Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Similar documents
Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

D509E. Manual Motor - Starters

Micro Contactor MA Series

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Capacitor Switching Contactors Type K3...-A, K3...-K

CI-TI Contactors and motor starters Types CI 61 - CI 98

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

4 - Miniature controls

Bulletin 193-T1 Bimetallic Overload Relays

Technical Information

Contactors RAST 5 D778E131

Contactors Motor-Starters D677E121

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

SIRIUS 3RU2 Thermal Overload Relays

Technical data for manual motor starters Type MS325

3RT14 Contactors with 3 Main Contacts

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Thermal Overload Relays - WEG RW Series, 2 Pole

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Selection Guide Motor Control Device Solutions

AF40... AF96 3-pole contactors Technical data

Low voltage switch gear

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

General Catalogue. Quality made in D946E173

Motors Automation Energy Transmission & Distribution Coatings. Automation Contactors - CWM Line

Manual Motor Starters. Meta-MEC

Overloadrelay,10-16A,1N/O+1N/C. Articleno

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

3VU13, 3VU16 Circuit-Breakers

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

Index. Page. General 4 Approvals 5 Technical Information 9 Mounting Information 10

Essential equipment for all your requirements

Modular contactor for installation into distribution boards

Contactor Types CI 61-98

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Electronic overload relays EF205 and EF370

CA Z-EN Overload relays, CT-operated overload relays

Modular Contactors and Switches D681E121

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

FMotor Circuit Controllers

06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

Deliveryprogramme. Overloadrelay,6-9A,1N/O+1N/C. Articleno CatalogNo. XTOM009AC1. Settingrange. Auxiliarycontacts. Short-circuitprotection

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

CI-TI Contactors and Motor Starters Type CI 6-50

Application Mini Contactors for Motors and Resistive Loads

Siemens AG Switch Disconnectors SENTRON. Configuration. Edition 10/2015. Manual. siemens.com/lowvoltage

Technical Information

General_technical_data Series

Electronic overload relay EF65, EF96 and EF146

3 - Protection components Motor circuit-breakers

Special Purpose Fuses

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

General Informations 2 Technical data 3 Basic designs 4-8

Mini DC - Isolators for Photovoltaic

Short form catalogue. Motor protection & control

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

27Overload Relays. Overview Combinations of overload relays and contactors SIRIUS 3R. Thermally delayed overload relays CLASS 10

Contact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE

Protection Equipment

Protection Equipment. 5/2 Introduction

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Mini Contactors CI 4-

Thermal overload relay TF65 and TF96

BETA Switching Switches and Light Indicators

Bulletin 825 SMM Smart Motor Manager

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Selective main circuit breakers S 750 series Technical Data

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

Overload Relays. Thermal (Bimetallic) style up to 800A. Overload relay structure

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Industrial Contactors CTX 3 3P 185A - 800A

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Deliveryprogramme. Overloadrelay,24-40A,1N/O+1N/C. Articleno CatalogNo. XTOB040DC1. Auxiliarycontacts. Short-circuitprotection

Components for EEx e Panels

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

MS General Information Extended Product Type: MS

Miniature Circuit-Breakers (MCBs)

MS25, MST25, MS20, MST20

Thermal overload relays Type TA Class 10

KT4 Manual Motor Starter

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Protective Devices: Circuit-Breakers 1 )

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Power Contactor with Mirror Contacts

K30H001YP cam star-delta switch - 3-pole A - screw mounting

Ideal for use as a manual starter

Transcription:

