NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

Similar documents
User s Manual. Automatic Switch-Mode Battery Charger

Service and Parts Manual. NO LONGER IN PRODUCTION Some service parts may not be available for this product. Otolaryngology Chair.

INSTALLATION & OPERATION MANUAL

for Reproduction Not Brighter. Warmer. Safer. Portable Industrial Heaters Portable Light Towers Portable Light Stands Solar Flashing Arrow Boards

3 Phase Smart Controller

ATLAS Wheel Balancer Electrical Flow Chart

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Controlled Ferroresonant Ballast (CFB) Generation #3. Manual

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

OnCommand Troubleshooting Guide Hayward Industries

Troubleshooting Guide: 355 Lights (24V)

Troubleshooting Guide: 355 Lights (12V)

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

RigMaster Power Service and Repair Manual Document # S901009

XENON POWER SUPPLY 4000 Watt Gladiator IV

PAGE Both power cords must be connected & powered to operate the E-TES 120.

High Frequency SineWave Guardian TM

Troubleshooting Guide

MAXI-LITE V-SERIES ML 7.5/ML 8 OPERATOR S MANUAL ALLMAND BROS. INC P.O. BOX 888 HOLDREGE, NE 68949

Some service parts may not be available for this product!

5.5 FT PRE-LIT SERBIAN SPRUCE TREE

PAGE Both power cords must be connected & powered to operate the E-TES SD 120 volt unit.


Matala. VersiFlow Series. Instruction and Maintenance Manual

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

INSTALLATION GUIDE AND USER MANUAL

for Reproduction Not Brighter. Warmer. Safer. Portable Industrial Heaters Portable Light Towers Portable Light Stands Solar Flashing Arrow Boards

Arnberg Industries & It s Partners are not responsible for any damage or injury caused by correct or incorrect installation of this transfer switch.

EMERY SKY SUSPENDED LED LUMINAIRE

Troubleshooting Guide

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

UNPACKING SAFETY GUIDELINES GENERAL SAFETY INFORMATION. Operating Instructions & Maintenance Manual

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

BL7000 SYSTEM OPERATING MANUAL

GRD502-B Flow Chart 02/05/09

The Power of Reliability INSTRUCTION MANUAL

DIGITAL GIANT POPCORN MACHINE SERVICE MANUAL

SUBMERSIBLE PUMP HSE RANGE

GeyserMax-Flow Series

Troubleshooting Guide

Troubleshooting Guide: 255 LED Light

ASSEMBLY INSTRUCTIONS

E.S.P. Embedded Sensing Probes for Motor Brushes

ASSEMBLY INSTRUCTIONS PRODUCT CODE: CAUTION: Carefully Read Instructions and Procedures for Safe Operation. 7' Diamond Peak LED Tree

Car Battery Charger Instructions for Use

FACT SHEET Standard: Electrical Safety

Operating Instructions & Parts Manual

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Operating Instructions

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

LOW-VOLTAGE TRANSFORMER INSTALLATION GUIDE. Models: VTR-100SL-SS, VTR-150SL-SS, & VTR-300SL-SS

SUBMERSIBLE PUMP HSE RANGE

1) READ THE M500 INSTRUCTIONS CAREFULLY TO GET A FULL UNDERSTANDING OF THE M500 AND HOW IT OPERATES.

COLDWATER LAKE FACILITIES DUPLEX PUMP STATION

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

MODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

03561 SPEED BOOSTER INSTRUCTION MANUAL. for the Ultra Tugger

INDEX Section Page Number Remarks

# : SMU - Revised DTC P0201-P (Sep 16, 2002)

User Manual ELECTRICAL VEHICLE CHARGING STATION LEVEL 2 EVC30T/EVC30T-IN

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Electric Vehicle Charging Station

Troubleshooting 3Z8 038 Rev B

Elegance Electrician s Installation Guide

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

CONTROL FEATURES AVAILABLE OPTIONS

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

Installation/Operating Instructions

This chapter contains information on DC Generation, External Power, and Electrical Load Distribution.

ATTACH YOUR RECEIPT HERE ITEM # FT. PRE-LIT DOUGLAS FIR TREE. MODEL #DF-75C85 Español p. 8

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

The Da-Lite Difference.

XENON POWER SUPPLY Watt

Reproduction. Not for ADVANCE PRODUCT SERVICE INFORMATION INFORMATION BULLETIN NO: 36 DATE: 11/27/02 SUBJECT: POWERLINK SYSTEM

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Instruction Manual. H.I.D Digital Ballasts 400W 600W 1000W. All our ballasts are compatible with Safe Grow Hydroponic Smart System.

