Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

DESIGN GUIDELINES FANS PAGE 1 of 7

Tubular Centrifugal Fans

Propeller Hooded Roof Fans

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Inline Fans [ 14 ] * UL is optional and must be specified.

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

EcoWatt Products. Advancing Ventilation

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

Twin City Fan & Blower

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

EXHAUST FANS CUD & CUB UPBLAST FANS

Centrifugal Spun Aluminum Products

Centrifugal Upblast Power Roof Ventilators

Industry best 5 year fan housing warranty, 1 year motor warranty

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

SECTION HVAC POWER VENTILATORS

Industry best 5 year fan housing warranty, 1 year motor warranty

Filtered Kitchen Supply Packaged Ventilator

Industry best 5 year fan housing warranty, 1 year motor warranty

Propeller Upblast Roof Fans

MODEL TXB BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Roof & Sidewall Mounted

Centrifugal Utility Fans - SFD/SFB

Tube Axial Inline Fans

Centrifugal Spun Aluminum Products

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Centrifugal Spun Aluminum Products

Centrifugal Ventilators Direct-Drive Upblast Centrifugal Roof & Wall Ventilators

forward curved inline duct blowers

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

SQUARE INLINE CENTRIFUGAL FANS

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Fixed Pitch Vane Axial Fan

Centrifugal Filtered Supply Roof Blowers

Inline and Roof Mounted Fans

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS

Downblast Centrifugal Fans with ECM

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

First Inline fan in the industry to be UL/cUL Listed Power Ventilator for Smoke Control Systems

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH

Direct Gas-Fired Heating

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS

CONSTRUCTION FEATURES AND OPTIONS

High Performance Axial Fans

SECTION CENTRIFUGAL HVAC FANS

Tube Axial Fan Page Specifications & Dimension Data Performance Data

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

SECTION AXIAL HVAC FANS

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2.

Twin City Fan & Blower

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

Advancing Ventilation

Power Roof and Wall Ventilators

Wholesale Ventilation Products

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Twin City Fan & Blower

TUBULAR CENTRIFUGAL INLINE FANS

The Industrial Choice. PROPELLER WALL FANS DIRECT DRIVE & BELT DRIVEN. Models BSDDP / BSBP

FKUB Belt Drive - Centrifugal Up-Blast Fans

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

Square Inline Fans with Multi-Directional Discharge

Belt Drive Centrifugal Roof Exhauster Model PV

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

Centrifugal Roof Downblast Exhaust Fans

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

Twin City Fan & Blower

Fumex. Upblast Roof Exhauster Technical Specifications BULLETIN FX17

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

Restaurant Exhaust Ventilator

Centrifugal Upblast Roof Exhausters, EVU-Series

Mixed Flow Inline Fan, Model MFSI

MIN/MAX PERFORMANCE IN INCHES WG

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Centrifugal Roof Downblast Exhaust Fans

Centrifugal Filtered Supply Fans

Transcription:

XRUB, XRUD, XSEB, XSED, and XRUBS models are listed for electrical (UL/C-UL US 0) File no. E000 and for grease removal (UL/C-UL US ) File no. MH. Accurex, LLC certifies model XRUB, XRUD, XSEB, XSED, and XRUBS fans shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication and Publication and comply with the requirements of the AMCA Certified Ratings Program. * UL is optional and must be specified.