Thermal Overload Relay J7TKN ) Thermal Overload Relay Direct and separate mounting Single phasing sensivity according to IEC 60947-4-1 Finger proof (BGV A2) Accessories Set for single mounting Approved Standards Standard UL IEC 60947-4-1 VDE 0660 EN 60947-4-1 Guide No (US,C) NKCR, NKCR7 Ordering Information Model Number Legend 1. Thermal Overload Relay J7TKN-#-### 1 2 3 1) Thermal Overload Relay 2) A: for mini motor contactor, manual reset AA: for mini motor contactor (auto reset) AB: for motor contactor (4-11 kw; manual reset) B: for motor contactor (4-15 kw; manual and auto reset) C: for motor contactor (18.5 kw) D: for motor contactor (22-37 kw) E: for motor contactor (45-55 kw) F: for motor contactor (75-90 kw) G: for motor contactor (110-160 kw) H: for motor contactor (250-500 kw) 3) Setting range E18: 0.12-0.18 A 24: 17-24 A E27: 0.18-0.27 A 32: 23-32 A E4: 0.27-0.4 A 42: 28-42 A E6: 0.4-0.6 A 52: 40-52 A E9: 0.6-0.9 A 65: 52-65 A 1E2: 0.8-1.2 A 74: 60-74 A 1E8: 1.2-1.8 A 90: 60-90 A 2E7: 1.8-2.7 A 120: 80-120 A 4: 2.7-4 A 180: 120-180 A 6: 4-6 A 216: 144-216 A 9: 6-9 A 320: 216-320 A 11: 8-11 A 360: 240-360 A 14: 10-14 A 540: 360-540 A 18: 13-18 A 800: 540-800 A 2. Accessories for Thermal Overload Relay J74TK-## 1 2 1) Accessories for Thermal Overload Relay 2) SM: Single mounting for J7TKN-B Types (4-32 kw) M-AB: Single Mounting for J7TKN-AB Types (4-11 kw) SU-550: Busbar set for J7TKN-H (250-300 kw) SU-860: Busbar set for J7TKN-H (400-500 kw) Thermal Overload Relay J7TKN 1

System overview Thermal Overload Relays for plug-in mounting Setting Range Type Pack Weight D.O.L. (A) Star Delta (A) pcs. kg/pc. For contactors J7KNA-09..., J7KNA-12... Manual reset 0.12-0.18 - J7TKN-A-E18 1 0.10 0.18-0.27 - J7TKN-A-E27 1 0.10 0.27-0.4 - J7TKN-A-E4 1 0.10 0.4-0.6 - J7TKN-A-E6 1 0.10 0.6-0.9 - J7TKN-A-E9 1 0.10 0.8-1.2 - manual reset J7TKN-A-1E2 1 0.10 1.2-1.8 - J7TKN-A-1E8 1 0.10 1.8-2.7 - J7TKN-A-2E7 1 0.10 2.7-4 - J7TKN-A-4 1 0.10 4-6 7-10.5 J7TKN-A-6 1 0.10 6-9 10.5-15.5 J7TKN-A-9 1 0.10 8-11 14-19 J7TKN-A-11 1 0.10 10-14 18-24 J7TKN-A-14 1 0.10 For contactors J7KNA-09..., J7KNA-12... Auto reset 0.12-0.18 - J7TKN-AA-E18 1 0.10 0.18-0.27 - J7TKN-AA-E27 1 0.10 0.27-0.4 - J7TKN-AA-E4 1 0.10 0.4-0.6 - J7TKN-AA-E6 1 0.10 0.6-0.9 - J7TKN-AA-E9 1 0.10 0.8-1.2 - auto reset J7TKN-AA-1E2 1 0.10 1.2-1.8 - J7TKN-AA-1E8 1 0.10 1.8-2.7 - J7TKN-AA-2E7 1 0.10 2.7-4 - J7TKN-AA-4 1 0.10 4-6 7-10.5 J7TKN-AA-6 1 0.10 6-9 10.5-15.5 J7TKN-AA-9 1 0.10 8-11 14-19 J7TKN-AA-11 1 0.10 10-14 18-24 J7TKN-AA-14 1 0.10 For contactors J7KN(G)-10(D) to J7KN(G)-22(D) or single mounting Auto reset 0.12-0.18 - J7TKN-AB-E18 1 0.10 0.18-0.27 - J7TKN-AB-E27 1 0.10 0.27-0.4 - J7TKN-AB-E4 1 0.10 0.4-0.6 - J7TKN-AB-E6 1 0.10 0.6-0.9 - J7TKN-AB-E9 1 0.10 0.8-1.2 - auto reset J7TKN-AB-1E2 1 0.10 1.2-1.8 - J7TKN-AB-1E8 1 0.10 1.8-2.7 - J7TKN-AB-2E7 1 0.10 2.7-4 - J7TKN-AB-4 1 0.10 4-6 7-10.5 J7TKN-AB-6 1 0.10 6-9 10.5-15.5 J7TKN-AB-9 1 0.10 8-11 14-19 J7TKN-AB-11 1 0.10 10-14 18-24 J7TKN-AB-14 1 0.10 13-18 23-31 J7TKN-AB-18 1 0.10 17-23 30-40 J7TKN-AB-23 1 0.10 22-30 38-52 J7TKN-AB-30 1 0.13 2 Thermal Overload Relay J7TKN

