POLYPROPYLENE PUMP TUBE SP-PP SERIES * * * 0 * V-seal - Viton Pump coupling Drive shaft, " (00 mm) Discharge housing Bearing unit assembled - each Viton shielded bearings, spacer, snap ring, bearing can Hose barb, /" ( mm) " ( mm) Wing nut Snap ring Guide sleeve - TFE ", ", " 0", " Pump housing includes carbon bushing Inner tube, Outer tube, " (00 mm) " (00 mm) Impeller High pressure impeller Pump foot High pressure pump foot Hand wheel 000 00 00 00 00 0 0 0 0 0 0 00 0 0 0 0 0 0 0 HH 0 0 HH * Parts interchange with all pump tubes. Polypropylene pumps should not be used to pump flammables.
CPVC PUMP TUBE SP-CPVC SERIES * * * 0 * V-seal - TFE Pump coupling Drive shaft " (00 mm) Discharge housing Bearing unit assembled - each Viton shielded bearings, spacer, snap ring, bearing can Hose barb, /" ( mm) " ( mm) Wing nut Snap ring Guide sleeve - TFE ", ", " 0", " Pump housing includes carbon bushing Inner tube, Outer tube, " (00 mm) " (00 mm) Impeller High pressure impeller Pump foot High pressure pump foot Hand wheel 000 00 0 0 0 0 0 0 00 0 0 0 0 0 0 0 HH 0 0 HH * Parts interchange with all pump tubes. CPVC pumps should not be used to pump flammables.
HIGH TEMPERATURE PUMP TUBE SP-PHT SERIES * * * 0 * V-seal - TFE Pump coupling Drive shaft " (00 mm) Discharge housing Bearing unit assembled - each Viton shielded bearings, spacer, snap ring, bearing can Hose barb, /" ( mm) " ( mm) Wing nut Snap ring Guide sleeve - TFE ", ", " 0", " Pump housing includes carbon bushing Inner tube, Outer tube, " (00 mm) " (00 mm) Impeller High pressure impeller Pump foot High pressure pump foot Hand wheel 000 00 0 0 0 0 0 0 00 0 0 0 0 0 0 0 HH 0 0 HH * Parts interchange with all pump tubes. Polypropylene pumps should not be used to pump flammables.
PVDF PUMP TUBE SP-PVDF SERIES * * * * 0 Pump coupling Drive shaft Bearing unit assembled - each Viton shielded bearings, spacer, snap ring, bearing can Snap ring Guide sleeve - TFE ", ", " Hand wheel V-seal - TFE Discharge housing Hose barb, Wing nut Inner tube, Outer tube, /" ( mm) " ( mm) Pump housing includes carbon bushing Impeller - PVDF High pressure rotor Pump foot High pressure pump foot 00 0 0 000 0 0 0 0 00 0 0 0 0 0 0 0 0HH 0 0HH * Parts interchange with all pump tubes. PVDF pumps should not be used to pump flammables.
STAINLESS STEEL PUMP TUBE SP-SS SERIES * * * * 0 Pump coupling Bearing unit assembled each Viton shielded bearings, spacer, snap ring, bearing can Snap ring Hand wheel Connection flange Drive shaft " (00 mm) TFE guide sleeve / " (00 mm) Wing nut TFE seal Hose barb, " ( mm) Inner/outer tube assembly " (00 mm) Pump housing with carbon bushing TFE impeller High pressure impeller 'O'-ring, Viton, per set Pump foot High pressure pump foot V-Seal - TFE 00 0 0 000 0 0 0 0 0 0 0 0 00 0 0 0 0 0 HH 0 0 0 HH 000 * Parts interchange with all pump tubes. Read and understand operating and safety instructions before operating any Standard Pump.
AIR MOTOR SP-A 0 Muffler Gasket Dead end cap Bearing ( req'd) Dead end plate Gasket ( req'd) Body Drive end plate Shaft seal Vane ( req'd) Dowel pin ( req'd) Impeller Repair Kit* Includes item numbers,,, and 0. A adapter (not shown) SAF0 SAC SACA SAG SAC SAC SAE SAC SAC0A SAE SDA SAE SK 00 * Items not sold separately. Item sold as part of repair kit, item. Read and understand operating and safety instructions before operating any Standard Pump.
