UNP-U-Type Universal Panel Instructions

Similar documents
UNPWM-U-Type Universal Wall Mount Patch Panel Instructions

SYSTIMAX GS3 and 1100GS6 Evolve Modular Panel Instructions

UNP610-WM-12P Modular Jack Panel Installation

PATCHMAX GS3, GS6 and PowerSUM Modular Panels

SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions

SYSTIMAX 360 FTP Evolve Panel Instructions

8-Position Cat5E EMT Shielded Slim-Line Modular Plug

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

SYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions

SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

Engine 3 Installation

INSTALLATION GUIDE. LANmark EVO Series Snap-in Connector S-FTP STP

Switches 10AX/16AX. Safety. Easy Operation. Switch Mechanism. Characteristics of Urea Resin. Screwless Terminal (reduces installation work) Features

OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions

Replacing the Gear Drive Motor Assembly and GFCI Module for Operation with the Chain Drive Motor Assembly

FCategory 5e 110 Wiring

Voice/Data/ Video Tools

How to remove and replace the Foonf/Fllo fabric

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6 A, stainless steel

Fiber Connector Shelf (CCS)

TOOLS AND TESTERS TERA 10G 6A F/UTP 10G 6A UTP. System 6 UTP. Premium 5e F/UTP. Premium 5e UTP. Fibre Cable Assemblies, Connectors and Cable

Data sheet E-DAT modul Cat.6 A 8(8) jack, T568A

Customer Owned Copper Outside Plant Guidelines

CM52 Network Protector with Arc Flash Reduction Module

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Safe-T-element Installation Instructions

2015 Mustang Lightbar (All Models) CDC#

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

FIBER CONNECTOR SAFETY WARNINGS

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

PHOENIX MINI-GUARDIAN

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

ISSUER: WRC 10/29/10 ENGINEERING: PROD/MTL: QA APPROVAL: REVISION HISTORY

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

GENUINE PARTS INSTALLATION INSTRUCTIONS

* * APPLICABLE MODELS: 2017 > CX-5

2003 CR-V - A/T Shift Cable Replacement-Print Preview

Bel Stewart Connector

ET-PWR-END-KIT Installation Instructions (part #JSR00)

CASS Interface System Parts Section 1

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

SPEED CONTROL 4 AND 6 CYL. JEEP WRANGLER. Read entire instructions thoroughly before starting. INSTALLATION INSTRUCTIONS TOOLS REQUIRED:

GENUINE PARTS INSTALLATION INSTRUCTIONS

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

Installing the Switch

10260S Series Actuators Auto-Manual Switch Replacement Instruction

Mini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

Data sheet C6 A modul 24 port 180 M 1RU stainless steel

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

FAKRA-Compliant SMB Gen-4 Connector System

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

* * APPLICABLE MODELS: 2014 > Mazda 3

SCION FR-S FOG LIGHTS

Environmental Distribution Center (EDC-06P-NH)

ELECTRICAL CONNECTORS B.1

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

* * APPLICABLE MODELS: 2014 > Mazda 6

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Pretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)

Job Sheet 6 Installing the Combiner Box

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6A, light gray

ARB UTILITY MANAGEMENT SYSTEMS WATER ELECTRIC GAS. E-Coder)R900i Quick Install Guide. E-Coder)R900i QUICK INSTALL GUIDE

* * APPLICABLE MODELS: 2016 > CX-3

Fiber Splice Panel Rack Mount User Manual

Designed for the Street Proven on the Track

LEXUS GX TOWING HITCH Preparation

M7 R52S & R53 Cold Air Intake Installation Guide 53-3M7301

GENUINE PARTS INSTALLATION INSTRUCTIONS

Replacing the T320 Cooling System Components. Replacing a T320 Fan Tray. Removing a T320 Front Fan Tray

