Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies

Similar documents
% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

3 Way/2 Position Valves

Constructions Suitable for -40 C to -50 C Ambient

Control & Power, Inc

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4" to 1" NPT. Features

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

2-Way/2 Position Valves

Proveedor Integral de Soluciones para la Industria. Desde1963

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F

Proveedor Integral de Soluciones para la Industria

4 N E X T G E N E R A T I O N

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical.

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT ^ % )

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F

2/2 ^ % ) Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

2/2 3/2 4/2 SERIES Air Operated. General Service Air Operated Valves. Brass Body 1/4" to 2" NPT. Features. Construction.

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Design, Plans, and Specifications for an Air-Assisted Filter Backwash System at the Thomas Hill Energy Center Water Treatment Plant

2/2 ) % ) % ) Assemblies. Solenoid and Piloted Piston Valve Series Condensate Drain Valve Assemblies. Brass or Stainless Steel Bodies 1/4" to 1" NPT

4 qwer. Air Operated Valves 2/2 3/2 4/2 SERIES. Air Operated. General Service. Brass or Stainless Steel Bodies 1/4" to 2" NPT. Features.

SOLENOID VALVES pilot operated for hot water/steam applications 3/8 to 1

深圳市永旭伟业贸易有限公司 SOLENOID VALVES pilot operated, spool type single/dual solenoid (mono/bistable function) stainless steel body, 1/4.

SOLENOID VALVES no voltage release (tamperproof) manual reset construction 1/4

SERIES ASCO Valves DESCRIPTION OPERATION INSTALLATION. Positioning. Page1of5(Section1of2) I&M No.V9575R3 (Section1of2)

Asia Pacific Express Catalog

MICRO SOLENOID VALVE pinch mechanism for flexible tube O.D to 9.5 mm

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

DIRECT OPERATED SOLENOID PILOT VALVES Product Index

Over 2000 of today's most popular products

Valve Reference C5. Valve Reference C6. 4-Way. 4-way direct acting

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function)

POWER PULSE VALVES integral pilot (external exhaust) threaded or Quick Mount connection 3/4 to 1 1/2

GUARANTEED SAME DAY SHIPMENT General Service - 2/2 NC 1/" Kit Coil Weight (ins.) (ins.) Flow Min. Air Water Oil Temp. F Number Material Material Volta

Data sheet. 2-way solenoid valves with Clip-on coils for neutral liquids and gases. January 2003 DKACV.PD.200.K B1472

High Pressure Solenoid Valves

Solenoid Valves. Options/Accessories - ASCO offers a wide variety of accessories and optional features to meet your specific application requirements.

ACCESSORIES FOR AIR VALVES & AIR SYSTEMS

MINI-SOLENOID VALVES ISO (CNOMO, size 15) interface direct operated, pad mounting body connector size 15

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

Miniature Multimedia Valves

4 Series 298 Air Operated Stainless Steel Piston Valves For Steam and Aggressive Fluid Service

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

SKINNER Intrinsically Safe Series Four-Way

MINIATURE SOLENOID GENERAL SERVICE VALVES

Transmitters: Relay Valve VR4151/4152

An example of an ASCO valve catalog number with prefixes and suffixes: EF HT 8210 G 002 V MO. Construction Features. Number

LIMIT SWITCH Axiom - AX

Condensate Drain Valve Assemblies

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

WELCOME TO MAGNATROL

Direct-acting 2/2-way plunger valve

Motorised Valve Range

Glove Box Instrumentation Specifications

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

188 Dimensions: Inches [mm] In-line Version Solenoid valves assembled to manifolds ( Normally closed, orifice only. onsult ASO for alternative c

4 Dynamic Solutions. Leadership and Innovation in Valve Products and Valve Systems

Redundant Control System

Electronic Control Valves

Super X Inline 3/2 and 5/2 Spool valves, solenoid and pilot actuated

SOLENOID CONTROL VALVE

SOLENOID VALVES no voltage release (lever type) manual reset construction 1/4 to 1/2

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

Customized Solutions. Safety & Reliability Stainless steel 316 products

PROCESS & AUTOMATED VALVES

Hazardous Location Solutions for the Process Control Industry. UL CSA FM ATEX IECEx NEPSI INMETRO TR CU

Transmitters: Relay Valve

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

Air Actuated Ball Valves 2-Way, Lead Free Brass, Full Port 1/4 to 3 NPT

AIR RIDE SUSPENSION SYSTEMS

SPOOL VALVES pilot operated or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

2/2-way Solenoid Valve for liquids and gases

Direct-acting 2/2- or 3/2-way pivoted armature valve

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

AUTOMATIC FLOW CONTROL VALVE. INSTRUCTIONS Installation - Operation - Inspection - Maintenance

Solenoid Valves Catalogue

LIMIT SWITCH Axiom - AX

2/2-way Angle-Seat Valve for high-quality cryogenic applications and steam

3-Way. Direct Acting & Pilot Operated Quick Exhaust Valves 1/4" - 3/8" NPT. General Description: Applications: Electrical Characteristics:

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Control Valve Specifications

SPOOL VALVES pilot or air operated, spool type single/dual solenoid (mono/bistable function) brass body, 1/4

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Series VP4 50/4 70. Large Size 5 Port Solenoid Valve Rubber Seal SJ SY SY SV SYJ SZ VF VP4 S0700 VQ VQ4 VQ5 VQC VQC4 VQZ SQ VFS VFR VQ7 VP4

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

DE- OUT OUT DE- OUT OUT DE- SERIES MODEL E21 2-WAY NORMALLY OPEN CONDUIT HOUSG (700) 235 (0) 1 (3) (1) (700) 235 (0) 1 (3) (1) E21G7XC

Direct solenoid and solenoid pilot operated valves

Operating pressure (bar) kv factor (m 3 /h) *3)

Control Valve Specifications

Performance Data. Temperature Range. -20 o to 160 o F 26 Hg to 125 psi. C v Flow Rate (scfm) Fill Time Exhaust. Port.

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Transcription:

Constructions Suitable for - C to -5 C Ambient, 3 and Way Constructions Available Brass, Aluminum and Stainless Steel Bodies Air and Inert Gas Service

INDEX General Service Valves -Way/ Position 8 Aluminum Body 83 High Pressure 86/863 General Service Normally Open 6 86/863 General Service Normally Closed 8 3-Way/ Position 83 General Service 836 General Service 837 Quick Exhaust 83 General Service 6 83 Direct Mount 8 837 High Flow Direct Acting 855 RedHat II Spool Valve -Way/ and 3 Position 83 Piston/Poppet 855 RedHat II Spool Valve 6 855 Direct Mount 8 Special Service Valves Cryogenic and Liquid CO 3 Manual Reset 3 Low Power -. W 3 Low Power -.55 W 38 Intrinsically Safe and Non-Incendive Field Wiring Intrinsically Safe Manual Reset 5 Tamper Proof Manual Reset 5 ATEX 55 Air/Inert Gas Quality Statement for Low Ambient Valves DEWPOINT To prevent freezing of condensed water vapour in the valve, the air/inert gas must have a dewpoint at least F (8 C) below the minimum temperature to which any point of the system will be exposed. LUBRICATION The use of lubricators upstream of valves is NOT recommended. Likewise, air containing compressor carry over lubricants requires cleaning with suitable filters upstream of the valve. Hydrocarbon oil, with its characteristic viscosity increase at low temperatures, may cause the valve to operate erratically or to fail to operate. Note: For Engineering/Principle of Operation information refer to Cat. 35. Accessories Quick Exhaust/Shuttle Valve 57 Optional Features Explosionproof Junction Box 58

Direct Acting Aluminum Body Solenoid Valves /8" to 3/" NPT / 8 -WAY Features Lightweight, low-cost valves for air service F M APPROVED Ideal for low pressure applications Provides high flow, Cv up to 9.5 Air service Construction Valve Parts in Contact with Fluids Body Aluminum Seals, Diaphragms, Disc NBR Core Guide POM Rider Rings PTFE Core and Plugnut 3F Stainless Steel Springs* 3 Stainless Steel Shading Coil Copper * For 8H6, 8H7, 8H8, spring material is 7-7 PH NC Electrical Solenoid Enclosures Watt Rating and Power Standard Consumption Spare Coil Part Number Coil and AC General Purpose Explosionproof Class of VA VA Insulation Watts Holding Inrush AC AC F 6. 6 38 38 F. 5 7 386 386 Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). Must be specified when ordering. Other voltages available when required. Standard: RedHat II - Watertight, Types,, 3, 3S,, and X. Optional: RedHat II - Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number.) For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) Approvals CSA certified, UL listed and FM approved. Meets applicable CE directives.

-WAY / 8 Specifications Pipe Orifice Cv Flow Factor Min. NORMALLY CLOSED (Closed when de-energized) Operating Pressure Differential (psi) AC Fluid Temp. F Aluminum Body Watt Rating/ Class of Coil Insulation ➀ Air-Inert Gas AC Catalogue Number Ref. AC DC /8 5/6. 5 5 8H6 6./F - / 5/6. 5 5 8H7 6./F - 3/8 5/6. 5 5 8H8 6./F - / 3/ 5. 5 8G 3A./F - 3/ 3/ 9.5 5 8G3 3B./F - ➀ On 5 hertz service, the watt rating for the 6./F solenoid is 8. watts. Dimensions: inches (mm) Ref. H K L P W ins..7...3.69 mm 69 36 5 58 3 3A ins..5.6.75 3.. mm 3 63 7 87 6 3B ins..9.65 3.3 3.63.39 mm 67 8 9 6 NPT BOTH ENDS Ref. 3A, 3B P K H / NPT IMPORTANT: Valves may be mounted in any position. L FLOW W.66 [] MOUNTING HOLES Ø.8 [Ø 7.] Ref. W / NPT CORED HOLES.35 [8.9] DEEP FOR.6-3 TH D FORMING SCREW.8 [.3].6 [5] NPT BOTH ENDS P H K.6 [.3] R.88 [R.] PLACES.9 [3].5 [6.] IN BOTTOM VIEW OF BODY L.5 [.9] PLACES.75 [9.].97 [5] FLOW 3

Pilot Operated High Pressure Solenoid Valves Stainless Steel Bodies /" NPT / 83 -WAY Features Rugged piston construction built to withstand pressure ratings to 5 psi Angle body design for high flows Ideal for high-pressure applications Mountable in any position Construction Body Seals and Disc Core Tube Core and Plugnut Core Spring Shading Coil Valve Parts in Contact with Fluids 3 Stainless Steel PTFE, NBR 35 Stainless Steel 3F Stainless Steel 3 Stainless Steel Silver NC Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number AC Explosionproof DC Watts Watts VA Holding VA Inrush AC DC F.6 7. 7 386 387 Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages available when required. Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Approvals CSA certified, UL listed solenoid. Meets applicable CE directives.

-WAY / 83 Specifications Operating Pressure Differential (psi) AC DC Fluid Temp. F Stainless Steel Body Watt Rating/ Class of Coil Insulation Pipe Orifice Cv Flow Factor NORMALLY CLOSED (Closed when de-energized) Min. Air-Inert Gas Air-Inert Gas AC DC Catalogue Number Ref. AC DC / 3/8 3. 5 5 5 5 EFX83GMF/6663 7./F.6/F Dimensions: inches (mm) Ref. H K L P W ins..3.5.5 3.3.95 mm 55 6 8 5 5 ins. 5.3.53 3.53 3.5 3.5 mm 8 6 9 89 89 / NPT Ref. & 5 K P H OUTLET NPT PLACES INLET L W INLET LOCATED ON BOTTOM FOR 5

Direct Acting General Service Solenoid Valves Brass or Stainless Steel Bodies Normally Open /8" to 3/8" NPT / 86 863 -WAY Features Reliable, proven design with high flows Small poppet valves for tight shutoff Wide range of elastomers for specialty service Mountable in any position Brass and stainless steel constructions Construction Valve Parts in Contact with Fluids Body Brass 33/3 Stainless Steel Seals and Discs NBR or Cast UR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Springs 3 Stainless Steel Shading Coil Copper Silver Stem PA NO Electrical Watt Rating and Power Consumption Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC.6. 5 5 386 389 386 389.6 7. 7 388 389 388 389 Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages available when required. Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number) See Optional Features Section for other available options. Options Mounting bracket (suffix MB) High Vacuum service (suffix VH; see Vacuum Section for more details.) Oxygen service (suffix N) Silicone Free (suffix SF) Elastomers: Low Temp. NBR (suffix A) Nominal Fluid Temp. Range AC & DC: - F to 67 F (- C to 75 C) Nominal Ambient Temp. Ranges AC Class F Coil Option: - F to 3 F (- C to 55 C) AC Class H Coil Option: - F to F (- C to 6 C) DC Class H Coil Option: - F to 3 F (- C to 55 C) Refer to Engineering Section for fluid and temperature compatibility. Note: ambient for explosionproof (EF) is 5 F (5 C) for AC, 3 F (55 C) for DC. Refer to Engineering Section for details. Approvals CSA certified. UL listed, as indicated. Meets applicable CE directives. Refer to Engineering Section for details. 6

