Heavy Duty Industrial Foot Switches

Similar documents
CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Electromagnetic Particle Clutches and Brakes Models: POC, PHC-R, PMC-A3, POB, PRB and PTB-BL3 P Performance Manual

ERD Electrically Released Brakes

Warner Electric UNIBRAKE Motor Brakes

12 Volt Utility Controller for 4, 6 or 8 Brakes No P

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Preassembled Clutch/Electrically Released Brake Module

SFP-250 and SFP-400. Installation Instructions. An Altra Industrial Motion Company P-231-WE

Electromagnetic Particle Brakes Model: PRB-H

Safety Sentry Electronic Breakaway Switch

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

MTB II Modular Tension Brakes

AT Clutch Major Service Sizes 25, 55, 115

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB Size 50, 100, 180

Preassembled Clutch/Brake Module

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Compressor Clutch Replacement Procedure

Procedure to Install the New Autogap components in ER-1225 and ER825 Brake with inverted Armature Hub

Primary Brake Spline Drive Armature PB-825, PB-1000, PB-1225, PB-1525

TB Series Brakes Tension Control System

Utility Controller Hand Air Operated

Wrap Spring Clutches & Brakes CB & Super CB Series P-2026-WE SM592-gb-02/08

12 Volt Utility Controller for 4, 6, or 8 Brakes No

12-1/4 x 3-1/2 Electric Wheel Brake

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

Preassembled Clutch/Electrically Released Brake Module

Compressor Clutch Replacement Procedure

Electro-Brake 375, 475, 650, 825, 1000, 1225

Installation Instructions

Installation & Operation Manual. Electrak 1 Series / Electromechanical Linear Actuators Limit Switch, & Potentiometer Feedback, and Long Life Models

Pneumatic Single Disc and Dual Disc Brakes P250 and P620

Gen 2 Clutch/Brake UniModule UM-50, UM-100, UM-180

Electromagnetic Toothed Clutch E330

Installation Instructions

Service & Installation Instructions. An Altra Industrial Motion Company P WE Vented. Enclosed Version Optional

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

Advanced Technology Tension Clutches

PB-500 Pin Drive, PB-500 Spline Drive PB-650 Pin Drive

A30 Single Range Tensioncells

Hydraulic Multi-Disc Brake H420 P-2067-WE SM320gb - rev 02/09

Primary Brakes PB-120, PB-170, PB-250, PB-400

Installation Instructions

Electro-Packs EP-170, 250, 400, 500, 825, 1000, 1525

Electrically Released Brakes FB-375, 475, 650

SFC-825, SFC-1000, SFC-1225, SFC-1525 Heavy Duty Clutch Coupling and SFC-1525 High Torque Heavy Duty Clutch Coupling

Hydraulic Multidisc Clutch H 110 VAR00 P-2066-WE SM301gb - rev 02/09

Linear Actuators P-6150-WL

Residential, TG-2000 and Commercial MagStop Clutch/Brake

Electrically Released Brakes FB-375, 475, 650

Blade Brake Clutch Application Guide P

Electro-Module EM-50, EM-100, EM-180, EM-210, EM-215

Pro-Series/ Electromechanical Linear Actuator

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

BULLETIN 2212 P Installation Instructions. thru 1027

Fan Backstop Clutches Models HFB & VFB

Special Purpose Overrunning Clutches ep 300 thru 1027 (less Oil Seals)

BMRX Series ROTARY LEVEL CONTROL

Component Size Weight Capacity

PVI 60KW, PVI 82KW, PVI 95KW

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

SOLAR DASH CHARGING SYSTEM USER GUIDE

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Model C230 Pump Controller

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

For a 25 Amp Circuit with a 10% Voltage Drop, we recommend the following [but please follow all local electrical codes]: 50 [15.2] 8 [8.

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

INVERTER HARNESS INSTALLATION FOR FREIGHTLINER CASCADIA

Installation Precautions. Use Precautions. Specifications

Users Guide for Ac-sync

EAGL 1-Touch Laser Level

Installation Manual for the SHURflo LCB - G Pump Controller

INW Panel Meter Reading an INW PT12 Sensor

GRADE 3 TUBULAR LOCKSETS INDEX:

60 PSI Boost Gauge. For Product Numbers: MT-DV01_60, MT-WDV01_60

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

SELECT/DIRECT DEMO BOX USER GUIDE. INST164 Doc 1.00

INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INFORMATION

Adjustable Shop Stool with Backrest

Installation Instructions PART NUMBERS: 76192, 84192, CQT76192

6 OFF ROAD LIGHT BAR


PLEASE ENSURE THE JUMP STARTER IS FULLY CHARGED PRIOR TO FIRST USE.

