EPIC J3413. Uniclass L L2123. CI/SfB (52.5) In6. The most advanced drainage system of its kind. ACO Qmax. Technical Data

Similar documents
Uniclass L L2123 EPIC J3413. CI/SfB (52.5) If9. Surface drainage for heavy duty traffic applications ACO RoadDrain

ACO Water Management: Civils + Infrastructure

ACO Drain. For more information on ACO Drain visit ACO KerbDrain 280 Splay

ACO Water Management: Civils + Infrastructure

ACO Qmax Unit size

ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator Bypass G

ACO product catalogue ACO GRP Sludge Trap G-H

ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator-G

Drainage and building solutions for Wildlife Conservation ACO Wildlife Systems

ACO product catalogue ACO GRP Grease Separators ACO Lipumax-G

ACO product catalogue ACO GRP (Glass Reinforced Plastic) Separators Grease & Light Oil Separators Sludge Trap

ACO product catalogue ACO GRP Light Oil Separators ACO Oleopator G

ACO Water Management: Civils + Infrastructure

ACO Water Management: Urban + Landscape Civils + Infrastructure

CI/SfB (52.5) May 2003 Uniclass L L2123. ACO KerbDrain The cost effective approach to kerb drainage systems

ACO Marine product catalogue ACO Clara Waste water treatment plant Sizes 3-240

ACO Water Management: Civils + Infrastructure

SOLFLO MAX LINEAR COLLECTION Linear catch basin connected with double bell outlet with integrated gasket and clips (DBIGC)

ACO Modular. ACO Product catalogue. Modular Stainless Steel Channel Drainage System. Modular 20. Modular 125. Modular 200. Floor Drainage systems

CSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator

ACO Water Management: Civils + Infrastructure

ACO Marine product catalogue ACO GM-X and GM-X-VACplus drainage pipes and steel fittings for the marine industry

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidHook Control Gate Valve

Cell Ventilation Security Grille

ACO Water Management: Civils + Infrastructure

SECTION 9 STORM SEWER INLETS

The Pump Matic Range

DURISOL ANCHORED RETAINING WALL SYSTEM (DARWS)

INFRASTRUCTURE DESIGN STANDARDS FIGURES SECTION 2 SANITARY SEWER COLLECTION SYSTEMS

Panel Floor Grilles Model LDA, MDA, HDA, PFS and F48

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M

GFX HEPCO GUIDANCE SYSTEM FOR BECKHOFF XTS

GL0098P Beta+ Septic Tanks Installation & Operation Guidelines

Concrete Pipes 62 Traditional Manholes Sealed Manholes 66 Retaining Walls 67 Boc Culverts / Gully Pots 68 Inspection Chambers 69

LINEAR SLOT DUFFUSERS

Recessed Access Covers ACCESS COVERS & DRAINAGE SYSTEMS

LINEAR SLOT DIFFUSERS

series 90-GV Variable geometry units

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

HAWLE-AIR RELEASE VALVES

Linear Slot Diffusers Model Slot 20 and Model Slot 25

Anti-Ligature Grille. There s a much bigger picture to be found at Ruskin Air Management. Model AL/35 Model AL/24. range available.

INSTALLATION GUIDELINES

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

accqpulse Velocity Profiler Sensor Installation Guide

ERHARD is a company of. Data sheet ERHARD needle valves

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

Floor Swirls Models BZD and SZD

FlowBar High Capacity Slot Diffuser

Heavy Duty Commercial Pits

RAINWATER HARVESTING SYSTEMS

VAG NOVA 284 Standpost Hydrant. Technical details. Product features

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N

EnergyShield ES. Air Control and Shut off Dampers. Dampers Controls Fancoils. Ruskin Air Management Limited

Road + Civils AG.UK.COM

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

TRADE PRICE LIST - 1st March Below Ground & Civils Systems

kb valve 2 (50)HF 2½ (65)SF installation guide aylesbury For valve sizes (DN):

The Sika Solution x 600 x 700H / 900H. Class D. Roadway Installation Guidelines p 9-11

Ceiling swirl diffusers

OVERVIEW OPERATION. 2 Stormceptor EF Technical Manual

TRADE PRICE LIST - 1st March Below Ground & Civils Systems

h Technical Product Data CC Pressure Pipe Systems

Hydro-Brake Optimum Design Tool. Step by Step Guide

Covers and Frames Ductile Iron Covers and Frames Gully Grates D Surface Boxes 270 Steel Covers and Frames

Description. Functions. Technical data. Applications. Tests. Level control float valve, enabling the control of the filling level.