Setting Range Type Pack Weight D.O.L. (A) Star Delta (A) pcs. kg/pc. For contactors J7KN-10D-... to J7KN-22... 0.12-0.18 - J7TKN-B-E18 1 0.14 0.18-0.27 - J7TKN-B-E27 1 0.14 0.27-0.4 - J7TKN-B-E4 1 0.14 0.4-0.6 - J7TKN-B-E6 1 0.14 0.6-0.9 - J7TKN-B-E9 1 0.14 0.8-1.2 - manual and auto reset J7TKN-B-1E2 1 0.14 1.2-1.8 - J7TKN-B-1E8 1 0.14 1.8-2.7 - J7TKN-B-2E7 1 0.14 2.7-4 - J7TKN-B-4 1 0.14 4-6 7-10.5 J7TKN-B-6 1 0.14 6-9 10.5-15.5 J7TKN-B-9 1 0.14 8-11 14-19 J7TKN-B-11 1 0.14 10-14 18-24 J7TKN-B-14 1 0.14 13-18 23-31 J7TKN-B-18 1 0.14 17-24 30-41 J7TKN-B-24 1 0.14 23-32 40-55 J7TKN-B-32 1 0.14 For contactors J7KN-24... to J7KN-40... 22-42 48-73 J7TKN-C-42 1 0.30 manual and auto reset For contactors J7KN-50...-J7KN-74... 40-52 70-90 J7TKN-D-52 1 0.40 52-65 90-112 J7TKN-D-65 1 0.40 60-74 104-128 J7TKN-D-74 1 0.40 manual and auto reset Thermal Overload Relay J7TKN 3

Thermal Overload relays for separate mounting Setting Range Type Pack Weight D.O.L. (A) Star Delta (A) pcs. kg/pc. For contactors J7KN-90... to J7KN-115... 60-90 104-156 J7TKN-E-90 1 0.90 80-120 140-207 J7TKN-E-120 1 0.90 manual reset For contactors J7KN-151... to J7KN-176... (incl. busbar set) 120-180 208-312 J7TKN-F-180 1 1.5 manual and auto reset For contactors J7KN-210... to J7KN-316... (incl. busbar set) 144-216 250-374 J7TKN-G-216 1 1.8 216-320 374-554 J7TKN-G-320 1 1.8 manual and auto reset For contactors J7KN-450... to J7KN-860... (excl. busbar set) 240-360 416-623 J7TKN-H-360 1 4.2 360-540 623-935 J7TKN-H-540 1 4.2 540-800 935-1385 J7TKN-H-800 1 4.2 manual and auto reset Accessories Cable Cross-section to clamp (mm²) Type Pack Weight for overload relay solid or stranded flexible flex. with multicore cable end pcs. kg/pc. Sets for single mounting J7TKN-AB J7TKN-B 0.75-0.75-6 6 0.75-0.75-4 4 0.5 0.5 - - 4 4 J74TK-M-AB J74TK-SM 1 1 0.035 0.035 Type Pack Weight for overload relay for contactors Set Set Busbar sets J7TKN-H-360/540 J7KN-450, J7KN-550 J74TK-SU-550 1 1.7 J7TKN-H-540/800 J7KN-700, J7KN-860 J74TK-SU-860 1 2.1 4 Thermal Overload Relay J7TKN

