POWER Wave XR Clean Sophisticated Reliable

Similar documents
Rotary Phase Converter Data Sheet

Petrochemical processing Ship Yards Oil Fields Irrigation

ALL PURPOSE CNC/HEAVY DUTY

North America Phase Converters & Electrical Supply

Pretest Module 24 Three-phase Service Entrance

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

201 S. Anaheim Blvd. Page No Anaheim, CA RULE NO. 2 DESCRIPTION OF SERVICE

MAGNETIC MOTOR STARTERS

SECTION MOTOR CONTROL

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

AIR COOLED RECTIFIER SPECIFICATION S-50-A

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

High Frequency SineWave Guardian TM

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

HVW701 HVAC Drive with By-Pass

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

CTi Automation - Phone: Fax: Web:

SAVE THESE INSTRUCTIONS

Application manual Dry type power factor correction capacitors

RLW. Reactors. mtecorp.com. Smaller, lighter protection. Power quality. Solved.

WARREN COUNTY, N.Y. M/E REFERENCE

MOTORTRONICS Solid State AC Motor Control

WELLS RURAL ELECTRIC COMPANY Adopted: March 1976 Revised: March 21, 2017 Reviewed: August 21, 1998 RULE NO. 2

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual

Starting of Induction Motors

Application Description

WARRANTY INFORMATION...

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

SECTION MOTOR CONTROLLERS

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

Generator Fire Safety: Generator assemblies should be located outside the building.

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Dry Type Distribution Transformers

1-3 MANUAL STARTERS EXERCISE OBJECTIVE. Examine and describe the operation of manual motor starters. DISCUSSION

MOTOR INSTALLATION. Knowledge of proper installation techniques is vital to the effective operation of a motor

SPECTRACOOL Slim Fit Air Conditioners (Surface-Mount Units Only) Quick Start Operation Guide

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

Chapter 5 FOUNDATION. 2010, The McGraw-Hill Companies, Inc. 2010, The McGraw-Hill Companies, Inc.

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL

More Power and Less Fuel with our Electrical Energy Systems. SHARING EXCELLENCE

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

PHASE PERFECT PHASE CONVERTERS OPERATION & INSTALLATION MANUAL PHASE TECHNOLOGIES, LLC

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1. UNIT 2 ELECTRICAL CIRCUITS...49 Introduction...49

Why is the Breaker Tripping?

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

Electric Motor Controls BOMA Pre-Quiz

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Owner s Manual. DC-DC Step Down Converter

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

Design Standard. Purpose: Design Standard:

Avanti J Series Centrifuges Preinstallation

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

A WORD ABOUT PROPER GROUNDING

Electrical Design/Build Guide

ALL PURPOSE CNC/HEAVY DUTY

HIGH PERFORMANCE INDUSTRIAL GRADE

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits

Exercise 1-3. Manual Starters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Direct-on-line (DOL) starters. Reversing starters

Standby Power Systems

Welcome. Yaskawa Training Café Through the Combined Efforts of Drives Engineering and Technical Training Services

TECH XP125 INSTALLATION AND OPERATION MANUAL.

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

Diesel generator set 4BT3.3 series engine

Devices for Branch Circuits and Feeders

Motor Branch Circuit Over-Current Protection

Static Phase Converters Rotary Phase Converters Double-Throw Switches Fused Disconnect Double-Throw Switches Non-Fused Disconnect Switches Stray

825-P Modular Protection System for motors Specification Guide

Power System Solutions (PSS)

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

STEP Motor Control Centers

BLACKBIRD WIRING MANUAL

PREVIEW ONLY - FULL COPY AVAILABLE TO CONSORTIUM MEMBERS. Escalator Specific Electrical Systems. Course 209 PARTICIPANT GUIDE

Electrical Motor Controls Chapter 4 (Fourth Edition) Chapter 2 (Fifth Edition)

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Preinstallation Requirements for Avanti J Series Centrifuges

TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

The Power of Reliability INSTRUCTION MANUAL

Diesel generator set QSK23 series engine

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Owner's/Installation Manual

PT Series Phase Converters OPERATION & INSTALLATION MANUAL

RVS-AX Instruction Manual

3000W PowerVerter RV Inverter/Charger with Hardwire Input/Output

A6Z OPERATING MANUAL

Transcription:

