CEGA FORANO BY GREGGERSEN

Similar documents
CEGA SYSTEMS BY GREGGERSEN

MEDICAL DEVICES BY GREGGERSEN

Installation and Maintenance Manual. Medical Gas Outlet. British Standard Compatible

Installation and Maintenance Manual. Medical Gas Outlet. British Standard Slim Style Compatible

PRECISION UK Ltd. Medical Gas Outlet BS Standard

Technical Datasheet. SP Terminal Units. Classification. Services. Terminal Block. Check Valve Assembly. Tailpipe Options

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Axis MEDICAL GAS TERMINAL UNITS

FLEXIBLE PENDANTS with Axis MEDICAL GAS TERMINAL UNITS

Fuel Oil Deaerator with Integrated Filter Type GS 2000

PRECISION UK Ltd DUPLEX AGSS PLANT

Axis AGSS TERMINAL UNITS

Technical Specification

At Amico Labs we are dedicated to continued growth while producing products of outstanding quality, and providing excellent service.

KLINGER BALLOSTAR KHE 2-piece ball valves DN (1/2" 8")

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

KLINGER BALLOSTAR KHE

DISPOSITIVI, SISTEMI E IMPIANTI PER L EVACUAZIONE DEI GAS ANESTETICI DEVICES, SYSTEMS AND PIPELINE SYSTEMS FOR ANAESTHETIC GAS SCAVENGING

MEDICAL GAS OUTLETS. l DIN l BS 5682:1998 l BS 8532:2011. l SS l AFNOR NF S / FD S l AS 2896 l JIS T 7101

Angle seat valve with piston actuator VZXA-...-K

Installation and Operating Manual CONTENT

Angle seat valve with diaphragm actuator VZXA-...-M

Ball valves and shut off valves

Installation and Operating Instructions DDM-DS11 DDM-DS11-MS1 DDM-DS11-MS2

Ball valve C 10 valve ball completely moulded in place, extremely low clearance volume, high k v value

Butterfly valves PN6, PN10, PN16

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Direct-acting 3/2 way plunger valve

AirLINE and AirLINE Quick electrical/pneumatic Automation System

Direct-acting 2/2-way plunger valve

2018 High Performance Check Valves for liquid and gaseous media

RIGID PENDANT. Phoenix Pipeline Products Limited. Installation, Operation and Maintenance Manual

MEDICAL GAS OUTLETS. Medical

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

ADJUSTED TO SITUATION AND SPACE

3/2-way Solenoid Valve, direct-acting, NC or NO

3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base

Butterfly valves, PN6, PN10, PN16

Angle seat valve with piston actuator VZXA-...-K

3/2-way Solenoid Valve for pneumatics

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Ball valve C 100 multi-part, high k v value, high stability

Gas pressure regulator R 100 / R 100U / R 100UD

NAF-Setball ball sector valves DN , PN 10-40, ANSI Class Fk 41.51(15)GB 03.10

DEUTROFLUX UWE Universal Stationary Magnetic Particle Crack Detectors

Richter Ball Control Valves Torque transmission free of play

Richter Ball Control Valves Torque transmission free of play

Front panel valves SV

INOX PrOgram made by eisele

Application Pressure reducing valves for the food and pharmaceutical industries

Diaphragm Valve MV pneumatic - with pneumatically directly controlled actuator

RTM3 OXYGEN-THERAPY FLOWMETERS WITH FLOATING BALL

Oriflow. Compact Orifice with HART communication. Operating instructions. A-EN RevC Latest Mod von 16

Pressure relief valve DHV 712-R set range: 0,3-10,0 bar

Safety Shut-Off Valve HON 711 S2

3/2-way and 2 x 3/2-way Rocker Solenoid Valve for pneumatics

High-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP

Richter Ball Control Valves Torque transmission free of play

Solenoid valves VZWM-L, NPT

GENO -MX 1" - MX DN 100 backwash filter. Intended use. Scope of supply. Function. Structure

Operating Instructions. International English. CCS Dust Extractor

EISELE LIQUIDLINE PROGRAM CONNECTIONS FOR COOLING WATER

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Series 02: DN40 and DN50 Series 01: DN Three-port slipper valves PN6

Three-port slipper valves PN10, female-threaded

Ball valve C 100 multi-part, high k v value, high stability

Ball Valve C 200. Stem PVC-U PVDF PP, fiberglass-reinforced. Ball PVC-U PP PVDF. Ball Seat PTFE. Application chemical and industrial plants

VKF41...C. Butterfly Valves. Building Technologies Division Industry Sector

Pressure sensor for liquid and gaseous media QBE620-P...