A good commercial reason.

TBM Series 3-Way Ball Valve

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

Lane Reverse Q Pond Outlet Installation and Maintenance Guide

SIHI multi Type MSC. Modular multistage pumps. Description. Construction. Applications. Optional special designs. Materials.

Eclipse RatioAir Burners

AquaGrip. Unique. Couplings & Flange Adaptors. For Polyethylene Pipe Connections

INSERTION flowmeter with paddle wheel, ELEMENT design

wipes ready technology

Reliable backwater protection. Protection from backwater. Backwater protection for interior installation

Adjustable Curved Vane Diffusers. Vanes are parallel to the width dimension Vanes are parallel to the height dimension

MARINE BREAKAWAY COUPLING

HIGH CAPACITY LINEAR SLOT DUFFUSERS

Ceiling swirl diffusers with perforated face plate

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidGate Control Valve

PIPE & CONDUIT SYSTEMS. Free Call:

SPECIFICATION OF TRAILOR MOUNTED SEWER JETTING MACHINE RAMJET 1500 Lts.

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

SINGLE DUCT TERMINAL UNITS

Krantz. Floor displacement outlet Q-B-DN 200. Air distribution systems

Fuel and Oil Separators

GMR-S and GMR40-S Disc Brake Caliper - Spring Applied, Air Released

HOW TO INSTALL YOUR BOV

Lockinex. Armco Crash Barrier. great service, great quality. W Section, W section Plus1 & Box Beam type. Material grade BS EN S275

YARWAY NARVIK MODEL 88 SPID SMALL PIPE INLINE DESUPERHEATER

2/2-Way and T Valve Bodies in Stainless Steel

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Industrial Valves Flow Control Valve ZW SDR - Modular

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Novenco axial flow fans. ZerAx - Standard January 2010

Gullies. Box - Gutters. Slot - Gutters. Grease Locks

Cross Flow Heat Exchanger H352

E R A I GATE AUTOMATION DIVISION

ISO. Carts & Accessories. Distributed by:

Transcription:

Uniclass L7315 + L2123 EPIC J3413 CI/SfB (52.5) In6 The most advanced drainage system of its kind ACO Qmax Technical Data

ACO Qmax System Contents Load Classes 3 ACO Qmax 600 System Pedestrian and Car Park applications 4 Highway, Distribution Centre and Airport Pavement applications 5 Accessories 6 ACO Qmax 900 System Pedestrian and Car Park applications 7 Highway, Distribution Centre and Airport Pavement applications 8 Accessories 9 ACO Qmax Flow Regulators 10 Geometry and Properties Data 11 ACO Qmax System 2

ACO Qmax System Load Classes ACO Qmax is suitable for use in all load class applications. The patented beam feature enables use of the optimum pavement reinforcement details when dealing with specialist and high load situations, thereby reducing total cost and ensuring speed of installation is not compromised. Additional reinforcement may be specified in the concrete surround for higher load applications. ACO Qmax is suitable for the following applications: Group1 Group 2 Group 3 Group4 Group 5 Group 6 BS EN 1433:2002 Load Class Load Class A 15kN Load Class B 125kN Load Class C 250kN Load Class D 400kN Load Class E 600kN Load Class F 900kN Pedestrian Private car parks Public car/van parks Highways Distribution centres Airport pavements The ACO Qmax channel system is protected by patent and registered design rights. All intellectual rights are the property of ACO Technologies plc. 3

