Astor 20 Colony Counter User s Manual

Similar documents
Mod: KLD6-12/35XLAS-N

Instructions for use and installation Cooker Hood

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

RMHDT90SS/ - RMHDT100SS/ - RMHDT110SS/ Instructions Manual.

LEIHDS110SC/ LEIHDS110BC/ Instructions Manual.

M2TECH PALMER POWER STATION LOW NOISE BATTERY POWER SUPPLY/CHARGER USER MANUAL

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

INSTALLATION RULES for SCS/SENSOR Pt100

Gavita HortiStar 1000 DE EU/US

CCD-2000 UNIVERSAL REAR VIEW CAMERA INSTRUCTION MANUAL CAMERA DE VUE ARRIERE UNIVERSELLE MODE D EMPLOI UNIVERSAL RÜCKFAHRKAMERA

3. Operating instructions: Minor 200

Battery Charger. Series EASY Charger. User s manual

DC POWER SUPPLY ALIMENTATION C.C.

KeContact P20. User manual

OPERATING INSTRUCTION

Installation manual wall-mounted distributor

Bluetooth Smart Speed/Cadence Sensor Instruction Manual

Installation manual portable distributors

ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Battery Charger Series EASY Charger

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

Installation Instructions

Multistage Air Filtration Systems Instruction Manual

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

GAN Electronic 600W/750W SE US

Instruction manual. RP800 - HYDRAULIC actuator, load 150Kg. RP815 - LINAK actuator, load 150Kg

Mini Multimeter with Non-Contact Voltage Detector (NCV)

GAN Electronic 750W/1000W DE US

LED Twister II. User manual UK Version 1.0

MICRO-INVERTER OMNIKSOL M-300

INSTRUCTION MANUAL SPECIFICATIONS:

SIZING OF SOLAR GENERATOR

Lumitester PD-20 Control Kit

Switching DC Power Supply

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

60 Watt Industrial LED Low Bay Light

Dawson DDM190D. Digital Multimeter User s Manual

Uninterruptible power supply Supply MEg101.4

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

HEINE NT4 MED V

OPERATIONS MANUAL CR Thermoreactor

X-RAY FILM VIEWER FOR MAMMOGRAPHY HIGH LIGHT INTENSITY

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

UK Weighing Federation Technical Articles

Eclipse LED Hyperion LED ASSEMBLY INSTRUCTIONS

Installation Instructions

Operating Instructions. International English. CCS Dust Extractor

Maintenance Bypass Switch

Manual. Taucher O.Wulf 6. R/C Pilot boat. No. 2072

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Installation and Operating Instructions. Solar System Controller ISC3020

GENERALITIES TECHNICAL FEATURES

Register your instrument! HeatSealer S100. Operating manual

Battery Charger JCB-FCH20LI2

Breezair TBA 550 Installation Manual

Installation Instructions BLTR and 2BLTR Relight Assembly

PV Generation System. Solar Charge Controller SPECIFICATION

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Air-Operated Waste Oil Drainer

OPERATING INSTRUCTIONS

Operating manual. ZSK Automatic Bobbin Winder 230V 50Hz/60/Hz / Z

Z100A Clinical Centrifuge

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

Instructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )

Pan and Tilt Head CDD2416-T

Q-Series Ultraviolet Lamps OPERATOR S MANUAL

KHYBRID. Hybrid Mechanical Backlit Keyboard. Installation Quickguide

ELECTRIC ACTUATOR MOD. VB015 MAINTENANCE AND INSTALLATION INSTRUCTIONS OF VALBIA ELECTRIC ACTUATORS

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

USER MANUAL MPS 1-5KW SERIES

DSP led gaming monitor USER MANUAL

Installation Instructions

Operating and installation instructions

HOYMILES MICRO-IVERTER MI-250

INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

OPERATING INSTRUCTIONS

English. Instruction and operation manual S 212. Dew point sensor

EFC Instructions Manual

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

SunPro Complete DE Fixture 1000W HPS

Troubleshooting. CryoSmart 1 - CryoSmart 20

3 PHASE TESTER & MOTOR ROTATION TESTER

Overhead lift Roomer 5200

Re.Formance Line INSTRUCTION MANUAL 1703

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Angle Grinder Holder

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

150-Lb. Drywall and Panel Hoist

USER MANUAL. Insulation Tester + DMM. Model MG320

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

Lamp kit. Installation manual SIM 7 series R

SeekTech Inductive Clamp

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Transcription:

... Astor 20 Colony Counter User s Manual... rev. 09/2014

... Astor 20 Colony Counter User s Manual... WARNINGS... 3 SYMBOLS USED IN THIS MANUAL... 3 FEATURES... 4 MECHANICAL FEATURES... 4 ELECTRICAL FEATURES... 4 CLIMATIC FEATURES, STORAGE, PACKAGING AND USE... 4 ELECTRICAL CONNECTION... 5 MATERIAL SUPPLIED... 5 INSTALLATION... 5 USAGE... 5 BATTERY REPLACEMENT... 6 FRONT PANEL... 7 TECHNICAL ASSISTANCE... 7 CLEANING... 8 ACCESSORIES... 8 WARRANTY... 8 DOCUMENT VALIDITY... 9 DISPOSAL... 9 2

WARNINGS Carefully read this User Guide before using the equipment. This manual is an integral part of the product and must be conserved for future consultation. In it you can find important information regarding safety of use and maintenance. Read the instructions contained in this manual carefully before installation, use and before processing any operation of adjustment or maintenance. This equipment has been realized for the counting of bacteria and mould colonies grown in Petri dishes. Every use which differs from the description above, will be considered as improper use and will invalidate the warranty. Even if this device is provided with protections, its use without following the described procedures could produce a wrong working and damages on the equipment. The manufacturer is not liable for damages to people or things caused by improper use of the equipment and / or not respect of the laws, regulations and instructions described below. SYMBOLS USED IN THIS MANUAL Carefully read the instructions contained in the manual before using the equipment. Every action performed on the equipment must comply with the indications described in the manual. 3