-WAY / 86 863 Specifications (English units) Operating Pressure Differential (psi) Fluid Watt Rating/Class Pipe Orifice Cv Max AC@3 F Max DC@3 F Temp F Catalogue Number of Coil Insulation Flow Air-Inert Lt. Oil @ Air-Inert Lt. Oil @ UL (in) (mm) Factor Gas Water 3 SSU Gas Water 3 SSU AC DC Brass Stainless Steel Ref Listing AC DC NORMALLY OPEN (Open when de-energized) /8 3/6.6 5 375 5 7 6 5 86H5A➀ - l 7./H.6/H /8 3/6.6 65 375 5 7 6 5-86H67A➀ l 7./H.6/H /8 3/6.6 5 9 8 6 9 35 86H55A➀ 86H68A➀ l./f.6/h /8 3/6.6 75 75 75 65 56 8 8 86H56A 86H69A l./f.6/h /8 3/3. 35 35 75 3 9 55 67 8 86H57A 86H7A l 7./H.6/H /8 3/3. 75 3 8 6 35 95 8 8 86H8A 86H36A l./f.6/h /8 /8.35 95 75 35 67 8 86H58A 86H73A l 7./H.6/H /8 /8.35 6 5 5 7 8 8 86H9A 86H37A l./f.6/h / 3/6.6 5 375 5 9 6 5 86H59A➀ - l 7./H.6/H / 3/6.6 65 375 5 9 6 5-86H98A➀ l 7./H.6/H / 3/6.6 5 9 8 6 9 35 86H6A➀ 86H99A➀ l./f.6/h / 3/6.6 75 75 75 65 56 8 8 86H6A 86H3A l./f.6/h / 3/3. 35 35 75 3 9 55 67 8 86H6A 86H5A l 7./H.6/H / 3/3. 75 3 8 6 35 95 8 8 86H6A 86H3A l./f.6/h / /8.35 95 75 35 67 8 86H63A 86H9A l 7./H.6/H / /8.35 6 5 5 7 8 8 86H6A 86H38A l./f.6/h / 5/3.5 5 75 65 55 67 8 86H6A 86H3A l 7./H.6/H / 5/3.5 9 9 7 6 55 5 8 8 86H63A 86HA l./f.6/h / 7/3.83 6 55 55 35 35 3 67 8 86H65A 86HA l 7./H.6/H / 7/3.83 5 5 3 5 5 8 8 86H6A 86H8A l./f.6/h / 9/3.96 38 38 38 5 5 5 67 8 86H66A 86H5A l 7./H.6/H / 9/3.96 3 3 3 7 7 8 8 86H65A 86H5A l./f.6/h 3/8 /8.35 95 75 35 67 8 863HA 863HA 3 l 7./H.6/H 3/8 /8.35 6 5 5 7 8 8 863H7A 863H8A 3 l./f.6/h 3/8 5/3.5 5 75 65 55 67 8 863HA 863H5A 3 l 7./H.6/H 3/8 5/3.5 9 9 7 6 55 5 8 8 863H7A 863H8A 3 l./f.6/h 3/8 7/3.83 6 55 55 35 35 3 67 8 863HA 863H6A 3 l 7./H.6/H 3/8 7/3.83 5 5 3 5 5 8 8 863H7A 863H8A 3 l./f.6/h 3/8 9/3.96 38 38 38 5 5 5 67 8 863H3A 863H7A 3 l 7./H.6/H 3/8 9/3.96 3 3 3 7 7 8 8 863H73A 863H83A 3 l./f.6/h ➀ Cast UR disc supplied as standard. l General Purpose Valve. Dimensions: inches (mm) Ref. H K L P W ins. 3..5.9.69.6 mm 76 39 3 68 5 ins. 3..6.56.76.6 mm 79 7 5 3 ins. 3..6.88.77.6 mm 8 8 7 5 IMPORTANT: Valves may be mounted in any position. Ref. -3 W.3 [8] Ref. (/8" Pipe).59 [5] MOUNTING HOLES Mounting Dimensions Ref. 3 (3/8" Pipe).69 [8] MOUNTING HOLES FLOW M5 THREAD.5 [6.] MIN. FULL THREAD DEPTH. HOLES FOR MOUNTING.57 [].75 [9] MOUNTING HOLES K P H.3 [9] Ref. (/" Pipe).87 [.] MOUNTING HOLES.8 [.6] MOUNTING HOLES FLOW M5 THREAD. [6] MIN. FULL THREAD DEPTH HOLES FOR MOUNTING L ANPT PIPE THREAD ( PLACES).87 [.] MOUNTING HOLES FLOW M5 THREAD.3 [7.6] MIN. FULL THREAD DEPTH HOLES FOR MOUNTING Note: Mounting holes will accept a standard #-3 machine screw. 7

Direct Acting General Service Solenoid Valves Brass or Stainless Steel Bodies Normally Closed /8" to 3/8" NPT / 86 863 -WAY Features Welded core tube provides higher pressure ratings F M APPROVED Reliable, proven design with high flows Small poppet valves for tight shutoff Wide range of elastomers for specialty service applications Mountable in any position Tapped mounting holes in body standard Construction Valve Parts in Contact with Fluids Body Brass Cast 3 Stainless Steel Seals and Discs NBR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Springs 3 Stainless Steel Shading Coil Copper Silver Electrical DC Watts Watt Rating and Power Consumption Spare Coil Part No. AC General Purpose Explosionproof VA Watts Holding VA Inrush AC DC AC DC.6. 5 5 386 389 386 389.6 7. 7 386 389 386 389 Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages available when required. NC Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number) See Optional Features Section for other available options. 863 Nominal Ambient Temp. Ranges The nominal limitation of 3 F ( C) is advisable for any valve that might contain moisture (water vapour). AC: - F to 3 F (- C to 55 C) DC: - F to F (- C to C) - F to 3 F (- C to 55 C) Note: Max ambient for explosionproof (EF) is 5 F (5 C) for AC, 3 F (55 C) for DC. Optional: For AC, the max. ambient temperature is F (6 C) with Class H coil (with or without prefix EF) Refer to Engineering Section for details. Approvals CSA certified. UL listed, as indicated. Meets applicable CE directives. 8

-WAY / 86 863 Specifications Pipe Orifice size Cv Flow Factor Operating Pressure Differential (psi) Catalogue Number Watt Rating/ Fluid Class of Coil AC@3 F DC@ F DC@3 F Temp. F Insulation Air-Inert Gas Water Lt. Oil @ 3ssu Air-Inert Gas Water Lt. Oil @ 3ssu Air-Inert Gas Water Lt. Oil 3ssu AC DC Brass Stainless Steel Ref. AC DC NORMALLY CLOSED (Closed when de-energized), NBR Disc /8 3/3. 7 6 6 67 67 86H77A 86H78A 7./F.6/H /8 3/3. - - - 9 9 7 55-67 - 86H77A -.6/H /8 /8.35 5 38 355 75 75 35 5 5 5 67 67 86H5A 86H7A 7./F.6/H /8 /8.35 3 3 5 - - - - - - 67 - - 86H79A./F - / 3/3. 7 6 6 67 67 86H9A 86H83A 3 7./F.6/H / 3/3. 59 9 9 7 5 67 67 86H8A 86H8A 3./F.6/H / /8.35 5 38 355 75 75 35 5 5 5 67 67 86HA 86H85A 3 7./F.6/H / /8.35 3 3 5 3 5 5 5 67 67 86H3A - 3./F.6/H / /8.35 3 3 5 - - - - - - 67 - - 86H8A 3./F - / 5/3.5 3 35 35 35 5 5 5 67 67 86HA 86H87A 3 7./F.6/H / 5/3.5 5 65 63 63 55 5 5 67 67 86HA - 3./F.6/H / 5/3.5 5 - - - - - - 67 - - 86HA 3./F - / 7/3.73 5 5 5 7 7 7 65 65 65 67 67 86HA 86H88A 3 7./F.6/H / 7/3.73 35 35 35 3 3 3 67 67 86H8A - 3./F.6/H / 7/3.73 - - - - - - 67 - - 86H6A 3./F - / 9/3.88 9 9 9 53 5 7 8 6 67 67 86HA 86H3A 3 7./F.6/H / 9/3.88 65 75 6 5 5 67 67 86HA - 3./F.6/H / 9/3.88 65 75 6 - - - - - - 67 - - 86H89A 3./F - 3/8 /8.35 5 38 355 75 75 6 5 5 5 67 67 863H5A 863H9A 5 7./F.6/H 3/8 /8.35 3 3 5 3 5 85 5 75 67 67 863H3A - 5./F.6/H 3/8 /8.35 3 3 5 - - - - - - 67 - - 863H9A 5./F - 3/8 5/3.5 3 95 35 35 5 5 9 67 67 863H8A 863H93A 5 7./F.6/H 3/8 5/3.5 85 65 63 5 55 5 67 67 863HA - 5./F.6/H 3/8 5/3.5 85 - - - - - - 67 - - 863H33A 5./F - 3/8 7/3.73 5 7 7 7 65 65 65 67 67 863H6A 863H33A 5 7./F.6/H 3/8 7/3.73 86 7 35 35 35 3 3 3 67 67 863HA - 5./F.6/H 3/8 7/3.73 86 7 - - - - - - 67 - - 863H95A 5./F - 3/8 9/3.88 85 7 53 5 7 8 6 67 67 863HA 863H333A 5 7./F.6/H 3/8 9/3.88 65 63 7 - - - - - - 67-863H5A 863H97A 5./F - For dimensions, consult factory. Dimensions: inches (mm) Ref. H K L P W ins 3.5.7.9.69.95 mm 77 3 3 68 5 3 ins 3..79.56.76.95 mm 79 5 7 5 5 ins 3..79.88.77.95 mm 8 5 8 7 5 Ref., 3, 5 K P W H L ANPT PIPE THREAD ( PLACES) Mounting Dimensions (/8" Pipe) (/" Pipe) (3/8" Pipe).3 [8].59 [5] MOUNTING HOLES.3 [9].87 [.] MOUNTING HOLES.57 [].75 [9] MOUNTING HOLES.69 [8] FLOW MOUNTING HOLES M5 THREAD.5 [6.] MIN.FULL THREAD DEPTH. HOLES FOR MOUNTING.87 [.] MOUNTING HOLES FLOW Note: Mounting holes will accept a standard #-3 machine screw. M5 THREAD.3 [7.6] MIN.FULL THREAD DEPTH HOLES FOR MOUNTING.8 [.6] MOUNTING HOLES FLOW M5 THREAD. [6] MIN. FULL THREAD DEPTH HOLES FOR MOUNTING 9

Direct Acting General Service Solenoid Valves Brass or Stainless Steel Bodies /8" to /" NPT 3/ 83 Features Designed for high flow and high pressure service Direct acting, requires no minimum operating pressure Metal seating materials 3-WAY Construction Valve Parts in Contact with Fluids Body Brass 3 Stainless Steel Disc 33 Stainless Steel (Metal) Seats Phosphor Bronze 33 Stainless Steel Core Tube Core and Plugnut Springs 35 Stainless Steel 3F Stainless Steel 3 Stainless Steel, 7-7PH, or Iconel Shading Coil Copper Silver Gaskets NBR PTFE NC 3 NO Electrical Watt Rating and Power Consumption Spare Coil Part Number U Standard Coil AC Explosionproof and Class of Insulation DC Watts Watts VA Holding VA Inrush AC DC F -. 3 76 - H 36. 8 6 33 35 8 Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Solenoid Enclosures Standard: RedHat II - Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9; RedHat - Explosionproof and Watertight, Types 3,, X, 7, and 9. See footnote on next page. For Optional Features, consult factory. Nominal Ambient Temp. Ranges Class F Coils AC: - F to 5 F (- C to 5 C) Class H Coils AC: - F to F (- C to 59 C) Class H Coils DC: - F to 77 F (- C to 5 C) ( F/ C occasionally) Approvals CSA certified, UL listed solenoid. Meets applicable CE directives.