2 3 2 ACO Qmax 600 System Pedestrian and Car Park applications - 600 system: Ovoid Channels A B C D Dimensions length Slot width Overall height waterway intake area (mm 2 ) 401002 400 x 600 2000 10 940 20,000 38 642mm 2000mm 400mm 880mm 940mm Each channel section, manufactured from tough and corrosion resistant MDPE is supplied complete with: Discrete galvanised steel heel safe (10mm slot width) continuous waterway inlet slot waterway inlet area: 10000mm 2 /m Channel assembly and connection fixings Ovoid Channel complete with Side Inlets Dimensions length Slot width Overall height waterway intake area (mm 2 ) Finished road level to of nominal bore pipe connection Ø150mm Ø225mm Ø300mm 401013 400 x 600 1000 10 940 10,000 23 635 673 710 642mm 1000mm Ø200mm 400mm Ø380mm 880mm 940mm 4 Notes 1. 1-metre channels supplied with symmetrical horizontal inlet spigots for easy pipe connections in vitrified clay, concrete or plastic. 2. 150mm, 225mm and 300mm nominal bore inlet pipes accommodated. 3. Side inlet spigots are supplied blank and easily opened with a handsaw or disc cutter. Connection to pipes achieved by selecting appropriate flexible couplings supplied by others. 4. For reference, actual pipe connection spigot outside diameters: 200mm and 380mm.

ACO Qmax 600 System Highway, Distribution Centre and Airport Pavement applications - 600 system: D E F Ovoid Channels Dimensions length Slot width Overall height waterway intake area (mm 2 ) 401000 400 x 600 2000 30 940 60,000 38 2000mm 1180mm 1240mm Each channel section, manufactured from tough and corrosion resistant MDPE is supplied complete with: Heavy duty hot dipped galvanised steel edge continuous waterway inlet slot protection frame 40mm x 40mm x 4mm waterway inlet area: 30,000mm 2 /m Heavy-duty concrete anchors 150mm long, 500mm centres Channel assembly and connection fixings Ovoid Channel complete with Side Inlets Dimensions length Slot width Overall height waterway intake area (mm 2 ) Finished road level to of nominal bore pipe connection Ø150mm Ø225mm Ø300mm 401011 400 x 600 1000 30 940 30,000 23 635 673 710 1000mm Ø200mm Ø380mm 1180mm 1240mm Notes 1. 1-metre channels supplied with symmetrical horizontal inlet spigots for easy pipe connections in vitrified clay, concrete or plastic. 2. 150mm, 225mm and 300mm nominal bore inlet pipes accommodated. 3. Side inlet spigots are supplied blank and easily opened with a handsaw or disc cutter. Connection to pipes achieved by selecting appropriate flexible couplings supplied by others. 4. For reference, actual pipe connection spigot outside diameters: 200mm and 380mm. 5

ACO Qmax 600 System Accessories - 600 system: Universal channel stop end Description Universal channel stop end 40104 6 642mm 60mm Can also be used for upstream or downstream temporary works. Complete with channel connection fixings. Ø200 and Ø250 knockouts provided for pipe outlet connection. Universal access chamber connector pair (375mm nominal bore) Description Universal access chamber connector pair (375mm nominal bore) 40105 the pair 20 the pair 400mm 780mm 642mm 400mm 811mm 642mm Ø375mm 722mm Ø375mm 722mm 722mm Ø250mm Ø200mm EPDM Water Seal Each set providing inlet AND outlet connections to access chamber. Compatible with 375mm nominal bore TwinWall pipe and suitable for upstream and downstream channel connection. Complete with channel fixings. Description EPDM Water Seal 40251 506mm 706mm 6 One off EPDM Seal if required to be ordered per channel, stop end or universal access chamber connector pair.

3 2 3 2 ACO Qmax 900 System Pedestrian and Car Park applications - 900 system: Ovoid Channels A B C D Dimensions length Slot width Overall height waterway intake area (mm 2 ) 401502 600 x 900 2000 10 1240 20,000 64 2000mm 1180mm 1240mm Each channel section, manufactured from tough and corrosion resistant MDPE is supplied complete with: Discrete galvanised steel heel safe (10mm slot width pattern) continuous waterway inlet slot waterway inlet area: 10,000mm 2 /m Channel assembly and connection fixings Ovoid Channel complete with Side Inlets Dimensions length Slot width Overall height waterway intake area (mm 2 ) Finished road level to of nominal bore pipe connection Ø150mm Ø225mm Ø300mm 401513 600 x 900 1000 10 1240 10,000 41 940 1015 1050 1000mm Ø200mm Ø380mm 1180mm 1240mm Notes 1. 1-metre channels supplied with symmetrical horizontal inlet spigots for easy pipe connections in vitrified clay, concrete or plastic. 2. 150mm, 225mm and 300mm nominal bore inlet pipes accommodated. 3. Side inlet spigots are supplied blank and easily opened with a handsaw or disc cutter. Connection to pipes achieved by selecting appropriate flexible couplings supplied by others. 4. For reference, actual pipe connection spigot outside diameters: 200mm and 380mm. 7

