OPERATOR S MANUAL A

Similar documents
OPERATOR S MANUAL SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

1-1/2" DIAPHRAGM PUMP 1:1 Ratio (metallic) with Cone Checks

OPERATOR S MANUAL

OPERATOR S MANUAL

OPERATOR S MANUAL C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

1 FDA SANITARY DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

1/4" DIAPHRAGM PUMP SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART PD02 P - X X S - X T X

66M170-XXX-C RELEASED: REVISED: (REV. 05) 1-1/2" DIAPHRAGM PUMP

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL SX20X-XXX-XXX-AXXXX INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL SX20X-XXX-XXX-AXXXX

3/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: X X - X X X - C

3/4" DIAPHRAGM PUMP SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART PD07R - X A S - X X X

3" DIAPHRAGM PUMP SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

2" DIAPHRAGM PUMP SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

1-1/2 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

1/2" DIAPHRAGM PUMP SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART PD05 P - A X S - X X X

3/8 DIAPHRAGM PUMP 1:1 RATIO, NON-METALLIC

READ THIS MANUAL CAREFULLY BEFORE INSTALLING,

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART PH15 F - X S P - S X X - X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

1/4" DIAPHRAGM PUMP PUMP DATA. Model PD01X. Model PE01X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART 6662A3-XXX-C 6662X X X X X C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART PH15 F - X S P - S X X - X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

OPERATOR S MANUAL PD20P-X-X PE20P-X-X RELEASED: REVISED: (REV: N) 2 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)

3/8 DIAPHRAGM PUMP 1:1 RATIO, NON-METALLIC

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART PH20F - XSP - S X X - X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

SERVICE KITS PUMP DATA MODEL PD07P. MODEL PE07P Figure 1 INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED:

3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

SERVICE KITS PUMP DATA INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED: XX-XXX-C. Figure 1. RELEASED 13/Nov/ :24:02 GMT

1/2" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

1-1/2 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)

MODEL DESCRIPTION CHART 6661 X X X X X C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

PE30R-XXX-XXX-C RELEASED: REVISED: (REV. 07) 3" DIAPHRAGM PUMP

UV PROCESS SUPPLY, INC. CON-TROL-CURE ½ DIAPHRAGM PUMP INSTRUCTION MANUAL PART # J

1/2" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

1/4 DIAPHRAGM PUMP / 1/2 PORTS 1:1 RATIO (NON-METALLIC)

3 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

PE30X-XXX-XXX-C RELEASED: REVISED: (REV. 05) 3" DIAPHRAGM PUMP

UV PROCESS SUPPLY, INC.

OPERATOR S MANUAL INCLUDING: OPERATION, INSTALLATION & MAINTENANCE

1-1/2" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED:

PUMP DATA. Model PD01X. Model PE01X INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED:

3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

1-1/2 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)

2 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART PP10A - X X X - X X X INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED:

MODEL DESCRIPTION CHART 6661 X X X X X -C INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: SERVICE KITS

2 DIAPHRAGM PUMP 1:1 RATIO(METALLIC)

MODEL DESCRIPTION CHART GENERAL DESCRIPTION INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: SERVICE KITS

SERVICE KITS PUMP DATA MODEL DESCRIPTION CHART 6661 X X XXX-C GENERAL DESCRIPTION INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED:

1/4 Diaphragm Pump 1:1 Ratio, (Non-Metallic)

3 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

1 HIGH PRESSURE DIAPHRAGM PUMP 3:1 RATIO (METALLIC)

1-1/2" DIAPHRAGM PUMP 1:1 RATIO (METALLIC) READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT.

3" DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

3 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

SERVICE KITS PUMP DATA MODEL PD20X MODEL PE20X INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED:

1/2 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)

SERVICE KITS PUMP DATA SD20S-XXX-XXX-BXXX. SD20R-XXX-XXX-BXXX Figure 1 INCLUDING: OPERATION, INSTALLATION AND MAINTENANCE RELEASED:

1-1/2 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

1/2" AIR DRIVEN DIAPHRAGM PUMP

OPERATOR S MANUAL AND SALES AND ENGINEERING DATA

SERVICE KITS REBUILD KIT DESCRIPTION CHART MODEL DESCRIPTION CHART SPECIFICATIONS X X 1 - B X - X X X - B

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

E8 Mini-Matic 3/8" Bolted Plastic Pumps Operating Instructions

1/2 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)

2 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

1-1/2 DIAPHRAGM PUMP 1:1 RATIO(METALLIC)

1-1/2 DIAPHRAGM PUMP 1:1 RATIO (METALLIC)

1/2 Air Operated Diaphragm Pump

2 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)

Air-Operated Double-Diaphragm Pump

1 Air Operated Diaphragm Pump

OPERATION MANUAL.25 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 2 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 50 BOLTED. A JDA Global Company

1 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)

2 DIAPHRAGM PUMP 1:1 RATIO(METALLIC)

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL AIR-OPERATED DOUBLE DIAPHRAGM PUMPS 3 POLYPROPYLENE PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 80. A JDA Global Company

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG25 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

OPERATION MANUAL. ALUMINUM Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS .5 METALLIC PUMP PWR-FLO TM AIR DISTRIBUTION SYSTEM NPF 15

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG40 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14, Rev.

OPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE INCLUDE MANUAL: S-632 GENERAL INFORMATION MANUAL (PN )

OPERATION MANUAL NT50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 7/11 rev. 1

OPERATION MANUAL. ALUMINUM Models DUCTILE Models 316 S.S. Models AIR-OPERATED DOUBLE DIAPHRAGM PUMPS

OPERATION MANUAL. ALUMINUM Models. 316 S.S. Models NTG50 NOMAD TRANS-FLO AIR-OPERATED DOUBLE DIAPHRAGM PUMPS. A JDA Global Company. 1/14 rev.

SAFETY MANUAL READ FIRST!

OPERATOR S MANUAL PD10P-X PE10P-X 1 DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC)

Air Operated Diaphragm Pumps

Instructions Parts List

WARNING CAUTION. CAUTION Do not exceed 120 psig (8.3 bar) air-inlet pressure.

AF0465-XX SERVICE KITS GENERAL DESCRIPTION MODEL DESCRIPTION CHART OPERATING AND SAFETY PRECAUTIONS THIS MANUAL COVERS THE FOLLOWING MODELS

Transcription:

OPERATOR S MANUAL 670144-A INCLUDING: OPERATION, INSTALLATION & MAINTENANCE RELEASED: 12-18-15 1/4" DIAPHRAGM PUMP 1:1 RATIO (NON-METALLIC) (REV: A) 67 0144-A READ THIS MANUAL CAREFULLY BEFORE INSTALLING, OPERATING OR SERVICING THIS EQUIPMENT. It is the responsibility of the employer to place this information in the hands of the operator. Keep for future reference. PUMP DATA Models... 670144-A Pump Type... Non-Metallic Air Operated Double Diaphragm Material... See Parts List Weigh...... 2.86 lbs (1.30 kgs) Maximum Air Inlet Pressure... 125 psig (8.6 bar) Minimum Air Inlet Pressure.... 10 psig (0.69 bar) Maximum Material Inlet Pressure... 10 psig (0.69 bar) Maximum Outlet Pressure.... 125 psig (8.6 bar) Maximum Flow Rate (flooded inlet).... 5.3 gpm (20 lpm) Displacement / Cycle @ 125 psig.... 0.019 gal / 0.072 ltrs Maximum Particle Size... 1/16 dia. (1.6 mm) Maximum Temperature Limits (diaphragm / ball / seat material) Acetal... 10 to 180 F (-12 to 82 C) E.P.R. / EPDM... -60 to 280 F (-51 to 138 C) Kynar PVDF... 10 to 200 F (-12 to 93 C) Hytrel... -20 to 150 F (-29 to 66 C) Neoprene... 0 to 200 F (-18 to 93 C) Nitrile... 10 to 180 F (-12 to 82 C) Polypropylene.... 35 to 175 F (2 to 79 C) Viton... -40 to 350 F (-40 to 177 C) Santoprene... -40 to 225 F (-40 to 107 C) PTFE...................... 40 to 225 F (4 to 107 C) Dimensional Data.... see page 7 Noise Level @ 70 psig, 60 cpm... 62.3 db(a) The pump sound pressure levels published here have been updated to an Equivalent Continuous Sound Level (LA eq ) to meet the intent of ANSI S1.13-2005, CAGI-PNEUROP S5.1. Model 670144-A Figure 1 MODEL DESCRIPTION 670144-A Polypropylene Fluid Section/Center Body Material, NPTF / BSPT / Hydrid Threaded INGERSOLL RAND COMPANY LTD 209 NORTH MAIN STREET BRYAN, OHIO 43506 (800) 495-0276 FAX (800) 892-6276 2015 arozone.com

