Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE


MC, THHN/THWN-2 Copper

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

STABILOY BRAND FeeDeR SOLuTIONS

Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

G20GB12 Gry 3W1CKT Plugmold. Features Made in USA STEEL RACEWAY, THERMOPLASTIC RECEPTACLE Number of Outlets 48 Outlet Center Distance

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

TC-RHH/RHW-2 USE-2 Copper

Additional Information TRADE NAME PERIWINKLE; STRANDING 7 (PHASE), 6/1 (NEUTRAL); WEIGHT 272 LB PER 1000 FT

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

ATHLETIC STADIUMS AND SPORTS ARENAS

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

A 120V BR GFI Recpt. Features. Material, Color, and Finish. Description

MC or MV-105 Copper, TR-XLPE Insulated

CH120CAFPN 1P 20A 120 Combo Arc Fault PN Breaker

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Varnished Cambric Tape 3/4"X60' Features. Material, Color, and Finish. Dimensions and Weight. Long Description. Manufacturer Information

Primary, Secondary, Post-Secondary Education Facilities

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

SPECIFICATION HIGH IMPACT RESISTANT THERMOPLASTIC

HOSPITAL AND HEALTHCARE

561LVB 561LVB 4 Oct Box W/Bracket. Features. Dimensions and Weight. Description. Manufacturer Information. Taxonomies, Classifications, and Categories

NEC 2014 Code Changes

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

G20GB606 PLGMD 6'SGL CRT 6" 2000 Gray. Manufacturer Information. Packaging Carton 1 Package 2 Weight Per each Description

Open-Style Power Distribution Blocks

TUNNELING POWER CABLES

Uses, Certifications, and Standards STRUT FITTINGS,BF-FTGS,MISCELLANEOUS

TCI5125 Dusttight Grip " 1.50"NPT Ins

TA Ta VA CTRL-XFRMR

Category # 1 - Overhead, Primary, & Secondary Conductors

5-1/2 INCH L X 4-1/8 INCH W X 6 INCH H

N0N A 250V One-Time Class H Fuse

ACP1034CD 100A 3W4P P&S Plug (600VAC/250VDC)

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

Mecklenburg County Common Code Defects

2016 Photovoltaic Solar System Plan Review List

EPOXY POWDER COATED COPPER FREE ALUMINUM

ACP6034BC 60A 3W4P P&S Plug (600VAC/250VDC)

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

SW Tog DP 30A 120/277V Autogrd B&S WH

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

Easier! Faster! Safer!

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

PRODUCT INFORMATION H07V-K

R6F30A1S R6F30A1S 1P 60A 600V Fuse BLK. Features. Long Description

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

Variable Frequency Drive (VFD) Cable Solutions

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

PART A General Conductor Requirements

IEEE 1580 TYPE T/N CABLE

The Reliable Choice. Field Pocket Guide

C-L-X Aluminum Sheath Type IEC

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

24HR 30A SPST TM SW. Features. Long Description

Spring Test 10 due 05/11/2013

DIVISION 16 - ELECTRICAL SECTION 16xx0 MANUFACTURED WIRING SYSTEM ACCESS FLOOR

Medium Voltage Power Cables

See Part 3 for the Introduction for Article 314

Open-Style Power Distribution Blocks

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

Electrical Design/Build Guide

ELECTROGALVANIZED ALUMINUM ACRYLIC PAINTED FERALOY[R] IRON ALLOY (US), COPPER FREE ALUMINUM (CANADA)

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

RENEWABLE ENERGY. Alcan cable solutions

Have You Been Grounded Lately

Omni Cable is a master distributor of specialty wire and cable selling

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

G4047BM 2G Gry Cover Plate

Electrical Tech Note 106

DLO. Mining Cable. Mining Cable. 2 kv

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Description Fan Blade, Size 52 Inch; Dark Oak; Standard Package 5; Craftmade[R] Brand

Section 11 Mining Cable

Transcription:

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Catalog Number Manufacturer Description Weight per unit Product Category MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor Southwire Company MC122IG Southwire Company Isolated-Ground Aluminum Interlocked Armor Copper Cable, MC; 600 V Voltage Rating; 20 Ampere Current Rating; Conductor Material Soft Drawn Copper; 12 Awg Conductor; 2 Conductor(S); Solid; PVC Jacket; Lightweight Aluminum Armor 0.1400 (lbs/ft) Alum Armor Copper Conductors Features Conductor Size 12 AWG Current Rating 20 AMPERE Ground Conductor Type 12 AWG SOLID GREEN INSULATED Number of Conductors 2 Stranding SOLID Voltage Rating 600 V Material, Color, and Finish Armor Material Color Code Insulation Material Jacket Material Dimensions and Weight Length 250 FT Length in ft 250 Outer Diameter 0.475 INCH Descriptions Commodity Description Description Long Description Product Type LIGHTWEIGHT ALUMINUM GREEN THHN/THWN PVC Manufacturer Information Brand Aluminum GTIN 00032886027062 Manufacturers Part Number 69596501 UPC 032886027062 ALUM ARMOR CU CONDCTOR-AC90-CORFLEX 12/2 WG MC SOLID-ISOLATED GROUND,STEEL ARMOR ISOLATED-GROUND ALUMINUM INTERLOCKED ARMOR COPPER CABLE, MC; 600 V VOLTAGE RATING; 20 AMPERE CURRENT RATING; CONDUCTOR MATERIAL SOFT DRAWN COPPER; 12 AWG CONDUCTOR; 2 CONDUCTOR(S); SOLID; PVC JACKET; LIGHTWEIGHT ALUMINUM ARMOR Metal Clad Cable