Specifications Engineering data and Characteristics Thermal Overload Relays, tripping times for selection to motors of protection degree EEx e Relays With Standard Tripping Characteristic Setting Range Tripping time(in seconds) depending on the multiple of the current setting from cold condition (tolerance ±20% of the tripping time) I A /I N I A /I N I A /I N I A /I N I A /I N I A /I N A A 3 4 5 6 7,2 8 J7TKN-A*-... 0,12-0,18 18,5 10,4 7,2 5,5 4,3 3,6 0,18-0,27 16,7 9,8 6,5 5 4,1 3,5 0,27-0,4 19,4 12,1 8,2 5,9 4,9 4,2 0,4-0,6 18,7 11,2 8 6 4,9 4,1 0,6-0,9 19,7 11,6 8,1 6,1 4,9 4,2 0,8-1,2 22,9 13,6 10 7,3 6 5,2 1,2-1,8 22,2 13,2 9,2 7,6 5,8 5,3 1,8-2,7 23 13,7 9,3 7,6 5,7 5,1 2,7-4 24 14,4 9,9 7,8 5,9 5,1 4-6 24,7 13,8 9,9 7,3 5,6 4,8 6-9 22 13,4 8 5,7 4,1 3,5 8-11 17,4 9,2 5,9 4,1 2,9 2,3 10-14 26,4 12,9 7,6 5,2 3,5 2,8 13-18 4,7 7,7 4,8 3,2 2,3 1,7 17-23 16,2 8,4 5,0 3,6 2,4 1,8 22-30 16,8 8,5 5,0 3,6 2,3 1,9 J7TKN-B-... 0,12-0,18 16,1 9,6 6,8 5,3 4,2 3,7 0,18-0,27 16,6 9,7 6,7 5,2 4,1 3,6 0,27-0,4 19,4 11,4 7,9 6,1 4,7 4,2 0,4-0,6 18,7 10,9 7,6 5,9 4,6 4,0 0,6-0,9 19,2 11,2 7,7 5,9 4,6 4,1 0,8-1,2 20,8 12,3 8,5 6,6 5,2 4,6 1,2-1,8 25,5 14,1 9,8 7,6 5,9 5,2 1,8-2,7 26,6 15,6 10,9 8,3 6,5 5,7 2,7-4 22,7 13,6 9,5 7,4 5,8 5,1 4-6 22,2 13,3 9,3 7,1 5,6 4,9 6-9 20,4 11,9 8,2 6,1 4,7 4,0 8-11 20,9 11,8 7,9 5,7 4,3 3,5 10-14 21,3 11,7 7,4 5,1 3,7 3,0 13-18 21,2 12,1 8,0 6,2 4,6 4,1 17-24 20,4 12 8,6 6,3 4,5 3,7 23-32 20,2 10,2 6,7 4,7 3,4 2,8 J7TKN-C-42 28-42 25,2 13,3 8 5,5 4 3,1 J7TKN-D-... 40-52 18,3 9,2 5,6 3,9 2,8 2,2 52-65 17,8 8,7 5,2 3,4 2,5 1,9 60-74 19,5 13,5 11 10 9,5 8,5 J7TKN-E-... 60-90 19,5 13,5 11 10 9,5 8,5 80-120 18 11 10 9 8,5 8 J7TKN-H-... 260-360 23,3 14,1 10,0 7,6 6,1 5,4 340-480 23,0 13,8 9,6 7,6 6,1 5,4 440-620 20,5 12,4 9,0 7,0 5,5 5,0 560-800 21,0 12,5 9,0 7,0 6,6 5,2 When selecting a standard overload, refer to the tripping curve. Determine the values of the starting current ratio I A /I N and the time t E which is marked on the label of the motor. The overload must trip within the t E time, which means that the tripping curve from cold condition must be (20% due to tolerance) below the coordination point I A / I N and the time t E. I A = Starting current of motor I N = Rated current of motor t E = t E -time of motor All tripping times of overload relays J7TKN-A* are shorter than the minimum values of the t E time for motors of protection degree EEx e acc. to EN 50019 and therefore are suitable for all motors of protection degree EEx e. For these overload relays the selection on basis of tripping curves is thereby not necessary. Typical tripping curve for overload relay J7TKN-A* Minimum values of t E time (motor) acc. to EN50019 ratio I A /I N Labels of tripping curves for each setting range, sized 148x105mm (self-adhesive) are available on request. Specify type and setting range. Thermal Overload Relay J7TKN 5