ACO Qmax 900 System Highway, Distribution Centre and Airport Pavement applications - 900 system: D E F Ovoid Channels Dimensions length Slot width Overall height waterway intake area (mm 2 ) 401500 600 x 900 2000 30 1240 60,000 64 2000mm 1180mm 1240mm Each channel section, manufactured from tough and corrosion resistant MDPE is supplied complete with: Heavy duty hot dipped galvanised steel edge continuous waterway inlet slot protection frame 40mm x 40mm x 4mm waterway inlet area: 30,000mm 2 /m Heavy-duty concrete anchors 150mm long, 500mm centres Channel assembly and connection fixings Ovoid Channel complete with Side Inlets Dimensions length Slot width Overall height waterway intake area (mm 2 ) Finished road level to of nominal bore pipe connection Ø150mm Ø225mm Ø300mm 401511 600 x 900 1000 30 1240 30,000 41 940 1015 1050 1000mm Ø200mm Ø380mm 1180mm 1240mm 8 Notes 1. 1-metre channels supplied with symmetrical horizontal inlet spigots for easy pipe connections in vitrified clay, concrete or plastic. 2. 150mm, 225mm and 300mm nominal bore inlet pipes accommodated. 3. Side inlet spigots are supplied blank and easily opened with a handsaw or disc cutter. Connection to pipes achieved by selecting appropriate flexible couplings supplied by others. 4. For reference, actual pipe connection spigot outside diameters: 200mm and 380mm.

ACO Qmax 900 System Accessories - 900 system: Universal channel stop end Description Universal channel stop end 40154 11 60mm Can also be used for upstream or downstream temporary works. Complete with channel connection fixings. Ø200, Ø250 and Ø300 knockouts provided for pipe outlet connection. Universal access chamber connector pair ( nominal bore) Description Universal access chamber connector pair ( nominal bore) 40155 the pair 37 the pair 780mm 811mm 591mm 1022mm 591mm 1022mm 1022mm Ø300mm Ø250mm Ø200mm EPDM Water Seal Each set providing inlet AND outlet connections to access chamber. Compatible with nominal bore TwinWall pipe and suitable for upstream and downstream channel connection. Complete with channel fixings. Description EPDM Water Seal 40250 706mm 1006mm One off EPDM Seal if required to be ordered per channel, stop end or universal access chamber connector pair. 9

ACO Qmax System ACO Q-Brake Flow Regulator The ACO Q-Brake is a flow regulator which can be installed in the ACO Qmax channel to regulate the discharge flow rate to a sewer or watercourse, and to utilise the storage capacity of the ACO Qmax channel. Advantages Very compact. Occupies no additional volume as it resides inside the channel. No extra manholes required. Cost effective compared to most other solutions. Easy and quick to install. Laboratory verified performance. Standard regulator sizes available, custom sizes easily accommodated. 304 stainless steel construction for longevity. No moving parts. No loose parts to get lost. Silt formation and floating debris encouraged to pass through regulator. By-pass facility for heavy storm applications (optional). Can be used in cascade form to increase ACO Qmax storage volume on sloping sites. The flow regulator is cut from 3mm thick 304 stainless steel plate and is conveniently sandwiched in the recess between any two connecting channels or channel and manhole connector. The stainless steel construction ensures the design life will exceed a 30-year life. Flow Rate (l/s) 15 ACO Qmax 600 20 ACO Qmax 600 25 ACO Qmax 600 30 ACO Qmax 600 15 ACO Qmax 900 20 ACO Qmax 900 25 ACO Qmax 900 30 ACO Qmax 900 40278 40279 40280 40281 40262 40263 40264 40265 5.0 5.0 5.0 5.0 14.0 14.0 14.0 14.0 ACO has conducted full-scale laboratory trials to validate the design parameters of the combined orifice and vee notch weir. Many combinations of weir and orifice geometries can be used to best optimise the performance of the installed ACO Q-Brake flow regulator for a given site. 10 Note: For customised flow regulation outside the standard range, contact the ACO Drain Design Service Department. The ACO Q-Brake is an additional component of the ACO Qmax System.