NOTE: Part Numbers and 0 are not shown AIR MOTOR SP-A A 0 A 0 Motor housing Trigger assembly repair kit (includes items -) Trigger Throttle valve assembly Throttle valve seal Throttle valve spring Throttle valve body assembly Valve body seal Valve body seal Valve body retaining pin Speed regulator repair kit (includes items -) Speed regulator assembly Regulator seal ( req'd) Regulator retainer Inlet bushing Rear impeller bearing Rear impeller repair kit (includes items & A) Rear end plate assembly Dowel (end plate) Cylinder repair kit (includes items & ) Cylinder assembly Dowel (cylinder) Impeller Vane packet () Impeller spacer Front end plate Front impeller bearing Motor locknut Muffler (not shown) Motor coupling (not shown) A adapter (not shown) S-0 S-00 S- S-A0 S-0 S- S-A0 S0- S0- S-0 S-0 S-A S0- S- S- S- S-0 S-A S0- S-0 S-A S0- S- S-- S- S- S- S- SAF0 0 Read and understand operating and safety instructions before operating any Standard Pump.
OPEN DRIP PROOF MOTOR SP-0P SERIES SP-0P open motor should not be used to pump flammables. *Parts interchange with all Standard electric motors * A* B* * * * * * 0* * * * * * * 0 * * * Motor cover Switch housing Switch housing for variable speed includes potentiometer V Switch housing for batch control includes potentiometer and BCS port connection V Switch cover Lock washer Lower housing Wave washer Ball bearing Screw for plastic housing Screw Ground screw Gasket low voltage release (for ) Earthing lead Lead Screw Ball bearing Motor coupling Power cord w/strain relief & plug V Hexagon nut Armature Stator V V Guide disc Rod connector Pressure spring Brush holder Carbon brush V Motor housing, plastic Star washer Fan Overload switch,. amp V amp low voltage release 000 00 00 00 00 00 00 0 00 0P LVR 0 0 0 0 0 0 0 0 0 0 0 0 0 0P 0LVR 0
OPEN DRIP PROOF MOTOR SP-ODP SERIES SP-ODP open motor should not be used to pump flammables. * * Motor assembly Overload switch. amp, V amp, Motor coupling Case right Actuator switch ( req'd.) Pin rocker switch Case left Screw # x ½ L pan head Plastite ( req'd.) Power cord w/strain V relief & plug 00 0 LVR 0 0 0 0 0 0 *Parts interchange with all Standard electric motors
TEFC MOTOR SP-ENC SERIES SP-ENC motor should not be used to pump flammables. *Parts interchange with all Standard electric motors * A* B* 0* * * * * * * * 0 * * * * * * * 0* Motor cover Screw Armature Stator V V Guide disc Motor housing Bearing cover Fan Switch housing Switch housing for variable speed includes potentiometer V Switch housing for batch control includes potentiometer and BCS port connection V Switch cover Lock washer Lower housing Wave washer Ball bearing Screw Screw Ground screw Gasket Low voltage release (for ) Earthing lead Lead Screw Ball bearing Motor coupling Power cord w/strain relief & plug V Hexagon nut Rod connector Brush holder Carbon brush, V Star washer Overload switch,. amp V amp low voltage release 000 0 0 0 0 0 0 0 00 00 00 00 00 00 0 00 0 LVR 0 0 0 0 0 0 0 0LVR
EXPLOSION-PROOF MOTOR SP-00- SERIES FRONT VIEW 0 0 0 BACK (HANDLE) VIEW TOP VIEW 0 0 0 Fan cover Bearing cover Wave washer ( req'd) Glass sleeve Motor housing Lower housing Motor coupling Stator 0V Armature 0V Switch housing Ground connector Set screw Cord without plug Strain relief Handle Cord clamp Pass through ( req'd) Switch On / Off knob Connector terminal Fan Switch handle screw ( req'd) Switch housing screw ( req'd) Motor bolt nut ( req'd) Switch housing washer ( req'd) Motor bolt washer ( req'd) Brush holder Rod connector ( req'd) Ball bearing ( req'd) Carbon brush ( req'd) Switch bracket Switch actuator Switch bracket screw ( req'd) Switch actuator pin Brush tab screw ( req'd) Brush tab ( req'd) Fan cover screw ( req'd) Fan cover screw washer ( req'd) Motor bolt ( req'd) 0 00 00 00 00 0 00 00-0 0-EXP 0-00 00 0 0LVR 0???? 00 0 0 0 0-0 0-0 0 0-0 0 0 0 00 0-0 0 0-0- 0-0 0-0 0-0