Angle Seat Valve /2" up to 3"

trak systemizer Turnkey charging & changing stations

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Combination angle valve with filter and angle valve with filter. By SCHELL.

Catalog. Accessories Separ-Filter. Catalog: Accessories Separ-Filter Page 1 of 13

Brief Overview 2018 WEH CONNECTOR SOLUTIONS for pressure-tight connections in seconds WEH Q UA LIT Y. since 1973

Operating Instructions

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

3- and 4-Way Ball Valves KH3/KH4

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics

Volume Control Dampers. Series HVC-VCD Aluminium volume control dampers. Incorporating. Excellent general purpose volume control damper

G4 Series. ...Extremely sensitive and accurate PILOT OPERATED PRESSURE REDUCING VALVES PRESSURE EQUIPMENT DIRECTIVE (PED) Adjusting Screw

Suction return line filter Pi 550

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

EISELE IS QUALITY MADE IN GERMANY AVAILABLE ON STOCK IN GRAND RAPIDS, MI

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Safety Shut-Off Valve HON 711

Pneumatic grease pump 50:1 and grease supply system

better measurement Simply a question of

Instruction Manual. Automatic Fuel Oil De-aerator Flow-Control. Flow-Control 3/K-1 # Flow-Control 3/K-2 # 70019

Contents. Identification

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

with pneumatic actuator Pneumatic process valve, Y-pattern DN ARI-STEVI AS 350 Pneumatic actuator - with screwed sockets

Messing. screw-in connectors

VBF21.. Three-port slipper valves PN6. Series 02: DN40 and DN50 Series 01: DN

2200 North Main Street Washington, PA PH: FX:

Vacuum Automation 2.1. The future depends on good product choices

Safety Shut-off Valve SL/SID/RSL

Transcription:

CEGA FORANO BY GREGGERSEN PRODUCT CATALOG FORANO

Terminal Unit According to DIN EN ISO 9170-1 GENERAL According to national and international standards, The unit is used to withdraw compressed gases and terminal units are the points that connect medical vacuum from a central medical gas supply system appliances to the gas supply system. The prize-winning in line with DIN EN ISO 7396-1; Anaesthetic Gas FORANO terminal units can be flexibly integrated Scavenging System in line with DIN EN ISO 7396-2; into every conceivable installation. Ease of handling integration of plugs and medical appliances with plug- guarantees smooth running in routine hospital in connections in line with DIN 13260-2. practice. Structure and functions Our Anaesthetic Gas Scavenging System controls the safe use of anaesthetic gases. Our Air-Motor system supplies the energy to drive your compressed airoperated tools. The terminal unit comprises a gas-specific basic block (rear part) and a connector mounting (front part) which are joined together. The front part can be adjusted (rotated). All movable parts are made of metal materials. The terminal unit thus in general has a very All three O-ring seals are combined in a maintenance- Labelling: Type of gas written out in German and low-wear construction. friendly way in an assembly the cartridge which can English plus chemical symbol (laser-inscribed in a easily be replaced by removing wipe-resistant and tamper-proof way). the front part. The cartridge is Colour coding: neutral or in line with DIN EN ISO 5359. marked with a LOT number so that the age of the sealing elements can be immediately identified. The plug in the connector mounting is kept either in the parking or the operating position. Design: pearl gloss, chrome-plated all-metal construction with parking and operating position; unlocking by means of the actuator; single-handed operation when connecting/disconnecting; manually lockable servicing valve. Types of installation: concealed and hollow wall installation, surface mounting, installation into bedhead units or into ceiling-mounted supply units. The terminal unit FORANO has won three of the world's most prestigious design awards and has been nominated for the 2010 Design Prize of the Federal Republic of Germany. 700 kpa to 1000 kpa (overpressure) Airmotor <60 kpa (absolute pressure) vacuum CEGA_for_02 CEGA_for_03

