Flowrite AP 599 Series

Similar documents
Flowrite TM AP 599 Series 8-inch Pneumatic Valve Actuator

Packing Replacement Kit for Flowrite VF 599 Series Valves

Powers Controls Powertop Two-Way Valves Normally Open

Rebuild/Repack Kits for Flowrite VF 599 Series 2-1/2 to 6-inch Valves

Powers Controls RL 147 Positioning Relay

Powers TM Controls RL 243 SW Switching Relay

Powers Controls 656 Powermite Valve with 3-inch Top Rebuilding

POWERS Controls No. 4 Pneumatic Damper Actuator

Powers Controls No. 6 Damper Actuators Tandem Mounting

Flowrite 599 Series High Pressure Close-Off 2-Way Valves, 2-1/2 to 6-Inch, Flanged Iron Body, ANSI Classes 125 & 250

Flowrite EA 599 Series SQX Electronic Valve Actuator 24 Vac, 3-Position Control

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac 3-Position (Floating) Control

Powers TM Controls SW 134 Pressure Electric Switch (Adjustable Differential)

Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type)

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

599 Series Zone Valve Bodies:

POWERS TM CONTROLS LC Pneumatic Damper Actuator

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Powers Controls No. 6 Pneumatic Damper Actuator

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Pressure Independent Control Series

Flowrite 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Powers Controls Powermite Two-Way Flared Valves Normally Open/Normally Closed

Flowrite EA 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Powers Controls No. 4 Pneumatic Damper Actuator

SKD U Electronic Valve Actuator

SKD U Electronic Valve Actuator

Pressure Independent Control Series

Powers Controls Maximum Thrust Ratings of Pneumatic Damper Actuators

Flowrite VF 599 Series Three-Way Valves 1/2 to 2-inch Bronze Body

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

Flowrite 599 Series SKB/C Electronic Valve Actuator 24 Vac, 3-Position (Floating) Control

Flowrite 599 Series Two-Way Valves 1/2 to 2-inch Bronze Body

POWERS TM CONTROLS SW 786 Selector Switch

599 Series Ball Valve and Actuator Assemblies Selection

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

VE VVG Series Electronic Two-way Valves Normally Closed

Powermite 599 Series MT Series Terminal Unit Two-way Valves

SAX Electronic Valve Actuator

Technical Instructions Flowrite 599 Series SKD6xU Electronic Valve Actuators 24 Vac Proportional Control Description Features Application

SKD62UA Series Electronic Valve Actuator, Advanced Features

Powermite 599 Series MT Series Terminal Unit Three-way Valves

599 Series 6-Way Ball Valves

Accessories/Kits Ball Valve Bracket Kit (includes bracket, mounting screws, shaft and handle)

599 Series 2-Way Ball Valves

Flowrite EA 599 Series SKB/C/D 62UA Series Electronic Valve Actuator 24 Vac Proportional Control Advanced Features

599 Series Ball Valve and Actuator Assemblies Selection

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

Pressure Independent Control Series 2-Way Valves and Electronic Valve Actuators

Powers TM Controls EA 338 Electronic Actuator

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

SED2 Variable Frequency Drives

Flowrite 599 Series. Technical Bulletin. 1/2 to 2-Inch Valve (2-Way & 3-Way) and Actuator Assembly Selection. Document No.

Laboratory Exhaust Air Terminal

SAX Electronic Valve Actuator

Powermite 599 MT Series SQS Electronic Valve Actuator, 24 Vac, Floating Control (3-position)

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Floating Control

Powermite 599 Series MZ Series SSB Electronic Valve Actuator 24 Vac Proportional Control

599 Series Zone Valve Bodies:

SED2 Variable Frequency Drive Electronic Bypass (E-Bypass) Options

Powers TM Controls SW 141 Differential Static Airflow Switches

Ball Valve Bracket Kit

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Powermite 599 MT Series Terminal Unit Valve and Actuator Assembly Selection

599 Series 2-Way Ball Valves

Powermite 599 MT Series Terminal Unit Valve and Actuator Assembly Selection

599 Series 2-Way Ball Valves

SAV Electronic Valve Actuator

Flowrite 599 Series SAX Electronic Valve Actuator Non-spring Return, 24 Vac, 3-Position Control

MK-6600 Series, MK-6800 Series, and MK-6911

Flowrite Globe. Pneumatic 4-inch Valve Actuator. Valves. Description. Applications. Features D-141.