3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 AllenWatson@elliottelectric.com Taxonomies, Classifications, and Categories Category Description BX & MC Type MC Packaging Carton 250 Package Type COIL Weight 104 LB/MFT Weight Per each 0.14 Uses, Certifications, and Standards Approval UL 83, UL 1569 Temperature Rating 75 DEG C (WET), 90 DEG C (DRY)

Armorlite Type MC Isolated Ground Lightweight Aluminum Interlocked Armor. 600 Volts. Copper Power Conductors. THHN/THWN Insulated Singles. Two Insulated Grounding Conductors. Sizes 12 AWG and 10 AWG. Rated VW-1. APPLICATIONS Southwire Armorlite Type MC Cable - Isolated Ground is suitable for use as follows: Applications requiring redundant, dedicated or isolated grounding paths. Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings. Power, lighting, control, and signal circuits. For sensitive electronic equipment. Fished or embedded in plaster. Concealed or exposed installations. Environmental air-handling spaces per NEC 300.22 (C). Places of Assembly per NEC 518.4 and theaters per NEC 520.5. Installation in cable tray and approved raceways. Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations. STANDARDS & REFERENCES Southwire's Armorlite Type MC Cables - Isolated Ground meet or exceede the following requirements UL 83 UL 1569 UL 1685 Federal Specification A-A59544 (formerly J-C-30B) The National Electrical Code Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems Jacketed & Non Jacketed will both pass " UL Test" & "FT4/IEEE 1202" (70,000 Btu/hr) Vertical Cable Tray Flame Test CONSTRUCTION Southwire Armorlite Type MC Cable - Isolated Ground is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90 C dry available in sizes 12 AWG and 10 AWG, and two insulated grounding conductors--one solid green and the second green with yellow stripes. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly. The standard PVC Jacket will not meet "Limited Smoke" or "LS" Rating. An optional SOLONON Jacket can be provided for "LS" Rating. Tue Jan 24 11:05:01 EST 2012 Page 1 of 3

Armorlite Type MC - Isolated Ground Circuit Conductor Size (AWG)/# of Cond. Solid or Stranded Grounding Conductor Size (AWG)/# of Cond. Approx. Weight (lbs./1000) Approx Armor O.D. (Inches) Coil Length (feet) Reel Length (feet) Ampacity 12/2 solid 12/2 131 0.505 250 1000 20 12/3 solid 12/2 157 0.539 250 1000 20 12/4 solid 12/2 186 0.574 250 1000 20 10/2 solid 10/2 193 0.580 250 1000 30 10/3 solid 10/2 233 0.623 250 1000 30 10/4 solid 10/2 276 0.668 250 1000 30 12/2 stranded 12/2 137 0.527 250 1000 20 12/3 stranded 12/2 165 0.564 250 1000 20 12/4 stranded 12/2 194 0.602 250 1000 20 10/2 stranded 10/2 201 0.607 250 1000 30 10/3 stranded 10/2 243 0.653 250 1000 30 10/4 stranded 10/2 288 0.701 250 1000 30 Note: Ampacities are based on Table 310.16 of the NEC, 2011 Edition. Allowable ampacities shown are for general use as specified by the National Electrical Code, 2011 Edition, Section 310.15. If the equipment is marked for use at higher temperatures, the conductor ampacity shall be limited to the following per NEC 110.14(C). 60 C - When terminated to equipment for circuits rated 100 amperes or less or marked for size 14 through 1 AWG conductors. 75 C - When terminated to equipment for circuits rated over 100 amperes or marked for conductors larger than size 1 AWG. 90 C - For ampacity derating purposes. Per NEC 310.15(B)(2)(a), the ampacity of 4/C cables shall be reduced by a factor of 0.80 when the neutral is considered a current-carrying conductor. FEATURES An additional grounding conductor for isolated or redundant grounding. Reduces installation costs up to 50% over pipe and wire. Lightweight aluminum armor--as much as 45% lighter than steel MC Cable. UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038. Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation. Available in full line of product sizes and constructions. Anti-short bushings are not required for use with MC cable per the NEC and UL Tue Jan 24 11:05:01 EST 2012 Page 2 of 3

Armorlite Type MC - Isolated Ground ONLINE CERTIFICATIONS & TOOLS UL Online Certification Directory ( www.ul.com ) UL Online Product Guide Info - Metal-Clad Cable (PJAZ) ( www.ul.com ) Tue Jan 24 11:05:01 EST 2012 Page 3 of 3