Smith Meter Truck Meter Packages Specifications

Similar documents
Smith Meter PD Meters 3" Steel Model E3

3" Steel Model E3. We put you first. And keep you ahead.

6" Steel Model G6. Smith Meter Rotary Vane PD Meters. Features. Operating Specifications Maximum Flow Rate. Options

Model G6-S3. Repeatability ±0.02%

Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7

Non Ferrous Aircraft Fueling Meters

Smith Meter PD Meters Meter, PD Series, M16-S3, S5, S6 (1993-Present) Parts List

Counters, Printers, Preset Counters

Flow Conditioners. We put you first. And keep you ahead. FEATURES OPTIONS. Bulletin SS02007 Issue/Rev. 0.9 (10/14)

Genesis Series 2" and 3" Steel Meters

Tools, Mechanical. All or Multiple Products. Parts List. Feeler Gauges. Spiders and Bushings. Feeler Gauge Extension Rod. Cam Setting Bushing

Transmitter, Model UPT

Meter, PD Series, K12-S1, S3, S5, S6 and S7

Densitometers L-Dens 427F Ex Density Sensor Specifications

Model DE-3 Air Release Heads Parts List

Electronic Preset Delivery System Smith Meter AccuLoad III. Vapor Recovery. Vapor Recovery System. Overview

Micro Valve. Quick, Sure Response with Design Adaptability. Features and Benefits. Applications. Dependable Performance SPECIFICATIONS / PARTS LIST

OrificeMaster Specifications

Form No. P Meter, PD Model SD, ASD, SF, or ASF-4, 4R, 4V, or 4RV-NF Parts List

MV Series. Smith Meter Turbine Meters. Features. Operating Specifications SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 2.0 (2/18)

MV Series. We put you first. And keep you ahead. SMITH METER TURBINE METERS FEATURES OPERATING SPECIFICATIONS. Bulletin SS02016 Issue/Rev. 1.

Transmitter, Model UPT

2 PETROLEUM AND LP-GAS TANK TRUCK METERS

PRIME 4 Service. Smith Meter Rotary Vane Meters. Contents

Smith Meter Rotary Vane PD Meters Single and Double Case PD Meters Installation / Operation / Maintenance Manual

2 PETROLEUM AND LP-GAS TANK TRUCK METERS

PRECISION METERS & ACCESSORIES

TYPE MP OSCILLATING PISTON FLOWMETER

Smith Meter AccuLoad IV-QT Hardware Worksheet

25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS

Series M and MA Positive Displacement Flow Meters

Smith Meter AccuLoad III AccuLoad III-S and N4 Hardware Worksheet

Additive Injectors. AccuPlus. Maintenance. The Most Trusted Name In Measurement

9400 Series Oval Flowmeter

Industrial Turbo Meters, Sizes 2" through 6"

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

Industrial Pumping Equipment PileDriver III Series III Air Motor Features

High Accuracy Mechanical Fuel meter FM-100

Temporary Strainers. Applications. Pressures to 3705 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZES

UNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE:

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

Smith PD Rotary Vane Meters F4 PRIME Cover Field Retrofit Procedure Service Bulletin

CASH VALVE SERIES FR BACK PRESSURE VALVES

Your Global Source for Today s Most Popular Solenoid Valves

Technical Data. Series Oval Flowmeter. Model 9400

INDUSTRIAL DYNAMICS CO

LBTC Series Positive Displacement Rotary Vane Flow Meters

IMPORTANT!!!! Read this manual before attempting any installation, wiring or operation.

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

Ductile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A

Ph: (07) Fax: (07) Pump Manual

UNIVERSAL PRODUCT LINE: STEEL EXTERNALS JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

Technical Data B20x. 8 BiRotor, APL. Model B201 [8 ] Model B203 [8 ] Model B204 [8 ] Model B205 [8 ]

Introduction. Installation. Maintenance. Bill of Materials

Accessories. Section Outline

Model DFRP Rotary Actuator

I N S T R U C T I O N M A N U A L

Shuttle Type Switches For Moderate to High Liquid Flow Rates

Models F4-V1, G6-V1 and G6-V3

BM SERIES METERS PRECISION POSITIVE DISPLACEMENT METERS THE LEADER IN ACCURATE, LONG-LIFE, FUEL METERING INDUSTRY LEADING ACCURACY (+/-.