3/ 83 3-WAY Specifications Pipe Orifice METAL SEATS AND DISCS Cv Flow Factor AC Operating Pressure Differential (psi) Air-Inert Gas DC Fluid Temp. F Brass Body NC/NO Univ. NC/NO Univ. AC DC Catalogue Number Stainless Steel Body Add Suffix "F" for NC, "G" for NO, "U" for Univ. ➀ ➂ Ref. Catalogue Number Watt Rating/ Class of Coil Insulation ➂ Ref. AC DC /8 /8.3 - - 5 5-8 EFX83D55MF/666 - - - 36./H /8 /8.3 55 3 - - - EFX83G55MF/666 - -./F - /8 3/6.35 - - 5 6-8 EFX83D3MF/666 - - - 36./H /8 3/6.35 5 5 - - - EFX83G3MF/666 - -./F - / 3/6.35 - - 5 6-8 EFX83D58MF/666 - - - 36./H / 3/6.35 5 5 - - - EFX83G58MF/666 - -./F - / /.5 - - 75 35-8 EFX83A8MF/666 - - - 36./H / /.5 9 9 - - - EFX83G8MF/666 - -./F - / /.5 5 - - - EFX83D6MF/666 ➁ - - 8/H - 3/8 /.5 - - 5 5-8 - - EFX83BMF/666-36./H 3/8 /.5 5 75 - - - - - EFX83GMF/666./F - 3/8 /.5 - - 75 35-8 EFX83A8MF/666 - - - 36./H 3/8 /.5 9 9 - - - EFX83G8MF/666 - -./F - 3/8 /.5 5 - - - EFX83D9MF/666 ➁ - - 8/H - 3/8 /.5 75 85 - - - - - EFX83BMF/666 ➁ 8/H - 3/8 5/6.75 - - - 8 EFX83D6MF/666 EFX83BMF/666-36./H 3/8 5/6.75 6 - - - EFX83G6MF/666 EFX83GMF/666./F - 3/8 3/8. - - 3 5-8 EFX83D7MF/666 EFX83B3MF/666-36./H 3/8 3/8. 75 35 - - - EFX83G7MF/666 EFX83G3MF/666./F - / 5/6.75 - - - 8 EFX83D68MF/666 EFX83B3MF/666 3-36./H / 5/6.75 6 - - - EFX83G68MF/666 EFX83G3MF/666 3./F - / 3/8. - - 3 5-8 EFX83D76MF/666 EFX83BMF/666 3-36./H / 3/8. 75 35 - - - EFX83G76MF/666 EFX83GMF/666 3./F - ➀ NC = Normally Closed: Exhaust pressure when de-energized. NO = Normally Open: Applies pressure when de-energized. Univ. = Universal: Pressure at any port. ➁ "EF" Prefix variations are suitable for enclosures Types 3,, 7 (C&D), and 9 (E) only and have a temperature range code T3A. ➂ For dimensions, consult factory. Dimensions: inches (mm) Ref. H K L P R S W T ins..89...6.3.6 3.3. mm 37 3 6 3 8 37 ins. 5.9.88..37.66. 3.3.88 mm 5 8 3 6 5 8 8 3 ins. 5.9.88.6.37.66. 3.55.88 mm 5 8 7 6 5 9 8 IMPORTANT: Valves must be mounted vertical and upright. Ref.,, 3 Flow Diagrams Normally Closed (Suffix "F") De-energized Energized SOL PRESS. SOL CYL. CYL. EXH. 3 Normally Open (Suffix "G") De-energized Energized PRESS. EXH. 3 SOL SOL EXH. EXH. CYL. CYL. PRESS. 3 Universal (Suffix "U") De-energized Energized PRESS. 3 SOL SOL 3 3

Air Piloted Spring Return Shutdown System General Service Solenoid Valves Brass or Stainless Steel Bodies Air and Inert Gas /" to /" NPT 3/ 836 Features Brass body construction for general atmospheres; stainless steel for corrosive atmospheres Can be internally piloted, or externally piloted When externally piloted, loss of electrical power or auxiliary air exhausts air from the actuator and shifts process valve to its original position When internally piloted, loss of electric power returns the valve to its original position 3-WAY Construction Valve Parts in Contact with Fluids Body Brass 36 Stainless Steel End Plate 3 Stainless Steel 36 Stainless Steel Seals and Discs Low Temp NBR NC E P A Core Tube 35 Stainless Steel NO Core Guide POM Shading Coil Copper Silver Electrical Watt Rating and Power Consumption Spare Coil Part Number Standard Coil and Class of Insulation Solenoid Enclosures AC Explosionproof (EF) Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Explosionproof (EV) DC VA Watts Watts Holding VA Inrush AC DC AC DC F.6. 5 5 76 387 76 77 Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts, AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Approvals CSA certified, UL listed solenoid. Meets applicable CE directives. Installation All valves may be mounted in any position. 36 Stainless Steel mounting brackets available from ASCO. Add suffix MB.

3/ 836 3-WAY Specifications Pipe Orifice CV Flow Factor Min. NORMALLY CLOSED (Closed when de-energized) Air Press.(psi) Catalogue Number Fluid Temp. F Watt Rating/ Class of Coil Insulation AC DC Brass Body Stainless Steel Ref. AC DC AC DC / 5/6.5 ➀ 5 EFX836GMF/5 EVX836G8MF/5 8./F.6/F 3/8 5/6.6 ➀ 5 EFX836GMF/5 EVX836G8MF/5 8./F.6/F 3/8 5/8 ➁ 5 EFX836G3MF/5-3 8./F.6/F / 5/8 ➁ 5 EFX836GMF/5 EVX836G8MF/5 3 8./F.6/F ➀ At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph below for pilot line pressure vs. mainline pressure. Minimum psi operating pressure differential when selection gasket is in the internal position. ➁ At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph below for pilot line pressure vs. mainline pressure. Minimum 5 psi operating pressure differential when selection gasket is in the internal position. IMPORTANT: Internal mode Minimum Operating Pressure Differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area and unrestricted. ASCO flow controls and similar components must be installed in the cylinder lines only. Dimensions: inches (mm) MAINLINE PRESSURE vs. PILOT LINE PRESSURE WHEN SELECTION GASKET IS IN EXTERNAL POSITION Ref. PILOT LINE PRESSURE (psi) 6 9 75 6 5 3 5 5 3 5 6 75 9 5 35 5 MAINLINE PRESSURE (psi) Ref. 3 INTERNAL PILOTING MODE FLOW DIAGRAMS De-Energized Energized PILOT EXH PILOT EXH (main) EXH (main) EXH CYL CYL PRESS PRESS EXTERNAL PILOTING MODE FLOW DIAGRAMS De-Energized with Auxiliary Pressure Applied (main) EXH PILOT EXH AUX Energized with Auxiliary Pressure Applied (main) EXH PILOT EXH AUX CYL CYL PRESS PRESS 3

Pilot Operated Quick Exhaust Solenoid Valves Brass or Stainless Steel Bodies /" NPT 3/ 837 Features Designed for quick venting to psi through the exhaust orifice 3-WAY Resilient seated poppets for tight shutoff Air is exhausted to quickly shift control valves Multi-industry applications Mountable in any position Construction Valve Parts in Contact with Fluids Body Brass 3 Stainless Steel Seals and Disc NBR (PA upper disc) Diaphragm CR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel and 7-7 PH Stainless Steel Shading Coil Copper Silver NC NO 3 Electrical Watt Rating and Power Spare Coil Standard Consumption Part Number Coil and AC Explosionproof Class of VA VA Insulation Watts Holding Inrush AC F. 5 5 386 Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). Must be specified when ordering. Other voltages available when required. Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) Approvals CSA certified, UL listed solenoid. Meets applicable CE directives. Important A Minimum Operating Pressure Differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only.

3/ 837 3-WAY Specifications Pipe Orifice Cv Flow Factor Operating Pressure Differential (psi) AC Fluid Temp. F Brass Body Stainless Steel Body Watt Rating/ Class of Coil Insulation Press. Exh. Press. Exh. Min. Air-Inert Gas AC Catalogue Number Ref. Catalogue Number Ref. AC NORMALLY CLOSED (Closed when de-energized) / 3/3 /..73 5 5 8 EFX837G35MF/883 EFX837G36MF/883./F NORMALLY OPEN (Open when de-energized) / 3/3 /.5.73 5 6 8 EFX837G53MF/883 - -./F Dimensions: inches (mm) Ref. H K L P W ins...55.5 3.5. mm 3 39 5 9 5 ins...53. 3.5. mm 39 5 89 5 Ref., 5

Direct Acting General Service Solenoid Valves Brass or Stainless Steel Bodies /8" to /" NPT 3/ 83 Features All NPT connections are in the valve body to allow in-line piping 3-WAY No Minimum Operating Pressure Differential required Broadest range of applications Mountable in any position Construction Valve Parts in Contact with Fluids Body Brass 33 Stainless Steel Seals and Disc NBR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel Shading Coil Copper Silver Disc-Holder POM Core Guide POM (. and 7. Watt only) NC NO 3 U Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC F.6. 5 5 386 387 386 387 F.6 7. 7 386 387 386 387 Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. 83 /" NPT Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number.) For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Approvals Brass Body: CSA certified, UL listed solenoid. Meets applicable CE directives. Stainless Steel: CSA certified. UL listed General Purpose Valves. Meets applicable CE directives. 6

3/ 83 3-WAY Specifications Pipe Orifice Cv Flow Factor UNIVERSAL OPERATION (Pressure at any port) Operating Pressure Differential (psi) Fluid Temp. F Brass Body ➁ Stainless Steel Body Watt Rating/ Class of Coil Insulation AC DC Air-Inert Gas Air-Inert Gas AC DC Catalogue Number ➀ Ref. Catalogue Number ➀ Ref. AC DC /8 /6.9 5 5 8 EFX83GMF/5 83G 7./F.6/F /8 3/3. 6 8 EFX83G3MF/5 83G 7./F.6/F /8 /8. 5 5 8 EFX83GMF/5 83G3 7./F.6/F / /6.9 5 75 5 EFX83G7MF/5 - -./F.6/F / /6.9 75 5 5 - - 83G3 3 7./F.6/F / 3/3. 6 5 EFX83G7MF/5 83G 3 7./F.6/F / /8.5 5 5 5 EFX83G76MF/5 83G 3 7./F.6/F / /6.35 5 EFX83G78MF/5 - -./F.6/F NORMALLY CLOSED (Closed when de-energized) /8 /6.9 6 8 EFX83G5MF/5 83G 7./F.6/F /8 3/3. 5 5 8 EFX83G6MF/5 83G5./F.6/F /8 /8. 85 6 8 EFX83G7MF/5 83G6./F.6/F / /6.9 6 5 EFX83G8MF/5 83G3 3 7./F.6/F / 3/3. 5 5 5 EFX83G8MF/5 83G 3./F.6/F / /8.5 85 6 5 EFX83G86MF/5 83G3 3./F.6/F / /6.35 5 5 5 EFX83G88MF/5 - -./F.6/F NORMALLY OPEN (Open when de-energized) /8 /6.9 35 6 8 EFX83G8MF/5 83G7 7./F.6/F /8 3/3. 5 8 EFX83G9MF/5 83G8./F.6/F /8 /8. 7 55 8 EFX83GMF/5 83G9./F.6/F / /6.9 35 6 5 EFX83G9MF/5 83G3 3 7./F.6/F / 3/3. 5 5 EFX83G9MF/5 83G 3./F.6/F / /8.5 7 55 5 EFX83G96MF/5 83G5 3./F.6/F / /6.35 3 5 EFX83G98MF/5 - -./F.6/F ➀ For dimensions, consult factory. ➁ Stainless steel constructions standard rated - F (- C) ambient temperature. EFX prefix and TPL # not required. 7

Direct Acting Direct Mount Pilot Valves Brass or Stainless Steel Bodies /" NPT 3/ 83 Direct Mount Features Mount directly to spring return actuators with NAMUR interface 3-WAY Same poppet valve performance as in standard 83 valves Integral breather block prevents ingestion of contaminates or corrosives Variety of flow and pressure ratings Mountable in any position Construction Valve Parts in Contact with Fluids ➀ Body Brass 33 Stainless Steel Seals and Discs Core Tube Core and Plugnut NBR 35 Stainless Steel 3F Stainless Steel Core Springs 3 Stainless Steel Shading Coil Copper Silver Disc-Holder POM NC 3 Core Guide POM (. and 7. watts only) ➀ Consult factory for constructioin details on catalogue numbers 83P7 and 83P7. Electrical Standard Coil and Class of Insulation DC Watts ➀ Watt Rating and Power Consumption Watts Spare Coil Part Number AC General Purpose Explosionproof VA Holding VA Inrush AC DC AC DC F.6 6. 6 3 38 383 38 383 F.6. 5 5 386 387 386 387 F.6 7. 7 386 387 386 387 Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. ➀ Consult factory for electrical information on Watt catalogue numbers 83P7 and 83P7. Solenoid Enclosures RedHat II Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number.) For Optional Features, consult factory. RedHat Next Generation Standard: Watertight, Types,, 3, 3S, 3R,, and X. Optional: Class I, Division for Hazardous Locations/Watertight. Meets Types through X and UL listed and CSA certified for Class I, Division, Groups A, B, C and D and Class II, Division, Groups F and G. (To order, add prefix EE to catalogue number.) Nominal Ambient Temp. Ranges RedHat II AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) RedHat Next Generation AC/DC: - F to F (- C to 6 C) Approvals 83: UL component and CSA certified. EFX83: UL component and CSA certified solenoid. 8

3/ 83 Direct Mount 3-WAY Specifications Pipe Orifice Cv Flow Factor NORMALLY CLOSED (Closed when de-energized) Operating Pressure Differential (psi) Watt Rating/ Air-Inert Gas Fluid Temp. F Brass Body Stainless Steel Body Class of Coil Insulation AC DC AC DC Catalogue Number Catalogue Number Ref. AC DC / /6.9 5 5 8 EFX83G7MF/5 EFX83G7MF/5 6./F.6/F / 3/3. 8 EFX83G7MF/5 EFX83G7MF/5 6./F.6/F / /6.9 6 8 EFX83G73MF/5 83G73 ➀ 7./F.6/F / 3/3. 5 5 8 EFX83G7MF/5 83G7 ➀./F.6/F / 3/3. 5 5 8 8 83P7 ➁ 83P7 ➁ 8 /H /H / /8. - 8 - EFX83G75MF/5 83G75 ➀ 7./F - ➀ Standard rated - F (- C) ambient temperature. EFX prefix and TPL # not required. ➁ RedHat Next Generation Valve. Dimensions inches (mm) Ref. Ref. Ref. 8 C B 3 D / NPT.9.95 / ANPT H.6.75 3.6 / ANPT 3 Ø. x.5 DEEP FOR POSITIONING DOWEL 3.5.85.7 FOR M5 SCREWS, PLACES.8 FOR.9-3 UNC-A &.9-3 UNF-A SCREWS, PLACES 9

Balanced Poppet Type High Flow Direct Acting Valves Brass, Aluminum and 36 Stainless Steel Bodies /" NPT 3/ 837 Features Designed for high flow piloting with no minimum operating pressure required; e.g. power plants, refineries, chemical processing 3-WAY Balanced Poppet construction for high flow at minimum power levels PTFE rider rings and graphite-filled seals reduce friction and eliminate sticking to provide exceptional service life 36 Stainless Steel construction for highly corrosive atmospheres NAMUR direct mount construction available. See specification chart Construction Valve Parts in Contact with Fluids Body Brass 36 Stainless Steel Aluminum Core Tube 35 Stainless Steel Stem and Insert 33 Stainless Steel Core and Plugnut 3F Stainless Steel O-ring Holder 3F Stainless Steel Springs 3 Stainless Steel Seals and Discs VMQ Rider Ring PTFE Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC F.6 76 387 76 387 F-NAMUR.6 76 387 76 387 Standard Voltages: /5-6, /5-6, /5-6, and 8/5-6, or 6,,,, and DC. U 3 Solenoid Enclosures Standard: For Brass and Aluminum Valves: Standard Solenoid enclosure is Types,,, 3, 3S,, and X. For 36 Stainless Steel valves: Standard Solenoid enclosure is Explosionproof and Watertight Types 3, 3S,, X, 6, and 6P. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF or, for Explosionproof Stainless Steel trim and hub on Brass-Bodied valves, add EV to catalogue number.) For Optional Features, consult factory. Nominal Ambient Temp. Ranges - F to 3 F (- C to 55 C) Approvals CSA certified. UL listed General Purpose Valves. Meets applicable CE directives.

