Kämmer Series Low Flow Valves

Similar documents
Kämmer Series Low Flow Valve

Kämmer Series Split Body Valves

Kämmer Multi-Z Severe Service Valves

flowserve.com Kämmer Multi-Z Kämmer Multi-Z Severe Service Valves

Vogt Valves The Connection Bulletin for Forged Steel Globe Valves for Water-Free Chlorine Service Class 300, 600 & 800 CB 07

Desuperheater FCD VLENTB /11. Experience In Motion

Vogt Valves The Connection Bulletin for Y Pattern Globe & Check Valves Class 1690 & Class 2680 CB 18

TECHNICAL BULLETIN. NAF Setball SF Ball Sector Valves. Experience In Motion. flowserve.com. NAF Setball FCD NFENTB A4 02/16

TECHNICAL BULLETIN. Valdisk TX3 Triple Offset Butterfly Control Valve. Experience In Motion FCD VLENTB A4 1/16

Mark 100. Technical Bulletin F C D F C A T B

High Pressure Valves Series Angle Valves Series Angle Valves

USER INSTRUCTIONS. Valtek Control Products Spring Cylinder Linear Actuators. Installation Operation Maintenance. Experience In Motion

TECHNICAL BULLETIN. Audco Ball Valve. Reduced Bore Fire safe Flanged Ball Valves 51/52 Series. Experience In Motion

NAF Duball DL Pocket Ball Valves TECHNICAL BULLETIN FCD NFENTB A4 11/17

Experience In Motion. Flowserve Control Valve Products North American Quick Response Centers

Valtek Tek-Check. Check Valves

TECHNICAL BULLETIN. NAF Trunnball DL Ball Valves. Experience in Motion FCD NFENTB A4 09/14

Valtek Tek-Check Control Valves Valtek Tek-Check

Valtek Valdisk 150. Valtek Valdisk 150. Control Valves. Flowserve Corporation, Valtek Control Products, Tel. USA

flowserve.com Valtek ShearStream Segmented Ball Valve Series

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

flowserve.com Kämmer SmallFlow Low and Micro Flow Valves

General Service Valves Series Globe Valves Series Angle Valves Series Way-Valves

Edward. Equiwedge Forged Gate Valvee. Experience In Motion

TECHNICAL BULLETIN. Valtek Multi-Z Anti-Cavitation Control Valve. Experience In Motion. Valtek Series Multi-Z FCD VLENTB /10

Valtek Spring Cylinder Linear Actuators

TECHNICAL BULLETIN. NAF Duball DL Ball Valves. Experience in Motion FCD NFENTB A4 12/14

S-17 CATALOG. Forged Steel Strainers

MARPAC K SERIES. Full Bore Fire Safe Flanged Ball Valves

Limitorque Actuation Systems B320 Series. Rugged and dependable bevel gear operators for manual or motorized valve control applications

Valtek Valdisk 150. Valtek Valdisk 150. Control Valves

Valtek Flow Boosters

USER INSTRUCTIONS. Spring Diaphragm Rotary Actuators. Installation Operation Maintenance. Experience In Motion FCD VLAIM /12

Flow Control Division. Kammer Control Valves. Kämmer Series Corrosive Application Valves

Kämmer Series Corrosive Application Valves

USER INSTRUCTIONS. Limitorque TM V Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 02/15

Limitorque Accutronic MX/WTR Performance and Dimensions. Limitorque Actuation Systems

Valtek MaxFlo Control Valves

Flowserve Spring Diaphragm Rotary Actuators

WORCESTER CONTROLS F519/529/819/829. Full Bore Fire Safe Flanged Ball Valves

Limitorque Actuation Systems PT Series Worm Gear Operator

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

ISC Series Innovative Standard Cartridge Seals

Limitorque HBC Series Worm Gear Operators

Installation Instructions

Installation Instructions

TECHNICAL BULLETIN. Valtek MaxFlo 4. Eccentric Rotary Plug Control Valve. Experience in Motion FCD VLENTB AQ 9/16

EDELSTAHL a. Flow Control Division. Kammer Control Valves. Kämmer Series Kämmer Series Aseptic and Sanitary Valves

Installation Instructions

Limitorque. HBC Series Worm gear operators proven in the most demanding situations

TECHNICAL BULLETIN. Valtek MaxFlo 4. Eccentric Rotary Plug Control Valve. Experience in Motion FCD VLENTB AQ 11/15