FLOWMETER (SMALL CAPACITY) METER SIZE 80, 81

FRL/AirCare Air Controls & Accessories

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

BARTON Floco/Flotrac Meters, Floco Samplers and Pulse Transmitters

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

Rotary Flow Meter SERVICE MANUAL*

Packaged Pump Sets FOR DIESEL FUEL OIL APPLICATION. Packaged Pump Sets for Diesel/Fuel Oil Application Page 1

EP Series Electro-Pneumatic Preset Valve

MECHANICAL REGISTERS

Smith Meter TM PD Rotary Vane Meters F4-S1/A1-S3/A3 PRIME Upgrade Upgrade and Service

Modulating Water Valves and Bulb Wells

VIKING HG SERIES HELICAL GEAR EXTERNAL GEAR PUMPS

MIS SERIES. Mist Eliminator. Installed differential pressure gauge and optional zero air-loss drain valve. Air or Water Cooled Aftercooler

Technical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B

Flow volume: 2-24 l/min Max differential pressure: 10 bar Applications: Lubrication, circulation and transfer

GREASE CONTROL GUNS GREASE CONTROL GUNS Grease control gun Grease control gun with rigid stem and 3 jaw connector ( ).

Bennett Pump Company

UNIVERSAL PRODUCT LINE: STAINLESS STEEL JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE

MOTOR SPEED PRODUCT LINE: CAST IRON PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE. Section 1442 Page 1442.

Instruction Manual HMP TURBINE FLOWMETER. Anderson Instrument Co. Inc. 156 Auriesville Road Fultonville, NY Fax

VG4000 Series. High-Capacity/High-Closeoff Electric Zone Valves

Versa-Matic. Operating Manual. 3/8" Bolted Plastic Pumps. Polypropylene Kynar

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

197C. Valve Group. Series Farris Engineering Pressure Relief Valves

Underground Tank Applications Installation Guide

INSTRUCTION MANUAL MN7 series

Basket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS

CT Series Flex Tube. Displacer Type Level Controller. Specifications

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

MODELS: 800 Series (Reset, Preset, Ticket Printing) 600 Series (Reset) 157 (Non-Resettable Totalizer)

Industrial Pumping Equipment Air-Operated Diaphragm Pumps

To ensure proper installation, digital pictures with contact information to before startup.

A Series General Purpose Pumps General Purpose Pumps for Pressure Lubrication, Hydraulic Service, Fuel Supply and General Transfer

Suction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS

Rotary Flow Meter SERVICE MANUAL*

Butterfly Valve - Series 200

Model 807C Pump Shown

Transcription:

Issue/Rev. 0.4 (8/12) P Meter Smith Meter Truck Meter Packages Specifications ulletin SS01095 TP (Ticket Printer) LN (Large Numeral ounter) Preset ounter Air Eliminator/ Strainer Faucet P Meter Smith Meter Truck Meter Packages are versatile because of their modular design and arrangement flexibility. Truck meter package options are made by combining various components. These consist of a meter, counter, air eliminator/strainer, faucet, preset counter, and ticket printer. The primary functions of metering product and registering volume are performed by a Rotary Vane Positive isplacement Meter and Large Numeral ounter. Other modular features can be easily added as simple bolt on items to meet customer requirements. The air elimination feature will sense slugs of air approaching the meter and vent them. This will keep the meter packed with fluid, preventing erroneous measurement. A strainer is an integral part of the air eliminator which will remove contaminants from the line. The faucet is a valve that starts and stops flow and can be incorporated with the preset counter to automatically deliver and shut off the delivered batch (one person operation). A ticket printer will provide receipt of the registered quantity delivered. Features A wide range of products from gasoline to kerosene to fuel oils can be metered. ompact, versatile design can be readily fit into nearly all installations. Low pressure drop meter results in low meter slippage and thus superior meter accuracy. Responsive air release and air check prevents metering of air on split compartment deliveries. Simple, rugged calibrator is externally adjusted with a screwdriver and easily sealed to prevent unauthorized tampering. High-capacity, low pressure drop strainer built into the air eliminator with easy accessibility for cleaning. Meter Selection Guide Model Max Flow Max Pressure (GPM) (LPM) (psig) (kpa) See Page T11 100 375 150 1034 3 T20 200 750 150 1035 5 T40 400 1500 75 517 7 The Most Trusted Name In Measurement