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

Shielded Connector Block for the NI PXI/PXIe-2532/2532B

2O3D3-19A REVB MOUNTING

Top Down Rollstar Shade Installation Instructions

2M Series Contacts and Tools

How to Replace a Switch

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

Premise Networks Division Product & Applications Guide Americas

HP Modular Cooling System 200/100 Options Installation Guide

GENUINE PARTS INSTALLATION INSTRUCTIONS

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

FAKRA-Comliant SMB 50-Ohm Inline Connectors 27 JUN 11 Rev E

GENUINE PARTS INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL ELECTRIC DOUBLE OVEN RANGE

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

PureNet Data Communication Products Premises Copper Products

Data sheet E-DAT modul 1 port UPk Cat.6 A, pure white

Rollstar Shade Installation Instructions

Transcription:

Issue 1, February 2015 Uniprise Solutions UNP-U-Type Universal Panel Instructions General The Uniprise Solutions UNP-U-type universal panels are available in a 24- or 48-port, straight or angled configuration. The panels exceed Category 5E, 6, or 10G standards and are designed to mount into a standard 19-inch (483mm) equipment rack. The panels accommodate either EIA-T568A or EIA-T568B wiring applications. Ordering information is listed below: Material ID Part No. Description 760180000 UNP-U-510-1U-24 Universal 510 24-port flat panel, 1U, CAT5E 760180018 UNP-U-510-2U-48 Universal 510 48-port flat panel, 2U, CAT5E 760180026 UNPA-U-510-1U-24 Universal 510 24-port angled panel, 1U, CAT5E 760180034 UNPA-U-510-2U-48 Universal 510 48-port angled panel, 2U, CAT5E 760180042 UNP-U-610-1U-24 Universal 610 24-port flat panel, 1U, CAT6 760180059 UNP-U-610-2U-48 Universal 610 48-port flat panel, 2U, CAT6 760180067 UNPA-U-610-1U-24 Universal 610 24-port angled panel, 1U, CAT6 760180075 UNPA-U-610-2U-48 Universal 610 48-port angled panel, 2U, CAT6 760162800 UNP-U-10G-1U-24 Universal 10G 24-port flat panel, 1U, 10G 760162818 UNP-U-10G-2U-48 Universal 10G 48-port flat panel, 2U, 10G 760162826 UNPA-U-10G -1U-24 Universal 10G 24-port angled panel, 1U, 10G 760162834 UNPA-U-10G -2U-48 Universal 10G 48-port angled panel, 2U, 10G How to Contact Us Uniprise Solutions Universal 24-Port Flat Panel and 24-Port Angled Panel To find out more about CommScope products, visit us on the web at / For technical assistance: - Within the United States, contact your local account representative or technical support at 1-800-344-0223. Outside the United States, contact your local account representative or PartnerPRO Network Partner. - Within the United States, report any missing/damaged parts or any other issues to CommScope Customer Claims at 1-866-539-2795 or email to claims@commscope.com. Outside the United States, contact your local account representative or PartnerPRO Network Partner. For RoHS Inquiries: CommScope Inc. Corke Abbey, Bray Co. Dublin, Ireland Attn: Legal Department 2015 CommScope, Inc. All rights reserved This product is covered by one or more U.S. patents or their foreign equivalents. For patents, see /ProductPatent/ProductPatent.aspx Page 1 of 8

Tools Required Phillips head screwdriver Cable jacket scoring tool D-914 punch tool with M110 blade. Specifications Wire Termination Wire Size: 22-24 AWG (0.64-0.51 mm) Solid Copper 22-24 AWG (0.64-0.51 mm) Seven Stranded Copper Insulation Size: 0.042 inch maximum DOD Insulation Types: Polyethylene, Polypropylene, and FEP IDC Reterminations: 20 minimum Modular Jack Mating Cycles: 750 minimum Environmental Data Temperature Range: -40 F (-40 C) to 158 F (70 C) (Storage) 14 F (-10 C) to 140 F (60 C) (Operational) Humidity: 95% Noncondensing Parts List Verify parts against parts list below: 24-Port Flat Panel 48-Port Flat Panel Quantity 24-Port Angled Panel 48-Port Angled Panel 1 24-port flat panel 1 48-port flat panel 1 24-port angled panel 1 48-port angled panel Description 4 4 4 4 P12-24 x ½ mounting screws 1 2 1 2 Cable management bar 4 8 4 8 Hook-and-loop straps 1 2 1 2 Termination manager kit 4 8 4 8 Rear label, T568A wiring 1 2 1 2 Front label card (4 labels per card) 1 2 1 2 Label cover card (4 label covers per card) 1 1 1 1 Instruction sheet WARNING Important Safety Instructions When using this product, the following basic safety precautions should be followed to reduce the risk of fire, electric shock, and injury to persons: 1. Never install communications wiring in wet locations unless it is designed for wet locations. 2. Never install this product during a lightning storm. There is a remote risk of electric shock. 3. Never touch uninsulated communication wiring or terminals unless the communication circuit has been disconnected at the network interface. 4. Caution: All wiring that connects to this equipment must meet applicable local and national building codes and network wiring standards for communication cable. Page 2 of 8