Model Overview When you buy an Accurex roof upblast or sidewall exhaust model, you receive a fan with the industry s best performance and durability for general clean air, high grease and other contaminant applications (as found in food service and fume hood exhaust). Both, roof upblast and sidewall configurations, are specifically designed to discharge air directly away from the mounting surface. All fan sizes are tested in our AMCA accredited laboratory, and all models are licensed to bear the AMCA Sound and Air Performance seal. Accurex subjects these products to extensive life testing, assuring you that the fans will provide many years of reliable performance. You will also receive the following benefits with an Accurex roof upblast and sidewall exhaust fan: Leakproof construction for the entire life of the fan utilizing a one-piece windband that is continuously welded to the curb cap, which traps grease and protects the roof Broadest performance in the industry, up to in. wg (, Pa) and 0,000 cfm (0,0 m /hr) Most advanced motor cooling of any fan in its class UL Listed for electrical and grease removal Model Number Code The Model Number Code is designed to completely identify the fan. The correct code letters must be specified to designate belt or direct drive, and roof or wall mounted configurations. The remainder of the model number is determined by the size and performance. XRUB - 0 XP - Model XRUB - Roof Upblast Belt Drive XRUD - Roof Upblast Direct Drive XSEB - Sidewall Exhaust Belt Drive XSED - Sidewall Exhaust Direct Drive XRUBS - Roof Upblast Belt Drive (Steel) Fan Size 00 0 Wheel Pressure Level HP - High-Pressure Motor HP (Belt Drive only) = = 0 = = = 0 = = 0 = = = Motor RPM (Direct Drive only) A = D = B = E = 0 C = 0 G = 0 XP - Extended High-Pressure (Belt Drive only)

Model Comparison XRUB. XRUD. XSEB. XSED. XRUBS. XRUB - Belt Drive Model XRUB belt drive upblast centrifugal exhaust fans are specifically designed for roof mounted applications. Exhaust air is discharged directly upward, away from the roof surface. Performance capabilities range from 00 to 0,000 cfm ( to 0,0 m /hr) and up to in. wg (, Pa) of static pressure. Maximum continuous operating temperature is 00 F (0 C). XRUD - Direct Drive Model XRUD direct drive upblast centrifugal exhaust fans are specifically designed for roof mounted applications. Exhaust air is discharged upward, away from the roof surface. Performance capabilities range from 0 to,00 cfm ( to, m /hr) and up to in. wg ( Pa) of static pressure. Maximum continuous operating temperature is 00 F (0 C). XSEB - Belt Drive Model XSEB belt drive centrifugal sidewall exhaust fans are ideal for exhausting contaminated air away from a building, where a roof mounted unit cannot be used. Performance capabilities range from 00 to,00 cfm ( to,0 m /hr) and up to. in. wg ( Pa) of static pressure. Maximum continuous operating temperature is 00 F (0 C). XSED - Direct Drive Model XSED direct drive centrifugal sidewall exhaust fans are designed to direct air out and away from buildings. Performance capabilities range from 0 to,00 cfm ( to, m /hr) and up to in. wg ( Pa) of static pressure. Maximum continuous operating temperature is 00 F (0 C). XRUBS - Belt Drive Model XRUBS is used for heavy grease exhaust applications as found in charbroilers, solid fuel cooking and oriental cooking. Sizes, HP,, HP, XP are UL Listed for commercial cooking applications and capable of 00 F (0 C) continuous operation. The entire unit is constructed of heavy-gauge steel and has a centrifugal backward-inclined steel wheel. Unit includes: clean out port, non-stick coated wheel, heat baffle, and a NEMA-R disconnect switch. Performance up to. in. wg (0 Pa) and,00 cfm (, m³/hr).

