature of hazardous live components. Do not open the Product case. If you open the case, the Ex approval is not applicable. Change the batteries only in areas that are not Exhazardous. Use only specified approved batteries in the Product. Refer to the battery replacement instructions for a list of approved batteries. Do not use and disable the Product if it is damaged. Replace the batteries when the low battery indicator shows to prevent incorrect measurements. Check for proper operation of the Product before taking it into a hazardous area. Should the Product not operate as expected do not take the Product into a hazardous area and return it to the manufacturer for inspection. The Product is intended for installation only in locations providing adequate protection against the entry of solid foreign objects or water capable of impairing safety. WCaution To prevent possible damage to the Product or to equipment under test: If the display message changes to OL, the range limit is exceeded and the Product must immediately be removed from the heat source to prevent damage. Do not immerse the Probe beyond its maximum immersion depth. This may damage its internal electronics. See Immersion Depth and Usage later in this manual. DO NOT drop or strike the Probe in any way. Mechanical shock damages the Probe internally and affects it calibration. 2

Stik Thermometer Safety Information If the Product overheats or is exposed to sudden physical shock, examine it for damage that can cause a safety risk. If possible, compare the displayed temperature to a known reference before Product use. If not sure, send the Product to Fluke Corporation. Refer to How to Contact Fluke. Substitution of components will impair suitability for hazardous locations. ATEX Safety Information This manual contains data and safety regulations that must be followed for safe, reliable use of the Product in hazardous areas under the detailed conditions. If you do not follow these instructions, personal injury or Product damage can occur. Violation of applicable legislation can also occur. Read the full manual before you use the Product. To make sure of safe Product operation, fully follow all instructions and warnings in the manual. If you are not sure (due to translation and/or printing errors), refer to the English manual. An Ex-hazardous area, as used in this manual, refers to an area made hazardous by the possible presence of flammable or explosive vapors. These areas are also referred to as hazardous locations. Ex ib IIB T4 Gb ( 10 C Ta +50 C) ITS10ATEX27114X Ex ib IIB T4 Gb II 2 G IECEx ITS10.0049 0344 Manufactured by Martel Electronics, Inc., 3 Corporate Park Dr. Derry, NH, USA gjo006.eps Symbols International symbols used on the Product and in this manual are explained in Table 1. Table 1. Symbols Symbol Meaning Symbol Meaning J Earth ground M Battery W Risk of Danger. Important information. See Manual. X Hazardous Voltage ~ P Do not dispose of this product as unsorted municipal waste. Go to Fluke s website for recycling information. ( Conforms to relevant European Union directives. Conforms to ATEX requirements 3

1551A Ex/1552A Ex Calibration Manual Approvals The Product meets the above requirements using: EN 60079-0:2006 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES -- PART 0: GENERAL REQUIREMENTS (IEC 60079-0:2004 (MOD)) EN 60079-11:2007 EXPLOSIVE ATMOSPHERES -- PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY "I" (IEC 60079-11:2006 (EQV) + CORRIGENDUM DEC. 2006 (EQV)) Manufactured by Fluke Corporation: Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. P.O. Box 1186 5602 BD Eindhoven The Netherlands 4 Specifications (Ambient: 23 C ±5 C) Measurement Range 1551A Ex... 50 C to 160 C ( 58 F to 320 F) 1552A Ex... 80 C to 300 C ( 112 F to 572 F) Accuracy (1 year)... ±0.05 C (0.09 F) Resolution... Selectable (0.1, 0.01, 0.001) factory default is 0.01 Sample Rate... User selectable 0.5/sec, 1/sec or 2/sec factory default is 1/sec Operating Temperature Range of Readout:... 10 C to 50 C (14 F to 122 F) Probe Response Time... Approximately 20 seconds EMC Compliance... EN61326:2006 Annex C CISPR 11, Edition 5.0-2009 Class B Humidity Range... 0 to 95 % RH Non-condensing Storage Temperature Range... 20 C to 60 C ( 4 F to 140 F) Enclosure Rating... IP50 Readout Temperature Coefficient... Add ±10 ppm/ C of full scale temperature from 10 C to 18 C and 28 C to 50 C Probe Temperature Coefficient... 0.00385 Ω/Ω/ C nominal

