DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-230 Industrial Control Damper

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

L O U V E R S & D A M P E R S

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

When Time is Everything... We Manufacture in Days - Not Weeks!

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

VCD-23. Flange Options. Size Limitations

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Motorized Fire Dampers

AMD-33 Air Measuring Station with VCD-33 Control Damper

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

A Complete Line of Quality Products for Marine Applications

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

VCD-23. Low Leakage CONTROL DAMPER

Model VCD-43 Extruded Airfoil Blade Control Damper

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

ID-141x 12-Gauge Hat Channel Industrial Damper

MOTORIZED VOLUME DAMPER

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

VCD-23 Low Leakage CONTROL DAMPER

VOLUME CONTROL DAMPERS

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

SECTION CONTROL DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Thermal Isolation. Break

AIR CONDITIONING PRODUCTS COMPANY

SD-1250 and SD-1600 Series Smoke Dampers

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

MODEL OAL. Water Penetration. Water Penetration. Free Area OAL PERFORMANCE REGISTERS GRILLES &

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model VCD-20 3V CONTROL DAMPER

PC-125x Counter-Balanced Backdraft Damper

CONTROL DAMPERS GENERAL PRODUCT OVERVIEW MODELS 1010 & 1020 LOW LEAKAGE CONTROL DAMPER VEE GROOVE BLADE MODELS 1012 & 1022 STANDARD CONTROL DAMPER

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

BD-1600 Balancing/Zone Control Damper

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Series HCD Airfoil Control Damper

FSD60/MFSD60 Multi-blade Fire Damper

Sand Trap Louvers OSTL 300 SERIES. Sand Trap Louvers

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

CFSD Series. Product Description

GRAVITY VENTILATORS SIZING

Model FSD-331 Combination Fire Smoke Dampers

RETROFIT TERMINAL UNITS

AIRODYNE CATALOGUE VOLUME CONTROL TAMPERS CONSTRUCTION / MATERIALS

SECTION DUCTWORK ACCESSORIES

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Introduction to Johnson Controls Dampers

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Air Louvers OFAL 300 SERIES

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Complete HVAC Capability

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

HVAC Control & Balancing Dampers

Filtered Kitchen Supply Packaged Ventilator

SMOKE DAMPER - CLASS F MODEL BMSD

Climas y Proyectos Leyco, S.A. de C.V.

DAMPERS WE CONTROL AIR

Centrifugal Filtered Supply Roof Blowers

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

SECTION AXIAL HVAC FANS

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION DUCTWORK ACCESSORIES

AD-1250 Airflow Measuring Station

COMBINATION FIRE/SMOKE DAMPER - CLASS F MODEL BMFSD (3 HR) / MODEL BEMFSD (1½ HR)

MULTI-BLADE FIRE DAMPERS

VANEAXIAL & TUBEAXIAL FANS

Axial Propeller Panel Fans, PAF-Series

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Marine Fire and Gas Dampers

Transcription:

IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES

ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products for over 5 years. We have grown with exposure to state-of-the-art technology and the most advanced methods of manufacturing. This is reflected in Arrow United s quality products. This publication describes various types of our standard industrial products designed to meet special conditions of temperature, pressure, velocity, and system environment. Arrow United is willing to work closely with engineers for any specific applications. Our staff is ready to assist you in meeting your requirements. Heavy Duty Backdraft Dampers These heavy duty dampers are designed to permit air flow in one direction at a specified pressure and to prevent a reverse air flow. Field-adjustable counterweights are available for pre-determined opening pressures. Model 400 - Tear Drop Design. To wg Static Pressure at 6000 fpm. 4 gauge galvanized steel when neither width nor height exceed. 0 gauge galvanized steel when either width or height exceeds. 6 gauge galvanized steel. Bronze Oilite. Axle: 4 diameter steel. Single for panels under 20 wide. Double for panels over 20 wide. Seals: Polyurethane. Special seals on blades and jambs may be added for low leakage. Counterweights: Adjustable. To assist or resist opening. (Optional) Maximum Temp.: 250 F. Model 400 Model 900 - Tear-Drop Design For Extra Heavy-Duty Applications. 2 x x 2-2 gauge galvanized steel channel. 6 wide, extruded aluminum Ball bearings pressed into frame. Axle: 4 diameter steel, with positively locked to blade. Plated steel. Seals: Silicone seals on blade ends. None at jambs. Counterweights: Adjustable, to assist or resist opening. Model 900 400 900 PERFORMANCE DATA (dampers with assist counterweights) WITHOUT DUCT WITH DUCT START OPEN FULL OPEN START OPEN FULL OPEN 00 fpm 00 fpm.20 wg 5000 fpm 500 fpm 5. wg 2.4 wg 0 fpm 50 fpm. wg 5000 fpm 500 fpm.5 wg.40 wg 2