Standard Construction Features XRUB. XRUD. Wheel An aluminum, backward-inclined, nonoverloading centrifugal wheel is utilized to generate highefficiency and minimal sound. Wheel cones are carefully matched to the venturi for maximum efficiency. Each wheel is statically and dynamically balanced, for long life and quiet operation. Disconnect Switch NEMA- switch is factory mounted and wiring is provided from the motor as standard (other switches are available). All wiring and electrical components comply with the National Electric Codes (NEC) and are either UL/C-UL US Listed or Recognized. Fan Shaft Precisely sized, ground, and polished so the first critical speed is at least % over the maximum operating speed. Close tolerances, where the shaft makes contact with bearings, results in longer bearing life. Bearings 0% factory tested and designed specifically for air handling applications with a minimum L() life in excess of 0,000 hours [L(0) average life of 00,000 hours]. Motor Carefully matched to the fan load and mounted out of the airstream. Motor Cover Aluminum construction. Stainless steel fasteners are attached for easy removal and access to the motor compartment and drive assembly. Stainless Steel Fasteners Allows for easy removal and access to the motor compartment and drive assembly. Motor Cooling Cooling fins located on top of the fan wheel draw outside air through a large breather tube, directly into the motor compartment. Positive motor cooling with fresh air results in maximum motor life. Lifting Points Select models have various lifting points located on the drive frame and bearing plates. Vibration Isolation True vibration isolators contain two independent studs with rubber neoprene to support the drive assembly and wheel for long life and quiet operation. (No steel-on-steel contact) Drive Assembly Belts, pulleys and keys are oversized % of driven horsepower. Machined cast pulleys are adjustable for final system balancing. Belts are static-free and oil-resistant. Windband One-piece, heavy-gauge aluminum, with a rolled bead for extra strength, directs exhaust air away from the mounting surface. Leakproof Construction One-piece windband is continuously welded to the curb cap and drain trough, for leakproof protection on XRUD and XRUB, sizes through 00 and all sizes with UL/C-UL US. Mounting Holes Aluminum curb cap has prepunched mounting holes to ensure correct attachment to the roof. Drain Trough Allows for one-point drainage of water, grease and other residue. (Roof Upblast only) Internal Conduit Chase For easy internal electrical wiring in applications not subject to NFPA. (Not shown) Name Plate Permanent stamped aluminum plate for exact model and serial identification number. (Not shown)

Standard Construction Features XSEB. XSED. Wheel An aluminum, backward-inclined, nonoverloading centrifugal wheel is utilized to generate high-efficiency and minimal sound. Wheel cones are carefully matched to the venturi for maximum efficiency. Each wheel is statically and dynamically balanced, for long life and quiet operation. Disconnect Switch NEMA- switch is factory mounted and wiring is provided from the motor as standard (other switches are available). All wiring and electrical components comply with the National Electric Codes (NEC) and are either UL/C-UL US Listed or Recognized. Fan Shaft Precisely sized, ground, and polished so the first critical speed is at least % over the maximum operating speed. Close tolerances, where the shaft makes contact with bearings, results in longer bearing life. Bearings 0% factory tested and designed specifically for air handling applications with a minimum L() life in excess of 0,000 hours [L(0) average life of 00,000 hours]. Motor Carefully matched to the fan load and mounted out of the airstream. Motor Cover Constructed of aluminum. Attached with stainless steel fasteners for easy removal and access to the motor compartment and drive assembly. Motor Cooling Cooling fins located on top of the fan wheel draw outside air through a large breather tube, directly into the motor compartment. Positive motor cooling with fresh air results in maximum motor life. Vibration Isolation True vibration isolators contain two independent studs with rubber neoprene to support the drive assembly and wheel for long life and quiet operation. (No steel-on-steel contact) Drive Assembly Belts, pulleys and keys are oversized % of driven horsepower. Machined cast pulleys are adjustable for final system balancing. Belts are static-free and oil-resistant. Windband One-piece, heavy-gauge aluminum, with a rolled bead for extra strength, directs exhaust air away from the mounting surface. Mounting Holes Aluminum curb cap has prepunched mounting holes to ensure correct attachment to the roof. Galvanized Birdscreen Rigid wire protects the fan s discharge from birds and small objects. Standard on all Sidewall fans. Galvanized Mounting Plate Allows mounting and sealing to the wall prior to mounting the entire unit. The remainder of the unit is attached to the mounting plate without locating and fastening problems associated with mounting a heavy sidewall unit to a wall. Internal Conduit Chase For easy internal electrical wiring in applications not subject to NFPA. (Not shown) Name Plate Permanent stamped aluminum plate for exact model and serial identification nmber. (Not shown) Stainless Steel Fasteners Allow easy removal and access to the motor compartment and drive assembly. (Not shown)