Stik Thermometer Calibration Nominal Probe Resistance at 0 C... 100 Ω Probe Hysteresis... ±0.01 C Power... 3 AAA alkaline batteries (Must use only approved batteries. See Table 2) Battery Life... Approximately 300 hours without back light Battery Save (auto-off) Range... Selectable from 1 to 30 minutes or can be disabled Size (readout only)... Approximately 4 in. x 2 in. x 1 in. Probe Size... 1551A-9: 4.8 mm x 229 mm (3/16 in. x 9 in.) 1551A-12: 6.35 mm x 305 mm (1/4 in. x 12 in.) 1551A-20: 6.35 mm x 508 mm (1/4 in. x 20 in.) 1552A: 6.35 mm x 305 mm (1/4 in. x 12 in.) Weight... 6.9 oz Calibration XWWarning To prevent possible electrical shock, fire, or personal injury, the RS-232 interface must not be used in hazardous areas. This procedure is to be considered a general guideline. Each laboratory should develop their own specific procedure based on their equipment and requirements. The procedure should be accompanied by an uncertainty analysis also based on the laboratory s equipment and environment. Calibration should only be performed by qualified personnel. The technician should be familiar with the 1551A Ex/1552A Ex Users Manual. The calibration must be performed in the following ambient conditions: Temperature: 23 C ±2 C Relative humidity: 70 % maximum Overview The calibration consists of inserting the Product probe into a temperature bath having a known temperature and observing the difference between the temperature measured by the Product and the known temperature of the bath. The temperature of the bath is determined using an accurate reference thermometer. An equilibration block helps to ensure that the temperatures of the reference thermometer and 1551A Ex/1552A Ex Thermometer are uniform and stable. If necessary, the calibration parameters in the Product can be adjusted to improve its accuracy. Adjustments are made by sending the appropriate command to the Product through an RS-232 cable connected to a computer. For completeness of documentation, the calibration parameters should be recorded before and after adjustment. In summary, the main calibration steps are as follows: Record as-found calibration parameter values Evaluate as-found measurement errors Adjust the calibration parameters Evaluate as-left measurement errors Record as-left calibration parameters values 5

1551A Ex/1552A Ex Calibration Manual Recommended Equipment The equipment listed in Table 2 will satisfy the calibration requirements: Table 2. Recommended Equipment Equipment Temperature Baths Reference Thermometer Reference Thermometer Readout Computer Recommended Model Fluke 6331 40 C to 300 C Hot Bath Fluke 7381-80 C to 110 C Cold Bath Fluke 7196 Equilibration Block Fluke 5699-S Extended Range Metal-Sheath SPRT 1594A Super-Thermometer readout Computer with an RS-232 com port RS-232 serial cable Terminal software to communicate with the 1551A Ex/1552A Ex Thermometer Initial Setup Check the batteries in the Product and replace them if necessary. The battery level indication is found in the Setup menu. Several settings in the Setup menu relate to measurement and should be set as follows: Sample Rate: 1 per second Damping: OFF Display Resolution: 0.001 Auto Power Off: OFF The unit of measurement in the 1551A Ex/1552A Ex Thermometer may be set to C or F, but must match the unit of the reference thermometer. The baud rate in the computer software must match the baud rate of the 1551A Ex/1552A Ex Thermometer, which is usually 9600 but may be set to 2400. 6

Stik Thermometer Calibration Record as-found Calibration Parameters Before any adjustments are made, the present values of the Product calibration parameters should be recorded. Connect the serial cable between the computer and the Product. The commands used to read the values of the calibration parameters are given in Table 3. Commands must be terminated with a carriage return character. Table 3 may also be used to record the values of the calibration parameters. Table 3. As-found Calibration Parameters Parameter Command Value (fill in) TEMP1 ADJ1 TEMP2 ADJ2 TEMP3 ADJ3 DATE CAL:USER:TEMP1? CAL:USER:ADJ1? CAL:USER:TEMP2? CAL:USER:ADJ2? CAL:USER:TEMP3? CAL:USER:ADJ3? CAL:DEV:DATE? Evaluate as-found Measurement Errors The Product should be tested to evaluate its accuracy before any adjustments are made. It is recommended that it be tested near the five temperatures listed in Table 4, depending on the model. Table 4. Test Temperatures Point 1551A Ex 1552A Ex 1-50 C -80 C 2-25 C -25 C 3 0 C 0 C 4 100 C 100 C 5 157 C 300 C At each of the test temperatures, readings are recorded of the temperature of the reference thermometer and the indication of the Product. Before recording the readings, make sure the temperatures of the bath, reference thermometer, and 1551A Ex/1552A Ex Thermometer are settled and stable. 7