Terminal Unit INTELLIGENT CLOSING SYSTEM INTELLIGENT, SIMPLE, SECURE The terminal unit is the only medical gas outlet on the market with an intelligent closing system offering three closing functions: 1. It seals the terminal unit when the plug connector is disconnected. 3. The terminal unit can be shut off using a special key without dismantling the front part. The front part is then sealed with a warning sticker (art. no. 903.309) (see p. 5). Thus each terminal unit can be shut off individually, i STICKER Out of order! When shutting off a terminal unit or entire sections of the mains supply, the corresponding terminal units must be clearly marked. For this purpose, we offer you a sticker especially for the terminal unit to paste over the connector mounting. Please see page 18 / TOOLS AND ACCESSORIES 2. The front part of the terminal unit can be dismantled without interrupting the gas supply and the wear parts can be replaced. eliminating the need to shut off individual areas or entire wards of the hospital if servicing or repairs need to be performed. nicht in Betrieb! out of order! TEST KIT FOR TERMINAL UNIT SYSTEM FORANO in accordance with DIN EN ISO 7396-1/2 Consisting of: terminal unit in non-shutoff mode. The special tool with a centering aid to shut off the terminal unit is already inserted. After approx. 3-4 rotations, the rear part of the terminal unit is sealed gas-tight. Maintenance work, for example the replacement of the sealing cartridge or replacement of the entire front part, can be easily performed under operating pressure. Test block with flow pipe for compressed gases Test block with flow pipe for vacuum/ NGA/AGSS Air motor test device Leak tightness measurement device Particle test device Filter box Gas-specific plug connector in accordance AGSS testing device with panel for 25 L/min with DIN 13260: AGSS connection test kit according to DIN EN Connector for oxygen (O2) ISO 7396-2 Connector for compressed air (AIR) Testing device kit with insert Connector for vacuum (VAC) Optional accessories: Connector for carbon dioxide (CO2) - O2 meter for testing gas type Connector for nitrous oxide (N2O) - Pressure gauge for leakage testing of AGSS testing device with panel for 50 L/min the pipe line Test kit terminal unit in line with 7396-1/2 DIN 902.114 CEGA_for_04 CEGA_for_05

