CONTROLLERS & SPECIAL VALVES

Similar documents
INSTRUMENTATION & CONTROL

Diaphragm : Plastic Metal Globe : Plastic Metal Manifold Pinch Valve

GENERAL PURPOSE. 3 Port 1/8 Pilot Valves Two Hands Safety Valve BC 1/4 Body Ported Valves : Mechanically Operated...

Solenoid Valves. Product Catalogue. Solenoid Valves. (Product Catalogue) Solenoid Valves

Condensed Catalog 2006 North America

Figure 1: WPR2 Dimensions and Hardware

Control Valve Specifications

BERMAD Irrigation. Solenoid Valves S - Series. Water Control Solutions

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

S21 Series. - 1" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

LTX RF LEVEL SENSOR. Instruction Manual

S-Series. Solenoid Valves

S21 Series. - 2" NPT - Brass Body - 2-Way Piloted Diaphragm - Normally Open. Dimensions/Weight

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

REVISION HISTORY REVISION HISTORY

Technical Data Sheet

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

updated 08/2010 SOLENOID VALVES

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Solenoid valve VDHT standard BSP (British Standard Pipe)

digital flow meters BW Digi-Meter F-1000

Hydrovar and Packaged Hydrovar

Remote Process Actuation Control System AirLINE - Rockwell 1734 Point I/O System

Output signal active note. Measuring range rel. pressure. Electrical Data Power supply DC V, ±10%, 1.1 W

Sentronic PLUS 614 Series

Holding. Resistance. Inrush. Watts. Amps. Amps. (ohm)

P2050S-030, 1/2, Electronic Pressure Independent Valve Stainless Steel Ball and Stem, Female NPT Ends

GTV Series High Pressure Control Valves

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

VA-640GSX024P. Overview. Applications. Features & Benefits. Datasheet. Large Globe Valve Actuators

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

NV Direct Coupled Globe Valve Actuator

Installation and Operation Instructions DLP Series

Remote Process Actuation Control System AirLINE WAGO Remote I/Os and Fieldbusses

Valve functions Operating mechanism Valve sizing Electrical parameters Manual overrides

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4" to 1" NPT. Features

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Remote Process Actuation Control System AirLINE - Siemens ET 200S

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

ICO2S - 2/2, 3/2 or 5/2 Exia poppet valves Electromagnetically actuated, solenoid pilot operated

DE- OUT OUT DE- OUT OUT DE- SERIES MODEL E21 2-WAY NORMALLY OPEN CONDUIT HOUSG (700) 235 (0) 1 (3) (1) (700) 235 (0) 1 (3) (1) E21G7XC

Solenoid valve VDHT standard BSP (British Standard Pipe)

EM 101 EM EM EM GENERAL INFORMATION. SPECIFICATIONS MATERIALS Wetted Materials - FLOW RANGE

F-1500 SERIES INSERTION TURBINE FLOW METER

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

INTERNATIONAL METAL ENGINEERING

Control Valve Specifications

SKINNER Intrinsically Safe Series Four-Way

Nessie 2/2 way Solenoid valves for High Pressures and High Temperatures, type VDHT

OEM Pressure Transmitters

Pressure Transmitters

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

LF Series Spring Return Direct Coupled Actuator

WATER & IRRIGATION METERS QUALITY FLOW METERS FOR THE AGRICULTURE AND AQUIFER MANAGEMENT. Quality Engineered Systems

Poppet Valves Series. Keeping the World Flowing

Electronic suction modulating valves type KVS

Hot Tap Insertion Vortex

Solenoid Valves & Accessories. Incorporating Solenoid Valves in. Custom Products. Solenoid Operated. Custom Products

Metal tube variable area flowmeter for gases, liquids and steam

Electrically operated valves Series M-07, 3/2-, 5/2- and 5/3-way G1/ and 1580 Nl/min (1.321 and Cv)

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Assisted lift operated 2/2-way solenoid valves Type EV251B