1551A Ex/1552A Ex Calibration Manual At each calibration point the measurement error may be calculated by subtracting the reference thermometer temperature from the 1551A Ex/1552A Ex temperature. The temperatures and measurement errors may be recorded in Table 5. Table 5. As-found Measurement Errors Point Reference (fill in) 1551A Ex/1552A Ex (fill in) Error (fill in) 1 2 3 4 5 If the measurement errors are well within the specified accuracy, it may not be necessary to adjust the calibration parameters. If the error is larger than desired (say 50 % of the specified accuracy), then adjustments to the Product calibration parameters are necessary. Proceed to the next section. Adjustment at the Low Calibration Point When necessary, the first adjustment is made for the low end of the temperature range of the Product. Set the bath temperature to the Low Adjustment Temperature given in Table 6, depending on the model. Make sure the temperatures of the bath, reference thermometer, and Product are settled and stable before proceeding. Table 6. Low-Adjustment Temperature Point 1551A Ex 1552A Ex Low 50 C 80 C Before adjustments to any calibration parameters can be made, access to the protected calibration parameters must be enabled by sending the following command to the Product through the serial interface: SYST:PASS:CEN <password> The parameter <password> is the current password, originally 1234. To make an automatic adjustment at the low calibration point, issue the following command: CAL:USER:LOW <temperature> The parameter <temperature> is the temperature of the bath as measured by the reference thermometer. Product accepts a temperature value with up to three decimal places of resolution. The temperature value must be in the same unit in which the 1551A Ex/1552A Ex is measuring. The command will set the value of the CAL:USER:TEMP1 parameter to the given temperature and automatically adjust the CAL:USER:ADJ1 parameter to cause the Product to measure the given temperature accurately. The adjustment made here will not affect the measurements at the other Adjustment temperatures. Allow the readings of the Product to settle and then verify that the readings match the temperature of the reference thermometer and are well within the specified accuracy of the 1551A Ex/1552A Ex. 8

Stik Thermometer Calibration Adjustment at the Zero Calibration Point The next adjustment is made for the middle of the temperature range of the Product. Set the bath temperature to the Zero Adjustment Temperature given in Table 7. Make sure the temperatures of the bath, reference thermometer, and the Product are settled and stable before proceeding. Table 7. Zero Adjustment Temperature Point 1551A Ex 1552A Ex Zero 0 C 0 C To make an automatic adjustment at the Zero calibration point, issue the following command: CAL:USER:ZERO <temperature> The parameter <temperature> is the temperature of the bath as measured by the reference thermometer. The Product accepts a temperature value with up to three decimal places of resolution. The temperature value must be in the same unit in which the Product is measuring. The command will set the value of the CAL:USER:TEMP2 parameter to the given temperature and automatically adjust the CAL:USER:ADJ2 parameter to cause the Product to accurately measure the given temperature. This adjustment will not affect the measurements at the other Adjustment temperatures. Allow the readings of the Product to settle and then verify that the readings match the temperature of the reference thermometer well within the specified accuracy of the 1551A Ex/1552A Ex. Adjustment at the High Calibration Point The final adjustment is made for the high end of the temperature range of the Product. Set the bath temperature to the High Adjustment Temperature given in Table 8, depending on the model. Make sure the temperatures of the bath, reference thermometer, and Product are settled and stable before proceeding. Table 8. High Adjustment Temperature Point 1551A Ex 1552A Ex High 157 C 300 C To make an automatic adjustment at the High calibration point, issue the following command: CAL:USER:HIGH <temperature> The parameter <temperature> is the temperature of the bath as measured by the reference thermometer. The Product accepts a temperature value with up to three decimal places of resolution. The temperature value must be in the same unit in which the Product is measuring. 9