SECTION : TRANSFERRING OF FLAMMABLES OR USE IN HAZARDOUS DUTY ENVIRONMENTS Bonding is an electrical connection between a primary metal vessel and a metal receiving vessel. See schematic. Grounding is an electrical connection between a metal vessel, pump, motor and a constant ground; i.e. a metal rod driven into the earth. Bonding and grounding are required when pumping flammable materials or in hazardous duty environments. Failure to bond and ground properly can cause a discharge of static electricity resulting in fire, injury or death. Follow NFPA and 0 procedures at all times. If in doubt, do not start pump! Be sure bonding and grounding wires are secure before starting operation. (Ground and bond wires must have less than one ohm resistance for safe usage. Check continuity before starting.) Always check with a safety engineer when any question arises and periodically check safety procedures with a safety engineer. Ground wire Motor: Explosion-Proof Pump Tube: SP-SS Optionals: Solvent resistant safety hose with wire ground Rod Metal drum Bond wire Metal drum No splashing Earth ground Ground wire Air line Muffler Air Motor: SP-A or SP-A Pump Tube: SP-SS Optionals: Solvent resistant safety hose with wire ground Rod Metal drum Bond wire Metal drum No splashing Earth ground
Declarations Declaration of Conformity Declaration of Incorporation When this unit is used as a stand alone unit it complies with: Machinery Directive //EC EN00, EN0--, EN0-, Low Voltage Directive //Eec EN00-, EMC Directive //Eec EN0, EN 00, EN00-, EN00- When this pump unit is to be installed into machine or is to be assembled with other machines for installations, it must not be put into service until the relevant machinery has been declared in conformity with Machine Directive //EC EN00, EN0--, EN0-. Responsible person: Donald M. Murphy, Managing Director, Standard Pump, Inc., 0 Industrial Way, Snellville, GA 00, USA. Ph: 00-0--, Fax: 00-0--, e-mail: info@standardpump.com Three year warranty Standard Pump, Inc. warrants, subject to the conditions below, through either Standard Pump, Inc., it s subsidiaries, or its authorized distributors, to repair or replace free of charge, including labor, any part of this equipment which fails within three years of delivery of the product to the end user. Such failure must have occurred because of defect in material or workmanship and not as a result of operation of the equipment other than in accordance with the instructions given in this material. Specific exceptions include: consumable items such as motor brushes, bearings, couplings and impellers. Conditions of exceptions include: Equipment must be returned by prepaid carriage to Standard Pump, Inc., its subsidiary or authorized distributor. All repairs, modifications must have been made by or with express written permission by Standard Pump, Inc., it s subsidiary or authorized distributor. Equipment which have been abused, misused, or subject to malicious or accidental damage or electrical surge are excluded. Warranties purporting to be on behalf of Standard Pump, Inc. made by any person, including representatives of Standard Pump, Inc, its subsidiaries, or its distributors, which do not fall within the terms of this warranty shall not be binding upon Standard Pump, Inc. unless expressly approved in writing by a Director or Manager of Standard Pump, Inc. Information for returning pumps Equipment which has been contaminated with, or exposed to, bodily fluids, toxic chemicals or any other substance hazardous to health must be decontaminated before it is returned to Standard Pump, Inc, or its distributor. A returned goods authorization number (RGA #) issued by Standard Pump, Inc., its subsidiary or authorized distributor, must be included with the returned equipment. The RGA # is required if the equipment has been used. If the equipment has been used, the fluids that have been in contact with the pump and the cleaning procedure must be specified along with a statement that the equipment has been decontaminated.