OPERATING AND SAFETY PRECAUTIONS READ, UNDERSTAND, AND FOLLOW THIS INFORMATION TO AVOID INJURY AND PROPERTY DAMAGE y Obtain Material Safety Data Sheets on all materials EXCESSIVE AIR PRESSURE HAZARDOUS MATERIALS from the supplier for proper handling instructions. STATIC SPARK HAZARDOUS PRESSURE CAUTION Verify the chemical compatibility of the pump wetted parts and the substance being pumped, WARNING EXCESSIVE AIR PRESSURE. Can cause per- flushed or recirculated. Chemical compatibility may sonal injury, pump damage or property damage. change with temperature and concentration of the y Do not exceed the maximum inlet air pressure as chemical(s) within the substances being pumped, stated on the pump model plate. flushed or circulated. For specific fluid compatibility, y Be sure material hoses and other components are able consult the chemical manufacturer. to withstand fluid pressures developed by this pump. CAUTION Maximum temperatures are based Check all hoses for damage or wear. Be certain dispensing device is clean and in proper working condition. significantly reduce maximum safe operating on mechanical stress only. Certain chemicals will WARNING STATIC SPARK. Can cause explosion temperature. Consult the chemical manufacturer for resulting in severe injury or death. Ground pump and chemical compatibility and temperature limits. Refer pumping system. to PUMP DATA on page 1 of this manual. y Sparks can ignite flammable material and vapors. CAUTION Be certain all operators of this equipment y The pumping system and object being sprayed must be have been trained for safe working practices, grounded when it is pumping, flushing, recirculating or spraying flammable materials such as paints, solvents, understand it s limitations, and wear safety goggles / lacquers, etc. or used in a location where surrounding equipment when required. atmosphere is conducive to spontaneous combustion. CAUTION Do not use the pump for the structural Ground the dispensing valve or device, containers, hoses and any object to which material is being pumped. components are properly supported to prevent stress support of the piping system. Be certain the system y Secure pump, connections and all contact points to avoid on the pump parts. vibration and generation of contact or static spark. y Suction and discharge connections should be flexible y Consult local building codes and electrical codes for connections (such as hose), not rigid piped, and should specific grounding requirements. be compatible with the substance being pumped. y After grounding, periodically verify continuity of CAUTION Prevent unnecessary damage to the electrical path to ground. Test with an ohmmeter from pump. Do not allow pump to operate when out of each component (e.g., hoses, pump, clamps, container, spray gun, etc.) to ground to insure continuity. material for long periods of time. Ohmmeter should show 0.1 ohms or less. y Disconnect air line from pump when system sits idle y Submerse the outlet hose end, dispensing valve or for long periods of time. device in the material being dispensed if possible. CAUTION Use only genuine ARO replacement parts to (Avoid free streaming of material being dispensed.) assure compatible pressure rating and longest service life. y Use hoses incorporating a static wire. NOTICE Install the pump in the vertical position. The y Use proper ventilation. pump may not prime properly if the balls do not check by y Keep inflammables away from heat, open flames and sparks. gravity upon start-up. y Keep containers closed when not in use. NOTICE RE-TORQUE ALL FASTENERS BEFORE WARNING Pump exhaust may contain contaminants. OPERATION. Creep of housing and gasket materials may Can cause severe injury. Pipe exhaust away from work cause fasteners to loosen. Re-torque all fasteners to insure area and personnel. against fluid or air leakage. y In the event of a diaphragm rupture, material can be NOTICE Replacement warning labels are available forced out of the air exhaust muffler. upon request. y Pipe the exhaust to a safe remote location when pumping hazardous or inflammable materials. y Use a grounded 1/4 minimum i.d. hose between the WARNING = Hazards or unsafe practices which could result in severe personal injury, pump and the muffler. death or substantial property damage. WARNING HAZARDOUS PRESSURE. Can result in serious injury or property damage. Do not service CAUTION = Hazards or unsafe practices which or clean pump, hoses or dispensing valve while the could result in minor personal injury, system is pressurized. product or property damage. y Disconnect air supply line and relieve pressure from NOTICE = Important installation, operation or the system by opening dispensing valve or device maintenance information. and / or carefully and slowly loosening and removing outlet hose or piping from pump. WARNING HAZARDOUS MATERIALS. Can cause serious injury or property damage. Do not attempt to return a pump to the factory or service center that contains hazardous material. Safe handling practices must comply with local and national laws and safety code requirements. Page 2 of 8