Standard Construction Features XRUBS. Fan Shaft Is one inch minimum in diameter, precisely sized, ground and polished, so the first critical speed is at least % over the maximum operating speed, which results in longer fan life. Drive Assembly Dual belts, pulleys and keys are oversized % of driven horsepower. Machined cast steel pulleys are adjustable for final system balancing. Belts are static-free and oil-resistant. Bearings Lubricatable cast pillow block and air handling quality extended life. Minimum L() life in excess of 0,000 hours [L(0) average life of 00,000 hours]. True Vibration Isolation Lowers sound levels and reduces vibration, which increases the fans life, since true vibration has no steel-on-steel contact. Clean Out Port Allows the outside of the wheel to be cleaned through a -inch diameter removable plug in the windband. Non-Stick Coated Steel Wheel Heavyweight steel wheel with a non-stick coating eliminates imbalance in heavy grease applications. The steel wheel is a backward-inclined, non-overloading centrifugal type. Drain Trough All grease and water is collected at one-point for easy disposal. Curb Cap with Mounting Holes Prepunched mounting holes in the steel curb cap to ensure correct attachment to the roof. Hinged Base Allows entire fan to tilt away for access to wheel and ductwork for inspection and cleaning. Shipped for field assembly. Leakproof Construction One-piece fully welded windband to curb cap. Assures no grease will leak onto roof through the fan s seams. Motor Cover Easily removable for access to the steel motor compartment and drive assembly. Powder Coated Unit is constructed of a minimum of -gauge steel. Entire unit is powder coated with chemical-resistant Permatector finish. Motor Carefully matched to the fan load and mounted out of the airstream. Windband Uniquely spun from galvanized steel achieves superior strength and consistent material thickness. Nema-R Disconnect Switch Mounted & Wired Motor and switch are pre-wired to specified voltage. Motor Cooling Tube Maximum motor life is achieved through positive motor cooling with fresh outside air being continuously drawn through the large breather tube directly over the motor. Name Plate Exact model and serial identification number on a permanent stamped aluminum plate. Heat Baffle Extends motor life by reducing the amount of heat that penetrates through the bottom of the motor support pan. Lifting Lugs Located under motor compartment for ease of lifting unit during installation. (Not shown)

Options and Accessories XRUB. XRUD. XSEB. XSED. XRUBS. Roof Curbs Wide variety of roof curbs are available for mounting the fan to the roof, including: vented, flanged, pitched, and sound-absorbing. Vented Curb Extensions Mounts between roof curb and roof mounted fans to meet NFPA requirements of 0 in. (. cm) minimum discharge above the roof when mounted on a minimum in. (0. cm) high roof curb. Disconnect Switches Assorted NEMA rated switches are available for positive electrical shutoff and safety, including: dust-tight, rainproof and corrosion-resistant. Hinge Kit Allows maintenance personnel to hinge the entire fan up to gain access to wheel and ductwork for regular inspection and cleaning. (Roof Upblast only) Hinged Base Allows for easy maintenance. Hinge and restraining cables are factory mounted to a subbase attached directly to curb without additional height added. Grease Trap Aluminum trap designed to collect grease residue to avoid drainage onto roof surface. (Roof Upblast only) Grease Trap with Absorbent Material Same as above, with an absorbent material to collect grease residue for easy disposal. (Roof Upblast only) Windband Extension Aluminum tube raises fan s discharge an additional in. (. cm) for special code requirements. Non-Stick Wheel Patented coating helps prevent wheel imbalance in heavy grease applications and allows build-up on wheel to be easily removed. Patent No.,0, Coatings Wide variety of coatings and colors are available for decorative to acidic applications. Permatector Hi-Pro Polyester Baked Enamel Permatector is our standard coating, typically used for applications that require corrosion resistance in indoor and outdoor environments. Hi-Pro Polyester is resistant to salt water, chemical fumes and moisture within more corrosive atmospheres. Baked Enamel Decorative Coatings come in standard, decorative colors or color match any color. Clean Out Port Patented removable plug allows for easy spray or steam cleaning of wheel through the windband. (Roof Upblast only) Patent No.,0, Birdscreen Galvanized or aluminum rigid wire to protect the fan s discharge from birds or small objects. (Galvanized is standard on Sidewall) Self-Draining Grease System Drain grease and rain water back through the ductwork into the specially designed Accurex hood. The hood then channels grease and rain water into the restaurant s floor grease trap. Curb Seal Rubber seal between fan and curb to assure proper sealing when attached to a curb. Dampers Designed to prevent outside air from entering back into the building when fan is off. Includes: backdraft and motorized dampers. (N/A with UL/C-UL US ) Tie-Down Points Four brackets located on the windband for securing the fan in heavy wind applications. Drain Connection Allows for single-point drainage of grease, water or other residue. (Roof Upblast only) Speed Controllers Available for use with shaded pole and permanent split capacitor open motors on direct drive fans. They provide an economical means of system balancing.