Individual omponent escriptions Positive isplacement Meter (P Meter) (2" T11, 3" T20, 4" T40) Smith Meter positive displacement truck meters are rotary vane, single-case, angle-type meters. A singlecase outer housing forms part of the measuring chamber. The angle-type meter has the inlet 90 degrees from the outlet. lades that function as part of an internal rotor extend and retract from the rotor as it turns about a fixed cam. The extended blades isolate and measure exact amounts of volume of product passing through the meter. Neither blades nor rotor contact the stationary walls of the measuring chamber, resulting in low pressure drop and long life. Large Numeral ounter (LN) The counter provides a method of registering the volume delivered. The large numeral display can be cleared (reset) while the smaller display totalizer (non-reset) permanently records the total. A selection of unit designations are available, GALLONS, LITERS, etc. Model 620 (Units and Tenths) 620-1 (Tenths and Hundredths) Right Hand ounter Wheel Large Numeral ounter with Ticket Printer (LN/TP) With the addition of a ticket printer to the counter described above, the accurately measured volume can be recorded on a ticket and presented to the customer. The tamper-proof system seals the ticket into the printer while delivery is being made, also sealing out dirt and weather. The ticket is mechanically printed before it can be removed from the printer. First transaction number Second transaction number Start print number End print number End print number Start print number First transaction number Second transaction number 2600 Accumulative System Ticket Zero Start System Ticket 2600 Accumulative System Ticket delivery output is obtained by subtracting Start Print from Finish Print. Zero Start System Ticket Finish Print number is the actual volume delivered. Two-Stage 5 utton Preset ounter (PRESET)* A push button set-stop counter, along with a set-stop faucet, automatically controls the amount delivered. The batch size is set on the counter and then the faucet handle, linked to the counter, is pulled to start the flow. As the completion of the batch approaches, at a pre-determined and set remaining volume (first trip), the preset counter trips, allowing the faucet to partially close (low flow), practically closing the faucet and slowing the flow of product. As the preset counter, which counts downward from the initially set volume or batch, reaches zero (final trip), the faucet closes completely. Air Eliminator/Strainer (2" T2A, 3" T3A, 4" T4A + ) The air eliminator, located upstream of the meter, allows air to collect and then discharges it to provide accurate liquid registration. As the air collects, an internal float drops, eventually signalling an air vent to open and a butterfly or back-pressure valve to reduce or stop the flow of liquid during the venting. The T2A air eliminator utilizes (depending upon the application) either a separate back-pressure valve or one which is integral with the faucet. For the T3A and T4A, linkage connects the float and a butterfly in the eliminator outlet. As the air is driven out of the vessel, the float rises with the liquid, eventually closing the vent and increasing the flow back to its normal rate. A strainer is part of the air eliminator assembly. A 40 mesh screened basket removes particles in the product. The strainer basket is removable for cleaning. XR2 ack Pressure Valve A separate back pressure valve can be used with the T11 meter/t2a air eliminator combination, or one which is an integral part of MP2S and SP2S faucets. In either case, it slows the product flow to allow the air eliminator to release the trapped air. The piston in this valve is operated by the air present in the T2A eliminator. Once the air has been vented, the piston allows the flow through the meter to return to normal. 2½" Air Sense ack Pressure Valve This optional back pressure valve can be used to enhance air elimination efficiency with T20/T3A pressure systems. Faucet Manual Set Stop MP2S, MPG2-Faucet 2" SP2S, SPG2-Faucet 2" MPG3-Faucet 3" SPG3-Faucet 3" MG4-Faucet 4" SG4-Faucet 4" Faucets start and stop the delivery of product. Manually operated faucets require the handle to be moved to start and stop the flow of product. Faucets with the set-stop linkage connected to the preset counter are manually started but will automatically close in two stages at the end of a batch. Two stage closure consists of slowing the flow rate near the end of the batch and then closing the valve completely as the preset counter counts down to and reaches zero. * See ulletin A01026 PSS/LN/TP Adaptation Guide for details on ounter gearing and options. + To properly operate the T4A air eliminator, compressed air at 40 psig ± 5 psig is required. onsumption is approx. 0.15 std. cu.ft. for a standard delivery. Page 2 SS01095 Issue/Rev. 0.4 (8/12)