3/ 837 3-WAY Specifications Pipe Orifice Cv Flow Factor Maximum Operating Pressure Differential (psi) Brass Body 36 Stainless Steel Body Watt Rating/ Class of Coil Insulation Ports - Ports -3 Air-Inert Gas Fluid Temp. F Catalogue Number Catalogue Number Ref. AC DC UNIVERSAL LOW-TEMPERATURE OPERATION (pressure at any port) - SIL 3 Certified by Exida ➀ / /.9.56 5 3 837G5./F.6/F / /.9.56 5 3 EV837G5./F.6/F ➀ Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. SIL 3 Certified by Exida, only valid when used as Normally Closed. Pipe Orifice Cv Flow Factor Maximum Operating Pressure Differential (psi) Aluminum Body Stainless Steel Body Watt Rating/ Class of Coil Insulation Ports - Ports -3 Air-Inert Gas Fluid Temp. F Catalogue Number Catalogue Number Ref. AC DC UNIVERSAL LOW-TEMPERATURE OPERATION - NAMUR Direct Mount / /.5.53 5 3 837G53 EV837G55./F.6/F Dimensions: inches (mm) FLOW DIAGRAMS Ref. OPERATION DE-ENERGIZED ENERGIZED NORMALLY CLOSED PRESSURE AT 3 3 3 NORMALLY OPEN PRESSURE AT 3 3 UNIVERSAL PRESSURE AT ANY PORT 3 3 IMPORTANT: Valves may be mounted in any position. Ref.

Pilot Operated High FLow RedHat II Spool Valves Brass and Stainless Steel Bodies /" NPT 3/ 855 Features Compact Spool Valve 3-WAY Single and dual solenoid constructions available Unique design combines hard T-seals and flexible o-rings, provides bubble-tight shutoff, resistance to dirt and multimillion cycle life controlling air or inert gas Construction Valve Parts in Contact with Fluids Body Brass 36L Stainless Steel End Cover (Spring end) Brass 36L Stainless Steel Spool Valve Internals Brass, POM Pilot End Covers Brass 36L Stainless Steel Core Tube Stainless Steel Core and Plugnut Stainless Steel Springs Stainless Steel Seals and Discs NBR Top Disc PA Core Guide POM Seat and Seat Insert Brass, POM Shading Coil Copper Rider Ring (low power) PTFE 3 3 3 3 Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC F.6. 5 5 386 387 386 387 Standard Voltages:,,, 8 volts AC, 6 Hz (, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Nominal Ambient Temp. Ranges Body Material Brass Stainless Steel Description AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Approvals CSA certified, UL listed solenoids. Meets applicable CE directives.

3/ 855 3-WAY Specifications Body Material Pipe Orifice Cv Flow Factor Single Solenoid Dual Solenoid Operating Pressure Operating Pressure Watt Rating/ Differential (psi) Fluid Differential (psi) Fluid Class of Coil Air-Inert Gas Temp. F Air-Inert Gas Temp. F Insulation Min. AC DC AC DC Catalogue Number Ref. Min. AC DC AC DC Catalogue Number Ref. AC DC Brass EF855G7 ➀➂ EF855G8 ➀ / /.86 3 5 3 5 36L Stainless Steel EV855G3 ➁ EV855G ➁./F.6/F ➀ Brass construction supplied standard with EF solenoid. ➁ Stainless steel construction supplied standard with EV solenoid. ➂ SIL 3 Certified by EXIDA - Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. Dimensions inches (mm) Series 855 NPT / L ➀ 5. (3) L ➀ 6.73 (7) H.38 () H. (8) W.77 (5) Ref. 3. (76.7).3 (5.6) / NPT ➀ Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H 3 /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand 3

Pilot Operated Piston/Poppet Solenoid Valves Brass Body /" to " NPT / 83 Features Sturdy, robust construction Piston-operated poppet design provides high flow Wide range of sizes and flow rates Single or dual solenoid constructions Dual solenoid can be shifted with a momentary signal and remain in position even if electrical power is lost Mountable in any position -WAY Construction Valve Parts in Contact with Fluids Body Brass Seals and Disc NBR Core Tube 35 Stainless Steel Core and Plugnut 3F Stainless Steel Springs 3 Stainless Steel / 7-7PH Stainless Steel Shading Coil Copper Pilot Seat Cartridge and Disc-Holder POM Shaft Gasket PA B E B E A P A P Electrical Standard Coil and Class of Insulation DC Watts Watt Rating and Power Consumption AC Spare Coil Part Number Explosionproof Watts VA Holding VA Inrush AC DC F.6 6. 6 3 38 383 F.6. 5 5 386 387 F.6 7. 7 386 387 Dual Solenoid Operation: Minimum coil on-time for dual solenoid valves is.3 seconds on air service and. seconds on liquids. Caution: Do not energize both solenoids simultaneously. Standard Voltages:,,, 8 volts AC, 6 Hz (or, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Nominal Ambient Temp. Ranges AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Approvals CSA certified solenoid. Meets applicable CE directives. Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Important A Minimum Operating Pressure Differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. Loss of air pressure may allow valve to shift on dual solenoid constructions.

/ 83 Specifications -WAY Pipe SINGLE SOLENOID Orifice Press. Cv Flow Factor Exh. ➀ Min. Operating Pressure Differential (psi) AC Air-Inert Gas DC Fluid Temp. F Brass Body Air-Inert Gas AC DC Catalogue Number Watt Rating/ Class of Coil Insulation Ref. AC DC / /.8. 3 5 5 8 5 EFX83G7MF/8897./F.6/F 3/8 3/8.. 5 5 8 5 EFX83G7MF/8897./F.6/F / 3/8.. 5 5 8 5 EFX83G7MF/8897./F.6/F 3/ 3/ 5. 5.6 5 5 8 5 EFX83G76MF/8897 3./F.6/F 3/ 5. 5.6 5 5 8 5 EFX83G78MF/8897 3./F.6/F DUAL SOLENOID ➀ / /.8. 3 5 5 8 EFX83GMF/8897 6./F.6/F 3/8 3/8.. 5 5 8 EFX83G8MF/8897 6 6./F.6/F / 3/8.. 5 5 8 EFX83G8MF/8897 6 6./F.6/F ➀ On 5 hertz service, the watt rating for the 6./F solenoid is 8. watts. Dimensions inches (mm) Ref. ØD E F G H J K L N P W X Y Z Exhaust Pipe ins. Ø.8.56..88.8.3.5 3.3.7 3..75..56.8 3/8 mm Ø 7. 6 8 6 55 8 8 79 36 3/8 ins. Ø.3.75 3..63.6.5.97 3.8.83.9 6.6.88.9.8 / mm Ø 8.6 9 79 67 3 38 5 8 75 5 7 8 / 3 ins. Ø.3.3 3.8 3.88.86.9.3.56.56 3.3 8.5..63.6 mm Ø 8.6 3 97 99 3 53 59 6 39 8 5 67 3 ins. Ø.8.56..88.3.3.5 3.3.7 3.38.8..56.8 3/8 mm Ø 7. 6 8 6 6 8 8 86 36 3/8 6 ins. Ø.3.75 3..63.5.5.5 3.8.83 3.38 6.6.88.9.8 / mm Ø 8.6 9 79 67 38 6 8 86 5 7 8 / Ref - 3 Ref - 6 Ref. - 6 / NPT N X E PRESS EXH. MTG. HOLES DIA D / NPT H P K L F K P H CYL B J CYL A PRESS EXH. Z Y G W PRESS EXH. 5

Pilot Operated High Flow RedHat II Spool Valves Brass and Stainless Steel Bodies /" NPT 5/ 5/3 855 Features Compact Spool Valve Single and dual solenoid constructions available Unique design combines hard T-seals and flexible o-rings, provides bubble-tight shutoff, resistance to dirt and multimillion cycle life controlling air or inert gas -WAY Construction Valve Parts in Contact with Fluids Body Brass 36L Stainless Steel End Cover (Spring end) Brass 36L Stainless Steel Spool Valve Internals Brass, POM Pilot End Covers Brass 36L Stainless Steel Core Tube Stainless Steel Core and Plugnut Stainless Steel Springs Stainless Steel Seals and Discs NBR Top Disc PA Core Guide POM Seat and Seat Insert Brass, POM Shading Coil Copper Rider Ring (low power) PTFE 5/ 5 3 5 3 5 3 5 3 Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption AC Spare Coil Part Number Explosionproof VA Inrush AC DC DC Watts Watts VA Holding F.6. 5 5 386 387 Standard Voltages:,,, 8 volts AC, 6 Hz (, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Nominal Ambient Temp. Ranges Body Material Brass Stainless Steel Description AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. Approvals CSA certified, UL listed solenoids. Meets applicable CE directives. 6

5/ 5/3 855 Specifications Body Material Pipe Orifice Cv Flow Factor Single Solenoid Dual Solenoid Operating Pressure Operating Pressure Watt Rating/ Differential (psi) Fluid Differential (psi) Fluid Class of Coil Air-Inert Gas Temp. F Air-Inert Gas Temp. F Insulation Min. AC DC AC DC Catalogue Number Ref. Min. AC DC AC DC Catalogue Number Ref. AC DC -WAY Brass 5/ EF855G9 ➀ EF855G ➀ / /.86 3 5 3 5 36L Stainless Steel 5/ EV855G ➁ EV855G ➁./F.6/F ➀ Brass construction supplied standard with EF solenoid. ➁ Stainless steel construction supplied standard with EV solenoid. Dimensions inches (mm) Series 855 NPT / L ➀ 5.63 (3) L ➀ 7. (83) H.38 () H. (8) W.77 (5) ➀ Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Ref. 3. (76.7).3 (5.6) / NPT Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H H 3 /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand 7

Pilot Operated High Flow Direct Mount Spool Valves Brass and Stainless Steel Bodies /" NPT 3/ 5/ 855 Direct Mount Features Compact Spool Valve convertible from 3/ to 5/ with flow plates Mount directly to actuators with NAMUR interface per VDI/VDE 385 Single and dual solenoid constructions available Integral Breather Block vents to spring side of actuator to exhaust, preventing corrosion of the actuator Unique design combines hard T-seals and flexible o-rings, provides bubble-tight shutoff, resistance to dirt and multimillion cycle life controlling air or inert gas -WAY Construction Valve Parts in Contact with Fluids ➀ Body Brass 36L Stainless Steel End Cover (Spring end) Brass 36L Stainless Steel Spool Valve Internals Brass, POM Pilot End Covers Brass 36L Stainless Steel Core Tube Stainless Steel Core and Plugnut Stainless Steel Springs Stainless Steel Seals and Discs NBR Top Disc PA Core Guide POM Seat and Seat Insert Brass, POM Shading Coil Copper Rider Ring (low power) PTFE ➀ Consult factory for construction details on catalogue numbers EE855P and EE855P9. 3/ 5/ 3 5 3 5 3 5 5 3 Electrical Standard Coil and Class of Insulation Solenoid Enclosures ➀ Watt Rating and Power Consumption AC Spare Coil Part Number Explosionproof VA Inrush AC DC DC Watts Watts VA Holding F.6. 5 5 386 387 Standard Voltages:,,, 8 volts AC, 6 Hz (, volts AC, 5 Hz). 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. ➀ Consult factory for electrical information and standard voltages on catalogue numbers EE855P and EE855P9. RedHat II Standard: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. For Optional Features, consult factory. RedHat Next Generation Standard: Class I, Division for Hazardous Locations/Watertight. Meets Types through X and UL listed and CSA certified for Class I, Division, Groups A, B, C and D and Class II, Division, Groups F and G. Nominal Ambient Temp. Ranges RedHat II AC: - F to 5 F (- C to 5 C) DC: - F to F (- C to C) RedHat Next Generation AC/DC: - F to F ( C to 6 C) Approvals CSA certified, UL listed solenoids. Meets applicable CE directives. 8