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

Low Profile Insertion Vortex

Royce Total Suspended Solids Systems. Water & Wastewater

DPS280 / DVS280 Series

F-2700 SERIES INSERTION VORTEX FLOW METER

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

Electronic Globe Valves

Assisted lift operated 2/2-way solenoid valves Type EV250B

BC-VDC A TOTAL SYSTEM FOR YOUR DUST COLLECTOR DWYER INSTRUMENTS, INC. DWYER OFFERS YOU:

FILTRON 1-10 (DC/AC) BERMAD Irrigation

RCM - Direct Reading Flowmeters

Manual pneumatic operated valves for fixed installations, CO2 and inert gases. Series B0430

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

/ 3/ 4/ 5/ 5/3 4 Nominal Ambient Temp. Ranges Series Body Material Normal Temperature Range High Ambient Temp Version 8553 Stainless Steel -4 F to 4 F

Flow switches Series AD/VH

Electronic Pressure Switches

2/2-way assisted lift operated solenoid valve type EV250B

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Solenoid valves, 2/2-way servo-operated type EV220B 6-22

2-Color Display High-Precision Digital Pressure Switch

PRESSURE BENCH OPERATING INSTRUCTIONS

Electronic Pressure Switches

Fluid Cooling Industrial COLW Series

Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes

Low Pressure Sensor. Overview. Specifications. Installation and Operation

S40 Series. - 1/4" NPT - Stainless Steel Body - 2-Way Piloted Piston - Normally Open. Dimensions/Weight

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Electronic Pressure Switch EDS 3000

EZ-View. Flow Meters ISO CERTIFIED 9001

ΑΥΤΟΜΑΤΗ ΣΤΡΑΤΣΩΝΑ ΕΛΕΓΚΤΕΣ

Signet 2551 Magmeter Flow Sensor

Versatile and Powerful

Transcription:

CONTROLLERS & SPECIAL VALVES G75-C 1, 2 & 4 Valve Controllers.... 70 G75-C-1W & 1W+ Window Controller... 72 G75-DP Differential Pressure Switch..................................................................... 74 G75-DFC Filtration Controller Set..... 75 G75-BWM Water Meter Controller... 76 G75-DLS Digital Level Switch... 77 G75-ADP Analog Differential Pressure Sensor 78 GEM-LDO GEM-SOL Long distance operators 79 G75-LDO G75 Long distance operator 81

VALVES G75-C Irrigation controller Size A B C 3/4" 145 110 81 1" 153 110 81 1-1/2" 166 160 127 2" 166 170 127 B C A G75 One Valve G75 Two Valves G75 Four Valves Operating temperature -10º to 60ºC Solenoid Valve Software Options Standard / Certification Various mounting options : Directly on a 28mm diameter solenoid in horizontal or vertical position with adaptor Wall mounting with four screws Accessories provided Powered by single 9V alkaline battery; use best quality to ensure at least one year's autonomous operation. Back-up memory Low battery warning Power saving LCD Battery included Compatible with G75 4Ω latch operator Can operate any valve equipped with 3/4" UNEF solenoid cavity (Richdel type) 24 hours real time clock See 'Programming key features' table Solar panel Charger Accurate clock (low time drift) CE Dust and watertight IP67 and NEMA 4X options Wall mounting Horizontal mounting Vertical mounting Solar panel 70

