Thermoelectric Cooling System. Model 5473

Similar documents
Integrated Heating System

AUTORANGING RESISTANCE INDICATOR

CALIBRATION TEST FIXTURES

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

30100 Module Installation Guide L

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

15100 Module Installation Guide Mercedes EPA07 w/dpf

20250 Module Installation Guide

CU6703 Module Installation Guide

78-88 G Body Rear Trailing Arm Kit

Installation Instructions

ProAir Heat Exchangers XR20, XR29, XR47 & XR60

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Cummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

HA/HAB Fiberglass Wall Mount Ventilators

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

Installation Instructions

SOLAR DASH CHARGING SYSTEM USER GUIDE

Female Plug. connecting to Fuel Quantity

Chicane Coilover Kit For '70 to '81 Camaro/Firebird

Installation Instructions

Cookshack Pellet Fired Charbroiler Models: CB012 CB024 CB036 CB048

CDS-JOHN BLUE COMPANY

FUME HOOD. Installation and Operations Manual

94-96 Impala SS/ B-Body Rear Coilover Conversion Kit

READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

Aug 24, 2017 ATS AFX Spindle Installation Instructions

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

'64-72 Chevelle/ A Body Rear Coilover Conversion Kit

OPERATOR S MANUAL with Parts List & Warranty. For Model 100SP Topdresser

PMD DRIVER RELOCATION KIT For Chevy 6.5L Diesel Trucks

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

OPERATING INSTRUCTIONS AND PARTS LIST BRIDGE DRIVE GEAR CASE

Installation Instructions

BD Ford 1999½ L Power Stroke CRANKCASE VENTILATION KIT

OPERATING INSTRUCTIONS AND PARTS LIST

GLYCOL SYSTEM MONITOR (GSM)

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

CRANKCASE VENTILATION KIT

DODGE CUMMINS 24V ISB

JDCR2000 Module Installation Guide

5874SS/5874PB/5874PBF/VRK5874/PBA6/ PBA6HPB/PBA7 Valve/Push Button

JD2800 Module Installation Guide

PVI 60KW, PVI 82KW, PVI 95KW

MRC 150/300 USER MANUAL. 1 Laird Technologies

Dec 1, 2017 ATS AFX Spindle Installation Instructions

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

PSX-240 Enclosed Autotransformer Installation Manual

'64-72 Chevelle/ A Body Rear Coilover Conversion Kit

Installation Instructions

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Chicane Coilover Kit For '64 to '72 Chevelle/ A Body. Installation Instructions

Specialty Products. Strainers. Check Valves. Butterfly Valves

TRUCK PRODUCT LINE A DIVISION OF DAKOTA FLUID POWER, INC.

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

Utility Controller Hand Air Operated

Type Flexair Pneumatic Pressure Control Valves

INTERNATIONAL MALLEABLE IRON PIPE FITTINGS & UNIONS

ODY-10-1 rev. B FUEL PRESSURE GAUGE

Model FM2642 Wall Mount. Full Motion Television Wall Mount

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

4-Ton Electric Log Splitter

Operating and Maintenance Instructions

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

SD8/SD9 Straight Dozer Blade

Thermaltake Warranty / Support Information

Series 2100 Operating Instructions

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Inline & 90 Live Swivels Fax:

Feb 22, 2018 '67-69 Camaro & '68-74 Nova Bumpsteer Adjustment Kit

ODY-04-1 or ODY-04-2 rev. B WATER TEMPERATURE GAUGE

Installation Instructions. Application List Dodge 24V PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION

USER S OPERATING AND INSTRUCTION MANUAL

User s Manual for Tennessee Chill Box System P/N CB8000

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Smart Battery Charger GPC-35-MAX GPC-45-MAX GPC-55-MAX GPC-75-MAX GPC-100-MAX. Owner s Manual

FAN-STOP INSTRUCTION MANUAL

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

Price List. Specialty Products / Strainers / Check Valves / Butterfly Valves. Effective July 2, MuellerSteam.com 2018 MUELLER PRICE LIST

AUTOMATION. Operator s Manual. NLS Series. Pneumatic Level Sensors. Rev. A1, 4/07

ODY-19-1 AIR PRESSURE GAUGE

EXT DUCTLESS FUME HOOD

HLY-1111 HEAD TEMPERATURE GAUGE

SOLAR BOLT CHARGING SYSTEM INSTALLATION GUIDE

Rig Master Power by Mobile Thermo Systems Inc.