ACO Qmax System 1.0 ACO Qmax : Geometry and Properties Data 1.1 ACO Qmax : Geometry and Properties Data of the MDPE liner Shape ACO Qmax 600 Ovoid ACO Qmax 900 Ovoid Cross Sectional Area (m 2 ) 0.1838 0.4135 Perimeter (m) 1.585 2.380 Hydraulic Radius (m) 0.116 0.174 Critical Velocity (m/s) 2.14 2.60 Material Thickness 4.0 nominal 6.0 nominal 2m channel unit assembly 38 64 1m channel unit assembly 23 41 Internal Dimensions Depth (m) 0.600 0.900 Maximum width (m) 0.400 0.600 External Dimensions Width o/a collar (m) 0.645 0.845 o/a height (m) 0.940 1.240 Inlet Slot Internal width 30.0 (10.0 ) 30.0 (10.0 ) Corrosion protection life (years) 30* 30* * In an unpolluted environment the atmospheric zinc depletion rate per 100 metres of channel run (assuming 2 microns per year) is 0.23kg / year. With a mean galvanising thickness of 70 microns, a life in excess of 30 years may be expected. Airport pavement, distribution centre and highway applications unless otherwise stated Car park applications 1.2 Geometry and Properties of Concreted Section Minimum Width (m)* Minimum Depth (m)** Depth (m) incl. angle Concrete per metre Length** Reinforcement ACO Qmax 600 0.8 1.1 approx. 0.880 <0.7m 3 see section 2.0 ACO Qmax 900 1.0 1.4 approx. 1.180 <1.0m 3 see section 2.0 * ** Excluding working space and formwork Excluding blinding concrete 1.3 Typical Channel Arrangements Length to Outlet (m) Catchment Depth (m) Longitudinal Slope (%) Area Drained (ha) ACO Qmax 600 50 1000 5 100 0.0 1.0* 0.25 3.0 ACO Qmax 900 50 1500 5 200 0.0 1.0* 0.25 5.0 * Note that by accepting a greater outlet spacing at steeper slopes then the flow velocity will tend to exceed the critical velocity Airport pavement, distribution centre and highway applications 11

ACO Qmax System LITERATURE FOR ACO QMAX ACO QMAX SYSTEM HYDRAULICS & LEGISLATION SITEWORK & INSTALLATION Call for literature or more information: 01462 816666 ACO Technologies plc ACO Business Park, Hitchin Road, Shefford, Bedfordshire SG17 5TE Tel: 01462 816666 Fax: 01462 815895 e-mail Sales: customersupport@aco.co.uk e-mail Technical: draintechnical@aco.co.uk website: www.aco.co.uk ACO Qmax is a registered trademark of ACO Technologies plc. The ACO Qmax channel system is protected by patent and registered design rights. All intellectual rights are the property of ACO Technologies plc. Any infringement of these property rights will result in the appropriate legal action being taken. November 2009 ACO Technologies plc. All reasonable care has been taken in compiling the information in this document. All recommendations and suggestions on the use of ACO products are made without guarantee since the conditions of use are beyond the control of the Company. It is the customer's responsibility to ensure that each product is fit for its intended purpose, and that the actual conditions of use are suitable. This brochure and any advice is provided by ACO Technologies plc (the Company) free of charge and accordingly on terms that no liability including liability for negligence will attach to the Company or its servants or agents arising out of or in connection with or in relation to this brochure or any such advice. Any goods supplied by the Company will be supplied solely upon its standard conditions of sale, copies of which are available on request. The Company's policy of continuous product development and improvement renders specifications liable to modification. Information provided in this brochure is therefore subject to change without prior notification. PC20667