Options and Accessories XRUB. XRUD. XSEB. XSED. XRUBS. The following chart shows which options and accessories are available on Accurex s roof upblast and sidewall XRUB XRUD XSEB XSED XRUBS exhaust fans. XRUB XRUD XSEB XSED XRUBS Options and Accessories Roof Curbs Optional Optional Optional Vented Curb Extensions Optional Optional Optional Disconnect Switches Standard Standard Standard Standard Standard Hinge Kit Optional Optional Optional Hinged Base Optional Optional Standard Grease Trap Optional Optional Optional Grease Trap with Absorbent Material Optional Optional Optional Non-Stick Wheel Optional Optional Standard Windband Extension Optional Optional Coatings Optional Optional Optional Optional Standard Clean Out Port Optional Optional Standard Birdscreen Optional Optional Standard Standard Self-Draining Grease System Optional Optional Optional Curb Seal Optional Optional Optional Dampers Optional Optional Optional Optional Tie-Down Points Optional Optional Optional Drain Connection Optional Optional Optional Speed Controllers Optional Optional

Typical Installations XRUB. XRUD. XSEB. XSED. XRUBS. Factory Wired Motor to Disconnect General Clean Air or Fume Hood (Non-Grease) Exhaust fans are designed for applications ranging from clean air to contaminated air. A typical installation is shown. Sizes and smaller can handle temperatures up to F ( C). " or " in. Wiring by Others Damper Commercial Kitchen (Grease) Roof Deck Recommended Duct and Damper Size Recommended Roof Opening Sizes 0 and larger are designed to meet restaurant and food service applications. These fans are UL/C-UL US Listed for grease removal and have been tested under high temperature [00 F (0 C)] and abnormal flare-up [00 F ( C)] conditions. Due to high temperatures and grease-laden airstreams in commercial kitchen ventilation, system designers must be aware of governing codes and guidelines. The National Fire Protection Association (NFPA) is the primary source upon which many codes for commercial kitchens ventilation are based. Selected information from NFPA is shown below. Local code authorities should be consulted before proceeding with any kitchen ventilation project. Exhaust fans used in kitchen ventilation applications must have external wiring (wiring must not be installed in the airstream). Installation must include a means for inspecting, cleaning and servicing the exhaust fan (e.g. hinged curb cap). No dampers are to be installed in the system. NEMA R Disconnect factory wired from motor to disconnect through the breather tube (Optional) Wall Minimum 0 in. ( mm) Discharge Height Grease Trap in. (0 mm) min. Welded Duct by others min. of in. ( mm) above roof deck per NFPA Hinged Curb Cap Vented Curb Extension External Wiring Liquid Tight Flexible Conduit by Others Mounting Bolt Hole Circle Recommended Wall Opening Welded Duct by Others Roof Deck External Wiring Liquid Tight Flexible Conduit by Others Recommended Roof Opening Note: Above installations are recommendations based on national codes. Local authority may supersede these recommendations.