Locktite Manual Reset Gas Shut-Off Valves

Similar documents
Installation Instructions

Eclipse AutoTite Automatic Gas Shut-Off Valves

North American Automatic Manual Reset and Motorized Valves

Eclipse AutoTite Automatic Gas Shut-Off Valves

Maxon Shut-Off and Vent Valves General Purpose

Oil Electro-mechanical Valves Hazardous Locations

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

I-BFV.KIT Butterfly Valve Gear Operator Replacement

SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function

O.K. Safety first CDN USA. Table of Contents. Approvals. Attention IFGC CSA UL ANSI NFPA

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

IOM Manual. IOM Manual. Series 76/77.

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

GBV-G Balancing Valves

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

Installation & Maintenance Instructions for FSQC 100 Ampere Receptacle

V5197A Firing Rate Gas Valve

Maxon Shut-Off and Vent Valves General Purpose

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

Biogas safety control equipment

Installation& Maintenance Instructions

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

ELECTRIC ACTUATOR 94OE IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

ELECTRIC ACTUATOR HVAC/BAC ELECTRIC IOM. E024, EO25, E026, EO29 & E030 Installation Operation and Maintenance Instructions TABLE OF CONTENTS

MC-351, 421, 431, MC-4311

Levalarm Gold. Installation, Operation, & Maintenance Instructions R500.E253A 03/16/2016

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

VA-908x Series Electric Rotary Actuators for Two-Position and Modulating Service

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

North American Manual Reset and Motorized Valves

OSYSU Series Outside Screw and Yoke Valve Supervisory Switch

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

Installation Operation Maintenance

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

GE CONSUMER & INDUSTRIAL

INSTRUCTION MANUAL RECTANGULAR BUTTERFLY VALVE 3-SIDED SEAT

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

Electric Actuator Instructions

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Rectangular Butterfly Valve

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

Instructions for Installation, Operation, Care and Maintenance

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

The installation and maintenance of this product must be done under the supervision of an experienced

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

TECHNICAL DATA 1-1/2 (dn40)

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

V9055A,D Modulating Fluid Power Gas Valve Actuator

ONYX VALVE CO MODEL DEC Installation & Maintenance

of wet barrel hydrants, hydrant valves and hydrant tools.

Valve Body Capacities/Specifications

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

Quarter Master Series 94 Actuator

Model CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data

AE Installation Operation & Maintenance Instructions

MA-5200 Series MA-5300 Series

CIRCLE SEAL CONTROLS

4 - Way Control 4 - Way Control 4 - Way Control with lock

ONYX VALVE CO MODEL DAC-ADA Installation & Maintenance

TECHNICAL DATA. Table 1: Model F1 Dry Valve Part Numbers and Specifications

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

Worldwide Contacts.

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

V5055A-F Industrial Gas Valves

Pilot-Operated Regulators

Installation, Operation and Maintenance Manual for the HE Series

EW 350 ELECTRIC ACTUATOR INSTALLATION, MAINTENANCE AND OPERATION MANUAL

Series 758 FireLock Actuated System Valve

B21 Series BASOTROL Gas Valve

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

Confidence with the global standard in pressure relief devices

HS1C-P Interlock Plug Unit with Door Lock

Pressure and Temperature Switches

Eclipse Hermetic Gas Boosters

KEY PORT SERIES 400 ECCENTRIC VALVES. Compact Size. Light Weight. UL Listed. CSA Certified. CSA Certified. UL Listed

KEY PORT SERIES 400 ECCENTRIC VALVES. Compact Size. Light Weight. UL Listed. CSA Certified. CSA Certified. UL Listed

INSTRUCTION MANUAL ACTUATOR CLASSE I TYPE MA, MB

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Installation, Operation & Maintenance Manual

Eclipse RatioAir Burners

Installation, Operation And Maintenance Manual. Manual. For the 400 Series. ABZolute Seal. High Performance Butterfly Valve "Double Offset"

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

TECHNICAL DATA. model f-1 2. LISTINGS AND APPROVALS 3. TECHNICAL DATA. Page 1 of 11

Type EZR Relief Valve or Backpressure Regulator

Transcription:

Instruction Manual 750, 10/25/04 Locktite Manual Reset Gas Shut-Off Valves Series 200 LT Eclipse 200 LT valves are manually opening valves that automatically shut off the gas supply to a combustion system when any interlocking limit switch opens. The valve handle cannot be reset until the condition causing the open switch is corrected and all limit switches are closed. Typical limit switches include air pressure, gas pressure, temperature limit, and flame monitoring contacts. In the event of a power failure, the valve immediately closes. Series 200 LT valves include two visual indicators of open or closed position: a red flag visible in the plastic dome on top of the valve; and the reset handle position as indicated by cast markings on the operator case. These valves also include two SPDT micro-switches that can be used for auxiliary circuits. Two contacts are made when the valve opens, and two are made when the valve is closed. LISTED 326R CGA 3.9 CSA 6.5 / ANSI Z21.21 U.S. Patent No. 3,259,357 Canadian Patent No. 764,833 1.0 Materials of Construction 1.1 Operator housing heat treated cast aluminum. 1.2 Valve body cast aluminum or cast iron depending on model selected. 1.3 Valve disc steel with Hycar synthetic rubber bonded to provide soft seating on valve port. 1.4 Valve shaft stainless steel. 1.5 Closing spring stainless steel. 1.6 Main shaft gas seal plated steel with O-ring. 1.7 Main housing and terminal strip tightly sealed using nitrile (UL listed) gaskets in order to assure a raintight enclosure.