EXT HEPA/CARBON FUME HOOD

9/8/ ½-2004 Dodge 5.9L Cummins Flow-MAX Lift Pump Retro Kit # ½ L DODGE CUMMINS. Installation Instructions

ODY-01-1 or ODY-01-2 SPEEDOMETER


INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS AIR-COOLED AFTERCOOLER FOR COMPRESSED AIR SYSTEMS MODELS AC-140 thru AC-220 (ALL VOLTAGES)

SELECT/DIRECT DEMO BOX USER GUIDE. INST164 Doc 1.00

Transcription:

Thermoelectric Cooling System Model 5473 1 150W (510 BTU/hr.) 1 200W (680 BTU/hr) 1 300W (1020 BTU/hr) 1 400W (1360 BTU/hr) Operating Manual 7/07/06 www.electrotechsystems.com

Table of Contents 1.0 GENERAL 1 2.0 COOLING SYSTEM SET-UP 2 3.0 INSTALLATION 2 4.0 SPECIFICATIONS AND PERFORMANCE 3 WARRANTY 4

Thermoelectric Cooling Systems Model 5473 150W-400W OPERATING INSTRUCTIONS 1.0 GENERAL The Model 5473 Series of solid state, thermoelectric cooling systems, shown in Figure 1.0-1, utilize the Peltier effect to reduce the temperature of a large heat sink. One or more 110 cfm fans circulate the air within a sealed chamber through the heat sink to continuously reduce the temperature. Very precise temperatures can be maintained with this system using an ETS Model 5100 or 5200 Series Microprocessor Controller. Figure 1.0-1 Series 5473-150W Thermoelectric Cooling systems The standard Model 5473 is the Model 5473-150W with a cooling capacity of 510 BTU/hr (150 Watts/hr). The Models 5473-300W units are available which incorporates 2, 5473-150W with a cooling capacity of 1020 BTU/hr. 5473-200W units and 5473-400W (2-5473-200Ws) to provide higher (up to 1360 BTU/hr) cooling capacities, respectively. 1

These systems are best suited for maintaining precise ambient temperatures inside an enclosed chamber. For an uninsulated, 15 cu. ft. chamber, fabricated from 0.375 (10 mm) acrylic, these coolers can reduce the temperature by 5, 10 and 18 F (3, 5 and 10 C) respectively. Heat load, insulation and chamber size will ultimately determine the level of cooling that can be obtained. 2.0 COOLING SYSTEMS SET-UP 1. All Model 5473 Thermoelectric Cooling Systems operate in the same manner. The Model 5473s use an external DC Power Supply. While the type of Power Supply and location of the Supply does not affect operation, it is noted for maintenance purposes. 2. The Thermoelectric System is an integral part of the chamber that usually protrudes through the rear wall, but also may be installed on top or side. 3. The Thermoelectric Cooler is a solid state heat pump. It is virtually maintenance free, with no filters to change. The only moving parts are the fans. As air inside the chamber is drawn through the interior heat sink by the internal thermoelectric fan (this fan is separate and different form the chamber circulation fans), heat is removed from the air and conducted through the thermoelectric modules to the exterior heat sink. The heat is removed from the exterior heat sink and dissipated into the atmosphere by one or more external fans. DO NOT BLOCK AIRFLOW TO THE REAR OF THE UNIT. The hot air must be allowed to dissipate. Increased hot side temperature = Decreased cooling effect. 3.0 OPERATION 1. Plug the AC Line Cord from the Power Supply into the DECREASE outlet of a Temperature controller. (Thermo-Electric Cooler and Power Supply are mounted and wired in Models 5518 & 5532.) Turn on the DECREASE switch located on the front panel of the Temperature Controller. 2