GENERAL DESCRIPTION The ARO diaphragm pump offers high volume delivery even at low air pressures, easy self priming and the ability to pump various viscosity materials. The pump is designed to correspond to the needs of the user by offering a variety of wetted parts configurations to handle almost any application. Air operated double diaphragm pumps utilize a pressure differential in the air chambers to alternately create suction and positive fluid pressure in the fluid chambers. Flat checks insure a positive flow of fluid. Pump cycling will begin as air pressure is applied and it will continue to pump and keep up with the demand. It will build and maintain line pressure and will stop cycling once maximum line pressure is reached (dispensing device closed) and will resume pumping as needed. The Acetal material used in this pump contains stainless steel fibers. It s conductivity allows it to be connected to a suitable ground. A ground screw is provided for this. AIR AND LUBE REQUIREMENTS WARNING EXCESSIVE AIR PRESSURE. Can cause pump damage, personal injury or property damage. y A filter capable of filtering out particles larger than 50 microns should be used on the air supply. In most applications there is no lubrication required other than the O ring lubricant which is applied during assembly or repair. y The pump, when fitted with flex checks, can be rotated 360 to suit the application. It may be mounted upside down or on the wall with no effect on suction lift or operating efficiency. The filter and regulator need to be oriented in a normal vertical direction to function properly. y If lubricated air is present, make sure that it is compatible with the O rings and seals in the air motor section of the pump. OPERATING INSTRUCTIONS y Always flush the pump with a solvent compatible with the material being pumped if the material being pumped is subject to setting up when not in use for a period of time. y Disconnect the air supply from the pump if it is to be inactive for a few hours. y The outlet material volume is governed not only by the air supply, but also by the material supply available at the inlet. The material supply tubing should not be too small or restrictive. Be sure not to use hose which might collapse. MAINTENANCE y This product is not intended to be repairable. However, some service items are available. y Provide a clean work surface to protect sensitive internal moving parts from contamination from dirt and foreign matter during service disassembly and reassembly. y Keep good records of service activity and include the pump in preventive maintenance program. y At the end of its service life, please dispose of pump and contents properly. INSTALLATION y Apply PTFE tape or pipe sealant to threads upon assembly to prevent leakage. y Secure the diaphragm pump legs to a suitable surface to insure against damage by vibration. y When the diaphragm pump is used in a forced-feed (flooded inlet) situation, it is recommended that a Check Valve be installed at the air inlet. Kynar is a registered trademark of the Arkema Inc. Loctite and 242 are registered trademarks of the Henkel Loctite Corporation ARO is a registered trademark of Ingersoll-Rand Company Santoprene is a registered trademark of Monsanto Company, licensed to Advanced Elastomer Systems, L.P. Lubriplate is a registered trademark of Lubriplate Division (Fiske Brothers Refining Company) Page 3 of 8