POWER Wave XR Clean Sophisticated Reliable Through many hundreds of hours of research and design optimization, TEMCo is proud to offer POWER Wave XR ; a new breed of Phase Conversion technology. Based on many years of experience in the industrial power conversion industry, TEMCo has melded all of the best of each of the available tools in its technological arsenal to provide a new and unique approach to this fundamental need. Engineered to meet the rigorous requirements of the most demanding three phase machines, TEMCo s POWER Wave technology is a signature feature found only on TEMCo phase converters. POWER Wave produces a three phase sinusoidal waveform, generated from a single phase source, offset at 120, which smoothly alternates the voltage and current of AC (alternating current) power without harmonic distortion. It implements precision rotor/winding tuning to produce its sinusoidal output. Many competing technologies produce harmonic distortion and unbalanced waveforms. Harmonic distortion can cause overheating, and reduce the lifespan of the machinery attached to this type of converter. POWER Wave technology eliminates this problem. The sky is the limit with POWER Wave. With its versatility it can power any type of three phase machinery, ranging from Miller welders and Hobart mixers, to Hurco machining centers and Yamaha robotics. TEMCo is on the forefront of phase converter technology and continues to innovate and provide products that produce superior quality power. When you demand the best, demand TEMCo. Common Phase Converter Applications: Machine Shops Woodworking Farm Equipment Restaurant Equipment Petrochemicals Home Hobbyist Oil Fields Irrigation High Tech Military Aerospace Hospitals Make Your Money Work for You not Against You You know your business and how to make it make you money. Why purchase a solution with a limited lifespan without heavy maintenance? The TEMCo POWER Wave XR Phase Converter line has been engineered to eliminate the cost of long term maintenance. Of course none of this means anything without a guarantee It comes with a 5 Year Warranty Now that s Quality

POWER Wave XR Features 100% Copper Windings (Energy Efficient, Environmentally Friendly) American Design & Assembly Rugged Heavy Duty Rotary Design Industry Leading 5 Year Warranty Quiet Operation, 63db @ 10ft (No Louder Than Normal Conversation) 100% Satisfaction Guarantee* TEMCo Opto Sense 80 Point Quality Inspection System. A multitude of tests such as fastener torque check, vibration band analysis, full spec electrical and more are performed on every unit prior to being released from manufacturing. Designed for CNC First Not as an Afterthought. TEMCo was one of the first to provide a single to three phase power conversion solution for CNC Equipment users. In fact, TEMCo is the only company to offer a 100% Satisfaction Guarantee* backing the POWER Wave Phase Converter Line for the operation of ANY CNC machine! Unique Design Approach to Connections TEMCo uses the simplest and fastest connections systems in the industry. Save time during installation through clearly marked, committed connections points for your single phase input, three phase output and grounding connections. Just insert each wire and tighten it down; it s that simple. * Ask your sales representative for details.

POWER Wave Phase Converter Sp 1-phase input voltage 230v (max devia on ±10%) 1-phase input frequency 60Hz 3-phase output voltage = Input voltage + 5% on T2 (non-loaded) 3-phase output frequency same as input 3-phase output voltage tolerance ± 5% 3-phase output phase angle 120 Temperature ra ng 40 C Ambient Ambient humidity <95% (non-condensing) Maximum al tude (de-rate.004% for each foot above 3300 above sea level Enclosure NEMA 1 Recommended for All General Electrical Loads YES Recommended for All CNC and Electronic Loads YES Required RVI Isolator RVI501 Recommended Starter MAG3 Output DELTA CNC & ELECTRONIC LOADS kw output 2.1 kw 3-phase Amp output 7.0 A RESISTIVE ELECTRICAL LOADS kw output 4.0 kw 3-phase Amp output 10.0 A INDUCTIVE ELECTRICAL LOADS kw output 2.8 kw 3-phase Amp output 9.0 A MOTOR LOADS Maximum Easy run or start HP 3.3 HP Maximum Medium run or start HP 2.5 HP Maximum Hard run or start HP 1.7 HP Maximum group load HP 3.8 HP RLA 1-phase input calculated based on three phase load x 1.732 Approx. 1-phase idle amps 4.0 A MCA 1-phase 12 A Min 1-phase fuse 15 A MOP 1-phase 20 A Recommended 1-phase wire size *(1) 14 AWG Recommended 3-phase wire size *(1) Based on load requirement 230v RLA Rated Load Amps MCA Minimum Circuit Amps MOP Maximum Overcurrent Protec n Inside USA (800) 613-2290 In onal (510) 490-2187 Fax (510) 490-1507 www.temcophaseconverter.com

POWER Wave Phase Converter Dimensions Approximate dimensions, given in inches. Model A B C D E F G H Ship Dim Ship Wt XR2 11.0 10.75 14.25 7.5 5.5 7/16 2.75 7.75 24Hx18Wx18D 106 Lbs XR3 11.0 10.75 14.25 7.5 5.5 7/16 2.75 7.75 24Hx18Wx18D 106 Lbs XR5 13.5 14 16.75 9.0 5.5 7/16 3.5 9 24Hx18Wx18D 160 Lbs XR7 13.5 15.5 16.75 9.0 5.5 7/16 3.5 9 24Hx18Wx18D 176 Lbs XR11 15 17 22.5 10 8.25 1/2 4.25 13 24Hx24Wx30D 336 lbs XR15 15 18.5 22.5 10 10 1/2 4.5 13 24Hx25Wx30D 362 Lbs XR21 18 21.5 24.5 11 11 1/2 5 15.5 24Hx27Wx30D 498 Lbs Inside USA (800) 613-2290 International (510) 490-2187 Fax (510) 490-1507 www.temcophaseconverter.com