2. Set the Temperature Controller set-point to a value below the ambient temperature (Refer to Controller Operation in the respective Controller Operating Manual). When the microprocessor tells the Cooler to activate, the red LED on the Microprocessor will light. Inside the chamber, the thermoelectric cooler will begin to cool and the fans will begin moving. 3. The microprocessor will determine the amount of cooling needed to maintain the desired set-point. If less than full Cooling Power is needed the Controller will provide pulses of power to the Heating system to compensate. 4. Refer to the section titled Programming in the Microprocessor Temperature Controller Operating Manual for more information on the Microprocessor programming. 4.0 SPECIFICATIONS AND PERFORMANCE All cooling capacity figures are based on a room ambient temperature of 73 F (23 C). All figures are expressed as a ΔT. ΔT expresses the difference in temperature from room ambient (73 F). Example: 73 F - 63 F = ΔT of 10 F 1. The Model 5473 Thermoelectric Cooler will remove up to 510-1360 BTU/hr (150-400 Watts/hr) from the Chamber. For example: A. In a non-insulated Chamber with an 510 BTU/hr unit ΔT = 10 F (5.5 C). In a non-insulated chamber with a 1360 BTU/hr unit ΔT = 18 F (10 C). B. In a Chamber, using appropriate insulation, the ΔT may be increased an additional 10-15 F (5.5-8.3 C), depending on the thickness and quality of the insulation. Contact ETS for details about insulating the chamber. 7/07/06 3

WARRANTY Electro-Tech Systems, Inc. warrants its equipment, accessories and parts of its manufacture to be and remain free from defects in material and workmanship for a period of one (1) year from date of invoice and will, at the discretion of Seller, either replace or repair without charge, F.O.B. Glenside, similar equipment or a similar part to replace any equipment or part of its manufacture which, within the above stated time, is proved to have been defective at the time it was sold. All equipment claimed defective must be returned properly identified to the Seller (or presented to one of its agents for inspection). This warranty only applies to equipment operated in accordance with Seller's operating instructions. Seller's warranty with respect to those parts of the equipment which are purchased from other manufacturers shall be subject only to that manufacturer's warranty. The Seller's liability hereunder is expressly limited to repairing or replacing any parts of the equipment manufactured by the manufacturer and found to have been defective. The Seller shall not be liable for damage resulting or claimed to result from any cause whatsoever. This warranty becomes null and void should the equipment, or any part thereof, be abused or modified by the customer of if used in any application other than that for which it was intended. This warranty to replace or repair is the only warranty, either expressed or implied or provided by law, and is in lieu of all other warranties and the Seller denies any other promise, guarantee, or warranty with respect to the equipment or accessories and, in particular, as to its or their suitability for the purposes of the buyer or its or their performance, either quantitatively or qualitatively or as to the products which it may produce and the buyer is expected to expressly waive rights to any warranty other than that stated herein. ETS must be notified before any equipment is returned for repair. ETS will issue an RMA (Return Material Authorization) number for return of equipment. Equipment should be shipped prepaid and insured in the original packaging. If the original packaging is not available, the equipment must be packed in a sufficiently large box (or boxes if applicable) of double wall construction with substantial packing around all sides. The RMA number, description of the problem along with the contact name and telephone number must be included in formal paperwork and enclosed with the instrument. Round trip freight and related charges are the owner s responsibility. WARNING WOODEN CRATES MUST NOT BE USED. PACKAGING OF DELICATE INSTRUMENTS IN WOODEN CRATES SUBSTANTIALLY INCREASES THE CONTENT S SUSCEPTIBILITY TO SHOCK DAMAGE. DO NOT PLACE INSTRUMENTS OR ACCESSORIES INSIDE OTHER INSTRUMENTS OR CHAMBERS. ELECTRO-TECH SYSTEMS, INC. WILL NOT ASSUME RESPONSIBILITY FOR ADDITIONAL COST OF REPAIR DUE TO DAMAGE INCURRED DURING SHIPMENT AS A RESULT OF POOR PACKAGING. 4