Heavy Duty Dampers Model 00 : To 2 wg Static Pressure Reduction in blade lengths increases static pressure limits. SPECIFICATIONS 6 gauge galvanized steel, 4 deep Hat Shaped frame. Blade: 6 gauge galvanized steel airfoil - wide max. Shaft: 2 diameter plated steel shaft full length. Stainless steel flanged sleeve, press fit into frame. Face mounted, Located in the airstream. Formed bracket of thick steel. Trunnion is a machined pivot of plated steel with a 5 6 diameter rod. Operator: 6 Extended shaft. Finish: Mill. Max. Temperature: 250 F. For temperature above 250 F, consult factory. Max. Panel Size: x 72 - Hat-Shaped frame. x 96 - Channel frame. Min. Panel Size: 2 x Single blade. 2 x 2 Opposed. Model 545: To wg Static Pressure Fan Discharge Damper For Clean Air Applications only. wide,.00 extruded aluminum Arrow - Foil blade. 2 x x 2 heavy duty, steel formed channel frame. Maximum temperature to 400 F. Model 00 Model 42: To 6 wg Static Pressure at 2500 fpm Model 422: To wg Static Pressure at 2500 fpm Model 42: To wg Static Pressure at 2500 fpm Velocities above 2500 to 4000 fpm (max.) require a double set of face linkage. 2 x x 2. Heavy duty galvanized, formed channel frame. Maximum 9 4 ; minimum 6 4. Heavy duty galvanized, pressure formed single thickness. Bronze oilite flanged sleeve pressed into frame. Shafts: Corrosion - resistant. Plated cold finished steel 2 or 4 diameter. Heavy duty, steel brackets; machined pivots of plated steel. Operator: Manual or motor. Max. Temperature: 250 F 00 545 42,422,42 DAMPER WIDTH SELECTED PERFORMANCE DATA 2 4,000 FPM 4,000 FPM 2,500 FPM FULL OPEN.50 wg.42 wg.2 wg LEAKAGE WITH SEALS CFM / SQ. FT. 25.2 5.0 0. Dampers may be constructed of other than standard materials when required to meet special conditions. For options and detailed specifications, see individual data sheets. Reducing blade length will increase static pressure limits. Model 545 Model 42

Heavy Duty Dampers Model 50: To 2 wg Static Pressure Model 5: To 20 wg Static Pressure 2 x x 2. Heavy duty galvanized, formed channel frame. Maximum 9 4 ; minimum 6. Heavy duty galvanized, air- foil. Stainless steel flanged sleeve, bolted to Shafts: frame. Corrosion - resistant. Plated cold finished steel. Located in jamb. 2 diameter inter - connecting rod with trunnion pivot fastener. Operator: Manual or motor. Max. Temperature: 450 F. (For temperatures above 450 F, consult factory.) Model 50 / 5 Model 540: To 5 wg Static Pressure Temperatures to 00 F. 2 x x 2. Heavy duty steel formed channel frame. Maximum 9 4 ; minimum 6. Heavy duty steel, air - foil. Ball bearings mounted on stand-off bracket. Shafts: Cold finished steel, diameter. Located in jamb. 2 diameter interconnecting rod with trunnion pivot fastener. Operator: Manual or motor. Max. Temperature: 00 F. (For temperatures above 00 F, consult factory.) Model 540 50 5 PERFORMANCE DATA ( x DAMPER) DAMPER WIDTH 4 2 5 5 20 FULL OPEN Reducing blade length will increase static pressure limits. LEAKAGE WITH SEALS - CFM PER SQ. FT. 5.5 2.6 9. 2.0 4. 0.6 5.4. 2.7 4

Heavy Duty Round Dampers Fabricated steel channel. Channel depth equal to blade diameter of or less. Blade: Single thickness with reinforcing gussets welded to blade parallel to air flow as required. Shaft: Plated steel continuous length welded to blade. Bearing : Sintered stainless steel flanged sleeve pressed in the frame. Stop: 4 x 4 metal bar for sizes to 2 diameter. 4 x 2 metal bar beyond 2 diameter to shall be welded to interior perimeter of frame. Operator: Extended shaft 6 long beyond frame flanges. Finish : Mill / galvanized / zinc rich touch up. Minimum: 6 diameter. Maximum: diameter. Max. Temperature: 250 F. (Consult factory for higher temperature requirements.) Model 50-R / 5-R Model 50 - R - Max S.P 2 wg INSIDE FRAME DIAMETER ABOVE THROUGH DEPTH FLANGE x GA. to 6 dia. x GA. to dia. 6 2 4 x GA. to 9 dia. x GA. to dia. 2 x GA. to 2 dia. 2 6 2 6 2 6 2 x 2 x 6 to dia. 2 x 2 x 6 to 26 dia. 2 x 2 x 6 above 26 dia. to dia. INSIDE FRAME DIAMETER ABOVE THROUGH DEPTH FLANGE x GA. to 6 dia. x to dia. 4 x to 9 dia. x to dia. 2 x to 2 dia. 2 x 2 x 6 to dia. 2 x 2 x 6 to dia. 2 x 2 x 6 above 26 dia.to dia. BLADE THICKNESS 2 GA. to 6 dia. w/ 2 gussets to dia. Model 5 - R - Max. S.P 20 wg BLADE THICKNESS 7 GA. 7 GA. w/ 2 gussets 7 GA. w/ gussets SHAFT DIA. 2 4 SHAFT DIA. 2 4 PERFORMANCE DATA ( DIA. DAMPER SIZE) DAMPERS WITH LOW LEAKAGE 50-R 5-R DAMPER WIDTH Model 5-R Low Leakage Configuration PRES. 4 5 5 PRES. FULL OPEN. wg. wg. wg. wg LEAKAGE CFM / SQ.0005...0005.20.27.4 Construction may be with other than standard materials when required to meet special conditions as temperature, pressure, velocity, system environment or other specifications. 5

