HBO Range Gamme HBO. Hall effect open-loop current sensors. Capteurs de courant à effet Hall boucle-ouverte. Technical argumentation

Similar documents
VS Range Gamme VS. 100% electronic voltage sensors. Capteurs de tension 100% électronique. Technical argumentation. Argumentation technique

VD Range Gamme VD. 100% electronic voltage detector. Détecteur de tension 100% électronique. Technical argumentation. Argumentation technique

Current sensors CS range

Current sensors ES range

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

DRAFT TANZANIA STANDARD

SOUTH AFRICAN NATIONAL STANDARD

INDUSTRIAL POWER SUPPLIES SFL-SERIES

AE 9... AE 40 Contactors NE... Contactor Relays

Solid state DC Motor reverser SGRD This product was designed with an evolutionary spirit, other possibilities on request :

Differential Pressure Sensors

ZP2.5-PE Spring Terminal Block Ground

ISO-TECH IPS1810H and IPS1603D DC power supply ISO-TECH IPS 1810H et IPS 1603D Alimentation électrique c.c.

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Safety technique. Emergency Stop Module BH 5928, BI 5928

ABB France 3 rue Jean Perrin CS CHASSIEU Cedex FRANCE. Eppelheimer Str HEIDELBERG - ALLEMAGNE. Contacteur Contactor

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

ZP2.5-4P Spring Terminal Block Feed-through

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

Transformer bushings, type GOH. Technical guide

C E R T I F I C A T E O F C O M P L I A N C E

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Safety Standards. Model Number:

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Model Number Structure

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

ZDP Pluggable Terminal Blocks Feed-through

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

EPI Applications. Features

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

ZK2.5-PE-4P PI-Spring Terminal Blocks Ground with 4 connections

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

ZK4-4P PI-Spring Terminal Blocks Feed-through with 4 connections

Electronic Ignition Module

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

Load (2) Single or Dual

MTPi2000C - 80 KW (RANGE)

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS4-PE Screw Clamp Terminal Blocks Ground

EM DC Multi-Function DC Energy Meter

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

Pressure Sensors. for liquid and gaseous media

Maximum Input Current Vin=18V, 100% Load A Vin=24V ma No-Load Input Current

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

ASTAT XB USER MANUAL. 1 Caution Statements

M5200 Industrial Pressure Transducer

Open Frame Power Supplies

FPT Applications. Features

Differential Pressure Sensors

Main catalogue. ESSAILEC Test Blocks

ZS10 Screw Clamp Terminal Blocks Feed-through

Overview. Contents. Overview

Industrial Power Supplies

Technical Data Sheet Sigma Series DE Meter

ZS4 Screw Clamp Terminal Blocks Feed-through

Declaration of Conformity

Paddle-wheel flow controller for On/Off control

B70SR12424A/B/C/D 12V Output DC/DC Converter, Box Type Package

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

Electrical data Nominal voltage AC/DC 24V Nominal voltage frequency 50/60Hz

Miniature Relay PT 2 pole 12 A, 3 pole 10 A or 4 pole 6 A DC- or AC-coil

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Features. Description. Table of Contents

Administrative Circular TO ALL NATIONAL COMMITTEES. Dear Sir/Madam, Co-operation and Licence Agreement between IEC and IEEE

Thermocouple Thermometer Models

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Cat N 3. OVERALL DIMENSIONS

POWER-WIN TECHNOLOGY CORP.

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

Pressure Transmitters

Essential equipment for all your requirements

J TS 7090 Thyristor power switch

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

LDX-C120 Series is a 120 W integrated DIN Rail Battery Charger / DC UPS Power Supplies, suitable for wide variety of industrial applications.

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

SAV Electronic Valve Actuator

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

LS series limit switches

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Transcription:

Technical argumentation Argumentation technique HBO Range Gamme HBO 1SBC146155D1701 Argumentation technique Gamme HBO1.1 - Version 1.1 Hall effect open-loop current sensors Capteurs de courant à effet Hall boucle-ouverte 1

SUMMARY 1 The customers' technical needs 3 2 The aimed applications 5 3 The technology 5 4 The range 5 5 The main characteristics 5 6 The options and accessories 5 7 The electrical connections 5 8 The used standards 5 9 The technical documentation 5 SOMMAIRE 1 Les besoins techniques clients 3 2 Les applications visées 4 3 La technologie 5 4 La gamme 5 5 Les principales caractéristiques 5 6 Les options et accessoires 5 7 Les connexions électriques 5 8 Les normes appliquées 5 9 La documentation technique 5 This document cannot be duplicated in any manner, without prior authorisation from ABB Entrelec Ce document ne peut-être dupliqué sous quelque forme. que ce soit, sans autorisation préalable de ABB Entrelec Current and voltage sensors HBO range Technical Presentation ABB Entrelec - 1 - HBO Presentation 1.0 2