Single Unit Operation Electrical Connection Diagram TEMCo CIRCUIT PROTECTION PANEL XR2 XR3 XR5 XR7 XR11 XR15 XR21 SL015 SL020 SL030 SL035 SL060 SL075 SL100 REQUIRED TEMCo RVI XR2 XR3 XR5 XR7 XR11 XR15 XR21 RVI501 RVI501 RVI502 RVI503 RVI504 RVI504 RVI521 Single Phase TEMCo MAG Starter, Fused Disconnect, or Circuit Breaker: Refer to technical specifications for sizing. For optimal protection, device setting(s) should be based on minimum requirements of three phase load converted to single phase (3 phase load amps x 1.732) but not lower than recommendation in technical specifications. Single phase supply conductors should be based on circuit protection rating as required by NEC. Three phase output conductors should be based on circuit protection rating as required by NEC and the requirement of the three phase load equipment. Three phase TEMCo MAG Starter, Fused Disconnect or Circuit Breaker. Refer to three phase load equipment specifications for sizing details. For Multiple Unit Operation: Single Phase Input Buss: Each unit should be brought on line separately to reduce system start up current and it s affect on the single phase line. Verify that all units wiring corresponds with one another. L1 connected to L1 etc. Three Phase Output Buss: Verify that all units wiring corresponds with one another. T2 connected to T2 etc.

Multiple Unit Operation Electrical Connection Diagram TEMCo CIRCUIT PROTECTION PANEL XR2 XR3 XR5 XR7 XR11 XR15 XR21 SL015 SL020 SL030 SL035 SL060 SL075 SL100 REQUIRED TEMCo RVI XR2 RVI501 XR3 RVI501 XR5 RVI502 XR7 RVI503 XR11 RVI504 XR15 RVI504 XR21 RVI521

Installation Notes: 1. These diagrams are not intended to replace or supersede any requirements of local, state or national electrical codes. 2. Use only protective dual element time delay fuses or a magnetic starter with thermal overloads that carry an amperage rating within the limits set by the technical specifications. 3. Before attempting first start up, verify that the single phase input of the TEMCo Phase Converter has been connected to protective dual element time delay fuses, circuit breakers or a magnetic starter with thermal overloads that carry an amperage rating within the limits set by the table in section 18.0 Overload Protection. Failure to connect the single phase input of the TEMCo Phase Converter to a specified overload protection device can cause permanent equipment damage and will void the TEMCo Phase Converter warranty. 4. Do not bolt the TEMCo Phase Converter directly to the floor. Greater life expectancy of the rotating assembly can be achieved if it is mounted to vibration isolation mounts or set on a rubber pad. Solid mounting can cause loosening of connections and hardware, and will amplify noise levels. TEMCo offers engineered Resilient Vibration Isolators for this purpose. Consult your sales associate for supply of these at (510) 490 2187. 5. No load voltage on the three phase output from T1 T2 or T3 T2 will exceed T1 T3 by 5% (T2 on the output is the generated line). Voltages will balance when a load is applied. 6. Do not connect control circuits which require ground or neutral to the generated line T2 on the three phase output. This TEMCo Phase Converter provides a three phase DELTA output. On the output, voltage from T2 (generated line) to ground / neutral will be 180 220V on a 208 240V system. If a WYE (or 4 wire) three phase output is required, a three phase DELTA to WYE transformer is required. Please consult your sales representative for the supply of this type of transformer. 7. This TEMCo Phase Converter must always be started before any load is applied Loads include non loaded three phase transformers which constitute a small inductive load. 8. All loads must be turned off in the event of a power failure to prevent the TEMCo Phase Converter from being restarted under load when the power comes back on. Equipping three phase loads with magnetic starters is recommended. A magnetic starter will automatically shut off equipment if power is lost, thus protecting the TEMCo Phase Converter from starting under load when power is restored. 9. If automatic load starting is desired, a timer relay may used in conjunction with your load starting contactor to engage the TEMCo Phase Converter s output and should be set to an interval of approximately double the start up time as indicated in section 5.0 General Technical Specifications. 10. As many TEMCo POWER Wave Phase Converters as are needed to suit your application may be connected in parallel for increased output provided that your single phase branch circuit is capable of supporting the load. It is recommended that each unit be started independently to reduce single phase supply line loading during TEMCo Phase Converter start up. See section 12.0 Installation Electrical Diagram for further details.