INSTALLATION GUIDE AND USER MANUAL

QPET, QPETXU Battery Chargers

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

13IN. WAREHOUSE BARN RETROFIT LIGHT OWNER S MANUAL

Service Bulletin Trucks

Checker Unload Checkstand Installation Instructions

UNIT 3: GENErAL ELECTriCAL SySTEM DiAGNOSiS

ROYCE AIR COMPRESSOR 415VOLT/3 PHASE OPERATIONS MANUAL

Safety Working with LV Drives

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

EMIU 720W Mini Inverter

Transcription:

NIGHT-LITE PRO II Electrical System Troubleshooting Guide and Procedures Allmand Bros. Inc. PO Box 888 1502 W. 4 th Ave. Holdrege NE 68949 USA 308-995-4495 Phone 800-562-1373 Toll-Free www.allmand.com

Allmand Night-Lite PRO II Light Tower 1.0 Troubleshooting Procedures: First determine the probable cause of the failure. After ruling out an obviously burned-out lamp, wiring problem, or incorrect engine speed, the fault may be reduced to one of two causes either a malfunctioning generator or a problem with the circuits that supply operating power to the lamps. The simplest way to test if the generator is operating properly is to measure the voltage at the power outlet receptacle (see Section 1.10). If the correct voltage is measured at the receptacle then it may be determined that the generator is operating properly. No voltage, low or intermittent voltage at the receptacle may indicate a malfunctioning generator, or it may merely be an indication of something as simple as a problem with the receptacle (damaged receptacle, loose wiring, etc.). If there is no power at the receptacle, it will then be necessary to test the voltage at the main breaker (see Section 1.11). This will help determine if the problem is with the generator or the lamp power circuits. No power (or low power) at the main breaker indicates the generator is not functioning properly, or that there may be a problem in the generator wiring. Proper voltage at the main breaker indicates that the generator is functioning and that the problem is likely in the circuits that provide power to the lamps. Following sections of this manual will guide the technician through the processes used to isolate and correct the cause of the problem. The schematics on the following pages should be used as the basis for troubleshooting the Night Lite PRO II light tower. The diagrams show the various components, their relative location in the electrical circuit and how they are connected. The components shown on the schematic diagrams include: Generator Generator Capacitor Control Box 120 VAC 20A GFCI Receptacle Receptacle Pop-Out Circuit Breaker 240 V 30A Receptacle (Optional) 30A Two-Pole Circuit Breaker (Optional) Main Circuit Breaker Lamp Circuit Breaker Switches Ballast Boxes Ballast Transformers Ballast Capacitors Tower Wiring Light Bar Wiring Lamps (4 X 1250 Watt Metal Halide) Page 2

1.1.1 Wiring Schematic: Page 3

1.1.2 Wiring Schematic: Page 4

1.1.3 Wiring Schematic: Page 5

1.1.4 Wiring Schematic: Page 6

1.1.5 Wiring Schematic: Page 7

1.1.6 Wiring Schematic: Page 8

1.2 Continuity Testing Procedure Continuity must be tested when the engine is not running. Continuity is tested using a multimeter set to the Ohm scale. Place one lead of the multimeter at one end of the wiring or device being tested, and the other lead on the other end. 1.3 Resistance Testing Procedure: A meter reading of less than one ohm indicates continuity. A reading greater than one ohm indicates that the continuity is compromised in the wiring or device being tested and that it must be repaired or replaced. Resistance must be tested when the engine is not running. Resistance is tested using a multimeter turned to the Ohm setting. Touch the two leads across the device or wiring being tested and note the resistance reading on the display. 1.4 Voltage Testing Procedure: 1.5 Flowcharts: Voltage must be tested when the engine is running. WARNING: Dangerous voltage and/or current may be present when a voltage test is being conducted. To reduce the risk of serious injury or death from electrical shock, if you are not trained to safely work with high voltage, do not attempt any of these procedures. You must seek assistance from qualified personnel. Voltage is tested using a multimeter turned to the Volt setting (use AC Volt setting to test voltage from the generator or lighting circuits). If there are several voltage scales, begin by using the highest scale on the meter, then work down to a lower scale until the most accurate reading is obtained. Using a setting that is too low for the voltage being tested may cause damage to the meter. Use the flowcharts on the following pages to help isolate the cause of the problem. References to more detailed instructions in this troubleshooting guide are indicated on the chart as required. Page 9

1.6 Flowchart: Lamps do not function properly Lamp(s) do not light up Is circuit breaker switched to the ON position? Switch circuit breaker ON Do lamps appear to be broken, black or burnt? Replace lamps Do lamps flicker but fail to fully illuminate? Check engine RPM (See Section 1.12) Do lamps fully illuminate but randomly quit working? Check engine RPM (See Section 1.12) Re-set engine RPM (See Section 1.12) Is engine RPM correct? Go to Section 1.7 Page 10