Terminal Unit DIN CONCEALED / HOLLOW WALL INSTALLATION Terminal Unit DIN CONCEALED / HOLLOW WALL INSTALLATION 222 mm The unit is used to withdraw compressed gases and vacuum from a central medical gas supply system in line with DIN EN ISO 7396-1; integration of plugs and medical appliances with plug-in connections in line with DIN 13260-2. The terminal unit complies with the requirements of DIN EN ISO 9170-1. The unit is used to withdraw compressed gases and vacuum from a central medical gas supply system in accordance with DIN EN ISO 7396-1; integration of plugs and medical appliances with plug-in connections in line with DIN 13260-2. The terminal unit complies with the requirements of DIN EN ISO 9170-1. Advantages Two-part construction: gas-specific basic block and connector mounting Sophisticated design: all-metal actuator with laser labelling, front panel with wavy lines and diaphragm ring Advantages Two-part construction: gas-specific basic block and connector mounting Sophisticated design: all-metal actuator with laser labelling, front panel with wavy lines and diaphragm ring 90 mm Easy installation and servicing: cartridge with sealing elements, replacement possible without blocking the station Unique marking: gas-type labelling laser labelling: chemical symbol + German + English, colour coding: neutral or in line with DIN EN ISO 5359. Easy installation and servicing: cartridge with sealing elements, replacement possible without blocking the station Unique marking: gas-type labelling laser labelling: chemical symbol + German + English, colour coding: neutral or in line with DIN EN ISO 5359. 90 mm 8 mm copper pipe 8 mm copper pipe 30 mm 33 mm 83 mm < 60 kpa (absolute pressure) vacuum < 60 kpa (absolute pressure) vacuum concealed / hollow-wall rear part (front part has to be ordered separately), O2, concealed / hollow wall installation, type DIN / AGA / NF 903.250, AIR, concealed / hollow wall installation, type DIN / AGA / NF 903.251, VAC, concealed / hollow wall installation, type DIN / AGA / NF 903.252, N2O, concealed / hollow wall installation, type DIN / AGA / NF 903.253, CO2, concealed / hollow wall installation, type DIN / AGA / NF 903.255, special gas, concealed / hollow wall installation, type DIN / AGA / NF 903.256 ACCESSORIES REQUIRED Front / wave screen to cover the built-in variant UP/HW 903.258 Front / wave screen to cover the built-in variant UP/HW (sales unit = 6 pcs.) UP/HW (sales unit = 6 pcs.) 903.259 Depth: 72 mm 60 mm 66 mm 83 mm surface mounting rear part (front part has to be ordered separately), O2, surface mounting, type DIN 903.240, AIR, surface mounting, type DIN 903.241, VAC, surface mounting, type DIN 903.242, N2O, surface mounting, type DIN 903.243, CO2, surface mounting, type DIN 903.245, special gas, surface mounting, type DIN 903.246 All front parts for terminal unit DIN, neutral or DIN EN ISO 5359 colour coding, can be found on page 11 of this product information. All front parts for terminal unit DIN, neutral or DIN EN ISO 5359 colour coding, can be found on page 11 of this product information. CEGA_for_06 CEGA_for_07

Terminal Unit DIN INSTALLATION INTO BED HEAD UNIT Terminal Unit DIN INSTALLATION IN CEILING PENDANTS The unit is used to withdraw compressed gases and vacuum from a central medical The unit is used to withdraw compressed gases and vacuum from a central medical gas supply system in line with DIN EN ISO 7396-1; integration of plugs and medical gas supply system in line with DIN EN ISO 7396-1; integration of plugs and medical appliances with plug-in connections in line with DIN 13260-2. The terminal unit appliances with plug-in connections in line with DIN 13260-2. The terminal unit complies with the requirements of DIN EN ISO 9170-1. complies with the requirements of DIN EN ISO 9170-1. Advantages Two-part construction: gas-specific basic block and connector mounting Advantages Two-part construction: gas-specific basic block and connector mounting Sophisticated design: all-metal actuator with laser labelling, front panel with wavy lines and diaphragm ring Easy installation and servicing: cartridge with sealing elements, replacement possible without blocking the station Unique marking: gas-type labelling laser labelling: chemical symbol + German + English, colour coding: neutral or in line with DIN EN ISO 5359. Sophisticated design: all-metal actuator with laser labelling Easy installation and servicing: cartridge with sealing elements, replacement possible without blocking the station Unique marking: gas-type labelling laser labelling: chemical symbol + German + English, colour coding: neutral or in line with DIN EN ISO 5359. 66 mm 60 mm 60 mm 66 mm 8 mm copper pipe < 60 kpa (absolute pressure) vacuum 6/8 mm barbed hose connector < 60 kpa (absolute pressure) vacuum FORANO, pipe straight up (front part has to be ordered separately), O2, bed-head unit pipe straight up, type DIN / AGA / NF 903.200, AIR, bed-head unit pipe straight up, type DIN / AGA / NF 903.201, VAC, bed-head unit pipe straight up, type DIN / AGA / NF 903.202, N2O, bed-head unit pipe straight up, type DIN / AGA / NF 903.203, CO2, bed-head unit pipe straight up, type DIN / AGA / NF 903.205, special gas, bed-head unit pipe straight up, type DIN / AGA / NF 903.206, pipe straight BACK (front part has to be ordered separately), O2, bed-head unit pipe straight up, type DIN / AGA / NF 903.260, AIR, bed-head unit pipe straight up, type DIN / AGA / NF 903.261, VAC, bed-head unit pipe straight up, type DIN / AGA / NF 903.262, N2O, bed-head unit pipe straight up, type DIN / AGA / NF 903.263, CO2, bed-head unit pipe straight up, type DIN / AGA / NF 903.265, special gas, bed-head unit pipe straight up, type DIN / AGA / NF 903.266 FORANO DIN for ceiling pendants DVE (front part has to be ordered separately), O2, DVE, type DIN / AGA / NF 903.230, AIR, DVE, type DIN / AGA / NF 903.231, VAC, DVE, type DIN / AGA / NF 903.232, N2O, DVE, type DIN / AGA / NF 903.233, CO2, DVE, type DIN / AGA / NF 903.235, special gas, DVE, type DIN 903.236 All front parts for terminal unit DIN, neutral or DIN EN ISO 5359 colour coding, can be found on page 11 of this product information. All front parts for terminal unit DIN, neutral or DIN EN ISO 5359 colour coding, can be found on page 11 of this product information. CEGA_for_08 CEGA_for_09