T11 Meter Package Typical Range & Linearity for Various Products T11 Meter with Standard learances, ounter, and Ticket Printer Linearity ±0.15% ±0.25% Gasoline 0.7 Product & Viscosity Kerosene/ iesel 2.0 Fuel Oil 10 Units 20-100 10-100 5-100 (GPM) 75-378 38-378 19-378 (L/min) 15-100 7-100 3-100 (GPM) 57-378 26-378 11-378 (L/min) T11 Meter with Low Flow learances, ounter, and Ticket Printer ±0.15% ±0.25% 10-100 5-100 2-100 (GPM) 38-378 19-378 8-378 (L/min) 8-100 4-100 1-100 (GPM) 30-378 15-378 4-378 (L/min) T11 Meter with T2A Air Eliminator, SP2S Faucet, Preset ounter, ounter, and Ticket Printer Model T11 P-Z imensions Inches (mm) For Model T11 P-Z* Operating Specifications Maximum Viscosity: 50 mpa s (250 SSU) Temperature: -20 F to 150 F (-29 to 65 ) Maximum Flow Rate: 100 USGPM (375 L/min) Maximum Pressure: 150 PSIG (1034 kpa) 4.6" (118) Outlet Set Stop Faucet 11.1" (238) Pressure rop (P) T2A Air Eliminator ounter Printer 7.0" (178) Preset ounter 25.0" (635) 8.6" (219) 8.2" (210) 10.8" (275) 9.6" (245) Materials of onstruction Housing Internals Seals Pressure rop orrection for Other Products To determine the pressure drop for other products, multiply the P from the chart by the correction factor shown below. T11 2" Meter ast Iron Iron, Steel,, ronze over O-Ring -N Packing Gland or PTFE 9 Specific Gravity Viscosity orrection Factor Gasoline 0.5 0.7 0.63 Fuel Oil 0.9 10 1.6 Fuel Oil #2 0.9 20 1.9 T2A & T3A Strainer (40 mesh) XR-2 Air ack Pressure Valve MP2S, MPG2, SP2S, SPG2 2" Faucets Iron Flange ast Iron ast Iron Steel, ast Iron, Steel, Steel, ast Iron, Viton 9 Polytetrafluoroethylene (PTFE). Issue/Rev. 0.4 (8/12) SS01095 Page 3

T11 Meter Package Selection Guide Modeling Example: T11 P T Meter Model 1 T11 2" System Flow P Pressure G Gravity Meter Package 8 X Air Eliminator/Strainer, Large Numeral ounter/ Ticket Printer (LN/TP) R Air Eliminator/Strainer, Large Numeral ounter V Air Eliminator/Strainer, Large Numeral ounter/ Ticket Printer, Manual Faucet Arrangement 3 A Standard Meter & LN Registration G Gallons 4 ekaliters 5,6 L Liters 5,7 Elastomers una-n/una-n 1 VV Viton/Viton 2 P Air Eliminator/Strainer, Large Numeral ounter, Manual Faucet Z Air Eliminator/Strainer, Large Numeral ounter/ Ticket Printer, Preset ounter, Set Stop Faucet T Air Eliminator/Strainer, Large Numeral ounter, Preset ounter, Set Stop Faucet Notes: 1 una-n packing gland, una-n accessories. 2 Viton packing gland, Viton accessories. 3 All meter packages will be supplied with arrangement (A) unless otherwise specified. 4 All LN's with ticket printers will be 6600 Series with zero start ticket printer and will register in tenths on the first right hand wheel. 5 ekaliter and Liter LN with ticket printer will have accumulative ticket printer and LN will register in whole units unless otherwise specified. 6 Meter gearing is ekaliter, LN will register in ekaliters. 7 Meter gearing is ekaliter, LN will register in Liters. 8 For Large Numerical ounters and Printer Model esignation, Reference ounter Selection Guide ulletin A01024 onnections: Female NPT threaded end connection. Pressure Rating: Maximum working pressure of all meters and components (except T-40 arrangements) is 150 psig (1,034 kpa) at 100 F (65 ). /Outlet Position Arrangements Air Eliminator and Strainer Meter Valve A (Standard) Meters will be set up as indicated by Arrangement A unless otherwise specified. Page 4 SS01095 Issue/Rev. 0.4 (8/12)

