HIGH POWER SOLENOID DRIVER 1

Similar documents
ELECTRIC SCHEMATICS LS1 LS2. "1532ES / 1932ES" Service & Parts Manual - ANSI Specifications March 2008 Page 5-9 ART_2236 ART_2243

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

Electronic Ballast EVG 2000-T

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

TECHNICAL DESCRIPTION

J1 Plug Pin Identification

J1 Plug Pin Identification

The galvanic separation of the primary or actuating circuit and the load circuits

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

J1 Plug Pin Identification

ATOTH-G Series BLDC Motor Controller. User s Manual

AF series contactors (9 2650)

Automated Circuit Breaker Calibration

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

Electronic Limit Switch Type

VASCO. Variable Speed Controller ENGLISH

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

AF series contactors (9 2650)

Addendum to the Catalog Diagnostic unit /DUE for function and wear monitoring of brakes BE.., BF.., BT..

CHARGE CONTROLLER C C S B 2

EPS/ELA-Series User Manual EPS/ELA 250W

GS2 Series - Introduction

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

OIS21C. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

TRAC-3 TENSION READOUT AND CONTROL

Electromagnetic Flowmeters. Product Overview.

CARRARO TRAX TLB2 Electronic Module Specification. 29/11/2006, Rev. 5

Continental Hydraulics Installation Manual CEM-AA-A

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Brushless DC Motor Systems FBL2 Series

TECHNICAL DATASHEET#TD1516AX 3 AMP SOLENOID DRIVER

Safety Sensor CSS 180 Product Information

TROUBLESHOOTING TP. Index

INDUCTIVE CONDUCTIVITY SENSOR. Instruction Manual. Bürkert 2001 Subject to technical change without notice

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

ECONOMISER SERIES E2T USER MANUAL

QS20.241, QS C1

Power Electronics. Motor brake relay GA 9031 ministop

AA4006 Speed Sensitive Trip Unit. User Manual

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Timer Relays - Fixed & Adjustable

Explanation 1 Input External Switch 2 Input Hipot Safety Switch

Controller over electromechanical fuel dispensers for petrol stations

USERS MANUAL MCD REMOTE OPERATOR

P33T Series Redundant Safety Exhaust Valve ENGINEERING YOUR SUCCESS. Bulletin 0700-B13.

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

ULTRASONIC FLOW SENSOR IFX-M4-01

Power Electronics. POWERSWITCH Semiconductor Relay / - Contactor With Load Circuit Monitoring PH 9270

Hydraulic Valves «DSV»

ESD5500E Series Speed Control Unit

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

CENTROIDTM. AC Brushless Drive. Product Spec Sheet


Technical Data Sheets

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm

Technical Data Sheets

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

Kelly KDHA High Voltage Series/PM Motor Controller User s Manual

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Appendix: Safety and application notes for... 15

15A (2 Form C), 10A (4 Form C) COMPACT POWER RELAYS WITH HIGH SENSITIVITY

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz

ESD5550 / 5570 Series Speed Control Units

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

Example of Combining Different Types of Heater Control. Heater control. Temperature Controller

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

Electromagnetic clutch-brake combinations INTORQ

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

Illuminator Series CR NEMA 3R

ThunderION. Static Neutralising System. GB User's Manual 2

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

CENTRIFEEDER ELECTRONICS

SPEED SHIFT/TWO-STEP MODULE INSTALLATION MANUAL

Electronic Dynamo Regulator INSTRUCTION MANUAL. COPYRIGHT 2015 CLOVER SYSTEMS All Rights Reserved

Flight Systems. Replacement for KASSEC DESCRIPTION

Transparent and Functional Motors Application AEL-FTM

CI-TI Contactors and Motor Starters Type CI 6-50

HFB - Airflow Management Damper. Halton HFB. Airflow Management Damper

Adjustable Torque Controls

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

ADJUSTABLE FREQUENCY CRANE CONTROLS

Phoenix Inverter

Transcription:

Elactis SA Switzerland Phone : Fax : E-mail : Web : +41 22 364 65 85 +41 22 364 65 87 info@elactis.com http://www.elactis.com HIGH POWER SOLENOID DRIVER 1 ADRV1012K 1 This datasheet is a preliminary description. Values and functions may change without notice. 2009 Elactis SA. All rights reserved. 1/6 released on: 01/02/2010

Features - Controlled pull-in and hold power to solenoid - Fast turn-off - Wide input voltage range from 20V to 120V - High power capability with up to 25A pull-in current - Up to 2A hold current - 2 wires or external input operation - Programmable parameters - Solenoid diagnostics with LED and status output Description The ADRV1012K is a sophisticated driver for solenoids and solenoid valves. It controls the pull-in and hold phases by presetting the appropriate voltages and currents. The power seen by the solenoid is independent of the power supply, temperature or other influences. Furthermore, the power consumption is limited to the strict minimum even in the pull-in phase and reduced to the hold current as soon as the plunger has moved. Therefore the same coil can be used over the full power supply voltage range with identical behavior in all conditions. The ADRV1012K is designed for the most demanding power applications. The 25A pull-in and 2A hold capability with up to 120V supply voltage will switch even the biggest solenoids or valves. Ordering description XX: input voltage range XX value 01 02 Vcc min [V] 20 38 Vcc max [V] 60 125 ADRV1012KXXYY YY: command voltage range XX value 01 02 Vcc min [V] 10 38 Vcc max [V] 60 125 Electrical Specifications, ADRV1012KXX version Parameter Minimum Maximum unit Power Supply On XX=01 20 60 XX=02 38 125 V Maximum pulse current (<150 ms) 25 A Hold current 0.3 2 A Pull in time Auto-detect ms Pull-in current amplitude for 0.7 A detection Max pull in time 1 1000 ms Start-up time 150 ms Response time to enable 2 ms Enable voltage ON YY=01 10 60 YY=02 20 125 V OFF 0 1.5 Status Error Low impedance No error High impedance Status current 20 ma Reverse voltage protection - 150 V Protection against coil discharge diode Operating temperature range 10 70 C 2 1 Only if the solenoid is used under abnormal conditions. (pressure is too high, solenoid worn out ) 2 A custom version can go down to -40 C 2/6 released on: 01/02/2010

If your application is out of the specifications listed above, do not hesitate to contact Elactis. We can then customize the driver to meet your most demanding needs. Working principle The ADRV1012K manages the current in a monostable solenoid. After the enable pin is set, a pre-determined pull-in voltage (V pull-in ) is put on the coil. Once the solenoid has switched the output is regulated to a pre-set current (I hold ). This value is kept until the Enable is set to 0. The pull-in voltage and hold current are factory programmed to customer request. It is also possible to change these values with an external programming kit. During operation the ADRV1012K constantly monitors the solenoid. The status is reported on an optocoupled current output alarm pin. This output can drive for example a 20mA relay. An LED helps visualize the output state. The meaning of the status is summarized in the table below: Figure 1: Typical current pattern using the ADRV1012K LED Status and output Continuous Green / Status high LED turned off / Status low LED turned off / Status low; Coil switched OFF Meaning Solenoid driver is operating correctly Solenoid did not turn-on within timeout or Coil is not present or Voltage is too low Short-cut Applications The driver is particularly well adapted: - To reduce the switching time (ON and OFF) - To enable the usage of the same solenoid or valve at different voltage ranges - To save energy and reduce heating. - To reduce the coil size. Reducing switching time is very important in accurate sorting and dosing applications. Large coils producing big forces can be energized very fast if they are chosen to be very low resistance and combined with the ADRV1012K. The driver will limit the current taken out of the power supply and reduce to the minimum the power consumption and heating. During the turn-off, it contains a special feature allowing a faster switching than without the driver. The driver can be used over a wide variety of voltages. As it supports big currents and voltages, it can be used with a low voltage coil in applications ranging from 24V to 110VDC. We recommend using a 24V coil and setting the Pull-in voltage to the rated value. The driver and the same solenoid will operate with exactly the same characteristics (opening time, closing time, forces and power consumption) over the full operating voltage range (i.e. 38V to 125V) The driver can deliver 20A during the pull-in phase at up to 110VDC nominal voltages. This means that solenoids up to 2KW can be driven by the board. The power saving is very well optimized. Due to the current regulated output, the power can be reduced close to the minimum value before the solenoid turns-off. Temperature and voltage changes are compensated by the driver. The power is also limited during the pull in phase on one side by the Pull-in voltage and on the other by the automatic plunger detection. The first ensures that even with changing power supply voltages the pull-in current will not change. This enables savings on the power requirements of the power supply. The switching detection saves on the current as it will never rise to the nominal value. Heating is therefore minimized both during the pull-in and the hold phase. This is very important for high frequency operations. Smaller coils can be used saving significant weight and copper. Coils that otherwise would overheat can be used in combination with the driver. Its optimized power saving and high current capability allows the use of much smaller solenoids than before to develop the same forces. 3/6 released on: 01/02/2010