Size 15 thru 29 Mesur-Fil Fluid Couplings P

END USER TERMS OF USE

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

SERIES 1000 ELECTRIC ACTUATORS

Installation / Operation Instructions Sunnex ORION Series Exam Lights

HE1U 1248 BMS High Efficiency 1U AC to DC Power Supply Owners Guide SPECIFICATIONS

Heavy-Duty Drywall Dolly Cart

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

USER S OPERATING AND INSTRUCTION MANUAL

Model:M5B/M5W/M5N. Installation Guide. Specifications Desktop Weight Capacity Keyboard Tray Weight Capacity Height Adjustable Range

INSTALLATION AND OPERATION MANUAL

Instruction Sheet. SFR Series. Swing Frame rack

Adjustable Steel Welding Table

Transcription:

P-1303 819-0523 Heavy Duty Industrial Foot Switches Installation Instructions

Failure to follow these instructions may result in product damage, equipment damage, and serious or fatal injury to personnel. Explanation of Model Identification Code for Foot Switches Number of Pedals Dash Contact Block Function Dash Additional Features F1 = One Pedal Foot Switch F2 = Two Pedal Foot Switch U1 = SU1 = U2 = SU2 = 1 NO / 1NC Single Pole Break Before Make Momentary 1NO / 1NC Single Pole Momentary 2 NO / 2 NC Double Pole Break Before Make Momentary 2 NO / 2NC Double Pole Momentary Z = Y = D = AT = UN = (example U1Z) indicates a forced disconnect of the Normally Closed Contacts. (example U1Y) indicates a maintained contact. 1st depression of pedal latches switch on 2nd depression releases. (example U2D) indicates a pressure point for operation with 2 contact blocks, 2 stage operation. 1st block operates up to pressure point, 2nd block operates after operation of pressure point switch. (example SU1Z AT) indicates an Anti-Trip Device. A lever must be pushed forward with a foot before the pedal can be pressed. (example F1-U1Z UN) indicates a Protective Guard over the pedal. F3 = Three Pedal Foot Switch NO = Normally Open NC = Normally Closed Mi RG = AP = (example SU1 Mi RG) indicates a proportional output, fitted as standard is a varible resistor, 10K ohms, 2W. (example F1-U1 AP) Explosive proof switch for operation in medical areas surgically safe. Multi Pedal Switches: With multi-pedal switches, it is possible for each pedal to have its own function. The functions available are explained in the Contact Block Function area of the Identification Code. 2 Warner Electric 800-825-9050 819-0523

Note: Special function and combinations of foot switches can be designed and manufactured to meet the customer s own design performance and requirements. For information consult the Sales Office at 1-800-451-8279. Ordering Example: The following order has to be observed. 1. The type of desired device by number of pedals. Example: F1, F2, F3 Specification Overview Mechanical Features: Case Material Protective Guard Actuator Ambient Air Temperature Switch Action Aluminum die cast Aluminum die cast Foot Lever -22ºF to 176ºF Dependent upon switch selected 2. The number and type of contact block. For switches with several pedals indicate from left to right. Example: F3-U1/U1Y/U2D UN 3. The indications concerning additional functions, versions or pedals have to be given in the description, directly behind the corresponding switching element. Example with detent detent and pressure point: F3-U1/U1Y/U2D UN 4. Indciations on special equipment which does not depend on the pedal have to be given at the end of the type designation. Example: F2-U1/U1 AP 5. Versions with proection shield are marked at the end of the type designation by UN. Example: F2-U1/U1 AP UN Contacts Mechanical Life Switching Frequency Mounting Terminals Cable Entries Weight Dependent upon switch selected 10 x 10 6 Switch Operations 50 times per minute Free standing on rubber bumpers 4 screw terminals per contact block All switches supplied with a 1/2 inch Conduit Adapter Approximate: Without Guards F1 1.5 lbs. (.7 kg) F2 3.7 lbs. (1.7 kg) F3 6.8 lbs. (3.1 kg) With Guards F1 3.3 lbs. (1.0 kg) F2 5.7 lbs. (2.6 kg) F3 11.9 lbs. (5.9 kg) Electrical Features: Maximum Voltage Enduring Current 500 VAC 20 AMPS Inrush Current Per IEC 947-5-1, AC 15, DC 13 Standards Protection Class UL / CSA Approved According to VDE 0660, 0113, IEC 947-5-1 NEMA 4, IP65 According to DIN 40 050 10 AMP, 300 VAC, A300 (Same Polarity) Warner Electric 800-825-9050 819-0523 3

Assembly Instructions To assemble either the top safety cover or the protective shield onto the foot switch set it at a right-angle (90º) to the base and then swivel down. It is important to ensre the rubber seal and cover is seated correctly. The cover should be hand tightened (Max. 5Nm / 3.7 ft. lb.). Over tightening will dambage the seal. Hazardous Applications Do not use foot switches on machines without point-of-operation protection. Failure to observe this warning can result in serious injury or death. Point of Operation - The point or area of the machine or equipment where the work piece or material is actually positioned and work is being performed during any process. Foot switches are used to control many industrial procccesses, while leaving the operator s hands free to perform other functions. The type or model of foot switch suitable for each application will veary depending on factors such as the control function required, degree of protection required, production methods, unusual conditions, government regulations, etc. Only the user can be aware of all the conditions and factors present during setup, operation and maintenance of the machine; therefore, only the user can determine which foot switch or switches can be properly used. When selecting a foot switch for a particular application, the user should refer to the application ANSI standards and OSHA regulations. 4 Warner Electric 800-825-9050 819-0523