Acoustical Louvers Model FS - 40 (LF / HF) Formed Steel 45 STATIONARY 4 deep Model FL - 700 Formed Steel Louver Combination adjustable and stationary 7 deep - insulated / acoustical blade. SPECIFICATIONS 6 GA. galvanized steel - 4 deep Blade: GA. galvanized steel on exterior with 22 GA. galvanized perforated steel on interior surface. Approximate blade centers 7 2. Insulation: Arrow sound insulation. Screen: 2 SQ. mesh, 9 GA. galvanized (.04 ), when indicated. Construction: Riveted and or welded, with head, sill, and blades contained within jambs. Finish: Mill. Min. Panel Size: 2 x. Max. Single Panel Size: x 96. The Arrow Model FS - 40 acoustical louver low frequency and high frequency sound performance data is presented in two separate tables. Review the appropriate table and select the attenuation value for the design noise criteria corrective action required. Model FS - 40 - LF (Low Frequency) OCTIVE 2 4 5 6 BAND FREQUENCY 6 25 250 500 000 2000 FREE FIELD OF NOISE REDUCTION (db) 2 4 2 2 9 Model FS - 40 - HF (High Frequency) OCTIVE 2 4 5 BAND FREQUENCY FREE FIELD OF NOISE REDUCTION (db) 6 25 7 250 9 500 0 000 4 6 2000 6 7 4000 000 5 7 4000 000 Operators A variety of operators to meet the requirements of heavy duty applications is readily available. They include manual, electric, pneumatic and hydraulic operators. Functions can be as simple as two - position, spring return or very complex, modulating fail safe operation. Accessories such as auxiliary switches, maintenance lock outs or remote position indication can be incorporated. Users of industrial Dampers have learned to rely on our experience in providing actuators mounted and linked to dampers. We will recommend to you a damper - actuator system coordinated to survive the end - use environment. Arrow United makes an extensive line of Commercial Dampers which can be used in light industrial applications. 6 SPECIFICATIONS 6 GA. galvanized steel. Stationary blade is GA. galvanized steel. Adjustable blade is GA. galvanized steel double thickness, thick with lb. density mineral wool insulation sandwiched between metal skins separated by a thermal break, mechanically fastened together. Face of Louver: Full head and sill with blade and jambs contained within. Brackets are 2 GA. zinc plated steel, pivots are.50 dia. machined steel, zinc plated and chromate treated. Pivots rotate in a celcon bearing. A.2 dia. aluminum linkage rod is locked to the pivot by a 4-20 set screw with an epoxy locking patch. Seals: Neoprene adhesive applied to blade edges and jambs. Shafts: 2 diameter plated steel stub. 2 bore oilite bronze flanged sleeve, press fit into frame. Screens: Secured to the exterior. Bird Screens: 2 SQ. mesh 9 GA. galvanized steel (.04 ) 2 flattened aluminum (.05 ). Insect Screen: 6 mesh (.0 dia.). Finish: Mill. Louver Sizes: 2 x 4 Minimum, x 96 Maximum. Louvers shall have (45%), 7.26 SQ. FT free area for a size x with a water penetration at.0 ounce per SQ. FT of free area at a free area velocity of 25 fpm (599 cfm), with. water gauge pressure drop for intake. Acoustical Valves For Noise Reduction Shall Not Be Less Than: 6 9 25 250 7 500 000 0 2000 5 4000 5 000 6 And provide a U.26 BTU per hour per SQ. foot per degree F thermal characteristics. In the interest of product improvement Arrow reserves the right to make changes without notice. Arrow United products are marketed through an extensive network of Manufacturer s Representatives. Call our office for the one nearest you. ARROW UNITED INDUSTRIES 4 Riverside Drive Wyalusing, PA 5 (570) 746- FAX: (570) 746-926 Check our website for other products. arrowunited.com