Fuses for J7TKN-A; J7TKN-B; J7TKN-C; J7TKN-D; J7TKN-E; J7TKN-F/G/H Type Setting Range Max. Fuse Size According to Coordinationtype "2" *1 J7TKN-A* J7TKN-B DOL Star Delta quick slow, gl(gg) *1) Coordination-type according to IEC 60947-4-1: 2 : Light contact welding accepted. Thermal overload relay must not be damaged. 1 : Welding of contactor and damage of the thermal overload relay allowed. *2) Miniature fuse Fuse UL Fuse UL (SCCR) "1" *1 Short slow, am gl(gg) Circuit Current Rating A A A A A A A ka 0.12-0.18-0.5 *2 0.5 *2 25-15 5 0.18-0.27-1.0 *2 1.0 *2 25-15 5 0.27-0.4-2 2 25-15 5 0.4-0.6-2 2 25-15 5 0.6-0.9-4 4 25-15 5 0.8-1.2-4 4 25 2 15 5 1.2-1.8-6 6 25 2 15 5 1.8-2.7-10 10 25 4 15 5 2.7-4 - 16 10 25 4 15 5 4-6 7-10.5 20 16 25 6 15 5 6-9 10.5-15.5 35 25 35 10 25 5 8-11 14-19 35 25 35 16 30 5 10-14 18-24 50 35 63 16 40 5 13-18 23-31 50 35 63 20 50 5 17-24 30-41 63 50 63 25 60 5 23-32 40-55 80 63 80 35 70 5 J7TKN-C 28-42 48-73 100 80 150 50 110 5 J7TKN-D 40-52 70-90 160 100 150 63 200 5 52-65 90-112 160 125 150 80 250 10 60-74 104-128 160 125 150 80 250 10 J7TKN-E 60-90 104-156 For short circuit protecting overload relays 300 10 80-120 140-207 with current transformer use fuse according to the contactor of the combination. - - J7TKN-F/G/H all ranges - - 6 Thermal Overload Relay J7TKN

Tripping Characteristics for J7TKN-A*, J7TKN-B, J7TKN-C, J7TKN-D Detailed tripping times for each range see table page 5 with three-phase load with two-pole load Tripping time min. s Average value of typical tolerance curves from cold condition Proceeding from service conditions the times decrease to 20-30% of the characteristic values Tripping time min. s Typical tolerance curve from cold condition Proceeding from service conditions the times decrease to 70-80% of the characteristic values K = Imax/Ie Imax = max. phase current Ie = max. scale value F.L.C. multiplication factor K Tripping Characteristics for J7TKN-E Detailed tripping times for each range see table page 5 with three-phase load with two-pole load Tripping time min. s Average value of typical tolerance curves from cold condition Proceeding from service conditions the times decrease to 20-30% of the characteristic values Tripping time min. s Typical tolerance curve from cold condition Proceeding from service conditions the times decrease to 70-80% of the characteristic values K = Imax/Ie Imax = max. phase current Ie = max. scale value F.L.C. multiplication factor K Thermal Overload Relay J7TKN 7

Tripping Characteristics for J7TKN-F, J7TKN-G Detailed tripping times for each range see table page 5 with three-phase load Tripping Characteristics for J7TKN-H Detailed tripping times for each range see table page 5 with three-phase load Position of Terminals J7TKN-A J7TKN-B J7TKN-C; J7TKN-D 8 Thermal Overload Relay J7TKN

Thermal Overload Relays Data according to IEC 60947-4-1, IEC 60947-5-1, VDE 0660, EN 60947-4-1, EN 60947-5-1 Type Rated insulation voltage U i *1 J7TKN-A(B) J7TKN-AA J7TKN-B J7TKN-C J7TKN-D J7TKN-E J7TKN-F J7TKN-G J7TKN-H V~ 690 690 690 690 690 750 1000 1000 1000 Permissible ambient temperature operation open C -25 to 60-25 to 55 storage C -50 to 70-40 to 70 Trip class according to IEC 60947-4-1 10A 10A 10A 10A 10A 20 10A 10A 10 Cable cross-section main connector solid or stranded mm² 0.75-6 + 0.75-2.5 *2 0.75-6 + 0.75-2.5 *3 *2 *4 0.75-6 0,75-10 4-35 Busbar Busbar *5 flexible mm² 0.75-4 + 0.5-2.5 *2 0.75-4 + 0.5-2.5 *2 1-4 0,75-6 6-25 *2 18 4 25 6 flexible with multicore cable end mm² 0.5-2.5 + 0.5-1.5 0.5-2.5 + 0.5-1.5 0.75-4 0.75-6 4-25 Screw M8 Cables per clamp number 1+1 1+1 2 2 1 1 1 auxiliary connector solid mm² 0.75-2.5 *2 1-2.5 *2 flexible mm² 0.5-2.5 *2 1-2.5 *2 flexible with multicore cable end mm² 0.5-1.5 1-2.5 *2 Cables per clamp number 2 2 Auxiliary contacts Rated insulation voltage U i *1 same potential V~ 690 690 690 690 690 690 690 690 500 different potential V~ 440 440 440 250 250 440 440 440 500 Screw M10 Utilization category AC15 Rated operational current I e 24V A 5 5 3 4 *6 4 *6 5 3 3 4 *7 230V A 3 3 2 2.5 2.5 3 2 2 2.5 400V A 2 2 1 1.5 1.5 2 1 1 1.5 690V A 0.6 0.6 0.5 0.6 0.6 0.6 0.5 0.5 0.6 Utilization category DC13 Rated operational current I e 24V A 1.2 1.2 1 1.2 1.2 1.2 1.2 1.2 1.2 110V A 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 220V A 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 Short circuit protection (without welding 1kA) highest fuse rating gl (gg) A 6 6 4 6 6 6 4 4 6 Setting range A to 23 to 23 all 28-42 52-65 all - - - Power loss per current path (max.) minimum setting value W 1.1 1.1 1.1 1.3 2.9 1.1 - - - maximum setting value W 2.3 2.3 2.3 3.3 4.5 2.5 - - - *1) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry: U imp = 4kV (at 440V), 6kV (at 690V). Data for other conditions on request. *2) Maximum cable cross-section with prepared conductor *3) Maximum cable cross-section with prepared conductor *4) Without terminals, suitable for bushing one connector 70mm² (stranded) per phase *5) Busbar sets see accessories page 4 *6) Switching capacity of the start contact: AC15 300VA, max. 1.5A, DC13 (max. 220V) 30W, max. 1.5A *7) Switching capacity of the make contact: AC15 400VA, max. 1,7A, DC13 (max. 220V) 10W, max. 1A Thermal Overload Relay J7TKN 9