860584457 Step 1 Mount Panel to Rack 1. Mount panel to rack using the four 12-24 mounting screws provided. Step 2 Terminate Conductors on Rear of Panel T568 Wiring Pairs B A 1 2 3 4 5 6 7 8 8 7 6 5 W W W W 2 1 4 3 4 4 BR GR 3 2 OR BL 1 BR OR 2 3 GR BL 1 Entry holes Lock tab (2 places) Entry holes Modular Jack IDC Connector Front of Panel Back of Panel Fold slots (4 places) T568 Wiring Diagram Termination Manager Note: The module comes with a T568B wiring designation label installed. If T568A wiring is desired, first remove the "B" type label and then place the "A" type label. Do not place the "A" type label on top of the "B" type label. Note: If using Uniprise Solutions Ultra 10 U/UTP 10G4 and 10GN4 series cable, see preparation instructions on next page. 1. Prepare cable for termination. Terminate conductors on the IDC terminals per the wiring diagram shown above and utilizing the provided termination manager. 2. See pages 7 and 8 for correct procedure on using the termination manager. Page 3 of 8

Preparation of Uniprise Solutions Ultra 10 U/UTP 10G4 and 10GN4 Series Cable for Termination Trim flute close to jacket Pull flute off to one side Preparation of the Uniprise Solutions Ultra 10 U/UTP 10G4 and 10GN4 series cable is shown above. Termination of 25-Pair Cable on the UNP-U-510 Panels Note: If terminating 25-pair cables on the rear of a UNP-U-510 panel, do not use the termination managers. 1. Replace existing wiring labels on blocks with the provided 25-pair wiring labels prior to terminating the conductors. Do not place the 25-pair labels on top of the 4-pair labels. 2. Terminate conductors per wiring tables on the next page. 3. Position 25-pair cable in the center of the block and between the upper and lower contacts. 4. Prepare and place all of the conductors from the center of the block outward to each end, then use a D-914 single-pair impact tool to seat and cut the conductors. Page 4 of 8

860584457 Table A. 25-Pair Cable Terminations (B-Wiring Application) IDC No. 1 2 3 4 5 6 1 W/BL W/GY R/BR BK/G Y/O V/BL 2 BL/W GY/W BR/R G/BK O/Y BL/V 3 W/O R/BL R/GY BK/BR Y/G V/O 4 O/W BL/R GY/R BR/BK G/Y O/V 5 W/G R/O BK/BL BK/GY Y/BR V/G 6 G/W O/R BL/BK GY/BK BR/Y G/V 7 W/BR R/G BK/O Y/BL Y/GY V/BR 8 BR/W G/R O/BK BL/Y GY/Y BR/V Note: Pair 25 is used for spare pair. Table B. 25-Pair Cable Terminations (A-Wiring Application) IDC No. 1 2 3 4 5 6 1 W/BL W/GY R/BR BK/G Y/O V/BL 2 BL/W GY/W BR/R G/BK O/Y BL/V 3 W/G R/O BK/BL BK/GY Y/BR V/G 4 G/W O/R BL/BK GY/BK BR/Y G/V 5 W/O R/BL R/GY BK/BR Y/G V/O 6 O/W BL/R GY/R BR/BK G/Y O/V 7 W/BR R/G BK/O Y/BL Y/GY V/BR 8 BR/W G/R O/BK BL/Y GY/Y BR/V Note: Pair 25 is used for spare pair. Step 3 Install Cable Bar and Secure Cables 1. Once cables have been terminated, attach cable bar to rear of panel. For 48-port panels, two cable bars are provided. 2. Lay cables evenly in bends of cable bar and secure using the provided hook-and-loop straps as shown. Page 5 of 8