3/ 5/ 855 Direct Mount -WAY Specifications Body Material Pipe Orifice Cv Flow Factor Operating Pressure Differential (psi) Air-Inert Gas Min. AC Single Solenoid Fluid Temp. F Catalogue DC AC DC Number Ref. Min. Operating Pressure Differential (psi) Air-Inert Gas AC Fluid Temp. F Dual Solenoid Watt Rating/ Class of Coil Insulation Catalogue DC AC DC Number Ref. AC DC Brass 3/, 5/ ➂ / /.86 3 5 EF855G3 ➃ 3 5 EF855G ➃./F.6/F 36L Stainless Steel 3/, 5/ ➂ / /.86 3 5 5 8 8 EE855P9 ➀ ➁ /H /H / /.86 3 5 EV855G9 ƒ 3 5 EV855G ƒ./f.6/f ➀ RedHat Next Generation Valve. ➁ Consult factory for dimensions. ➂ /8 inch NPT exhaust. ➃ Brass construction supplied with EF solenoid. ƒ Stainless steel construction supplied standard with EV solenoid. Dimensions inches (mm) Series 855 NPT / L ➀.96 (6) L ➀ 6.5 (65) H.38 () H.57 () W.77 (5) ➀ Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Ref. H H 3. (76.7).3 (5.6) 3 /8 NPT / NPT / NPT Add Suffix MO MI MH MS Optional Manual Operators ➀ Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot Momentary push in by hand Push and turn to lock by hand ➀ For construction references and only 855 NAMUR Footprint.95 ().6 (3) H H 3. (76.7).3 (5.6).95 () W 855 NAMUR Footprint Ref. (855) / NPT (8553) / NPT 5 3.6 (3) / NPT /8 NPT AUX. PRESSURE PORT L Add Suffix MO MI MH L Optional Manual Operators Series 855 (5/3) NPT / L ➀ - L ➀ 7. (89) H.38 () H.57 () W.77 (5) ➀ Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot Momentary push in by hand W /8 NPT AUX. PRESSURE PORT L MS Push and turn to lock by hand L 9

Direct Acting Pilot Operated Cryogenic and Liquid CO Valves Brass Body /8" to /" NPT / Cryo/ LCO Features LT suffix valves are built to control cryogenic fluids, including liquid nitrogen (-3 F/-9 C), liquid argon (-33 F/-8 C), and liquid oxygen (-97 F/-8 C) All suffix LT valves are degreased, cleaned, tested free of moisture, and black light tested for hydrocarbons Liquid CO valves are suitable for remote mounting or for direct mounting to the refrigerated component by using four-hole bracket, provided Construction Body: Cryogenic Valves Valve Parts in Contact with Fluids Brass % ) SPECIAL SERVICE VALVES Body: LCO Valves Seals Disc Core and Plugnut Core Spring Shading Coil Seats Nickel-Plated Brass PTFE and/or Clad Copper/UR PTFE/UR (86 only) 3F Stainless Steel or 9 FM Alloy 3 Stainless Steel Copper Stainless Steel (86 Series) NC Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Solenoid Enclosures Spare Coil Part Number AC General Purpose Explosionproof DC Watts Watts VA Holding VA Inrush AC DC AC DC F.6. 3 7 386 387 386 387 F 8.6 3.8 7 3 38 383 38 383 F - 7. 3 6 386-386 - H.6 7. 3 6 388 389 388 389 Standard Voltages:,,, 8 volts AC, 6 Hz. 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number.) See Optional Features Section for other available options. Nominal Fluid Temp. Ranges AC Cryogenic Valves: -3 F to 5 F (-96 C to 66 C) DC Cryogenic Valves: -3 F to F (-96 C to 9 C) All Liquid CO Valves: -75 F to F (-59 C to 9 C) Refer to Engineering Section for details. Nominal Ambient Temp. Ranges AC Construction: - F to 5 F (- C to 5 C) 86/863 Series: - F to 3 F (- C to 55 C) DC Construction: - F to F (- C to C) 86/863 Series: - F to 3 F (- C to 55 C) Refer to Engineering Section for details. Approvals CSA certified. Meets applicable CE directives. Refer to Engineering Section for details. 3

/ Cryo/ LCO SPECIAL SERVICE VALVES Specifications (English units) Operating Pressure Differential (psi) Watt Rating/ Class of Coil Pipe Orifice Cv Insulation Flow Factor Min. AC DC @ F DC @ 3 F Catalogue Number Ref. AC DC CRYOGENIC SERVICE - NORMALLY CLOSED (Closed when de-energized) /8 /8.35 55 75 68 863HLT./F.6/H /8 /8.35 5 3 86H5LT 7./F.6/H / /8.35 55 75 68 86H3LT./F.6/H / /8.35 5 3 86HLT 7./F.6/H / 7/3.73 8 3 86H8LT./F.6/H / 7/3.73 86HLT 7./F.6/H / 9/3.88 8 86HLT./F.6/H / 9/3.88 58 7 8 86HLT 7./F.6/H 3/8 /8.35 55 75 68 863H3LT./F.6/H 3/8 /8.35 5 3 863H5LT 7./F.6/H 3/8 7/3.73 8 3 863HLT./F.6/H 3/8 7/3.73 9 863H6LT 7./F.6/H 3/8 9/3.88 8 863H5LT./F.6/H 3/8 9/3.88 58 7 8 863HLT 7./F.6/H / 5/8 3.8 9 5-8GLT 3 7./H.6/H 3/ 3/ 5.8 9 5-8G3LT 3 7./H.6/H 3.5 5-8G78LT 7./F.6/H / /8 5 5-8G8LT 5 7./F.6/H / /.5 5-8G8LT 6 7./F.6/H LIQUID CO SERVICE - NORMALLY CLOSED (Closed when de-energized) /8 3/6.6-86G9 7 3.8/F 8.6/F /8 3/3. 3 3-86G 7 3.8/F 8.6/F Must use tubing with an I.D. no larger than the outlet port orifice to locate the refrigeration point downstream and to prevent freezing of the CO inside the valve. For 86 & 863 Series, AC pressure ratings are at 3 F ambient; for all other series, AC pressure ratings are at 5 F. Consult factory for dimensions. Specifications (Metric units) Operating Pressure Differential (bar) Watt Rating/ Class of Coil Pipe Orifice Kv Flow Insulation Factor (mm) (m 3 /h) Min. AC DC @ C DC @ 55 C Catalogue Number Ref. AC DC CRYOGENIC SERVICE - NORMALLY CLOSED (Closed when de-energized) /8 3..3 5 5 863HLT./F.6/H /8 3..3 7 9 8 86H5LT 7./F.6/H / 3..3 5 5 86H3LT./F.6/H / 3..3 7 9 8 86HLT 7./F.6/H / 5.6.63 3 86H8LT./F.6/H / 5.6.63 7 3 3 86HLT 7./F.6/H / 7..76 3 86HLT./F.6/H / 7..76 86HLT 7./F.6/H 3/8 3..3 5 5 863H3LT./F.6/H 3/8 3..3 7 9 8 863H5LT 7./F.6/H 3/8 5.6.63 3 863HLT./F.6/H 3/8 5.6.63 6 3 3 863H6LT 7./F.6/H 3/8 7..76 3 863H5LT./F.6/H 3/8 7..76 863HLT 7./F.6/H / 6 3. 6 3-8GLT 3 7./H.6/H 3/ 9 5 6 3-8G3LT 3 7./H.6/H 5.6 5 7-8G78LT 7./F.6/H / 9 3 5 7-8G8LT 5 7./F.6/H / 3 9 5 7-8G8LT 6 7./F.6/H LIQUID CO SERVICE - NORMALLY CLOSED (Closed when de-energized) /8.5 69 69-86G9 7 3.8/F 8.6/F /8.7-86G 7 3.8/F 8.6/F Must use tubing with an I.D. no larger than the outlet port orifice to locate the refrigeration point downstream and to prevent freezing of the CO inside the valve. For 86 & 863 Series, AC pressure ratings are at 55 C ambient; for all other series, AC pressure ratings are at 5 C. 3

Universal Operation Manual Reset Solenoid Valves Brass or Stainless Steel Bodies /" to /" NPT 3/ 838 83 Manual Reset Features High flow/high-pressure bodies with manual reset to prevent inadvertent valve start-up Once tripped, can only be manually reset Electrically Tripped (trips when energized) or No Voltage Release (trips when de-energized) Available for Latched Open or Latched Closed operation Ideal for controlling critical processes Construction Valve Parts in Contact with Fluids Body Brass Stainless Steel Stem 33 Stainless Steel Springs 3 Stainless Steel Pilot Seat Cartridge POM (when listed) Disc, Diaphragm, Seat NBR, PA, PTFE, or Stainless Steel, as listed SPECIAL SERVICE VALVES Electrical Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part Number VA Inrush AC DC AC DC Watts Watts VA Holding F - 5 96 9957 - H 36. - - - - 8 Standard Voltages:,,, 8 volts AC, 6 Hz. 6,,,, volts DC. Must be specified when ordering. Other voltages are available when required. Solenoid Enclosures Standard: Explosionproof and Watertight, Types 3, 7 (C and D), and 9. For Optional Features, consult factory. Nominal Ambient Temp. Ranges AC: - F to F (- C to C) DC: - F to 77 F (- C to 5 C) Approvals CSA certified solenoid. Some constructions meet shock and vibration ISA S7.3C. Operation Alternatives Electrically Tripped Manually move the lever to the latched position with the solenoid de-energized. Trips when solenoid is energized. Once tripped, the lever may be cycled causing the valve discs to open and close. No Voltage Release Manually move the lever to the latched position with the solenoid energized. Trips when solenoid is de-energized. Once tripped, the lever may be cycled causing the valve discs to open and close. 3

3/ 838 83 Manual Reset SPECIAL SERVICE VALVES Specifications Pipe Orifice Cv Flow Factor Watt Rating/ Operating Pressure Fluid ➂ Class of Coil Differential (psi) Temp. F No Voltage Release Electrically Tripped Flow Insulation Min. AC DC AC DC Catalogue Number Catalogue Number Ref. Diagram AC DC UNIVERSAL OPERATION (Except as Noted ➀ ), Brass Body with NBR Disc/Diaphragm (CA Pilot Cartridge) for Air-Inert Gas. This group of valves meets shock and vibration ISA S7.3C. / /6.38 5 5 8 8 EFX838BMF/7687 EFX83BMF/7687 B /F 36./H / 5/8 ➃ 5 5 8 8 EFX838CMF/7687 ➀➁ EFX83CMF/7687 ➀➁ C /F 36./H UNIVERSAL OPERATION, Brass Body with Stainless Steel Seats and Discs for Air-Inert Gas / /.5 5 5 EFX838MF/7687 EFX83MF/7687 A /F 36./H UNIVERSAL OPERATION, Stainless Steel Body with FKM Discs for Air-Inert Gas / /8. 5 5 8 8 EFX838AMF/7687 EFX83AMF/7687 B /F 36./H UNIVERSAL OPERATION, Stainless Steel Body with Stainless Steel Seats and Discs for Corrosive Service / 5/6.75 5 - - EFX8387MF/757 EFX837MF/7687 5 A /F - / 5/6.75-5 - EFX8387MF/7687 EFX837MF/7687 5 A - 36./H ➀ When ordering, specify suffix "F" for Normally Closed construction or Suffix "G" for Normally Open construction. ➁ Supplied with CA pilot cartridge. ➂ For dimensions, consult factory. ➃ -5 mainline pressure. Valve is externally piloted and requires a minimum pilot/auxiliary pressure of 5- psi. See graph below for mainline vs. pilot line pressure requirements. Flow Diagrams PILOT LINE PRESSURE (psi) 6 9 75 6 5 3 5 MAINLINE PRESSURE vs. PILOT LINE PRESSURE WHEN SELECTION GASKET IS IN EXTERNAL POSITION 5 3 5 6 75 9 5 35 5 MAINLINE PRESSURE (psi) Electrically Tripped and No Voltage Release Constructions Flow Diagram A Latched Unlatched Flow Diagram B Latched Unlatched Port Port 3 3 Port Port 3 Port Port 3 Flow Diagram C Normally Open Normally Closed Unlatched Latched Unlatched Latched A (Cyl.) A (Cyl.) A (Cyl.) A (Cyl.) E (Exh.) P (Press.) E (Exh.) P (Press.) E (Exh.) P (Press.) E (Exh.) P (Press.) 33