1.7 Flowchart: Lamps do not function properly From Section 1.6 Is input voltage to main circuit breaker 120 V (± 10 %) per leg? See Section 1.9 Is output voltage from main circuit breaker 120 V (± 10 %) per leg? Replace main circuit breaker Is input voltage to each lamp circuit breaker 120 V (±10%)? Repair or replace wiring from main breaker Is output voltage from each lamp circuit breaker 120 V (±10%)? Replace lamp circuit breaker(s) Go to Section 1.8 Page 11

1.8 Flowchart: Lamps do not function properly From Section 1.7 Check input voltage at ballast capacitor(s). TE: Disconnect capacitor output lead before checking capacitor input or output voltage readings. Is input voltage to ballast capacitor(s) 400 V (±10%)? Check tower wiring for cuts or shorts. Check continuity of tower wiring from capacitors to light bar. Remove lamp(s) and check continuity of wiring from light bar to each lamp socket. Check output voltage at ballast capacitor(s). TE: Disconnect capacitor output lead before checking capacitor input or output voltage readings. Is output voltage from ballast capacitor(s) 400 V (±10%)? Replace ballast capacitor(s) Repair or replace damaged wiring. Check wiring from lamp circuit breakers to ballast transformers. Input voltage to each ballast transformer should be (120V ±10%). Check output voltage from each ballast transformer and wiring to ballast capacitor. Output voltage should be 400 V (±10%). Are ballast transformer input and output voltages in range? Repair or replace damaged wiring. Page 12

1.9 Flowchart: Lamps do not function properly Testing generator output no voltage (or low voltage) to main circuit breaker. Test generator output directly at generator terminals (See service manual relative to the specific generator model for terminal location). Is generator output 120 V (±10%) per leg? Test generator capacitor (see generator capacitor test procedure Section 1.13) Repair or replace wiring from generator to main circuit breaker. Replace generator capacitor with new capacitor of same rating. Does generator capacitor test procedure indicate capacitor is within spec? See service manual relative to specific generator make and model for major troubleshooting and testing procedures. Page 13

1.10 Testing generator output at the GFCI receptacle WARNING: Dangerous voltage and/or current may be present when a voltage test is being conducted. To reduce the risk of serious injury or death from electrical shock, if you are not trained to safely work with high voltage, do not attempt any of these procedures. You must seek assistance from qualified personnel. Generator output may be simply tested by using a multimeter to measure the voltage across the terminals of the GFCI power receptacle. To test the power output at the GFCI receptacle, the engine must be running and the main breaker and the receptacle breaker must be switched to the ON position. Set the multimeter to the AC Volt position and insert the probe tips into the hot and neutral sides of the GFCI receptacle. (See Figure 1.10-A) A meter reading of 120.0 volts ±10% indicates that the generator is operating properly. Refer to flowchart (Section 1.6 forward) for further troubleshooting procedures A reading less than 120 Volts ± 10% indicates that the generator may be malfunctioning, or that there may be a problem with the main circuit breaker, the pop-out receptacle circuit breaker, the GFCI receptacle itself, or the wiring in between any of these. Refer to flowchart (Section 1.6) for futher procedures. TE: Many Allmand light towers designed for use outside of North America operate at 230 Volts / 50 Hz. Testing is done the same way following the above instructions. If you are unsure which voltage your light tower is designed to produce contact a qualified electrician for assistance. Page 14

1.11 Testing Generator Output at Main Circuit Breaker WARNING: Dangerous voltage and/or current may be present when a voltage test is being conducted. To reduce the risk of serious injury or death from electrical shock, if you are not trained to safely work with high voltage, do not attempt any of these procedures. You must seek assistance from qualified personnel. If testing the generator output at the GFCI receptacle (Section 1.10) shows zero or low voltage, or is inconclusive, it will then be necessary to test the generator voltage at the main circuit breaker. The main breaker itself may also be tested for proper function during this procedure. To access the main breaker, with the engine off, remove the four screws holding the control panel face plate in place and carefully pull the face plate away from the control panel box. Allow the face plate to hang from the attached wiring. CAUTION Do not allow any of the terminals on the control panel face plate contact the control panel box or any other metal object on the trailer. Set your multimeter scale to AC Volts. Start the engine. When the engine has reached its full operating speed touch one multimeter probe to the ground stud, and the other probe to one of the top (input) terminals on the main breaker. Repeat the test for both terminals (see Figure 1.11-A and 1.11-B). 120 Volts ±10% must be measured at each terminal. If 120 Volts ±10% is not measured at each terminal, either the generator, the generator capacitor or the wiring from the generator to the main circuit breaker is faulty. Refer to the troubleshooting flowchart (Section 1.6 forward) to further isolate the problem. If the above procedure indicates proper voltage at the top (input) terminals of the main breaker, test the voltage at the bottom (output) main breaker terminals (see figures 1.11-C and 1.11-D next page). The meter reading should indicate 120 Volts ±10%. If a reading of 120 Volts ±10% is not measured at each terminal, the main breaker is faulty and must be replaced. Contact Allmand Parts Department (308-995-4495 or 1-800-562-1373) for correct replacement circuit breaker Figure 1.11-A. Figure 1.11-B Page 15