Terminal Unit DIN INSTALLATION INTO BED HEAD UNIT Front Parts Terminal Unit DIN FOR ALL INSTALLATION TYPES The unit is used to withdraw compressed gases and vacuum from a central medical gas supply system in line with DIN EN ISO 7396-1; integration of plugs and medical appliances with plug-in connections in line with DIN 13260-2. The terminal unit complies with the requirements of DIN EN ISO 9170-1. front part scope of delivery Each gas-specific front part contains the following components: Actuator Cartridge 60 mm 66 mm VS 100 M (B) Advantages Two-part construction: gas-specific basic block and connector mounting Sophisticated design: all-metal actuator with laser labelling Easy installation and servicing: cartridge with sealing elements, replacement possible without blocking the station Unique marking: gas-type labelling laser labelling: chemical symbol + German + English, colour coding: neutral or in line with DIN EN ISO 5359. 8 mm copper pipe < 60 kpa (absolute pressure) vacuum Gas-specific connector mounting Warning label (not ready for operation) Front part DIN, neutral colour coding (front part has to be ordered separately), O2, front part, type DIN German + English 903.150, AIR, front part, type DIN German + English 903.151, VAC, front part, type DIN German + English 903.152, NO2, front part, type DIN German + English 903.153, CO2, front part, type DIN German + English 903.155, special gas, front part, type DIN German + English 903.156 VS 100 M (A) FORANO DIN bed-head unit construction Trilux VS 100M (A) right (front part has to be ordered separately), O2, Trilux VS100M (A) type DIN / AGA / NF 903.210, AIR, Trilux VS100M (A) type DIN / AGA / NF 903.211, VAC, Trilux VS100M (A) type DIN / AGA / NF 903.212, N2O, Trilux VS100M (A) type DIN / AGA / NF 903.213, CO2, Trilux VS100M (A) type DIN / AGA / NF 903.215, special gas, Trilux VS100M (A) type DIN 903.216 FORANO, DIN bed-head unit construction Trilux VS 100M (B) left (front part has to be ordered separately), O2, Trilux VS100M (B) type DIN / AGA / NF 903.220, AIR, Trilux VS100M (B) type DIN / AGA / NF 903.221, VAC, Trilux VS100M (B) type DIN / AGA / NF 903.222, N2O, Trilux VS100M (B) type DIN / AGA / NF 903.223, CO2, Trilux VS100M (B) type DIN / AGA / NF 903.225, special gas, Trilux VS100M (B) type DIN 903.226 Front part DIN, ISO32 colour coding (front part has to be ordered separately), O2, front part, type DIN German + English 903.160, AIR, front part, type DIN German + English 903.161, VAC, front part, type DIN German + English 903.162, NO2, front part, type DIN German + English 903.163, CO2, front part, type DIN German + English 903.165 All front parts for terminal unit DIN, neutral or DIN EN ISO 5359 colour coding, can be found on page 11 of this product information. CEGA_for_10 CEGA_for_11