Suggestions and clarifications for a better functioning and a correct interpretation of the information contained in the manual. Presence of danger: injuries may occur. Please follow the instructions contained in the related paragraph. Presence of danger: electrical shock may occur. Please follow the instructions contained in the related paragraph. FEATURES MECHANICAL FEATURES Features Dimensions of Petri dishes Dimensions (l x p x h) Weight Description Up to 90 mm diameter (adapter included) 110 mm 225 x 215 x 88 mm 1,2 Kg ELECTRICAL FEATURES Features Power supply Power adapter Max. variability of the tension Transitory overload Absorption Display Light source Battery Description 12 V DC INPUT: 110 V AC 240 V AC, 1,6 A Max OUTPUT: +12 V DC, 3 A ±10% of the nominal tension II 2 W Digital with 8 digits LED CR2477 type CLIMATIC FEATURES, STORAGE, PACKAGING AND USE Features Description Working temperature range from 5 to 36 C Relative humidity max. 80% for temperatures up to 31 C, with a linear decrease up to 50% at a temperature of 40 C. Pollution degree 2 IP protection grade 20 4

ELECTRICAL CONNECTION Avoid placing the equipment near heating sources or windows hit by sunlight. According to European laws, the equipment must be connected to a grounded plug. The manufacturer will not be responsible for possible damages to people or things, if caused by a lack of compliance with this rule. In case your electric socket is not compatible with the plug of the equipment, make it replaced with an adequate one by competent technicians. Avoid the use of multiple adapters or additional cables. MATERIAL SUPPLIED The equipment always comes with the following material: Code Description Quantity PLXRDT.67175 Colony counter adapter 1 -- Power adapter 1 -- Power cable 1 INSTALLATION 1. Connect the power supply to the colony counter. 2. Connect the power supply to the electrical socket. 3. Press the main switch located on the upper right side of the equipment. The translucent backlit plate holder will light up automatically. 4. The display is always on, as it is battery operated (the battery lasts about 3 years). USAGE 1. Verify that the value on the display corresponds to 0 and reset it if necessary by pressing the Reset key. 2. Place an upturned Petri dish on the backlit plate holder; if needed, use the plate adapter to fix the plate steadily. 3. Count the colonies by marking them on the Petri dish with any marking pen. 4. The equipment bases its enumeration ability on pressure sensors located under the backlit plate holder, so that Astor 20 automatically increases the counting after every single pressure of the marking pen on the Petri dish. Every count is confirmed by an acoustic signal. 5. After counting, read the result on the display. 6. Reset the display before starting a new count. 5

BATTERY REPLACEMENT For the battery replacement proceed as follows: 1. Remove the fixing screws underneath the equipment. 2. Remove the screws that fix the electronic counter. 3. Remove the battery cover from the case. 4. Remove the battery from the side of the case. The battery will come loose if you put the battery side face down and gently shake the unit. 5. Before inserting, wipe clean the surface of the battery. 6. Insert the battery paying attention that the + and sides are in the proper position. 7. After replacing the battery return the battery cover to the case. Check that the hook of the battery cover is properly engaged. 8. Before any use press the Reset key on the front. 9. Fix the electronic counter to the case verifying its tightness. 10. Close the equipment. 6

FRONT PANEL 1 3 2 4 5 N. Description 1 Counter 2 Reset key 3 Main switch 4 Adapter 5 Backlit plate holder TECHNICAL ASSISTANCE In case the equipment does not work please check that: 1. the plug of the equipment has been correctly placed in the electric socket; 2. the plug of the power supply has been correctly placed in the equipment; 3. the main automatic switch of the laboratory is not in OFF position; 4. an electric black-out is not occurring; 5. the equipment controls are in the correct position; If the problem does not disappear, please contact the Service Department of your local Astori distributor. In case you may need technical assistance, please communicate the model and the serial number of the equipment. 7

CLEANING Turn the equipment off and always unplug it before starting any cleaning operation. Do not use water but use a dump cloth instead. Use a neutral all-purpose cleaner. Do not clean the equipment using aggressive detergents or alcohol. ACCESSORIES Code Description Quantity 66131 Accessory benchtop lens with lamp on an adjustable arm 1 WARRANTY The warranty period lasts 12 months starting from the date stated on the Packing List and it covers manufacturing faults only. It does not cover: malfunctionings, damages or faults appeared after the warranty terms or resulting from an improper use of the equipment; from neglicence or carelessness; from wrong installation or wrong maintenance; from technical assistance carried out by unauthorized personnel; from transport or corrosion damages; from the use of not original replacement parts. Warranty will be instantly invalidated in the event that the serial number of the product is found to be modified or cancelled. Warranty does not cover damages originated by overvoltages caused by the electrical net which the equipment is connected to. Should you send the equipment, the use of the original Astori package or a strong box filled with styrofoam is mandatory. 8

DOCUMENT VALIDITY ASTORI TECNICA reserves the right to review and modify this document without any notice. Note: any variation will not affect the respect of the directives. These images have an explicative purpose only and they may differ from reality. DISPOSAL The symbol of the crossed garbage collector indicates that the product at the end of its useful life should be collected separately from normal garbage. The user will give the equipment, at the end of its usage, to centers for collection of electronic and electrotechnical garbages according to rules and laws. The proper collection of the disused equipment, the recycling, treatment and disposal contribute to avoid possible negative effects on the environment and human health and encourage the recycling of the materials that compose the equipment. 9