PARTS LIST / FLUID SECTION COMMON PARTS 1 Rod Assembly (includes seals) 24028284 (1) --- 5 Washer, Diaphragm 23981541 (2) [P] 26 Screw 23981574 (32) [SS] 77 Plate 93264 (2) --- 206 Caution Label (not shown) 93122 (1) --- 207 Warning Label (not shown) 93616-1 (1) --- FLUID CONNECTION 6 Diaphragm Screw 93810-1 (2) [P] 15 Fluid Cap 23981632 (2) [P] MATERIAL CODE [B] = Nitrile [Co] = Copper [D] = Acetal [E] = E.P.R. / EPDM [G] = Nitrile [GP] = Groundable Polypropylene [H] = Hytrel [K] = Kynar PVDF [N] = Neoprene [P] = Polypropylene [Sy] = Syn-Seal [SS] = Stainless Steel [T] = PTFE [U] = Polyurethane [V] = Viton 60 Inlet Manifold 23981673 (1) [P] 61 Outlet Manifold 23981715 (1) [P] 329 Label (not shown) 96361 (1) [P] SEAT OPTION 21 Seat 96580-1 (4) [P] DIAPHRAGM OPTION 7 Diaphragm 93898 (2) [T] 19 O Ring Y327-119 (4) [V] 64 O Ring 93947 (2) [B] BALL OPTION 22 Ball 96481-4 (4) [P] PARTS LIST / AIR MOTOR SECTION AIR SECTION PARTS 101 Center Body 23981392 (1) [P] 107 Valve Block Plug 23981434 (1) [P] 111 Major Valve spool Asm (includes seals) 24028268 (1) [P] 129 Major Baffle 23981475 (1) [P] 132 Gasket 23981525 (1) [B] 135 Valve Block Assembly 24243388 (1) [P] 137 O Ring Y325-17 (1) [P] 167 Pilot Valve Spool Assembly (includes seals) 24028276 (1) [D] 173 O Ring 24243313 (1) [U] 226 Gasket, Muffler 23981533 (1) [SY] Page 4 of 8

6 19 26 6 7 15 64 5 1 21 26 60 61 22 7 26 101 64 (PTFE models only) 77 26 PART LIST / FLUID SECTION TORQUE REQUIREMENTS NOTE: DO NOT OVERTIGHTEN FASTENERS. (26) Screws 51-55 in. lbs (5.8-6.2 Nm). (6) Diaphragm Screw / Washer 60-70 in. lbs (6.8-7.9 Nm). LUBRICATION / SEALANTS Apply Lubriplate FML-2 grease (94276) to all O rings, U cups and mating parts. Apply Loctite 242 to threads. Page 5 of 8

PART LIST/ AIR MOTOR SECTION 167 3 129 26 1 226 107 101 1373 1113 1323 1733 26 1 135 TORQUE REQUIREMENTS NOTE: DO NOT OVERTIGHTEN FASTENERS. (26) Screws 25-28 in.lbs (2.8-3.2 Nm) LUBRICATION / SEALANTS Apply Lubriplate FML-2 grease to all O rings, U cups and mating parts. Apply Loctite 242 to threads. Page 6 of 8

DIMENSIONAL DATA Dimensions shown are for reference only, they are displayed in inches and millimeters (mm). A C D B E R Material Outlet (External THD.) S Material Outlet (Internal THD.) J F L M H G T Material Inlet (Internal THD.) K Q Air Inlet U Material Inlet (External THD.) DIMENSIONS A - 7.2 (182 mm) H - 1.9 (48.6 mm) S - 1/4 NPTF/BSPT/Hybrid B - 3.9 (100.0 mm) J - 2.4 (61 mm) T - 1/4 NPTF/BSPT/Hybrid C - 4.6 (117.0 mm) K - 3.9 (99 mm) U- 3/4-14 NPTF D- 6.8 (173.0 mm) L - 2.1 (53 mm) E- 0.3 (8.8 mm) M - 3.2 (81 mm) F- 6.1 (156 mm) Q - 1/4-18 PTF SAE Short G- 0.8 (20.7 mm) R- 3/4-14 NPTF Page 7 of 8

PN 97999-1766 Page 8 of 8