T20 Meter Package Typical Range & Linearity for Various Products T20 Meter with Standard learances, ounter, and Ticket Printer Linearity Product & Viscosity Units Gasoline 0.7 Kerosene/ iesel 2.0 Fuel Oil 10 ±0.15% 40-200 20-200 10-200 (GPM) 151-757 76-757 38-757 (L/min) ±0.25% 30-200 15-200 6-200 (GPM) 114-757 57-757 23-757 (L/min) T20 Meter with Low Flow learances, ounter, and Ticket Printer ±0.15% 20-200 10-200 4-200 (GPM) 76-757 38-757 15-757 (L/min) ±0.25% 15-200 8-200 2-200 (GPM) 57-757 30-757 8-757 (L/min) T20 Meter with T3A Air eliminator, SPG3 Faucet, Preset ounter, ounter, and Ticket Printer Model T20-Z imensions Inches (mm) For Model T20-Z* Operating Specifications Maximum Viscosity: 50 mpa s (250 SSU) Temperature: -20 F to 150 F (-29 to 65 ) 5.5" (140) Maximum Flow Rate: 200 USGPM (750 L/min) 14.5" (368) Maximum Pressure: 150 PSIG (1034 kpa) Pressure rop (P) Outlet Set-Stop Faucet 18.5" (470) 8.9" (219) T3A Air Eliminator ounter Printer Preset ounter 11.3" 8.3" (289) (212) 24.7" (629) 13.8" (362) Pressure rop orrection for Other Products To determine the pressure drop for other products, multiply the P from the chart by the correction factor shown below. Specific Gravity Viscosity orrection Factor Gasoline 0.5 0.7 0.63 Fuel Oil 0.9 10 1.6 Fuel Oil #2 0.9 20 1.9 Materials of onstruction T20 3" Meter T3A Air Eliminator/ Strainer (40 mesh) MPG3 & SPG3 3" Faucets Housing Internals Seals ast Iron with Steel Flange Iron, Steel,, ronze Steel, Steel, Iron, -N Packing Gland or PTFE 9 9 Polytetrafluoroethylene (PTFE). Issue/Rev. 0.4 (8/12) SS01095 Page 5

T20 Meter Package Selection Guide Modeling Example: T20 P T V Meter Model 1 T20 3" System Flow P Pressure G Gravity Meter Package 8 X Air Eliminator/Strainer, Large Numeral ounter/ Ticket Printer (LN/TP) R Air Eliminator/Strainer, Large Numeral ounter V Air Eliminator/Strainer, Large Numeral ounter/ Ticket Printer, Manual Faucet Arrangement 3 A Standard Meter & LN Registration G Gallons 4 ekaliters 5,6 L Liters 5,7 Elastomers una-n/una-n 1 VV Viton/Viton 2 P Air Eliminator/Strainer, Large Numeral ounter, Manual Faucet Z Air Eliminator/Strainer, Large Numeral ounter/ Ticket Printer, Preset ounter, Set Stop Faucet T Air Eliminator/Strainer, Large Numeral ounter, Preset ounter, Set Stop Faucet Notes: 1 una-n packing gland, una-n accessories. 2 Viton packing gland, Viton accessories. 3 All meter packages will be supplied with arrangement (A) unless otherwise specified. 4 All LN s with ticket printers will be 6600 Series with zero start ticket printer and will register in tenths on the first right hand wheel. 5 ekaliter and Liter LN with ticket printer will have accumulative ticket printer and LN will register in whole units unless otherwise specified. 6 Meter gearing is ekaliter, LN will register in ekaliters. 7 Meter gearing is ekaliter, LN will register in Liters. 8 For Large Numerical ounters and Printer Model esignation, Reference ounter Selection Guide ulletin A01024 onnections: Female NPT threaded end connection. Pressure Rating: Maximum working pressure of all meters and components (except T-40 arrangements) is 150 psig (1,034 kpa) at 100 F (65 ). /Outlet Position Arrangements Air Eliminator and Strainer Meter Valve A (Standard) Meters will be set up as indicated by Arrangement A unless otherwise specified. Page 6 SS01095 Issue/Rev. 0.4 (8/12)