2.0 Operating Parameters & Requirements 2.1 Install a manual shutoff valve upstream of the Locktite to facilitate maintenance. 2.2 Before installing the valve, remove pipe scale and foreign matter that may have accumulated in the connecting pipes. 2.3 Ambient temperature at the location of the valve should not exceed 125 F. 2.4 Flow through the valve must be in the direction indicated by the arrow on the valve body. 2.5 Do not use the valve body to support piping. 2.6 LT valves are agency listed as follows: UL listed for air, natural gas, LP gas & hydrogen. FM approved for natural, LP & manufactured gases. CSA approved for natural, LP, mixed and manufactured gases. For wet or corrosive gases such as coke oven or digester gas, corrosion-resistant trim must be installed at Eclipse. Be sure your valve was ordered to suit your application. 2.7 See Figure 1 for allowable mounting positions. Figure1 Operator Orientation & Mounting Positions Factory Supplied Operator Position #1 (Standard) #2 #3 #4 Part Number Designation Assembly No. (None) Assembly No. -P2 Assembly No. -P3 Assembly No. -P4 Valve Mounted With Operator Straight Up or Down Valve Mounted With Wiring Box Cover Facing Up 200 LT valves can be supplied with the operator rotated in any of four positions with respect to the valve body, #1, #2, #3, and #4. Position #1 is supplied standard. Add -P2, -P3, or -P4 to the end of the assembly number to specify other mounting positions. The sketches above show the allowable mounting orientations for each of the four factory-supplied operator positions. The operator must not be mounted in a position nother than those shown. Note: Field changing the operator position can result in damage. Please contact your Eclipse representative if rotation of the operator after shipment is required. 3.0 Pressure Taps & Position Indicators 3.1 The valve body has a plugged test connection upstream and downstream of the valve disc for leakage test and connection of pressure gauges. 3.2 An indicating flag enclosed in a clear plastic housing on top of the valve operator provides visual indication of the valve position. When the red indicating flag is visible, the valve is open; when it is not visible, the valve is closed. 3.3 The reset handle can also be used as a valve position indicator since it is spring loaded and automatically returns to the reset position when the valve closes. 3.4 The operator is equipped with two internal SPDT microswitches. These switches are normally used for actuating an alarm signal or for enforced low fire start of the system. The switch is rated for 8 amps, 1/3 HP, 120 or 240 volts A.C. 2

4.0 Wiring 4.1 Check valve nameplate to make certain electrical characteristics correspond with electrical service being used. 4.2 All wiring connections should be made in accordance with local or regional electric codes. 4.3 All internal wiring is connected at the factory to a terminal block included in the built-in wiring compartment of the valve (see figure 4). Make all field connections to this terminal block. Strip the wire 1/4" to 3/8". Insert into the terminal opening and tighten the screws. Check for loose strands that may cause a short. Figure 4 Wiring Details 4.4 Wiring diagrams for the latching solenoid and microswitch(es) are located on the inside surface of the terminal block cover, and also in Figure 4. 4.5 The operator has two 1/2" threaded conduit connections for field wiring. Use wiring suitable for 75 C operation. 4.6 For raintight applications, wiring connections to the valve must be made with 90 close ell rigid conduit fittings. The conduit should travel downwards from the valve to cause water to flow away from the valve. Terminal Block Wiring Diagram 5.0 Maintenance 5.1 Every six months, lubricate the lever with light motor oil as shown to the right. 5.2 Since the LT valve is a safety device, test it regularly for proper functioning. Interrupt electrical power to simulate an unsafe condition. If the valve does not close immediately, remove it from service and replace. Oil Here 6.0 Replacement of Solenoid & Bracket Assembly (See Fig. 5 Page 4) 6.1 Remove main housing cover and gasket. 6.2 Remove the wiring box cover. Disconnect solenoid lead wires from the terminal block. 6.3 Remove the three 10-32 machine screws holding the cast solenoid bracket and microswitch bracket to the operator housing. Remove both brackets. 6.4 Mount the new solenoid and bracket assembly in the operator housing, replace the microswitch bracket, replace the three 10-32 screws, reconnect lead wires, and install main and side gaskets and covers. 3

Figure 5 View of Valve With Side Cover Removed Three 10-32 Screws Cast Solenoid Bracket Microswitch Bracket Solenoid Lead Wires Terminal Block 7.0 Changing The Mounting Position in The Field w Warning: Service must be done by a competent technician with prior experience and knowledge of safety shutoff valves and safe maintenance procedures. 7.1 Turn off the gas supply to the valve and disconnect the field installation elecrtical wiring before working on the valve. Conduit may also need to be removed to allow proper orientation in the new mounting position. 7.2 If the valve is not mounted, clamp the body in a vise. 7.3 Connect a flexible temporary power source to terminals 1 and 2. Apply power and move the handle to the open position. Look at the visual indicator to verify that the valve is open. Do not remove power during the following steps. 7.4 Loosen and remove the 8 hex-head bolts holding the operator to the valve body. 7.5 Carefully lift the operator straight up until the stem clears the body. 7.6 Inspect the gasket for any problem that may lead to gas leakage. If any problem is detected, stop and contact Eclipse. Instruction Manual 750 10/25/04 7.7 Rotate the operator to the desired position and carefully lower it straight into the valve body. 7.8 Replace and evenly tighten the 8 bolts to 50-60 lb-in (approximately ½ turn after the hex-head is finger tightened to contact the surface). 7.9 Interrupt the power source and observe that the valve closes. Reapply power and verify that the valve opens properly. 7.10 Disconnect the temporary power source. 7.11 Restore the field connections and perform gas leak age tests before putting the system into service.

Offered By: Power Equipment Company 2011 Williamsburg Road Richmond, Virginia 23231 Phone (804) 236-3800 Fax (804) 236-3882 www.peconet.com