Technical presentation summary 1 2 3 4 5 6 The customer s needs The aimed applications The technology The range The main characteristics The accessories ABB Entrelec - 2 - HBO Presentation 1.0 7 8 9 The electrical connection The used standards The technical documentation 1 The customers needs $ Price 100% OK High quality High performances 2098 Reliability ABB Entrelec - 3 - HBO Presentation 1.0 IEC EN Compactness Latest standards Reliable supplier 3

2 The aimed applications Industrial applications : UPS Drives Welding machines Robotics... ABB Entrelec - 4 - HBO Presentation 1.0 3 The technology Functionning principle Open loop Hall effect technology : Ip + ABB Entrelec - 5 - HBO Presentation 1.0 A Vs Out OV Vs = k * Ip Instantaneous value The output Vs of the sensor is a voltage proportional to the input primary current Ip - 4

4 The range General range presentation HBO100 HBO1000 From 100A up to 1000A One single case for the 7 ratings ABB Entrelec - 6 - HBO Presentation 1.0 4 The range HBO mechanical layout 70 10 6 90 78 φ4.6 φ60 φ32 70 ABB Entrelec - 7 - HBO Presentation 1.0 12.5 φ4.6 8 1.6 7 4.6 25 25 5.5 21 15 1 4 60 3.5 5

5 The main characteristics HBO range : main characteristics Product Type HBO 100 200 300 400 500 600 1000 Nominal primary current Ipn (A rms) 100 200 300 400 500 600 1000 Measuring range (A peak) ±300 ±600 ±900 ±1100 ±1200 ±1300 ±1500 Supply voltage (V dc) Output voltage @ Ipn V Accuracy @ Ipn and +25 C % Operating temperature C ±12 ±15 (±5%) ±4 1-25 +85 ABB Entrelec - 8 - HBO Presentation 1.0 For further information, please contact us. 6 The accessories Female Molex connector : Kit of ten female Molex connectors (Reference : 1SBT210000R2001) ABB Entrelec - 9 - HBO Presentation 1.0 6

7 The electrical connection HBO : connection diagram +Va Voltage output Power supply +Va ABB Entrelec - 10 - HBO Presentation 1.0 Ip HBO Current sensor Vs 0V -Va Vs V Voltmeter (High impedance measuring device) 0V -Va 7 The electrical connection HBO : connection diagram +Va Voltage output Power supply +Va ABB Entrelec - 11 - HBO Presentation 1.0 Ip Rm 10kΩ HBO Current sensor Vs 0V -Va Vs Rm 0V -Va 7

8 The used standards: Industrial applications EN50178 (Oct 1997) Safety requirements ABB Entrelec - 12 - HBO Presentation 1.0 Rated voltage Pollution degree Insulation distance Creepage distance Partial discharges : 500V rms or 750Vdc : PD2 (pollution normally conducting and random condensation) : OV3 (fixed installations with requirements of reliability and disponibility) : 14 mm air distance (reinforced insulation) : material group II (400<CTI<600) : 14.2mm (reinforced insulation) with grooves having minimum 2 mm : 884V (10pC) 8 The used standards: Industrial applications EN50178 (Oct 1997). Environmental requirements Climatic : Tab 7, class 2K3 : -25 +70 C : 95% relative humidity : max 60gr of water / m 3 : 70 à 106kPa ABB Entrelec - 13 - HBO Presentation 1.0 EMC : design and tests in accordance with EN61000-6-2 and EN61000-6-4 8

8 The used standards: Industrial applications EN50178 (Oct 1997). Testing (see details in the concerned Type Test Report) ABB Entrelec - 14 - HBO Presentation 1.0 Functioning : @ +25 C, @-25 C, @+85 C : delay time : di/dt : bandwidth : overload : magnetic environment Other climatic tests : humid heat : storage 8 The used standards: Industrial applications EN50178 (Oct 1997). Testing (see details in the concerned Type Test Report) ABB Entrelec - 15 - HBO Presentation 1.0 Dielectric EMC (immunity) EN61000-6-2 : dielectric test : insulation resistance : partial discharges : burst : electrostatic discharges : conducted perturbations : electromagnetic fields : network magnetic fields 9

8 The used standards: Industrial applications EN50178 (Oct 1997). Testing (see details in the concerned Type Test Report) EMC (emission) EN61000-6-4 : radiated Mechanical : vibrations : shocks ABB Entrelec - 16 - HBO Presentation 1.0 10

11

As part of its on-going product improvement, ABB reverses the right to modify the characteristics of the products described in this document. The information given is not contractual. For further details please contact the Company marketing these products in your country. Publication N 1SBC146155D1701 Printed in France (Y 03.2005 L) ABB Entrelec Control Division 10, rue Ampère Z.I. - B.P. 114 F-69685 Chassieu cedex / France Telephone: +(33) (0) 4 7222 1722 Fax: +(33) (0) 4 7222 1969 http://www.abb.com/lowvoltage E-mail : sensors.sales@fr.abb.com 12