Foot Switch Model/Function Identification Code Product # of Pedals (Dash) Contact Block Function + Additional Features Designation Model/Type F1 ** One Pedal Foot Switch F2 ** Two Pedal Foot Switch F3 ** Three Pedal Foot Switch FG ** Heavy Pedal Foot Switch Multi Pedal Switches With multi-pedal switches, it is possible for each pedal to have its own function. This explanation for each function is contained in the Model/Function Identification Code as indicated below. F2 Left Pedal Right Pedal Function + Features Function + Features Designation U1 F3 Left Pedal Middle Pedal Right Pedal Function + Features Function + Features Function + Features U2 SU1 SU2 SU1Z SU2Z *Special function and combinations of foot switches can be designed and manufactured to meet the customerís own design performance and requirements. For Information consult the Sentec Sales Office. Function Explanation 1 NO/1NC Brake Before Make 2 NO / 2 NC Break Before Make 1 NO / 1 NC 2 NO / 2 NC 1 NO / 1 NC with Positive Disconnect of NC 2 NO / 2 NC with Positive Disconnect of NC NO = Normally Open NC = Normally Closed Features Special Arrangements/Versions Y Switching Insert for On/Off lock system. 1st depression operates switch on, 2nd depression resets switch. D Pressure point for operation with 2 contact blocks, 2 stage operation. 1st block operates up to pressure point, 2nd block operates after operation of pressure point. UN AP NA UK FST MIRG LS22/ LS38 AT Protective guard/cover. Explosive proof switch for operation in medical areas Surgically Safe. Emergency push buttons Moveable guard, hinged shield. Shield must be lifted by foot prior to operation, for F1 types. Foot support for operator comfort for machinery with continuous operation, for F1 types. Proportional output, fitted as standard is a variable resistor, 10K ohms, 2W. Contactors can be mounted internally so the switch can directly power machinery, exact type need to be specified. Anti-trip device. Lever must be pushed forward with foot before pedal can be pressed. Warner Electric 800-825-9050 819-0523 5

Warranty Warner Electric LLC warrants that it will repair or replace (whichever it deems advisable) any product manufactured and sold by it which proves to be defective in material or workmanship within a period of one (1) year from the date of original purchase for consumer, commercial or industrial use. This warranty extends only to the original purchaser and is not transferable or assignable without Warner Electric LLC s prior consent. Warranty service can be obtained in the U.S.A. by returning any defective product, transportation charges prepaid, to the appropriate Warner Electric LLC factory. Additional warranty information may be obtained by writing the Customer Satisfaction Department, Warner Electric LLC, 449 Gardner Street, South Beloit, Illinois 61080, or by calling 815-389-3771. A purchase receipt or other proof of original purchase will be required before warranty service is rendered. If found defective under the terms of this warranty, repair or replacement will be made, without charge, together with a refund for transportation costs. If found not to be defective, you will be notified and, with your consent, the item will be repaired or replaced and returned to you at your expense. This warranty covers normal use and does not cover damage or defect which results from alteration, accident, neglect, or improper installation, operation, or maintenance. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you. Warner Electric LLC s obligation under this warranty is limited to the repair or replacement of the defective product and in no event shall Warner Electric LLC be liable for consequential, indirect, or incidental damages of any kind incurred by reason of the manufacture, sale or use of any defective product. Warner Electric LLC neither assumes nor authorizes any other person to give any other warranty or to assume any other obligation or liability on its behalf. WITH RESPECT TO CONSUMER USE OF THE PRODUCT, ANY IMPLIED WARRANTIES WHICH THE CONSUMER MAY HAVE ARE LIMITED IN DURATION TO ONE YEAR FROM THE DATE OF ORIGINAL CONSUMER PURCHASE. WITH RESPECT TO COMMERCIAL AND INDUSTRIAL USES OF THE PRODUCT, THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES, WHETHER EXPRESSED OR IMPLIED BY OPERATION OF LAW OR OTHERWISE, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Changes in Dimensions and Specifications All dimensions and specifications shown in Warner Electric catalogs are subject to change without notice. Weights do not include weight of boxing for shipment. Certified prints will be furnished without charge on request to Warner Electric. Warner Electric LLC 449 Gardner Street South Beloit, IL 61080 815-389-3771 Fax: 815-389-2582 www.warnerelectric.com P-1303 819-0523 4/06 Printed in USA