. W Low Power Solenoid Valves Brass or Stainless Steel Bodies /" to " NPT / 3/ / Low Power Features Moulded one-piece solenoid with highly efficient solenoid cartridge and special low wattage coil Designed for use in automation of plant control systems to provide: - PLC compatibility - Reduced battery drain - Reduced heat rise - Reduced wiring cost Wide selection includes / normally closed, 3/ normally closed (including Quick Exhaust), 3/ universal, and / Air or inert gas only Lower-cost alternative to intrinsically safe valves in critical applications not requiring a safety barrier Construction Valve Parts in Contact with Fluids Body Brass Stainless Steel Seals and Discs NBR Sleeve 3L Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel Pilot Seat Cartridge (Series 836 & 83 only) POM Rider Rings PTFE Spring Retainer POM Electrical Nominal Ambient Temp. Ranges Series Body Material Temperature Range 836/5 837 83/8897 Brass & Stainless Steel - F to F (- C to 6 C) 83 Stainless Steel - F to F (- C to 6 C) SPECIAL SERVICE VALVES Ambient Insulation Description Wattage Temp. T Code Class TPL Standard Ambient Version.W F(6 C) T6 F - High Ambient Version.8W 79 F(8 C) T5 F TPL #333 Surge Suppression Version.7W F(6 C) T5 F - Surge Suppression High Ambient Version Description Standard Ambient Version High Ambient Version Surge Suppression Version Surge Suppression High Ambient Version Wattage.W.8W.7W.W.W 79 F(8 C) T5 F TPL #333 Voltage Min. Pull 3way Drop way Drop Coil resistance (DC) In (ma) Out (ma) Out (ma) @68 F( C) (ohms) V 83.5 3.9 3. V. 7..6 8V. 3.6.8 6 V 8.7..3 V 9.3 5.7 3.6 8 V 7.9 8..8 3 8V...9 6 V 9.3 5.7 3.6 8 V 7.9 8..8 3 8V.7 3.8.9 7 V 5.3 7.6. 6 V 5. 9.. 7 8V...9 6 VDC Spare Coil P/N Standard Ambient Temp. Version High Ambient Temp. Version General Purpose 387-9-D* 387-98-D* Explosionproof 387-9-D* 387-95-D* Explosionproof, Corrosion Resistant 77-9-D* 77-95-D* Explosionproof, Surge Suppression 766-6-D* 766-6-D* Explosionproof, Corrosion Resistant, Surge Suppression 767-6-D* 767-6-D* 836/7596 836/ Approvals Stainless Steel -59 F to F (-5 C to 6 C) 837/83: UL listed General Purpose Valves (MP68), CSA certified (38). Meets applicable CE directives. 833/8897, 836 as 5,7596 & : UL listed solenoid (Hazardous Location Classified), CSA certified solenoid only, nonincendive for Class I, Division UL E6 for - F (- C). Meets applicable CE directives. 837/83 with EF/EV Prefix: UL listed (Hazardous Location Classified), Class I, Division UL E559. Certified CSA valve (3976). Meets applicable CE directives. SIL 3 capable per IEC 658 on 836 const. Third party certification provided by EXIDA. Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number. For explosionproof with 36 Stainless Steel hub and trim, specify prefix EV.) Surge suppression coils also available MF prefix. For Optional Features, consult factory. 3

/ 3/ / Low Power Specifications SPECIAL SERVICE VALVES Pipe Orifice Pressure to Cylinder Cv Flow Factor / VALVES, NORMALLY CLOSED, with NBR Disc Operating Pressure Differential (psi) Air-Inert Gas Fluid and Ambient Temp. F Brass Body Cylinder to Exhaust Min. Catalogue Number Ref. Stainless Steel Body Catalogue Number / 3/8 3. 5 5 - - 83G3 3/ VALVES, NORMALLY CLOSED (Closed when de-energized) with NBR Disc - SIL 3 Certified by Exida» / 5/6.5.5 ➃ 5 EFX836G3MF/5 ➂ 3 EVX836G38MF/5 ➂ 3 / 5/6.5.5 ➆ - - EVX836G38MB/7596 ➇ 3 / 5/6.5.5 5 ➅ - - EVX836G38MB/ ➇ 3 3/8 5/6.6.6 ➃ 5 EFX836G3MF/5 ➂ 3 EVX836G38MF/5 ➂ 3 3/8 5/6.6.6 ➆ - - EVX836G38MB/7596 ➇ 3 3/8 5/6.6.6 5 ➅ - - EVX836G38MB/ ➇ 3 3/8 5/8 ƒ 5 EFX836G33MF/5 ➂ 3A - - / 5/8 ƒ 5 EFX836G3MF/5 ➂ 3A EVX836G38MF/5 ➂ 3A 3/ VALVES, UNIVERSAL (Normally Closed or Normally Open) "Quick Exhaust" with NBR Diaphragm and NBR Disc / ➁.8.73 5 5 837G37 ➀ 6 837G38 ➀ 7 / VALVES, Brass Body with NBR Disc Ref. Pipe Orifice Cv Flow Factor Pressure to Cylinder to Cylinder Operating Pressure Differential (psi) Air-Inert Gas Fluid and Ambient Temp. F Single Solenoid Exhaust Min. Catalogue Number Ref. Dual Solenoid Catalogue Number / /.8 3 5 EFX83G37MF/8897 ➀➂ 9 EFX83G3MF/8897 ➂ 3/8 3/8.. 5 EFX83G37MF/8897 ➀➂ EFX83G38MF/8897 ➂ / 3/8.. 5 EFX83G37MF/8897 ➀➂ EFX83G38MF/8897 ➂ 3/ 3/ 5. 5.6 5 EFX83G376MF/8897 ➀➂ 3 - - 3/ 5. 5.6 5 EFX83G378MF/8897 ➀➂ 3 - - ➀ There are two exhaust flows in the exhaust mode (pilot and main). The pilot exhaust must be connected to the main exhaust when the air or inert gas cannot be exhausted to atmosphere. ➁ For "Quick Exhaust" valves, pressure port is /6", exhaust port is /". ➂ IMPORTANT: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. ➃ At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph on page 36 for auxiliary pressure vs. mainline pressure. Minimum psi operating pressure differential when selection gasket is in the internal position. ƒ At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph on page 36 for auxiliary pressure vs. mainline pressure. Minimum 5 psi operating pressure differential when selection gasket is in the internal position. ➅ IMPORTANT: Internal Pilot Construction: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. ➆ IMPORTANT: External Pilot Construction: Zero minimum operating pressure differential when the gasket is in the external position and proper auxiliary air pressure is applied. See graph on page 36 for pilot line pressure vs. mainline pressure. ➇ At -59 F (-5 C), these constructions have a reduced life expectancy. Consult factory for details.» SIL 3 Certified by Exida, only valid when used as Normally Closed. Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. IMPORTANT: Supervisory and leakage current above the drop out current of 7mA for V DC will cause improper operation. Consult your local ASCO sales office for additional assistance. Ref. 35

/ 3/ / Low Power Dimensions: inches (mm) Ref. 3A Ref. 6. 7 SPECIAL SERVICE VALVES Ref. 3 MAINLINE PRESSURE vs. PILOT LINE PRESSURE WHEN SELECTION GASKET IS IN EXTERNAL POSITION PILOT LINE PRESSURE (psi) 6 9 75 6 5 3 5 5 3 5 6 75 9 5 35 5 MAINLINE PRESSURE (psi) 36

/ 3/ / Low Power Dimensions: inches (mm) SPECIAL SERVICE VALVES Ref. Dia D E F G H J K L N P W X Y Z 9 ins. Ø.8.56..88.67.3.3 3..7 3.7.75..56.8 mm 7 6 8 9 6 58 79 8 95 36 ins. Ø.3.76 3..6.89.5. 3.8.83 3.77 6.6.86.89.83 mm 9 6 79 67 8 38 7 8 9 5 8 9 ins. Ø.3.76 3..6.65.5. 3.8.83 3.53 6.6.86.89.83 mm 9 35 97 99 38 53 5 6 99 5 67 3 ins. Ø.8.56..88 5.6.3.7 3..7..8..56.8 mm 7 6 8 9 6 69 79 8 5 36 3 ins. Ø.3.78 3..6 5.7.5.9 3.9.8.6 6.6.88.9.8 mm 9 6 79 67 3 38 63 8 6 5 8 9 Ref. 9,,,, 3 Exhaust Pipe 3/8 / / 3/8 Ref. 37

.55 W Low Power Solenoid Valves Brass or Stainless Steel Bodies /" to /" NPT / 3/ 5/ 5/3 Low Power Features Moulded one-piece solenoid with highly efficient solenoid cartridge and.55 W low wattage coil Standard ambient temperature of 9 F (65 C) Optional 76 F (8 C) high ambient temperature version Designed for use in automation of plant control systems to provide: - PLC and DCS compatibility for BUS network and traditional wiring - Reduced temperature rise - Increase battery life - Reduce wiring cost - Energy savings Wide selection includes / normally closed, 3/ universal, 5/, and 5/3 Construction Valve Parts in Contact with Fluids Body Brass Stainless Steel Seals and Discs PUR, NBR, FKM, CR, as listed Sleeve 3L Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel Rider Rings PTFE Spring Retainer POM Electrical Description Wattage Ambient Temp. T Code Insulation Class Prefix Standard Ambient Version.55 W 9 F (65 C) T6 F - High Ambient Version.7 W 76 F (8 C) T6 H HT Surge Suppression Version.75 W 9 F (65 C) T6 F MF Description Wattage Standard Ambient Version.55W High Ambient Version.7W Surge Suppression Version.75W Min. Pull In (ma) Drop Out (ma) Coil Resistance @68 F ( C) (ohms) Voltage (DC) V 3.8 55 V 7.89 5 8V 8.5.5 8 5V** 3..7 7, V 37.9 6 V 9.98 83 8V 9.7.5 385 5V** 3.7. 5 V. 65* V 9.98 83* 8V 9.7.5 385* 5V** 3.7. 5* Note: * Surge suppression contains diode bridge. ** Not for battery applications VDC Spare Coil P/N Standard Ambient Temp. Version High Ambient Temp. Version General Purpose 389-96-D* 389-96-D* Explosionproof 387-93-D* 389-96-D* Explosionproof, Corrosion Resistant 77-99-D* 79-96-D* Explosionproof, Surge Suppression 766-6-D* Not Available Explosionproof, Corrosion Resistant, Surge Suppression 767-6-D* Not Available Note: For VDC, 8VDC and 5VDC coil PN consult factory 83 Solenoid Enclosures Standard: Watertight, Types,, 3, 3S,, and X. Optional: Explosionproof and Watertight, Types 3, 3S,, X, 6, 6P, 7, and 9. (To order, add prefix EF to catalogue number. For explosionproof with 36 Stainless Steel hub and trim, specify prefix EV.) Surge suppression coils also available MF prefix. For Optional Features, consult factory. Approvals UL & CSA Approved for Class I Div. Locations & Class I Div. Nonincendive. UL Listed General Purpose Valves. Meets applicable CE directives. Brass 855 & 8553: UL listed solenoid (Hazardous Location Classified, E6), CSA certified solenoid only (3976), nonincendive for Class I, Division, - F (- C). Meets applicable CE directives. Stainless Steel 855 with EF prefix: UL listed (Hazardous Location Qualified), Class I Division UL E559. Certified CSA valve (3976). Meets applicable CE directives. SIL 3 capable per IEC 658 on 83, 836, 855, and 8553 const. Third party certification provided by EXIDA. 38 SPECIAL SERVICE VALVES

/ 3/ 5/ 5/3 Low Power SPECIAL SERVICE VALVES Nominal Ambient Temp. Ranges Specifications P ipe Series Body Material Normal Temperature Range High Ambient Temp. Version 8553 Stainless Steel 855 Brass Orifice Cv Flow Factor Pressure to Cylinder to Cylinder - F to F (- C to 6 C) Operating Pressure Differential (psi) Air-Inert Gas Fluid and Ambient Temp. F Not Available 855 Stainless Steel 83 - F to 9 F (- C to 65 C) Low Limit is the same as Brass / Stainless Steel Normal Temperature Ratings, 837 but High Limit is 76 F (8 C) 836 Stainless Steel -59 F to 9 F (-5 C to 65 C) Brass Body Important These solenoids are intended for use on clean, dry air or inert gas filtered to 5 microns or better. To prevent freezing, the dew point of the media should be at least 8 F (-8 C) below the minimum temperature to which any portion of the clean air or gas system could be exposed. Instrument air in compliance with ANSI/ISA Standard S7.3-975 (R98) exceeds the above requirements and is, therefore, an acceptable medium for these valves. Stainless Steel Body Exhaust Min. Catalogue Number Ref. Catalogue Number Ref. 3/ VALVES, UNIVERSAL OPERATION (Normally Closed or Normally Open) with NBR Disc SIL 3 Certified by Exida ➁ / /.6.6 3/5 9 83H3 83H3 3/ VALVES, NORMALLY CLOSED (Closed when de-energized) with NBR Disc - SIL 3 Certified by Exida ➁ / 5/6.5.5 ➂ 9 - - EV836H385 ➄ 5 / 5/6.5.5 5 9 - - EV836H386 ➄ 5 3/8 5/6.6.6 ➂ 9 - - EV836H387 ➄ 5 3/8 5/6.6.6 5 9 - - EV835H388 ➄ 5 Normally closed = 3 psi. Normally open = 5 psi. ➁ SIL 3 Certified by Exida, only valid when used as Normally Closed. Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. ➂ IMPORTANT: Internal Pilot Construction: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. IMPORTANT: External Pilot Construction: Zero minimum operating pressure differential when the gasket is in the external position and proper auxiliary air pressure is applied. See graph on page 36 for pilot line pressure vs. mainline pressure. ➄ At -59 F (-5 C), these constructions have a reduced life expectancy. Consult factory for details. IMPORTANT: Supervisory and leakage current above the drop out current of.89 ma for V DC will cause improper operation. Consult your local ASCO sales office for additional assistance. Single Solenoid SIL 3 Certified by Exida Dual Solenoid Body Material Pipe Orifice 3/, 5/ VALVES, with NBR and PUR Seals Brass 3/ Cv Flow Factor Operating Pressure Differential (psi) Air-Inert Gas Operating Pressure Differential (psi) Air-Inert Gas Min. Fluid Temp. F Catalogue Number Ref. Min. EF855H37 ➁ Fluid Temp. F Catalogue Number Brass 5/ EF855H39 ➁ EF855H3 ➁ / /.86 36L Stainless Steel 3/ EV855H33 ➂ EV855H3 ➂ 3 3 9 3 3 9 36L Stainless Steel 5/ EV855H3 ➂ EV855H3 ➂ Ref. EF855H38 ➁ 36L Stainless Steel 3/ EV8553H33 ➂ EV8553H3 ➂ / /3 3.7 36L Stainless Steel 5/ EV8553H3 ➂ EV8553H3 ➂ 3/, 5/, 5/3 VALVES, with NBR and PUR Seals, NAMUR Mount Brass 3/, 5/ EF855H33 ➁ 3 EF855H3 ➁ 3 / /.86 36L Stainless Steel 3/, 5/ 3 3 9 EV855H39 ➂ 3 3 9 EV855H3 ➂ 36L Stainless Steel 3/, 5/ / / 3.7 EV8553H39 ➂ EV8553H3 ➂ /8" NPT exhaust for /" aluminum and brass. ➁ Brass construction supplied standard with EF solenoid. ➂ Stainless steel construction supplied standard with EV solenoid. SIL 3 Certified by Exida, only valid when used as Normally Closed. Safety manual and FMEDA (Failure Modes Effects and Diagnostic Analysis) report available. 39

/ 3/ 5/ 5/3 Low Power Dimensions: inches (mm) Ref.,.5 [.3]. [9.56] M5 THREAD n3. MIN FULL THREAD DEPTH.5 `.5 MIN. TAP DRLL DEPTH PLACES.9 [.] / NPT.7 [.7] 3.7 [8.].9 [.] SPECIAL SERVICE VALVES.59 [.5].9 [3.]