G75-C Irrigation controller Programming key features One Valve Two Valves Four Valves Once daily, at the same time Up to three starts per day Up to three starts per day Once daily on selected days Starts select Starts select Three starts per day Day select Day select OFF Season adjustment 10% - 200% OFF Season adjustment 10% - 200% OFF Master valve will be opened for each command G75-C - TYPE OF CONTROLLER - VALVE 1 - VALVE 2 - VALVE 3 - VALVE 4 - MASTER VALVE (2) One valve 1 No valve 00 No valve 00 No valve 00 No valve 00 No valve 00 Two valves 2 3/8" BSP 30 3/8" BSP 30 3/8" BSP 30 3/8" BSP 30 3/8" BSP 30 Four valves 4 3/8" NPT 31 3/8" NPT 31 3/8" NPT 31 3/8" NPT 31 3/8" NPT 31 1/2" BSP 40 1/2" BSP 40 1/2" BSP 40 1/2" BSP 40 1/2" BSP 40 1/2" NPT 41 1/2" NPT 41 1/2" NPT 41 1/2" NPT 41 1/2" NPT 41 3/4" BSP 50 3/4" BSP 50 3/4" BSP 50 3/4" BSP 50 3/4" BSP 50 3/4" NPT 51 3/4" NPT 51 3/4" NPT 51 3/4" NPT 51 3/4" NPT 51 1" BSP 60 1" BSP 60 1" BSP 60 1" BSP 60 1" BSP 60 1" NPT 61 1" NPT 61 1" NPT 61 1" NPT 61 1" NPT 61 1-1/2"BSP 70 1-1/2"BSP 70 1-1/2"BSP 70 1-1/2"BSP 70 1-1/2"BSP 70 1-1/2"NPT 71 1-1/2"NPT 71 1-1/2"NPT 71 1-1/2"NPT 71 1-1/2"NPT 71 2" BSP 80 2" BSP 80 2" BSP 80 2" BSP 80 2" BSP 80 2" NPT 81 2" NPT 81 2" NPT 81 2" NPT 81 2" NPT 81 G75-A * G75-A * G75-A * G75-A * G75-A * * G75-A TYPE PORT FUNCTION MANUAL OVERRIDE ORIFICE with flange 1 1/8" BSP 10 2W NC 1 None 0 1.0 1 without flange 2 1/8" NPT 11 3W NC 3 1.2 2 Brass 3 1/4" BSP (1) 20 3W NO 4 1.6 3 1/4" NPT (1) 21 1) Example : G75-C-2-50-60 GEVA 75 Two Valves controller : Valve 1 : 3/4" BSP, Valve 2 : 1" BSP G75-C 2 50 60 2) Example : G75-C-4-50-70-80-00-60 GEVA 75 Four Valves controller : Valve 1 : 3/4" BSP, Valve 2 : 1-1/2"BSP, Valve 3 : 2" BSP, Valve 4 : No Valve, Master Valve : 1" BSP, G75-C 4 50 70 80 00 60 3) Example : G75-C-2-60-G75-A-110102 GEVA 75 Two Valves controller : Valve 1 : 1" BSP, Valve 2 : G75-A with flange, 1/8" BSP, 2W NC, no manual override, 1.2 orifice G75-C 2 60 G75-A 1 10 1 0 2 (1)Brass only (2) For Four Valves controller only * To order controllers manufactured according to your specific requirements, please contact our technical sales department. BACCARA WATER IRRIGATION CATALOG 71

VALVES G75-C-1W & 1W + Irrigation window controller 66 71 106 G75 Window G75 Window + 21 39 Irrigation cycles within a defined time frame Operating temperature -10º to 60ºC Solenoid Valve Software Options Standard / Certification Various mounting options : Directly on a 28mm diameter solenoid in horizontal or vertical position with adaptor Wall mounting with four screws Accessories provided Powered by single 9V alkaline battery; use best quality to ensure at least one year's autonomous operation. Back-up memory Low battery warning Power saving LCD Battery included Both Window and Window + controllers have identical programming. Window : compatible with G75 4Ω latch operator Window + : has a stronger output to operate G80 latch and GEM-SOL 'IL' latch coils Window : can operate any valve equipped with 3/4" UNEF solenoid cavity (Richdel type) Window + : only with Baccara latch valve 24 hours real time clock See 'Programming key features' table Solar panel Charger Accurate clock (low time drift) CE Dust and watertight IP67 and NEMA 4X options Wall mounting Horizontal mounting Vertical mounting Solar panel 72