Step 4 Insert Labels and Label Covers 1. Print the port designations on the white label cards provided. Slide labels and label covers into the label holders from either end. Each label holder will accommodate labels up to 0.265 inches (6.7mm) high x 3.50 inches (89mm) wide. 2. Blank, voice, and data icons can be ordered separately in a wide variety of colors and placed into the pockets in the lower portion of the label holders. Note: Product code M61K-XX (blank, voice, and data icons) to be ordered separately. XX denotes the color abbreviation. 3. To print a designation label, go to http:///resources/labeling-templates and scroll down to Panels and select the proper label template. Note: Labeling website has two options for printing labels; letter size and A4 size. Page 6 of 8

860584457 Patch Panel Termination Manager Instructions The termination managers provide pair positioning, control, and strain relief features to the rear termination area of the panel. See Figure 1. Instructions for using the termination manager are listed below. Feed Pairs into Termination Manager (Figure 2) 1. Trim jacket back at least 3 inches (76mm) to expose twisted pairs. 2. Without crossing over or rearranging pairs out of the jacket, position pairs in-line per pair colors below: Entry holes Lock tab (2 places) Fold slots (4 places) Entry holes T568B Wiring Application (Shown) Blue, Brown, Orange, Green Figure 1. Termination Manager T568A Wiring Application Blue, Brown, Green, Orange 3. Insert pairs through 4 holes on top surface of termination manager, one pair per hole, as shown. Top surface 4. Continue to feed pairs through termination manager until resistance is encountered at the jacket. This will usually be about 1/4 inch (6mm) from the jacket. Fold Pairs into Slots (Figure 3) 5. Fold each pair over into adjoining slots on bottom end of termination manager. Conductor colors must be arranged in the slots as listed below: T568B Wiring Application (Shown) BL/OR Pairs Blue/Orange conductors on top BR/GR Pairs both White conductors on top T568A Wiring Application BL/GR Pairs Blue/Green conductors on top BR/OR Pairs both White conductors on top Important: Add twist as needed to align pairs with slots. Never remove twist for any pair. Do not allow pairs to untwist inside termination manager or inside cable jacket. 6. Ensure that both conductors of each pair are in slots completely without being pinched over bottom end surface. Blue pair Brown pair Green pair Orange pair Figure 2. Feed Pairs into Termination Manager Blue on top Orange on top White on top Figure 3. Fold Pairs Back into Slots Page 7 of 8

Snap Termination Manager onto Rear Housing (Figure 4) 7. Snap assembled termination manager onto rear housing with pair colors in proper position. Push on using the termination manager housing, not by pushing with the cable. (Ensure that both lock tabs on manager fully seat into rear housing). 8. After termination manager is snapped onto rear housing, untwist individual pairs fully and line up correct color conductor and white conductor with the label on the rear housing. Pairs folded back Seat Wires into IDC Terminal Slots (Figure 5) 9. Grasping each untwisted pair, push the conductors down into IDC terminal slots to seat them before punching down. Seat down into slots as far as possible. (It may be easier to use needle nose pliers to perform this task). 10. Using the D-914 punch tool with M110 blade on HI impact setting, punch down conductors making sure the tool is straight and that conductors fully engage in the IDC terminals. Stagger the punch-down tool up and down, so that it stays in alignment with the staggered terminal slots. Figure 4. Snap Termination Manager onto Rear Housing Remove twists, then push conductors down into terminal slots Recommendations to Aid Assembly 1. The termination manager should be snapped onto the rear housing immediately after the pairs have been fed and folded over into the slots. All termination managers should be installed on the panel before proceeding to seat and punch down conductors. 2. Flex cables down for easier access, then seat and punch down the entire top row of the panel. 3. Flex cables up for easier access, then seat and punch down the entire bottom row. Visible pair entry Figure 5. Seat Untwisted Pairs into IDC Terminal Slots Page 8 of 8