/ 3/ 5/ 5/3 Low Power Dimensions: inches (mm) Series 855 8553 NPT / / L 5. (3) 6. (53) L 6.73 (7) 7.8 (98) H.38 ().77 () H. (8).58 () W.77 (5).85 (7) Ref. 3. [77].3 [5] SPECIAL SERVICE VALVES Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H H 3 /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand Series 855 8553 NPT / / L 5.63 () 7.6 (8) L 7. (83) 8.86 (5) H.38 ().77 () H. (8).58 () W.77 (5).85 (7) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref. 3. [77].3 [5] 5 3 Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand

/ 3/ 5/ 5/3 Low Power Dimensions: inches (mm) Series 855 (Brass) NPT / L.96 (6) L 6.9 (65) H.38 () H.57 () W.77 (5) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H H Ref. 3 3. [77].3 [5] /8 NPT 3 /8 NPT AUX. PRESSURE PORT / NPT L L 855 NAMUR Footprint SPECIAL SERVICE VALVES MH Momentary push in by hand.6 (3) MS Push and turn to lock by hand.95 ()

/ 3/ 5/ 5/3 Low Power Dimensions: inches (mm) SPECIAL SERVICE VALVES Series 855 (36L SS) 8553 NPT / / L 5. (3) 7.8 (8) L 6.73 (7) 8.85 (5) H.38 ().77 () H.57 ().8 (53) W.77 (5).87 (73) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. Add Suffix MO MI MH MS Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot Momentary push in by hand Push and turn to lock by hand 3. [77].3 [5] (855) / NPT (8553) / NPT H 5 3 H W /8 NPT AUX. PRESSURE PORT L L 8553 NAMUR Footprint 855 NAMUR Footprint Ref..77 (5).95 ().6 (3).57 () Ref. 5 3.6 [78].6 [5] S.95 [5] / NPT B R Ø8 [7] ( Places) C P H F K A N W M L Catalogue Number A B C F H K L M N P R S W in.8.68.8 5. 5..73.6.6.8.3.6 3.83 3.6 836H3, 3 mm 9 53 37 7 69 5 7 33 7 3 97 83 3

Intrinsically Safe and Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies /" to " NPT / 3/ / 5/ IS & NIFW Features Available in different coil terminations H Class coil construction Designed solely for installation in intrinsically safe or NIFW areas, with properly approved and sized limiting barriers Compatible with supervisory current applications Mountable in any position F M APPROVED Enclosure Ratings Catalogue Prefix Valve Construction Valve Parts in Contact with Fluids Body Aluminum Brass Stainless Steel Seals and Discs PUR, NBR, FKM as listed Sleeve 3 Stainless Steel Core and Plugnut 3F Stainless Steel Core Springs 3 Stainless Steel Pilot Seat Insert (Series 836 & 83 only) POM Rider Rings PTFE Spring Retainer POM Electrical Nominal voltage before the barrier VDC +/- %. Maximum Allowable Off State Leakage Current or Supervisory Current.6mA I loop I loop Where: R coil R coil R loop - Loop current in the circuit, which may be calculated as follows: = R barrier V supply V supply (R coil + R loop + R barrier ) - The resistance of the solenoid coil at T ambient in degrees C = 3 ohms x (T ambient + 3) 5 - Resistance of the lead wires - Internal resistance of the barrier - Supply voltage Enclosure Type Rating This current must always be greater than or equal to.3 amps for proper operation of the solenoid valve. Enclosure IP Rating Description 3, 3S IP55 IS /" NPT Conduit, X IP66 6, 6P IP67 JPIS Aluminum Junction Box, X IP66 with /" NPT Conduit 6, 6P IP67 JSIS 36L Stainless Steel Junction Box, X IP66 with /" NPT Conduit 6, 6P IP67 VT 5-Pin (Male M) NA IP ISSC DIN (Form A) NA IP Ordering Information Example: With Junction Box JPIS83B3 With 36L Stainless Steel Junction Box JSIS83B3 With Conduit IS83B3 With Quick Disconnect ISVT83B3 With DIN Connector ISSC83B3 Approvals FM and CSA approved for IS - Class I, Div. &, Groups A, B, C, and D; Class II, Groups E, F, and G. FM approved only for NIFW - Class I, Div. (US only) FM (US & Canada) approved under 337789 & 337789C CSA certified under File 3976, Class 38- (C of C 993) ATEX Approved for: II G Ex ia IIC T6 under FMATEX5X IECEx Approved for: Ex ia IIC T6 under IECExFMG.8X Meets applicable CE directives. Refer to Engineering Section for details. Entity Parameters Vmax = 3 VDC Ci = nf Imax = 5 ma Imax = 5 ma Pi =.5 W JPIS/JSIS Nominal Ambient Temp. Range Series Body Material Normal Temperature Range 8553 Stainless Steel 855 Brass - F to F (- C to 6 C) 836/5 Brass / Stainless Steel 855 Stainless Steel 83 - F to 9 F (- C to 65 C) Brass / Stainless Steel 837 836/5 836/6 Stainless Steel -59 F to 9 F (-5 C to 65 C) WBIS Nominal Ambient Temp. Range Series Body Material Normal Temperature Range 86 Brass / 83MF Stainless Steel - F to F (- C to 6 C) 83 Stainless Steel - F to F (- C to 6 C) SPECIAL SERVICE VALVES

/ 3/ / 5/ IS SPECIAL SERVICE VALVES Specifications / VALVES, NORMALLY CLOSED, with NBR Disc Operating Pressure Differential (psi) Pipe Orifice Air-Inert Gas Brass Body Stainless Steel Body Cv Flow Factor Min. Fluid and Ambient Temp. F Catalogue Number Ref. Catalogue Number Ref. / /6.8 5 WBIS86A3 WBIS86A386 A / 3/8 3. 5 5 - - WBIS83A3 3 3/ VALVES Cv Flow Factor Pressure to Cylinder to Cylinder Operating Pressure Differential (psi) Pipe Orifice Air-Inert Gas Brass Body Exhaust Min. Fluid and Ambient Temp. F Catalogue Number UNIVERSAL OPERATION (Pressure at any port) with NBR Disc Ref. Stainless Steel Body Catalogue Number / /6.6.8 3/5» 9 JPIS83B3 JPIS83B3 A NORMALLY CLOSED (Closed when de-energized) / 5/6.5.5 3 9 JPISX836B3MF/5 ➂ 5 JPISX836B38MF/5 ➂ 8 / 5/6.5.5 5 ➅ 9 - - JPISX836B38/5 ➇ 8 / 5/6.5.5 ➆ 9 - - JPISX836B38/6 ➇ 8 3/8 5/6.6.6 3 9 JPISX836B3MF/5 ➂ 5 JPISX836B38MF/5 ➂ 8 3/8 5/6.6.6 5 ➅ 9 - - JPISX836B38/5 ➇ 8 3/8 5/6.6.6 ➆ 9 - - JPISX836B38/6 ➇ 8 3/8 5/8 ➄ 3 9 JPISX836B33MF/5 ➂ 6 - - / 5/8 ➄ 3 9 JPISX836B3MF/5 ➂ 6 JPISX836B38MF/5 ➂ 9 UNIVERSAL OPERATION (Normally Closed or Normally Open) Quick Exhaust with NBR Diaphragm and NBR Disc / ➁.6.73 5 3 9 JPIS837B37 JPIS837B38 / VALVES, Brass Body with NBR Disc Single Solenoid Ref. Dual Solenoid Ref. / /.8 3 5 WBIS83A37MF ➂ 3 WBIS83A3MF ➂ 6 3/8 3/8.. 5 WBIS83A37MF ➂ WBIS83A38MF ➂ 7 / 3/8.. 5 WBIS83A37MF ➂ WBIS83A38MF ➂ 7 3/ 3/ 5. 5.6 5 WBIS83A376MF ➂ 5 - - 3/ 5. 5.6 5 WBIS83A378MF ➂ 5 - - There are two exhaust flows in the exhaust mode (pilot and main). The pilot exhaust must be connected to the main exhaust when the air or inert gas cannot be exhausted to the atmosphere. ➁ For Quick Exhaust valves, pressure port is /6", exhaust port is /". ➂ IMPORTANT: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. At temperatures below 3 F: 5 psi minimum mainline operating pressure differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph with dimensional drawings for auxiliary pressure vs. mainline pressure. Minimum 5 psi operating pressure differential when selection gasket is in the internal position. Ref. ➄ At temperatures below 3 F: 5 psi minimum mainline operating differential when valve selection gasket is in external position and proper auxiliary air pressure is applied. See graph with dimensional drawings for auxiliary pressure vs. mainline pressure. Minimum 5 psi operating pressure differential when selection gasket is in the internal position. ➅ IMPORTANT: Internal Pilot Construction: A minimum operating pressure differential must be maintained between the pressure and exhaust ports. Supply and exhaust piping must be full area, unrestricted. ASCO flow controls and other similar components must be installed in the cylinder lines only. ➆ IMPORTANT: External Pilot Construction: Zero minimum operating pressure differential when the gasket is in the external position and proper auxiliary air pressure is applied. See graph on page 8 for pilot line pressure vs. mainline pressure. ➇ At -59 F (-5 C), these constructions have a reduced life expectancy. Consult factory for details.» Normally closed = 3 psi. Normally open = 5 psi. 5

/ 3/ / 5/ IS Specifications Body Material Pipe Orifice Cv Flow Factor Single Solenoid Operating Pressure Operating Pressure Differential (psi) Differential (psi) Air-Inert Gas Fluid Catalogue Air-Inert Gas Min. Temp. F Number Ref. Min. Dual Solenoid Fluid Temp. F Catalogue Number 3/, 5/ VALVES, with NBR and PUR Seals Brass 3/ JPIS855B37 9 JPIS855B38 9 Brass 5/ JPIS855B39 JPIS855B3 / /.86 3 3 9 3 3 9 36L Stainless Steel 3/ JPIS855B33 9 JPIS855B3 9 36L Stainless Steel 5/ JPIS855B3 JPIS855B3 Ref. Body Material Pipe Orifice Cv Flow Factor Single Solenoid Operating Pressure Operating Pressure Differential (psi) Differential (psi) Air-Inert Gas Fluid Catalogue Air-Inert Gas Min. Temp. F Number Ref. Min. Dual Solenoid Fluid Temp. F Catalogue Number 3/, 5/ VALVES, with NBR and PUR Seals, NAMUR Mount Brass 3/, 5/ JPIS855B33 JPIS855B3 / /.86 3 3 9 3 3 9 36L Stainless Steel 3/, 5/ JPIS855B39 JPIS855B3 /8" NPT exhaust for /" aluminum and brass. Ref. SPECIAL SERVICE VALVES Dimensions: inches (mm) Ref., A 6

/ 3/ / 5/ IS Dimensions: inches (mm) Ref. 3 Ref., A SPECIAL SERVICE VALVES Ref. 5 7

/ 3/ / 5/ IS Dimensions: inches (mm) Ref. 6 Ref. 8 SPECIAL SERVICE VALVES Ref. 9 Ref. Refer to note ➆. For all 836. MAINLINE PRESSURE vs. PILOT LINE PRESSURE WHEN SELECTION GASKET IS IN EXTERNAL POSITION PILOT LINE PRESSURE (psi) 6 9 75 6 5 3 5 5 3 5 6 75 9 5 35 5 MAINLINE PRESSURE (psi) 8

/ 3/ / 5/ IS Dimensions: inches (mm) Ref. SPECIAL SERVICE VALVES Ref. 3-7 3-5 6-7 All Catalogue No. ØC E F G H J K L M N P W X Y Z WBIS83A37 ins..8.56..88 5..3.33 3.3.8.7.6.75..56.8 mm 7. 6 8 3 6 59 8 53 8 6 36 WBIS83A38, 38 ins..3.77 3..6 5.7.5.77 3.8.6.83.6 6.6.86.9.8 mm 8.6 79 67 5 38 7 8 5 7 5 7 8 WBIS83A37, 37 ins..3.77 3..6 5..5. 3.8.6.83 3.98 6.6.86.9.8 mm 8.6 79 67 38 5 8 5 5 7 8 WBIS83A3 ins..8.56..88 5..3.7 3.3.8.7.6.75..56.8 mm 7. 6 8 3 6 7 8 53 8 6 36 WBIS83A376, 378 ins..3.37 3.8 3.88 5.9.9.5.56.86.55.35 8.5..63.6 mm 8.6 35 97 99 5 53 6 6 73 39 5 67 3 IMPORTANT: Valves can be mounted in any position. Exhaust Pipe 3/8" /" /" 3/8" " 9