G75-C-1W & 1W + Irrigation window controller Programming key features Set start and end hours Set On time (1 second to 12 hours) Set Off time (1 min to 12 hours) Day select OFF : G75 Window G75-C-1W - VALVE No valve 00 3/8" BSP 30 3/8" NPT 31 1/2" BSP 40 1/2" NPT 41 3/4" BSP 50 3/4" NPT 51 1" BSP 60 1" NPT 61 1-1/2"BSP 70 1-1/2"NPT 71 2" BSP 80 2" NPT 81 G75-A * * This controller will only operate with G75 operators * G75-A TYPE PORT FUNCTION Example : G75-C-1W-50 GEVA 75 Window controller with 3/4" BSP valve. MANUAL OVERRIDE ORIFICE with flange 1 1/8" BSP 10 2W NC 1 None 0 1.0 1 without flange 2 1/8" NPT 11 3W NC 3 1.2 2 Brass 3 1/4" BSP (1) 20 3W NO 4 1.6 3 1/4" NPT (1) 21 G75-C 1W 50 (1)Brass only : G75 Window + G75-C-1W + - VALVE Refer to section of GEM-SOL valves. Consult with us to discuss your specific requirements. Example : G75-C-1W + -GEM-A-21045N0 GEVA 75 Window + controller with : GEM-A valve, brass, 1/8" BSP, 3W NO, 2.4 orifice, NBR, no manual override. G75-C-1W + GEM-A 2 10 4 5 N 0 * To order controllers manufactured according to your specific requirements, please contact our technical sales department. BACCARA WATER IRRIGATION CATALOG 73

VALVES G75-DP Baccara Differential Pressure Gauge Switch 89.5 1 /8 BSP / NPT TYP X 2 "L" Optional Bracket 41 M 5 T Y PX 2 ø 6 0 ø 5 7. 7 4 3 Reads and reacts to pressure differential between two reading points Suitable to work with both media - air and liquid Main applications : filters backwash, pumps control, pressure control 25. 8 "H" 58.8 (60) Programming key features Mechanical Operating temperature : -10ºC to 60ºC Outdoor UV protection Front panel cover protection "H" proof pressure : 14 bar (203 PSI) "H" pressure must be "L" pressure. Manual operation PSI or bar display Time interval between pressure measurements Software Power supply : 6-24V DC or 12-24V AC RED + BLK power supply GRN / WHT N.O contact Low power detect Dry contact (N.O) 0.5A at 24V AC Internal memory to retain "set-up data" at power down. 2" (52mm) diameter 2ft (60cm) 4 wires cable Pressure ports 1/8" BSP/NPT (male) High pressure port is marked by the letter "H" on the housing Connect high pressure before low pressure Disconnect low pressure before high pressure See 'Programming key features' table Contact closed time Time interval between contact closure Zero calibration G75-DP - TYPE ACCESSORIES Stand alone 1 bracket Latch solenoid driver B D Display The LCD display : DIF : measured differential pressure SET : pressure differential trigger setting ON : displayed when the switch contacts are closed Display resolution : 1 PSI in the range 0-99 psi 0.1 bar in the range 0.0-7 bar. Example : G75-DP-1BD Baccara Differential Pressure Gauge Switch, stand alone with mounting bracket and latch solenoid driver. G75-DP 1 B D Dust and watertight IP66 * To order special valves manufactured according to your specific requirements, please contact our technical sales department. 74