Technical Instructions Document No EA GQD May 6, OpenAir GQD Series. Spring Return, 20 lb-in (2 Nm), Rotary Electronic Damper Actuators

Powers Controls TT 184 Temperature Transmitters

599 Series 2-Way Ball Valves

VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)

SED2-BT300-XX-C09 Migration Kits. Product Numbers

V-9502 Series Pneumatic Valve Actuator Positioners

Ball Valve Bracket Kit

VVP45 and VXP45 Series Two-port and Three-port Seat Valves ANSI Class 250 Short-stroke Valves

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions

TEC Actuator Package. Product and Part Numbers. Product Description. Installation Instructions Document No October 27, 2010 CAUTION:

POWERS CONTROL RC 195 Multiple Input Receiver- Controller

Technical Instructions. SQV Series Electromotive Valve Actuators. Document No

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

OpenAir GBB/GIB Series Electronic Damper Actuators Non-Spring Return, 24 Vac, Modulating Control

OpenAir Electric Damper Actuators GBB/GIB Series NSR Rotary 24 Vac - Modulating Control

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

Powers TM Controls RL 243 SW Switching Relay

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Proportional Control

Flare Valves 1/2 inch 2-Way and 3-Way

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

TK-6024, TK-6124, TK-8024, TK-8124

599 Series Zone Valves

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

January 2016 GLOBE VALVES MIXING & DIVERTING SERIES 8600 MODEL Previously manufactured by Dezurik and Honeywell

Transcription:

AP 599-2 Flowrite AP 599 Series 12-inch Pneumatic Valve Actuator Description The Flowrite AP 599 Series 12-inch pneumatic valve actuator is designed for use with the Flowrite VF 599 Series valves. This actuator is available with two stem strokes. Features Completely enclosed actuator housing protects the diaphragm, springs, and start point adjuster. Product Numbers Positioning relay is available factory-mounted or as an accessory. Start point of the actuator spring is adjustable. This allows the valve to be sequenced. Easy installation. Product Number Table 1. Actuator Type Actuator Code 599-01010 3/4" (20 mm) stroke Pneumatic 279 Pneumatic with Factory Mounted Positioning Relay 285 599-01000 1-1/2" (40 mm) stroke Pneumatic 281 Pneumatic with Factory Mounted Positioning Relay 287

Flowrite AP 599 Series 12-inch Pneumatic Valve Actuator Warning/Caution Notations WARNING Personal injury/loss of life may occur if you not perform a procedure as specified. CAUTION Equipment damage, or loss of data may occur if you do not perform a procedure as specified. Page 2

Flowrite AP 599 Series 12-inch Pneumatic Valve Actuator Technical Instructions Specifications Effective diaphragm area 90 inch 2 (580 cm 2 ) Diaphragm material Buna-N Application Nominal spring range Fixed span Adjustable start point Factory setting Nominal stroke Maximum diaphragm pressure Air Connection Medium temperature Ambient operating and storage temperature Mounting location Dimensions Shipping weight 5 psi (34 kpa) 3 to 10 psi (21 to 69 kpa) 3 to 8 psig ( 21 to 55 kpa) NO valves 10 to 15 psig (69 to 103 kpa) NC valves 3/4 inch (20 mm) 1-1/2 inch (40 mm) 35 psi (241 kpa) 1/4-inch NPT 25 to 366 F (-4 to 186 C) 35 to 180 F (2 to 85 C) NEMA 1 (interior only) 17-7/8" H 15-1/8" dia. (454 mm H 384 mm dia.) 53 lb (24 kg) These 12-inch actuators are designed to be used on Flowrite VF 599 Series valves in liquid service and steam service. Operation Accessories Service Kits The control air signal upon the diaphragm causes the valve to modulate whenever the air pressure is within the spring range of the actuator. The actuator springs provide the necessary force to hold the stem in the stem up (direct acting) position. Packing Heater Kit 599-00418 Positioning Relay and Mounting Kit 599-00423 Instructions for mounting are included with the accessory. Spring Clamp (secures 1/4-inch O.D. poly tubing to barb-fitting 531-833 at higher control pressures or elevated temperatures) Retainer Bracket Kit 599-00436 Diaphragm Replacement Kit 599-01070 Stem retainer kit 2-1/2 inch and 3-inch valves 599-10048 4-inch, 5-inch, and 6-inch valves 599-10049 Page 3