Data according to CULUS Type J7TKN-A J7TKN-B J7TKN-C J7TKN-D J7TKN-E Rated insulation voltage V~ 600 600 600 600 600 Rated current A 23 32 42 74 85 Auxiliary contacts Rated voltage same potential V AC 600 600 600 600 600 different potential V~ 150 150 150 150 150 Switching capacity AC VA 500 500 600 600 600 of aux. contacts A 4 2 4 4 4 Temperature Compensation In case of higher ambient temperature use the following formula: (Ambient temperature - 20) 0.125 = correction factor in % of the full load motor current Dimensions J7KNA-09 + J7TKN-A(A) J7KNA-12 Example: Ambient temperature 70 C, full load motor current 7A (70-20) 0.125 = 6.25% Setting value: 7A + 6,25% = 7.44A J7KN-10D + J7TKN-AB J7KN-14D J7KN-18D J7KN-22D J7KNG-10 + J7TKN-AB J7KNG-14 J7KNG-18 J7KNG-22 J7KN-10D + J7TKN-B J7KN-14D J7KN-18D J7KN-22D 10 Thermal Overload Relay J7TKN

J7KNG-10 + J7TKN-B J7KNG-14 J7KNG-18 J7KNG-22 J7KN-24 + J7TKN-B J7KN-32 J7KN-40 J7KNG-24 + J7TKN-B J7KNG-32 J7KN-24 + J7TKN-C J7KN-32 J7KN-40 45 35 86 108 104 Ø4.5 80 M5 149 64.5 M3.5 6.5 M3.5 12 J7KNG-40 + J7TKN-C 3 34 55 J7KN-50 + J7TKN-D J7KN-62 J7KN-74 5 45 35 120 104 86 4.5 M5 144 63 80 M3.5 6.5 M5 M3.5 23 67 68 72 Thermal Overload Relay J7TKN 11

J7KN-90 + J7TKN-E J7KN-115 J7KN-151 + J7TKN-F J7KN-176 J7KN-210 + J7TKN-G J7KN-260 J7KN-316 J7TKN-H with A B C D E F G H J K J7KN-450 220 372 110 220 158 40 185 225 12,5 9 J7KN-550 220 395 110 220 158 40 185 225 12,5 9 J7KN-700 280 487 175 280 202 50 257 291 14,5 11 J7KN-860 280 540 175 280 202 50 257 291 14,5 11 12 Thermal Overload Relay J7TKN

J74TK-M-AB J7TKN-AB + J74TK-M-AB for snap-on 35 mm DIN-rail according to DIN EN50022 and screw mounting (single mounting) Thermal Overload Relay J7TKN 13

Do not use/install these products before having read the applicable precautions as listed in Cat. No. J09-EN-01 available from www.europe.omron.com or on request from OMRON local sales office. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. Cat. No. J07E-EN-04A In the interest of product improvement, specifications are subject to change without notice. 14 Thermal Overload Relay J7TKN