VALVES G75-DFC Baccara Filtration Controller Set (DFC) Filtration backwash controller 1-3 stations Backwash by DP or time interval The assembly includes controller and differential pressure sensor Programming key features Controller Set Mechanical Supplied with one DFC controller and one analog sensor Operating temperature : -10ºC to 60ºC Outdoor UV protection Front panel cover protection "H" proof pressure : 14 bar (203 PSI) "H" pressure must be "L" pressure. Manual operation Valve ON time Maximum time interval between washes Valve selection AC and DC units are powered by single 9V alkaline battery; use best quality to ensure at least one year's autonomous operation. AC unit - 24 V AC Back-up memory Low battery warning Power saving LCD Pressure ports 1/8" BSP/NPT (male) High pressure port is marked by the letter "H" on the housing Connect high pressure before low pressure Disconnect low pressure before high pressure Controller : Directly on a 28mm diameter solenoid in horizontal or vertical position with adaptor Wall mounting with four screws Accessories provided Sensor : 2" (52 mm diameter) * G75-A G75-DFC - TYPE OF CONTROLLER - POWER One valve 1 AC 24V (black cover) 1 Two valves 2 DC (grey cover) 2 Three valves 4 G75-A * TYPE PORT FUNCTION MANUAL OVERRIDE ORIFICE with flange 1 1/8" BSP 10 3W NC 3 None 0 1.0 1 without flange 2 1/8" NPT 11 3W NO 4 1.2 2 Brass 3 1/4" BSP (1) 20 1.6 3 1/4" NPT (1) 21 Software Solenoid Options Standard protection class See 'Programming key features' table DC : compatible with G75 4Ω operator AC : compatible with G75 24V AC operator Option to change default factory settings Dust and watertight IP66 1) Example : G75-DFC-2-1-G75-A-110402 GEVA 75 DFC, Two valves controller, AC 24V Valves : G75-A with flange, 1/8" BSP, 3W NO, no manual override, 1.2 orifice G75-DFC 2 1 G75-A 1 10 4 0 2 (1)Brass only * To order controllers manufactured according to your specific requirements, please contact our technical sales department. BACCARA WATER IRRIGATION CATALOG 75

VALVES G75-BWM Baccara Water Meter Controller 66 71 106 21 39 Single station water volume controller Connected to a water meter with pulse outlet Opens at a set time and closes when required water volume has been reached Operating temperature -10º to 60ºC Powered by single 9V alkaline battery; use best quality to ensure at least one year's autonomous operation. Back-up memory Low battery warning Power saving LCD Battery included Various mounting options : Directly on a 28mm diameter solenoid in horizontal or vertical position with adaptor Wall mounting with four screws Accessories provided Solenoid Compatible with G75 4Ω latch operator Measurement units per pulse 100 liters 1m 3 10m 3 100 gallons 1000 gallons 24 hours real time clock Software See 'Programming key features' table Options Solar panel, charger Dust and watertight IP67 and NEMA 4X G75-BWM - VALVE No valve 00 3/8" BSP 30 3/8" NPT 31 1/2" BSP 40 1/2" NPT 41 3/4" BSP 50 3/4" NPT 51 1" BSP 60 1" NPT 61 1-1/2"BSP 70 1-1/2"NPT 71 2" BSP 80 2" NPT 81 G75-A * * G75-A TYPE PORT FUNCTION MANUAL OVERRIDE ORIFICE with flange 1 1/8" BSP 10 2W NC 1 None 0 1.0 1 without flange 2 1/8" NPT 11 3W NC 3 1.2 2 Brass 3 1/4" BSP (1) 20 3W NO 4 1.6 3 1/4" NPT (1) 21 1) Example : G75-BWM-G75-A-110102 G75-A with flange, 1/8" BSP, 2W NC, no manual override, 1.2 orifice G75-BWM G75-A 1 10 1 0 2 Programming key features Set start time Set required water volume Day select OFF * To order controllers manufactured according to your specific requirements, please contact our technical sales department. 76