Flowrite AP 599 Series 12-inch Pneumatic Valve Actuator Mounting and Installation Allow 12 inches (300 mm) above and 6 inches (150 mm) on each side of the actuator for servicing. For best performance, install the actuator vertically above the valve. The actuator may be installed in any position between vertical and horizontal. Siemens Building Technologies does not recommend installing the actuator below horizontal or upside down. See Figure 1 for acceptable mounting positions. Complete instructions for field mounting the actuator are included with the actuator. The top edge of the stem nut indicates the valve stem position. The 0 marking on the actuator yoke indicates stem up position. The 1 mark indicates stem down position. See Figure 3. PERMISSIBLE NOT PERMISSIBLE Figure 1. Mounting Positions. Page 4

Flowrite AP 599 Series 12-inch Pneumatic Valve Actuator Technical Instructions Table 2. Parts List. See Figure 2. Item Description Q ty Material 1 3/8-16 thread forming screw 16 Plated Steel 2 Upper housing 1 Aluminum 3 Diaphragm 1 Buna-N 4 Piston plate 1 Aluminum 5 Spring 6 Chrome Silicon Steel 6 Anti-spin rod 2 Plated Steel 7 Adjuster retaining ring 1 8 M20 1.5 flat hex jam nut 1 Plated Steel 9 1/4-20 external tooth lock washer 2 Plated Steel 10 1/4-20 2-1/4 hex head cap screw 2 Plated Steel 11 Actuator shaft 1 3/4 (20 mm) stroke Yellow Chromate Plated Steel 1-1/2 (40 mm) stroke Bright Chromate Plated Steel 12 Start point adjuster 1 Brass 13 Spring plate 1 Aluminum 14 Lower housing 1 Aluminum 15 Stem retainer clip 1 Stainless Steel 16 Stem nut 1 Stainless Steel 17 Actuator retainer 1 Aluminum 18 Washer 6 19 #8 Thread forming screw 6 Retainer bracket kit Items 9, 10 and 17 599-00436 Diaphragm replacement kit Items 3, 18, and 19 599-01070 Stem retainer kit Items 15 and 16 For 2-1/2 and 3 inch valves For 4, 5, and 6-inch valves 599-10048 599-10049 Service Diaphragm Replacement Complete instructions are included in the diaphragm replacement kit. WARNING: Relieve spring tension before removing the actuator upper housing. Page 5

Flowrite AP 599 Series 12-inch Pneumatic Valve Actuator Parts of the Actuator Figure 2. Flowrite AP 599 Series 12-inch Pneumatic Valve Actuator. See Table 2. Page 6

Flowrite AP 599 Series 12-inch Pneumatic Valve Actuator Technical Instructions Spring Adjustment With the actuator in an upright position and the stem visible as shown in Figure 3, use a 1-1/16 inch open-end wrench to turn the adjustment screw. Normally Open Valves: To increase the start to close pressure, turn the adjustment screw from right to left. To decrease, turn the adjustment screw from left to right. Normally Closed Valves: To increase the start to open pressure, turn the adjustment screw from right to left. To decrease, turn the adjustment screw from left to right. NOTE: As the line pressure differential across the valve increases, the spring span will increase. Figure 3. Spring Adjustment. Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Flowrite is a registered trademark of Product or company names mentioned herein may be the trademarks of their respective owners. 2009 Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 + 1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com Printed in the U.S.A. Page 7