Recommendation for design The driver is a high frequency PWM signal generator. Care has to be taken to minimize electromagnetic emissions. The driver must be put as close as possible to your coil and with twisted wires. Power supply cables should also be kept as short as possible and be twisted. The total magnetic power seen by the circuit should be kept smaller than 300mW. To compute this power, the hold current (which is the current at the moment of the switch-off), the coil inductance and the frequency of switching must be known. The following formula is then used: 1 2 P mag LI f 2 For instance, if we have a coil with a 50mH inductance, 2A hold, the max switching frequency will be: 2 Pmag max 2 0.3 f max 3Hz 2 3 2 LI 50 10 2 Mechanical drawing This connector is a male, 5mm pitch, 12 poles; The female connector is delivered with the device 106 mm The device can be directly put on a horizontal plane, or on a DIN rail (there are fixing feet for mounting on DIN 35 rails on the bottom of the enclosure) Wiring 1) Vsupply 2) Earth 3) GND 4) Coil 5) Coil+ 6) Supply out 7) Connect to pin 8* 8) Enable 9) Supply for Status 10) GND for Enable 11) NC 12) Status 101.7 mm *: This pin 7 has to be connected to pin 8 to operate the solenoid; this is done directly on the female connector V supply and GND must be connected to your power supply. The Earth pin has to be fixed to your grounding connection for operation above 48V. Coil and Coil + are the outputs to the solenoid coil. V supply out is an auxiliary output which is internally connected to V supply. It can be used to replace the power supply for the Enable and Output pins. In that case there is no galvanic isolation. Supply for Status must be connected to the power supply of the command (for example the 24V of the PLC or to Vsupply Out) 4/6 released on: 01/02/2010

External trigger The driver can be driven by an external source such as a PLC or a relay. Switching the Enable (Pin 8) will switch the solenoid on or off. The output can be connected to an alarm. In case if the Enable is activated using the same power supply, Supply for Status (Pin 9) can be connected to Power supply out (Pin 6). Two wire operation To use the device in two wire mode (ON/OFF by switching on or off the power supply) connect as described on the schematics above. This mode is only recommended for slow operation as there is a 150ms delay to start the ADRV1012K driver. RS232 interface An optional RS232 interface can be used to program various parameters by the user. These parameters are the following: - Pull-in voltage - Hold current 5/6 released on: 01/02/2010

History records Rev. Change Date 01 Creation 22.07.09 02 Update 28.07.09 03 Include wiring 29.07.09 04 Update 18.09.09 05 Update of the pin7 connections 28.10.09 06 Update of the "Pull-in current amplitude for detection" and added command voltage in the ordering description 01.02.10 6/6 released on: 01/02/2010