VALVES G75-DLS Digital Level Switch 89.5 1 /8 BSP / NPT TYP X 2 4 3 ø 6 0 ø 5 7. 7 "L" Optional Bracket 41 25. 8 M 5 T Y PX 2 58.8 "H" (60) Measuring level of two set points : top and bottom Gives a signal to pump or valve Dry installation - no elements inside the tank Main applications : filling or draining of water reservoir and tanks Programming key features Mechanical Operating temperature : -10ºC to 60ºC Outdoor UV protection Front panel cover protection Manual operation Time interval between level measurements function Software Display Power supply : 6-24V DC or 12-24V AC RED + BLK power supply GRN / WHT N.O contact Low power detect Dry contact (N.O) 0.5A at 24V AC Internal memory to retain "set-up data" at power down. 2" (52mm) diameter 2ft (60cm) 4 wires cable Pressure ports 1/8" BSP/NPT (male) High pressure port is marked by the letter "H" on the housing Connect the water tank to the "H" port only See 'Programming key features' table The LCD display shows the water level above the DLS mounting place "ON" is displayed when the switch contacts are closed Display resolution : 10 cm in a range of 0.0-70.0m 0.01 bar in the range 0.0-7 bar Function : "SET" for fill "RESET" for empty Zero calibration G75-DLS - TYPE ACCESSORIES Stand alone 1 bracket Latch solenoid driver Example : G75-DLS-1BD Digital Level Switch, stand alone, with mounting bracket and latch solenoid driver. G75-DLS 1 B D B D Dust and watertight IP66 * To order special valves manufactured according to your specific requirements, please contact our technical sales department. BACCARA WATER IRRIGATION CATALOG 77

VALVES G75-ADP Baccara Analog Differential Pressure Sensor 65.7 1/8 BSP / NPT TYPx2 L Optional Bracket 70 A R 35 1.5 41 66 Ø 6.5 ±0.1 TYP x2 Ø 52 ±0.1 25.8 H M 5 TYPx2 10 Ø 60 Differential pressure to current transducer Suitable to work with both media - air and liquid Main application : analog sensor for filters backwash A 45 Mechanical Operating temperature : 0ºC to 60ºC Outdoor UV protection Measuring pressure range : 0-7 bar (0-101.5 PSI) "H" proof pressure : 14 bar (203 PSI) "H" pressure must be "L" pressure Power supply : 5V DC RED : (+) 5V BLACK : (-)5V ORANGE : analog output Analog output value : 0.2V to 4.7V, [V out = (0.006429xKpa+0.2)± Error] Ouput accuracy : 2.5% of full scale 2" (52mm) diameter 2ft (60cm) 3 wires cable Pressure ports 1/8" BSP/NPT (male) High pressure port is marked by the letter "H" on the housing Connect high pressure before low pressure Disconnect low pressure before high pressure IP66 G75-ADP - TYPE MOUNTING BRACKET Stand alone 1 without 0 with 1 Example : G75-ADP-10 Baccara Analog Differential Pressure Sensor, stand alone, without mounting bracket. G75-ADP - 1 0 * To order controllers manufactured according to your specific requirements, please contact our technical sales department. 78

VALVES GEM-LDO Long distance operator 2 Way, 3 Way NC, NO 39 91.2 Assembled with GEM-S solenoid 86 91.5 LDO unit GEM-SOL VALVE Assembled with GEM-A solenoid A small section conductor can be used at a distance of up to 5 kms Function Current 2 Way, 3 Way NC, NO Holding 4mA Refer to working pressure definitions of the Pressure range valve that the GEM-LDO is assembled on, with DC10W/AC8W Power 12V : 50mW 24V : 100mW Red/Black - power supply Green/Black - coil Connection Lead wire length - 28cm PVC coated AWG 18 UL 1007 Ambient temp -10ºC to 70ºC Operation Only with GEM-BL-LDO coil and Baccara valve Cost saving wiring for remote solenoid operation Applications Power saving and heat prevention on continuous energized solenoid Voltage Voltage and power consumption - see table IP67 (LDO only) Voltage AC (W) 50 Hz 60 Hz Distance (km) DC(W) V 0.3 0.3 0.3 12 24 Conduit section (mm 2 ) Delay Time (sec) On 12/24 0 3 1 12 5 0.5 12 1 24 5 0.5 8 1 * Max conduit resistance 390Ω at nominal voltage Voltage & Power Consumption Available options Off GEM-LDO - VOLTAGE - Please refer to the "How to Order" definitions of the assembled GEM-SOL valve. 24 VAC & 12-24 VDC 9 Example : GEM-LDO-9-GEM-A-21035N0 GEM-LDO is attached to a GEM-SOL direct operated, brass 1/8"BSP, 3W NC, 2.4 orifice, NBR, no manual override. GEM-LDO 9 GEM-A 2 10 3 5 N 0 * To order special valves manufactured according to your specific requirements, please contact our technical sales department. BACCARA WATER IRRIGATION CATALOG 79

