Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units

Similar documents
GEH-6259 Installation Instructions Voltage Conditioner Assembly

MicroVersaTrip Plus and MicroVersaTrip PM Conversion Kits For GE Types AK-25 and AKU-25 Low Voltage Power Circuit Breakers

EntelliGuard Power Circuit Breaker Accessories. Network Interlock for Ampere Circuit Breakers. Introduction. Operation

Power Break Circuit Breakers

Low Voltage WavePro TM and EntelliGuard TM Circuit Breakers Remote Racking Operator

Power Break II Switchboard

Spectra Series Power Panelboards. General. Installation. Bolt-On Circuit Breaker Kits. DEH059 Installation Instructions

DEH g Installation Instruction for Cable Operator Mechanisms for SE150, SF250, SG600 & SK1200 Spectra RMS Circuit Breakers

Operation and Maintenance Manual

CR193 B,C,D and E Vacuum Limitamp * Contactors

Zone Selective Interlock Module. For GE Circuit Breakers

Power Break II Circuit Breaker Accessories Motor Operator Mechanism

Section 3: Molded Case Circuit Breakers

Record Plus. Molded Case Circuit Breaker Accessories. Plug In Base. DEH40915 Installation Instructions

Test Cabinet (Inspection Box) Instructions. for Testing Accessories on Manually and Electrically Operated EntelliGuard G Low Voltage Circuit Breakers

DEF 005. WavePro Power Circuit Breakers A Frames, Vac. Renewal Parts

ProTrip Conversion Kits. For GE Types AK-15, AK-25, and AKU- 25 Low-Voltage Power Circuit Breakers INTRODUCTION. DEH Installation Instructions

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

Introduction. Installation. A Series Lighting Control Panelboards. DEH41081 Installation Instructions

Finger Cluster Replacement Parts Primary Disconnects for EntelliGuard* Retrofill Circuit Breakers

GE Consumer & Industrial Electrical Distribution. Power Break II. Insulated Case Circuit Breakers

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Power delivery for industrial facilities

Programmer Disconnect Accessory Manual for Retrofil CB

GE Energy. GE Panelboards. The right panelboard for any application. imagination at work

Modular Metering - Trip Unit for >1200A Mains DEH41187 Application Guide

Position Switch Kits Accessory Kits for EntelliGuard* Retrofill Circuit Breakers

GEF Renewal Pans. low Vohage Power Circuit Breakers. Type AKR-30S and AKRU-30S. www. ElectricalPartManuals. com

GE Energy Industrial Solutions. Aftermarket Catalog. imagination at work

CR193 Vacuum Limitamp* Contactors

GE Consumer & Industrial Electrical Distribution. Spectra Series Busway. Busway vs. Wire & Conduit. imagination at work

GE Industrial Solutions. EntellEon * Low-Voltage Power Panel. Simple. Responsive. Revolutionary.

GE Industrial Solutions Retrofill Door Assemblies for AKD-5, AKD-6, AKD-8 and AKD-10

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

GEH 6270C. Power Break II Circuit Breakers A Frames, Vac. User s Guide

GE Electrical Distribution. Gerapid High Speed DC Circuit Breakers. On the move. imagination at work

A-Series II Panelboards AD/AE/AQ Type P & N Panel THQB Three-Phase Circuit Breaker Kits

DEH Installation

www. ElectricalPartManuals. com

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Selection and Application Guide Supplement. WL UL Pole Circuit Breakers. usa.siemens.com/wlbreaker

DBR Receptacle Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

PLUGS AND RECEPTACLES: NEC/CEC HAZARDOUS LOCATION

Low Voltage Power & Insulated Case Circuit Breakers

Cradle Mounted Key Interlock Guide Frame Accessory

Power components for industry

SecoVac * Ground & Test Device

Section 3. Molded Case Circuit Breakers.

NEC DBR Receptacle: Class II, Division 1 and 2, Groups F, G Class III NEMA 3, 3R, 4, 4X, 9FG

www. ElectricalPartManuals. com Section 6 Low Voltage Power and DC Circuit Breakers

GE Industrial Solutions. DEH Installation and Maintenance Manual AKD-20 AR / Entellisys AR Exhaust Plenum System

A-Series II Panelboards AD/AE/AQ Type P & N Power Panel SE/TED Three-Phase Circuit Breaker Kits

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

Digitrip Retrofit System for the ITE LG-3000 (Frameless) Circuit Breaker

GE 8000-Line Motor Control Centers Mains, Feeders, Incoming Lines C-1

EntelliGuard R Retrofill Application Guide

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Mining service breakers with true rms sensing designed specifically for trailing cable applications

GE Industrial Solutions HPC * Switches New Generation. User s Guide. Note: Fuses are not supplied with the new HPC Switches.