Terminal Unit AGSS Anaesthesia gas scavenging system Terminal Unit Air-motor For driving compressed air-operated tools in enclosed spaces System for safe disposal of excess anaesthetic gases and anaesthetic vapours from the clinical environment within a central medical gas supply system in line with DIN EN ISO 7396-2. Terminal unit for supplying and disposing of air used to operate surgical tools. A combination of an outlet assembly (for supply) and an inlet assembly (for disposal), which is connected to a supply and disposal system in line with DIN EN ISO 7396-1. A 28 mm All-metal construction, symbols for monitoring operation, with external ejector for vacuum generation. Suction adjustable; single-handed operation when connecting and disconnecting, unlocking via the connector receptacle. Fully mounted in a stainless steel casing, with non-return valve in the disposal system prevents return flow of consumed air. Design complies with DIN EN ISO 9170-1. Integration of plugs and medical appliances with plug-in connections in line with DIN 13260-2. stainless steel front panel (for concealed or hollow wall installation). Design complies with DIN EN ISO 9170-2. Dimensions: Material: 145 x 120 x 65 mm (WxHxD) Brass, chrome-plated; 63 mm Dimensions: Material: 145 x 120 x 65 mm (WxHxD) Brass; casing and front panel stainless steel Throughput: housing and front plate: stainless steel Min. 350 L/min at 800 kpa Throughput: Min. 50 L/min at 500 kpa copper pipe 8x1 mm / flexible tube PA 6 mm copper pipe 8x1 mm / flexible tube PA 6 mm Outlet: copper pipe 15x1 mm / wave tube 15 mm Outlet: copper pipe 15x1 mm / wave tube 15 mm Marking: colour coding in line with DIN EN ISO 9170-1 Marking: colour coding in line with DIN EN ISO 9170-2 700-1000 kpa standard magenta FORANO AGFS AGSS, concealed/hollow wall 902.073 AGSS, ceiling pendants, with external ejector 902.074 AGSS, bed-head units 902.075 AGSS, surface mounting 902.076 FORANO Air-motor Air-Motor for concealed / hollow wall installation 902.090 Air-Motor for ceiling pendants 902.091 Air-Motor for bed-head units 902.092 Air-Motor for surface mounting 902.093 Surface version 130 x 174* x 80 mm (*plus approx. 200 mm Cu pipe) Concealed version 175 x 175 mm Concealed version 175 x 175 mm Surface version 130 x 174* x 80 mm (*plus approx. 200 mm Cu pipe) CEGA_for_12 CEGA_for_13

t h e r e i s n o s u b s t i t u t e PRODUCT CATALOG Terminal Unit DIN Wall supply unit Duct for surface mounting, fully fitted with various terminal units in line with DIN EN ISO 9170-1, Air-Motor and/ or Anaesthetic Gas Scavenging System (AGSS in line with DIN EN ISO 9170 2 with integrated ejector, Air-Motor in line with DIN EN ISO 9170-1) in the aluminium duct. TERMINAL UNIT BLOCK Block of 2 or 3 terminal units in line with DIN EN ISO 9170-1. Integration of plugs and medical appliances with plug-in connections in line with DIN 13260-2. The length of the duct can be customised to suit requirements. The terminal units are already installed with piping laid. The feed pipe can come from the left, right, above, below or behind. A rail clamp with knurled nut is used to secure the block to a standard equipment rail as per DIN EN ISO 19054 (25 x 10 mm). 8x1 mm (1 terminal unit per gas) 12x1 mm (2-3 terminal units per gas) Outlet: terminal unit for integration of plugs and medical appliances with plug-in connections in line with DIN 13260-2. Colour coding: Neutral or in line with DIN EN ISO 5359 75 mm 100 mm 100 mm 100 mm 150 mm 150 mm 75 mm Wall duct (Please indicate gas type for each outlet!) Wall duct, 2 outlets 903.400 Wall duct, 3 outlets 903.401 Wall duct, 4 outlets 903.402 Wall duct, 5 outlets 903.403 Wall duct, each additional outlet 903.404 Wall duct, add-on 1 x AGSS 903.405 Wall duct, add-on 1 x air-motor 903.406 Wall supply unit, meterage 902.040 i The terminal unit blocks can be found in the Medical Accessories catalog. More information can also be found at www.greggersen.com. MED GERÄTE VON GREGGERSEN PRODUKTKATA LOG Z UBEHÖR CEGA_for_14 CEGA_for_15