VALVES LDOS Long distance operating solenoid 2xM5X0.8 DEEP 8 22 22 68 90.8 Assembled with GEM-S solenoid 27 82 GEM-SOL VALVE 32 LDOS unit Assembled with GEM-A solenoid A small section conductor can be used at a distance of up to 5 kms. Pressure (bar) table Current 24V AC : Holding 15mA 12V DC : Holding 4mA Pressure range See table Power 24V AC : 0.3W 12V DC : 0.05W Delay time See table Connection DIN 43650 Connecting box Ambient temp -10ºC to 70ºC Operation Only with a Baccara valve Cost saving wiring for remote solenoid Applications operation Power saving and heat prevention on continuous energized solenoid Voltage Voltage and power consumption - see table +10% -10% of nominal IP65 with connector * Option : IP67, IP68 Function Orifice (mm) Pressure 3W NC 3W NO Delay time (sec) at a nominal voltage 4-5 1.6 16 2.0 10 2.4 8 1.6 16 2.0 12 2.4 8 Distance (Km) Conduit Section (mm) 2.4 0.5 4.8 1.0 7.5 1.5 LDOS - VOLTAGE - 24V AC 1 12V DC 2 Please refer to the "" definitions of the assembled GEM-SOL valve Example : LDOS-1-GEM-A-21035N0 LDOS 24V AC is attached to a GEM-SOL direct operated, brass, 1/8"BSP, 3W NC, 2.4 orifice, NBR, no manual override. Voltage & Power Consumption 50 Hz AC (W) 60 Hz DC (W) V 0.3 0.3 0.3 12 24 Available options LDOS 1 GEM-A 2 10 3 5 N 0 * To order special valves manufactured according to your specific requirements, please contact our technical sales department. 80

VALVES G75-LDO Long distance operator 2 Way, 3 Way NC, NO 79 87 83 50.5 38.5 63.2 94 50 LDO unit assembled with G75-A operator and solenoid 2W 3W A small section conductor can be used at a distance of up to 5 kms Function Current Pressure range Power Connection 2 Way, 3 Way NC, NO Holding 4mA Ambient temp -10ºC to 60ºC Solenoid Valve Applications Voltage G75-LDO - VOLTAGE - Refer to G75 Latch operator 12V : 50mW 24V : 100mW Red/Black - power supply Green/Black - coil Compatible with G75 4Ω latch operator Can operate any valve equipped with 3/4" UNEF solenoid cavity (Richdel type). Cost saving wiring for remote solenoid operation Power saving and heat prevention on continuous energized solenoid Voltage and power consumption - see table IP67 (LDO only) Please refer to the "How to Order" definitions of the assembled G75 valve. Voltage Voltage & Power Consumption AC (W) 50 Hz Distance (km) 60 Hz DC(W) V 0.3 0.3 0.3 12 24 Conduit section (mm 2 ) Delay time (sec) On 12/24 0 0.5 3 1 12 5 0.5 12 1 24 5 0.5 8 1 Max conduit resistance 390Ω at nominal voltage Available options Off 24 VAC & 12-24 VDC 9 Example : G75-LDO-9-G75-A-110320-1 G75-LDO 24V AC is attached to a G75-A with flange, 1/8" BSP, 3W NC 1.2 orifice, no manual override, 24V AC coil, two wires G75-LDO 9 G75-A 1 10 3 2 0 1 * To order special valves manufactured according to your specific requirements, please contact our technical sales department. BACCARA WATER IRRIGATION CATALOG 81