/ 3/ / 5/ IS Dimensions: inches (mm) Series 855 8553 NPT / / L 5. (3) 6. (53) L 6.73 (7) 7.8 (98) H.38 ().77 () H. (8).58 () W.77 (5).85 (7) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref. 9.5 (5) 3.6 (8) / NPT 3.96 (8) 3. (77) Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H /8 NPT AUX. PRESSURE PORT L L SPECIAL SERVICE VALVES MH Momentary push in by hand MS Push and turn to lock by hand Series 855 8553 NPT / / L 5.63 () 7.6 (8) L 7. (83) 8.86 (5) H.38 ().77 () H. (8).58 () W.77 (5).85 (7) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref..5 (5) 3.6 (8) / NPT 5 3.96 (8) 3. (77) Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W H /8 NPT AUX. PRESSURE PORT L L MH Momentary push in by hand MS Push and turn to lock by hand 5

/ 3/ / 5/ IS Dimensions: inches (mm) Series 855 (Aluminum, Brass) NPT / L.96 (6) L 6.9 (65) H.38 () H.57 () W.77 (5) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref..5 (5) 3.6 (8) / NPT.96 (8) 3. (77) SPECIAL SERVICE VALVES Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot W 3 H /8 NPT AUX. PRESSURE PORT L L 855 NAMUR Footprint MH Momentary push in by hand.6 (3) MS Push and turn to lock by hand.95 () Series 855 (36L SS) 855 (5/3) 8553 NPT / / / L 5. (3) - 7.8 (8) L 6.73 (7) 7. (89) 8.85 (5) H.38 ().38 ().77 () H.57 ().57 ().8 (53) W.77 (5).77 (5).87 (73) Manual override option MH adds.5" (6.), MS option adds.68" (.9) to each solenoid endcap. H Ref..5 (5) 3.6 (8) / NPT 5 3.96 (8) 3. (77) Add Suffix MO MI Optional Manual Operators Description Push and turn to lock with flat head screwdriver slot Momentary push in with flat head screwdriver slot H W /8 NPT AUX. PRESSURE PORT L 8553 NAMUR Footprint L 855 NAMUR Footprint MH MS Momentary push in by hand Push and turn to lock by hand.77 (5).95 ().6 (3).57 () 5

No Voltage Release Air and Inert Gas Intrinsically Safe Manual Reset Valves Stainless Steel Bodies /" to /" NPT 3/ ISMR Features Intrinsically safe solenoid. When energized, holds the manual reset mechanism in the latched position Normally closed, normally open, or universal constructions Valve operates when the solenoid has been energized and the lever latched while holding in the yellow button Valve trips when power is interrupted. Valve can be manually cycled, but must be manually reset for automatic operation Designed solely for installation in intrinsically safe areas, with properly approved and sized current and voltage-limiting safety barriers Acceptable for use in hazardous locations as classified by the National Electrical Code: Classes I, II, and III, Division, including Groups A through G F M APPROVED SPECIAL SERVICE VALVES Construction Valve Parts in Contact with Fluids Body Seals and Disc Core and Plugnut Core Springs Core Tube Pilot Seat Cartridge Rider Rings Spring Retainer Stainless Steel NBR 3F Stainless Steel 3 Stainless Steel 35 Stainless Steel POM (Series WPIS838C) PTFE POM Electrical Standard Voltages: volts DC Coil: Continuous duty moulded Class A. Minimum Operating Current:. amps Parameters Groups A-D Groups C-D Entity V max - 8 VDC V max - 3 VDC I max - 9 ma I max - 5 ma Capacitance = Capacitance = Inductance = Inductance = IMPORTANT: Electrical parameters are unique to the manual reset line and will differ from other Intrinsically Safe valve s electrical data. Nominal Ambient Temp. Ranges - F to F (- C to 93 C). Approvals FM approved under J. I. 3WA7.AX (36). CSA certified under File LR-3976. FM Nonincendive approved for Class, Division. Enclosure Standard: RedHat Type, Watertight Splice Box enclosure. Optional: No standard options are available. Consult local sales office for your needs. 5

3/ ISMR Specifications Pipe Orifice Cv Flow Factor 3/ UNIVERSAL OPERATION, Stainless Steel Body with NBR Discs Min. Operating Pressure Differential (psi) Air-Inert Gas Fluid and Ambient Temp. F Catalogue Number / /8. 5 8 WPIS838AMF 3/ UNIVERSAL OPERATION, Stainless Steel Body with Stainless Steel Seats and Discs / 5/6.75 5 WPIS8387MF 3 For dimensions, consult factory. Ref. SPECIAL SERVICE VALVES 53

Tamper Proof Manual Reset Valves Stainless Steel Bodies /", 3/8" and /" NPT 3/ ISMR Features 3 Way constructions -59 F (-5 C) constructions available Low Power or IS with Limit Switch 36SS (CF-8M) Stainless Steel externals with NBR elastomers Wide range of Cv flow rates.5,.8 and Solenoid operator CSA certified, UL Listed for Hazardous Locations Used by numerous refineries as emergency shut down SPECIAL SERVICE VALVES Model shown HV837- VDC Ambient rating -59 F (-5 C) 3 Way Tamper Proof Manual Reset Valve General Description This unique tamper proof manual reset valve has the special ability that once tripped the latching handle, if moved will not change the position of the valve. Conversely, if the handle is held in the up position and the control room de-energizes the solenoid, the valve will go to the shut-off position. It will also automatically trip to the closed position if the auxiliary instrument air pressure drops below 5 psi. 5

3/ 5/ NF ATEX Solenoid Valves Brass or Stainless Steel Bodies /" NPT Features ATEX 9/9/EC directive approved Can be used in Zone and Zone hazardous areas Direct acting and indirect acting valves available Available voltages of volts DC and 3 volts, 5 Hz AC All constructions have functional safety data per IEC 658 available SPECIAL SERVICE VALVES Construction Valve Parts in Contact with Fluid Valve Series 837 855 Body Br or 36 SS 36 SS Core and Plugnut 3F SS Core Tube 33 SS Disc and Seals VMQ PUR & VMQ Rider Ring PTFE Springs 33 SS Series 837 Body Material All Materials 855 SS ATEX Safety Code II G/D Eex d IIC Voltage Min. Ambient Temp. F ( C) T Amb. T F ( C) T Cable T Amb. T5 F ( C) T Cable T Amb. T6 F ( C) T Cable AC () 58 (7) - (-) - DC () 58 (7) AC (6) 9 (9) () 58 (7) 77 (5) 58 (7) - (-) DC - 9 (9) (6) 76 (8) () 58 (7) Solenoid Enclosures Standard: Electrical Enclosure Protection (EN659): Aluminum IP-67 Approvals Directive ATEX 9/9/EC II G/D Eex d IIC T6. T IP67 EC type examination certificate no. LCIE ATEX 68 X 55

ATEX Solenoid Valves Brass or Stainless Steel Bodies /" NPT 3/ 5/ NF Specifications 3/ VALVES, UNIVERSAL (Normally Closed or Normally Open), Direct Acting Pipe (ins) Orifice (ins) Cv Flow Factor Operating Pressure Differential (psi) AC Fluid Temp. F Ports - Ports -3 Min. Air-Inert Gas Water Light Oil @ 3 SSU Air-Inert Gas Water Light Oil @ 3 SSU AC DC ➁ Catalogue Number Body Material AC DC / /.9.56 5 5 5 5 5 5 NF837B BR NF837B 36 SS. 3/ VALVES, NORMALLY CLOSED (Closed when de-energized), Indirect Acting Pipe (ins) Orifice (ins) Cv Flow Factor DC Wattage Operating Pressure Differential (psi) Wattage Min. Air-Inert Gas Fluid Temp. F ➁ Catalogue Number Body Material AC DC / /.86 3 5 NF855A3 36 SS.5. 5/ VALVES, Indirect Acting Pipe (ins) Orifice (ins) Cv Flow Factor Operating Pressure Differential (psi) Wattage Min. Air-Inert Gas Fluid Temp. F ➁ Catalogue Number Body Material AC DC / /.86 3 5 NF855A 36 SS.5. 3/, 5/ NAMUR MOUNT VALVES, Indirect Acting Pipe (ins) Orifice (ins) Cv Flow Factor Operating Pressure Differential (psi) Wattage Min. Air-Inert Gas Fluid Temp. F ➁ Catalogue Number Body Material AC DC / /.86 3 5 NF855A9 36 SS.5. SPECIAL SERVICE VALVES Zero minimum when end cap gasket is in external position and proper auxiliary air pressure is applied. Minimum 3 psi Operating Pressure Differential when end cap gasket is in the external position. See I&M sheet for details. ➁ For dimensions, consult factory. 56

Accessories Lightweight, High Flow Air Only Quick Exhaust Shuttle Valve Stainless Steel Bodies /" NPT Features Compact, 3-ported valves have oversized orifice for quick exhaust of cylinders, brakes, actuators, clutches, etc. Allow use of smaller pipe lines and control components When used as a shuttle valve, high pressure from the two inlets exits through the common outlet Mountable in any position Construction Valve Parts in Contact with Fluids Body and Bonnet 36 Stainless Steel ACCESSORIES Seat Specifications TEEE Nominal Ambient Temp. Ranges - F to 5 F (- C to 5 C) Pipe Pressure to Cylinder Cv Flow Factor Cylinder to Exhaust Opening Pressure (psi) Maximum Operating Pressure Differential (psi) Air Temp. F Quick Exhaust/ Shuttle Valve Body Material Catalogue Number /.8. 5 5 5 V3 5 S.S 3 Ref. Dimensions inches (mm) Ref. 3 Flow Diagrams Inlet Pressure Inlet Pressure Common Outlet Common Outlet Inlet Pressure Inlet Pressure Inlet Pressure Cylinder Cylinder Exhaust 57

Optional Explosionproof Junction Box for Hazardous Locations Features Features Junction Box Enclosures for the wiring of ASCO solenoids are Raintight Type 3 and 3S, Watertight Type and X, Submersible Type 6 and 6P, Explosionproof Type 7, Class I, Groups B, C, and D Dust-Ignition proof Type 9, Class II, Div., Groups E, F and G, Nonincendive Class I, Div. (. watts only) Approvals: UL, CSA Electrostatic powder paint, stainless steel screws, and moulded epoxy coils provide excellent protection in corrosion environments Factory pre-wired and assembled to any explosionproof ASCO RedHat II solenoid valve Reduces installation costs by eliminating the need to use a separate explosionproof splice box to terminate the solenoid valve s wiring % ^ Stainless Steel Captive Screws Materials of Construction Housing and Cover Epoxy painted die-cast aluminum Gasket NBR Cover Screws Stainless Steel Coil Epoxy Moulded Ground Screws Steel Terminal Block Plastic Lock Nut Zinc Captive Gasket Electrostatic Powder Painted Aluminum Housing & Cover OPTIONAL FEATURES Electrical Standard Voltages AC:,,, 8 volts, 6 Hz or (, volts, 5 Hz) pt. Terminal Strip Ground Screws Conduit/Cable Connection DC: 6,,,, Note: Valves with JBEF housing maintain wattage and current ratings as shown on individual catalogue sheets. Conduit s Approvals Agency UL CSA /" NPT JBEF Prefix (Standard) 3/" NPT JCEF Prefix (Optional) Explosionproof Junction Box Agency Approvals Temperature Range Gas Groups JBEF (/ ) JCEF (3/ ) Class I, Groups B, C, & D Class I, Group B Class I, Groups C & D - F to 75 F (- C to 8 C) -3 F to 75 F (-5 C to 8 C) - F to 75 F (- C to 8 C) Dust Groups Class II, Groups E, F, & G Ordering Information Add prefix corresponding to specific conduit size required to any RedHat II valve catalogue numbers & specify the voltage. Example: JBEF83H3, VDC. Dimensions Consult factory. 58

Canada Main Office, Manufacturing, Marketing 7 Airport Road, P.O. Box 6 Brantford ON N3T 5M8 Phone: (59) 758-7 Fax: (59) 758-55 Website: www.ascovalve.ca USA Hanover Road Florham Park, NJ 793 Phone: (973) 966- Fax: (973) 966-8 Website: www.ascovalve.com For Western Provinces Phone: -866-696-6 District Sales Offices Canada: Quebec, Ottawa Valley, Atlantic Provinces 3 Douglas. - B. - Floreani St. St. Laurent QC HS Y7 Phone: (5) 33-6 Fax: (5) 33-973 For Atlantic Provinces Phone: (9) 89-5 Fax: (9) 89-7 Germany Tel (9)-737-996 Australia Tel (6) -9-5-777 United Kingdom Tel () 695-736 Brazil Tel (55) -8-7 China Tel (85) -33-858 Mexico Tel (5) 55-36- Singapore Tel (65) 6556- France Tel (33) -7--3- Japan Tel (8) 798-65-636 CAT # LA.R3 5/3