Installation, Operation, and Maintenance Manual Retain for Future Use. EntelliGuard G Circuit Breaker

THQL1120AF2 THQL1120AF2 Arc Fault BRKR

Critical Power Switchboards. Selection and Application Guide

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

VL Circuit Breaker DG 150A frame

VL Circuit Breaker FG 250A frame Breaker type Defined by the 3rd character of the catalog number K Global, Non-interchangeable

Molded Case Circuit Breakers Section 3 Q-Line Circuit Breakers

S200-C, 480Y/277 VAC Supplemental protectors UL 1077, CSA 22.2

1 of 13 5/11/17, 2:59 PM

F-Series. Circuit Breaker

Enclosure for AMP1 Series Energy Meters with Swing Panel Kit

F-Series. Circuit Breaker

Table of Contents. For latest version, visit:

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Tenant Main Circuit Breakers. for GE Meter Mod * III Modular Metering

GE CONSUMER & INDUSTRIAL

Molded Case Circuit Breakers Section 6 Q-Line Circuit Breakers

www. ElectricalPartManuals. com Digitrip Retrofit System for BBC LKD 8 Breakers IL 33-LK8-2

Section 27. GE Publication Index

Typical AEP Panelboard

Installation Instructions for TMQV Circuit Breakers and Molded Case Switches

VL Circuit Breaker Features & Benefits. powerful ideas RELIABLE SOLUTIONS

www. ElectricalPartManuals. com Digitrip Retrofit System for the Westinghouse DA-50 IL 33-DAC-2 WARNING

Molded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1

Digitrip Retrofit System for General Electric AKR/AKRU-6D/7D-30S Series Breakers

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Allen-Bradley HP Inverting Fault Circuit Breaker Kit

Magnum IEC Air Circuit Breakers and Drawout Cassette Engineering Data

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Midwest Electric Products. Safety Switches Rugged, reliable and easy to install

E2 Application Matrix Product Information Sheet P/N Rev 4 15-AUG-2013

Accessories SU200M, SU200MR, and S200UDC UL 489, CSA 22.2 No. 5

Molded Case Circuit Breakers. Section 6. BuyLog Catalog 6-1

Digitrip Retrofit System for Allis-Chalmers LA-600 F Electrically Operated Fused Breakers

n Ilation instructions Load Center Transfer TMOperator

GEK41931B INSTRUCTIONS MULTI-CONTACT AUXILIARY RELAYS TYPE HFA73K. GE Protection and Control 205 Great Valley Parkway Malvern, PA

Transcription:

GE Energy Industrial Solutions GEH-6255 Installation Instructions Distribution Cable Harness For Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM, MicroVersaTrip PM or MicroVersaTrip Plus Trip Units For Catalog Number SDCHA11, SDCHA30, SDCHA60 Circuit Breaker Accessory Overview The General Electric Distribution Cable Harness is a modular connector used to carry a variety of electronic signals between Spectra RMS Molded-Case Circuit Breakers with microentelliguard TM or MicroVersaTrip PM/Plus Trip Units and Distribution Cable Accessories. The Distribution Cable accessories supported by the Distribution Cable Harness are as follows: Power Supply Plate Voltage Conditioner Plate Power Supply Assembly Voltage Conditioner Assembly Distribution Cable Junction Box Distribution Cable Extension Distribution Cable Terminal Block Voltage Module The Distribution Cable Harness is also used in GE Spectra Series Switchboards to either connect Distribution Cable Junction Boxes (Cat. Nos. SDCJBB and SDCJBBC) to other Distribution Cable Junction Boxes or to connect Distribution Cable Boxes to the Voltage Module. Because both ends are receptacles, you cannot use the Distribution Cable Harness as an extension cable; use the Distribution Cable Extension (Cat. Nos. SDCEA30 and SDCEA30C) for this application (microentelliguard TM Trip Units with 20-pin connectors use the SDCEA30C extension cable).