t h e r e i s n o s u b s t i t u t e t h e r e i s n o s u b s t i t u t e t h e r e i s n o s u b s t i t u t e PRODUCT CATALOG Terminal Unit DIN INTERNATIONAL STANDARDS AND ADDITIONAL VARIANTS i BRITISH STANDARD, SCANDINAVIAN STANDARD (AGA), NORME FRANÇAISE, etc. The terminal unit system is available in several For other standards or custom-made designs, please Front part of terminal unit British Standard other international standards beside the DIN variant. contact us directly about the version you require. For the British Standard, Norme Francaise and AGA/ Scandinavian Standard variants, catalogs are available on our website for download. More information can also be found at www.greggersen.com. C E G A S YSTEMS BY GREGGERSEN CEGA S YSTEMS BY G R E G G E R S E N CEGA SYSTEMS BY GREGGERSEN Front part of terminal unit Norme Francaise PRODUCT I N F ORMAT I ON F ORANO A G A / S CANDINAVIAN S TANDARD PRODUCT I N F ORMAT I ON F ORANO N F / N ORME F R ANCAISE P RODUCT I N FORMAT I O N FORANO BS / BRITISH STA N D A RD Front part of terminal unit AGA Scandinavian Standard CEGA_for_16 CEGA_for_17

Terminal Unit DIN TOOLS AND ACCESSORIES height adjustment In the variant for concealed / hollow wall installation, the basic block is seated in a ring follower. After installation of the housing, the mounting tool can subsequently be used to adjust the mounting depth of the basic block. child safety lock To secure the FORANO gas terminal units against unauthorised use or for temporary shut-down of a terminal unit, we developed a child safety lock. This is intended to prevent inadvertent or unauthorized use of the terminal unit. Mounting tool for concealed / hollow wall installation height adjustment 903.300 leak test For performing the leak test in line with DIN EN ISO 7396-1. The blind flange is screwed to the basic block and closes up the terminal unit. The test pressure can then be used to check the pipe system for leaks. spanner for child safety lock O2, AIR 903.308 child safety lock VAC, N2O, CO2 903.381 spanner for child safety lock The child safety lock can be removed from the terminal unit using the key. Blind flange, brass, for pressure test 903.301 spanner for child safety lock 903.308 dismounting tool Special tool used to remove the actuator without damaging the connector mounting. actuator dismounting tool 903.302 mounting aid Mounting aid used to place a maximum of 3 or 4 concealed FORANO units next to each other. The mounting aid can be expanded, as required, by being combined with additional mounting aids. The units can be quickly, easily and accurately aligned with each other using this tool. Spacing from centre to centre: 100 mm and 150 mm mounting aid 903.303 mounting aid add-on for AGSS + Air-Motor 903.306 nicht in Betrieb! out of order! "Out of order" STICKER FOR FORANO DIN Sticker to paste over the connector mounting when shutting off the terminal unit or sections of the mains supply. diaphragm ring The diaphragm ring made of POM is clicked into a 44 mm hole. It is delivered as standard with the wave screen. However, the diaphragm ring can also be obtained as a separate component (e.g. for installation into media supply units). diaphragm ring 802.842 Allen key Allen key SW 3 with an additional, removable plastic sleeve. This sleeve guides the key in the front part of the terminal unit, virtually ruling out any tilting of the closing cone. closing cone Allen key 903.305 spanner for sealing cone retaining screw "Out of order" sticker for DIN 903.309 spanner for sealing cone retaining screw 903.304 CEGA_for_18 CEGA_for_19

greggersen gasetechnik gmbh bodestraße 27 29 21031 hamburg germany tel: +49 (0)40 73 93 57 0 fax: +49 (0)40 73 93 57 27 info@greggersen.com www.greggersen.com