T40 Gravity Meter Package Typical Range & Linearity for Various Products T40 Meter with Standard learances, ounter, and Ticket Printer T40 Meter with T4A Air Eliminator, MG4 Faucet, ounter, and Ticket Printer Model T40-V Operating Specifications Maximum Viscosity: 50 mpa s (250 SSU) Temperature: -20 F to 150 F (-29 to 65 ) Maximum Flow Rate: 400 USGPM (1500 L/min) Linearity Product & Viscosity Units Gasoline 0.7 Kerosene/ iesel 2.0 Fuel Oil 10 ±0.15% 80-400 40-400 20-400 (GPM) 303-1514 151-1514 76-1514 (L/min) ±0.25% 60-400 28-400 12-400 (GPM) 227-1514 106-1514 45-1514 (L/min) T40 Meter with Low Flow learances, ounter, and Ticket Printer ±0.15% 40-400 20-400 8-400 (GPM) 151-1514 76-1514 30-1514 (L/min) ±0.25% 32-400 16-400 4-400 (GPM) imensions Inches (mm) For Model T40-Z* 13.69" 17.31" (347.73) (185.67) 121-1514 60-1514 15-1514 (L/min) 29.06" (738.12) 6" 5.94" (152.40) (150.88) Maximum Pressure: 36 PSIG (250 kpa) Pressure rop (P) 23.44" (595.38) Set-Stop Faucet Outlet 40 psi required T4A Air Eliminator ounter Printer 25.60" (650.24) Preset ounter 19.81" (503.17) 8.75" (222.25) 12.78" (324.65) 9.07" (230.38) Pressure rop orrection for Other Products To determine the pressure drop for other products, multiply the P from the chart by the correction factor shown below. Specific Gravity Viscosity orrection Factor Gasoline 0.5 0.7 0.63 Fuel Oil 0.9 10 1.6 Fuel Oil #2 0.9 20 1.9 9 Polytetrafluoroethylene (PTFE). 19.19" (487.43) Materials of onstruction T40 4" Meter T4A Air Eliminator MG4 & SG4 Faucets Housing Internals Seals ast Iron with Steel Strainer (40 mesh) Flange Iron, Steel,, ronze Steel, Steel, Iron, -N Packing Gland or PTFE 9 Issue/Rev. 0.4 (8/12) SS01095 Page 7

T40 Meter Gravity Package Selection Guide Modeling Example: T40 G T V Meter Model 1 T40 4" System Flow G Gravity Meter Package 8 X Air Eliminator/Strainer, Large Numeral ounter/ Ticket Printer (LN/TP) R Air Eliminator/Strainer, Large Numeral ounter V Air Eliminator/Strainer, Large Numeral ounter/ Ticket Printer, Manual Faucet Arrangement 3 A Standard Meter & LN Registration G Gallons 4 ekaliters 5,6 L Liters 5,7 Elastomers una-n/una-n 1 VV Viton/Viton 2 P Air Eliminator/Strainer, Large Numeral ounter, Manual Faucet Z Air Eliminator/Strainer, Large Numeral ounter/ Ticket Printer, Preset ounter, Set Stop Faucet T Air Eliminator/Strainer, Large Numeral ounter, Preset ounter, Set Stop Faucet Notes: 1 una-n packing gland, una-n accessories. 2 Viton packing gland, Viton accessories. 3 All meter packages will be supplied with arrangement (A) unless otherwise specified. 4 All LN s with ticket printers will be 6600 Series with zero start ticket printer and will register in tenths on the first right hand wheel. 5 ekaliter and Liter LN with ticket printer will have accumulative ticket printer and LN will register in whole units unless otherwise specified. 6 Meter gearing is ekaliter, LN will register in ekaliters. 7 Meter gearing is ekaliter, LN will register in Liters. 8 For Large Numerical ounters and Printer Model esignation, Reference ounter Selection Guide ulletin A01024 onnections: Female NPT threaded end connection. Pressure Rating: Maximum working pressure of all meters and components (except T-40 arrangements) is 150 psig (1,034 kpa) at 100 F (65 ). /Outlet Position Arrangements Air Eliminator and Strainer Meter Valve A (Standard) Meters will be set up as indicated by Arrangement A unless otherwise specified. Page 8 SS01095 Issue/Rev. 0.4 (8/12)

Issue/Rev. 0.4 (8/12) SS01095 Page 9

Revisions included in SS01095 Issue/Rev. 0.4 (8/12): orrected table headings. Page 4: Elastomers Modeling ode revised from V to. Editorial hange: 11/13: Seals - material reference changed to PTFE. Headquarters: 500 North Sam Houston Parkway West, Suite 100, Houston, TX 77067 USA Phone: +1 (281) 260 2190 Fax: +1 (281) 260 2191 Operations: Measurement Products and Equipment: Ellerbek, Germany +49 (4101) 3040 Erie, PA USA +1 (814) 898 5000 Integrated Measurement Systems: orpus hristi, TX USA +1 (361) 289 3400 Kongsberg, Norway +47 (32) 286700 The specifications contained herein are subject to change without notice and any user of said specifications should verify from the manufacturer that the specifications are currently in effect. Otherwise, the manufacturer assumes no responsibility for the use of specifications which may have been changed and are no longer in effect. ontact information is subject to change. For the most current contact information, visit our website at www.fmctechnologies.com/measurementsolutions and click on the ontact Us link in the left-hand column. www.fmctechnologies.com/measurementsolutions Printed in U.S.A. 8/12 FM Technologies Measurement Solutions, Inc. All rights reserved. SS01095 Issue/Rev. 0.4 (8/12)