Figure 1 shows how the Distribution Cable Harness is used in a typical MicroVersaTrip PM system. Figure 2 shows how the Distribution Cable Harness is used in a typical MicroVersaTrip Plus system. The microentelliguard TM Trip Unit can be used with either configuration, i.e. Figure 1 or Figure 2. The connection diagram shown in Figure 2 applies to microentelliguard TM Trip Units with Basic Metering. Figure 1. Typical MicroVersaTrip PM Trip Unit System detailing the Distribution Cable Harness.

Figure 2. Typical MicroVersaTrip Plus Trip Unit System detailing the Distribution Cable Harness.

The electronic signals supported by the Distribution Cable Harness vary depending on the type of trip unit used; a list of supported functions is as follows: Spectra RMS Breaker with microentelliguard TM or MicroVersaTrip PM Trip Unit Control power (+24vdc) Control power (-common) System communications (Comm. +) System communications (Comm. -) Voltage A f (must be from Voltage Module or Voltage Conditioner Plate or Voltage Conditioner Assembly) Voltage B f (must be from Voltage Module or Voltage Conditioner Plate or Voltage Conditioner Assembly) Voltage C f (must be from Voltage Module or Voltage Conditioner Plate or Voltage Conditioner Assembly) another Distribution Cable Accessory, align the harness receptacle interlock with the plug hook of the mating Distribution Cable accessory and insert the receptacle into the plug until the interlock and hook overlap and catch (see Figure 4). To disconnect the Distribution Cable Harness, press down at the rear of the receptacle interlock until the interlock clears the hook, and remove the receptacle (see Figure 5). Spectra RMS Breaker with MicroVersaTrip Plus or microentelliguard TM (with Basic Metering) Trip Unit Control power (+24vdc) Control power (-common) Figure 3 shows the connector pinout for the Distribution Cable Harness for each type of trip unit. Figure 4. Side view of receptacle-plug connection insertion. Connections The Distribution Cable Harness contains a 12-pin receptacle connector on each end. The connectors are keyed so they cannot be inserted incorrectly into a mating 12-pin plug connector. To connect the end of the Distribution Cable Harness to Figure 3. End view of Distribution Cable Harness detailing available pinout connections.

Figure 5. Side view of receptacle-plug connection removal. ADDITIONAL INFORMATION Refer to these other user s manuals for more details : GEH-5934 MicroVersaTrip Plus and MicroVersaTrip PM Trip Units in Spectra RMS Molded- Case Circuit Breakers GEH-700 Spectra G Breaker w/ microentelliguard Trip Unit GEH-701 Spectra G Breaker w/ microentelliguard Trip Unit GEH-702 microentelliguard Trip Unit Users Manual DEH-41318 Universal Rating Plug GEH-6250 Voltage Module GEH-6251 Power Supply Plate GEH-6252 Voltage Conditioner Plate GEH-6253 Power Supply Assembly GEH-6254 Voltage Conditioner Assembly GEH-703 MET Battery Pack Adapter GEH-704 MET Advanced Distribution Cable Junction Box DEH-006 Distribution Cable Junction Box GEH-705 MET Distribution Cable Extension (20-pin) GEH-6256 Distribution Cable Extension (12-pin) GEH-706 MET Distribution Cable Terminal Blocks (11 point & 22 point) GEH-6257 Distribution Cable Terminal Block (11 point) GEH-6491 POWER LEADER Modbus Concentrator GEH-6502 POWER LEADER PMCS 5.0 Network Architecture Guide GEH-707 MET Sealable Cover kits DEH-4568 GTU digital test kit (GTUTK20) GEH-5551 Shunt Trip and UVR instructions GEH-5593 Aux switch and bell alarm GEK-64467 TIM-1 Zone Selective Interlock Module

Notes

Notes

Spectra and MicroVersaTrip are registered trademarks and EntelliGuard and microentelliguard are trademarks of the General Electric Company. These instructions do not cover all details or variations in equipment nor do they provide for every possible contingency that may be met in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise that are not covered sufficiently for the purchaser s purposes, the matter should be referred to the GE Company. GE Energy 41 Woodford Avenue, Plainville, CT 06062 www.geelectrical.com 2011 General Electric Company imagination at work GEH-6255 Rev. 3 (11/11 M45)