1.11 Testing Generator Output at Main Circuit Breaker (continued from previous page) WARNING: Dangerous voltage and/or current may be present when a voltage test is being conducted. To reduce the risk of serious injury or death from electrical shock, if you are not trained to safely work with high voltage, do not attempt any of these procedures. You must seek assistance from qualified personnel. Figure 1.11-C Figure 1.11-D Page 16

1.12 Testing engine speed at the GFCI receptacle WARNING: Dangerous voltage and/or current may be present when this test is being conducted. To reduce the risk of serious injury or death from electrical shock, if you are not trained to safely work with high voltage, do not attempt any of these procedures. You must seek assistance from qualified personnel. The operating speed of the engine may be tested by using a mutimeter with the scale set to read Hertz (HZ). TE: Not all multimeters have a Hertz scale. Set the multimeter to the Hertz (or HZ) scale. With the engine running and the light breakers switched off, insert the meter probes into the GFCI receptacle as shown on the following page (Figure 1.12-A). The meter should read 62.0 Hertz with no load on the engine. A reading of less than 62.0 Hertz indicates that the engine is not running with enough speed to create the necessary power to operate all of the lamps consistently. Slow engine speed may be caused by a number of factors: A. Incorrectly adjusted engine governor. Adjust governor as shown on the following page (Figure 1.12-B) until a reading of 62.0 HZ is indicated on the multimeter display B. Clogged or dirty Air and/or Fuel Filters. Replace filters if there is any question as to their condition. C. Dirty fuel. Drain fuel tank and fuel system and replace with known clean fuel. Replace Fuel Filter before re-starting the engine. D. Worn or damaged engine. If the above steps fail to correct the engine speed this may indicate a faulty engine. Contact your local servicing dealer for the make and model diesel engine in your light tower. Repair, rebuild or replace as necessary. TE: Many Allmand light towers designed for use outside of North America operate at 230 Volt ± 10%s / 50 Hz. Engines on these models must be set for 52.0 HZ at no load per the above instructions. If you are unsure which voltage your light tower is designed to produce contact a qualified electrician for assistance. Continued on following page Page 17

1.12 Testing engine speed at the GFCI receptacle (continued from previous page) WARNING: Dangerous voltage and/or current may be present when this test is being conducted. To reduce the risk of serious injury or death from electrical shock, if you are not trained to safely work with high voltage, do not attempt any of these procedures. You must seek assistance from qualified personnel. Figure 1.12-B TE: Consult service manual for the make and model diesel engine in your light tower for specific governor adjustment instructions. Page 18

1.13 Testing ballast and generator capacitors Disconnect both capacitor leads WARNING: Capacitors can store very high voltage. Hazardous voltage may be present prior the capacitor being discharged. To reduce the risk of electrical shock, do not touch both capacitor terminals at the same time, be certain to handle the capacitor carefully and use a tool with an insulated handle to discharge the capacitor before testing. Do not touch the bare metal of the tool when discharging. Using a screwdriver or similar instrument with an insulated handle, short the capacitor between the terminals to discharge any stored power (Figure 1.14A). The capacitor may be freely handled after it has been discharged. Set the Ohms scale on your multimeter to the highest setting. Check the resistance between the capacitor terminals (Figure 1.14B). A. If the meter shows a low resistance reading which gradually increases, the capacitor is likely good and does not need to be replaced. B. If the meter shows a very high resistance that remains steady, the capacitor is open and must be replaced. C. If the meter indicates a very low resistance that remains steady, the capacitor is shorted and must be replaced. Page 19

1.14 General Information The procedures outlined in this bulletin are general in nature and assume a reasonable level of knowledge and experience on the part of the technician attempting these troubleshooting procedures. If you are unfamiliar with or uncomfortable working with electricity, do not attempt any of these procedures yourself. Contact a qualified electrician or other qualified personnel to carry out the testing and repair procedures outlined in this manual. For further assistance, please contact the Allmand Service Department at: 308-995-4495 Phone 800-562-1373 Toll-Free Electrical System Troubleshooting 1.15 Notes Page 20

1.15 Notes Page 21