1551A Ex/1552A Ex Calibration Manual The command will set the value of the CAL:USER:TEMP3 parameter to the given temperature and automatically adjust the CAL:USER:ADJ3 parameter to cause the Product to measure the given temperature accurately. The adjustment made here will not affect the measurements at the other Adjustment temperatures. Allow the readings of the Product to settle and then verify that the readings match the temperature of the reference thermometer well within the specified accuracy of the 1551A Ex/1552A Ex. Set the Calibration Date The date of calibration should be stored in the Product using the following command: CAL:DEV:DATE <year>,<month>,<day> Parameters <year>, <month>, and <day> are numbers representing the year, month, and day of the month respectively. After all the adjustments have been made and the calibration date has been set, protection of the calibration parameters should be restored using the following command: SYST:PASS:CDIS (Protection will always be restored when the Product is switched on.) Evaluate as-left Measurement Errors After all adjustments have been made, the Product should be subjected to a final test to ensure that it is measuring accurately over its entire range. The measurements are collected and errors are evaluated in the same way that was explained in Evaluating Asfound Measurement Errors. Table 9 may be used to record the as-left data. 1 2 3 4 5 Table 9. As-left Measurement Errors Point Reference (fill in) 1551A Ex/1552A Ex (fill in) Error (fill in) Record as-left Calibration Parameters As the last step in the calibration procedure, the final values of the Product calibration parameters should be recorded. The commands required to read the values of the calibration parameters are given in Table 10. Each command must be terminated with a carriage return character. The table may also be used to record the values of the calibration parameters. Table 10. As-left Calibration Parameters Parameter Command Value (fill in) TEMP1 ADJ1 TEMP2 ADJ2 TEMP3 ADJ3 DATE CAL:USER:TEMP1? CAL:USER:ADJ1? CAL:USER:TEMP2? CAL:USER:ADJ2? CAL:USER:TEMP3? CAL:USER:ADJ3? CAL:DEV:DATE? 10

static awareness A Message From Fluke Corporation Some semiconductors and custom IC's can be damaged by electrostatic discharge during handling. This notice explains how you can minimize the chances of destroying such devices by: 1. Knowing that there is a problem. 2. Learning the guidelines for handling them. 3. Using the procedures, packaging, and bench techniques that are recommended. The following practices should be followed to minimize damage to S.S. (static sensitive) devices. 1. MINIMIZE HANDLING 3. DISCHARGE PERSONAL STATIC BEFORE HANDLING DEVICES. USE A HIGH RESIS- TANCE GROUNDING WRIST STRAP. 2. KEEP PARTS IN ORIGINAL CONTAINERS UNTIL READY FOR USE. 4. HANDLE S.S. DEVICES BY THE BODY.

5. USE STATIC SHIELDING CONTAINERS FOR HANDLING AND TRANSPORT. 8. WHEN REMOVING PLUG-IN ASSEMBLIES HANDLE ONLY BY NON-CONDUCTIVE EDGES AND NEVER TOUCH OPEN EDGE CONNECTOR EXCEPT AT STATIC-FREE WORK STATION. PLACING SHORTING STRIPS ON EDGE CONNECTOR HELPS PROTECT INSTALLED S.S. DEVICES. 6. DO NOT SLIDE S.S. DEVICES OVER ANY SURFACE. 9. HANDLE S.S. DEVICES ONLY AT A STATIC-FREE WORK STATION. 10. ONLY ANTI-STATIC TYPE SOLDER- SUCKERS SHOULD BE USED. 11. ONLY GROUNDED-TIP SOLDERING IRONS SHOULD BE USED. 7. AVOID PLASTIC,VINYL AND STYROFOAM IN WORK AREA. PORTIONS REPRINTED WITH PERMISSION FROM TEKTRONIX INC. AND GERNER DYNAMICS, POMONA DIV. Dow Chemical

Stik Thermometer Maintenance Maintenance Clean the Product WCaution To prevent possible damage to the product or to equipment under test, do not use abrasive cleaners. They will damage the case. To clean the Product, use a cloth with a mild cleaning solution. Battery Replacement XWWarning To prevent possible explosion, fire, or personal injury: Change the batteries only in areas that are not Exhazardous. Replace the batteries when the low battery indicator shows to prevent incorrect measurements. WCaution To prevent possible damage to the Product or to equipment under test: Remove batteries to prevent battery leakage and damage to the Product if it is not used for an extended period. Be sure that the battery polarity is correct to prevent battery leakage. 11

1551A Ex/1552A Ex Calibration Manual To change the batteries, see Figure 1: 1. Use a flat-blade screwdriver to remove the battery door screw. 2. Remove the battery door to access the three AAA batteries. 3. Replace only with approved AAA batteries listed in this document. See Table 11. Any substitution voids the Product safety rating. 4. Make sure the battery polarity is correct. 5. Replace the battery door and install the screw. gjo003.eps Figure 1. Battery Replacement Table 11. Approved Batteries Battery Manufacturer Type Alkaline AAA Duracell Rayovac Energizer Panasonic LR03/MN2400 LR03/824 LR03/E92 LR03X 12