Installation Instructions

Worcester Controls Directional Ball Valves

Installation Instructions

USER INSTRUCTIONS. Valtek Valdisk TX3 Triple Offset Butterfly Control Valve. Installation Operation Maintenance. Experience In Motion

Logix 3800 Digital Positioner

Installation Instructions

Installation Instructions

PMV. P5 Pneumatic Positioner. Product Information

TECHNICAL BULLETIN. Segmented V-port Ball Valves. Experience In Motion FCD VLENTB

Split Body Valves Series Globe Valve Series Angle Valve Series Way Valve

Tri-Pac E325 / E525 Ball Valve Three-Piece Bolted Body, In-Line Maintainable, Regular and Full Port. McCANNA/MARPAC Valves RO400-R4

Installation Instructions

TECHNICAL BULLETIN. Valtek GS. General Service Control Valve FCD VLENTB0300A4 03/14

Valtek VL-HC Spring Cylinder Linear Actuators

Installation Instructions

TECHNICAL BULLETIN. Valtek GS. General Service Control Valve FCD VLENTB0300AQ 03/13

Flowserve Anchor Darling Isolation Valve Application

flowserve.com Limitorque LRP Limitorque Rack & Pinion Pneumatic Actuator

Solenoid Block Kit for Series 90 Modular Accessory System Installation, Operation and Maintenance Instructions

Rotary Valve Maxflo + 60 and 80 Opening type NT

flowserve.com Durco PlugSeal Valve ASME Class 600 Plug Valves Serving the Worldwide Desalination Industry Experience In Motion

Logix 3800 Digital Positioner

Accord DS/DM Series UltraSwitch Switch box

TECHNICAL BULLETIN. Logix 505si Series Digital Positioner. Experience In Motion FCD LGENTB /13

Installation Instructions

Flow Control Division

Valtek Beta Positioner. Valtek Beta Positioners. for Control Valves

Valtek ShearStream Control Valves

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

RVX Upgrade. ISO 13709/API 610 back pullout retrofit. Experience In Motion

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)

T 8053 EN Type and Type Pneumatic Control Valves Type 3252 High-pressure Valve

Valtek XL Series High Performance Positioner. for Control Valves

TECHNICAL BULLETIN. Valtek ShearStream SB Control Valves. Segmented V-port Ball Valves. Experience In Motion VLEETB

Product Specification

Installation Instructions

SPECIFICATIONS. Limitorque MX. Selection Data. Experience In Motion. Performance and Dimensions for MX Series 05 through 150 Electric Actuators

EDELSTAHL. Kämmer Series Aseptic and Sanitary Valves

Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

Kämmer Series Multi-Z FCD KMENTB /16 TECHNICAL BULLETIN. Kämmer Multi-Z Severe Service Valves FCD KMENTB /16. Experience In Motion

E818/828 Series Fugitive Emissions 150# and 300# Flanged 2" - 8" Two-Piece Ball Valves Installation, Operation and Maintenance Instructions

McCANNA Actuation Systems B

USER INSTRUCTIONS. Limitorque HBC Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM A4 (10/14)

FlowTop Control Valves

Series 240 Pneumatic Control Valve Type and Type Globe Valve Type 3241

GLOBE 2 WAY CONTROL VALVE SERIES - 110

Transcription:

flowserve.com Kämmer Series 030000 Low Flow Valves

Description Kämmer series 030000 low flow valves are designed for precision controlling up to PN40. The body is a precision casting for high finishing accuracy. Together with the series 1 actuator it forms a compact control valve. On request a special calculating programme is available to define the C vs -values and the actual rangeability. Standard valve with female thread

flowserve.com Technical Data Valve body style Characteristics Seat leakage, standard Globe valve Equal %, linear, On - Off 0.01 of rated C vs -value Material for plug / seat See table on page 5 Packing PTFE for temperatures up to 200 C (392 F) Grafoil for temperatures over 200 C (392 F) PTFE packing for oxygen service Packing according to German clean air act PTFE soft seat T = max.150 C (300 F) In seat ring C vs 0.1 Body gasket Extensions PTFE for temperatures up to 200 C (392 F) Grafoil for temperatures over 200 C (392 F) Standard, normalising fins, bellows seal C vs -values See table on page 5 Connections Female thread G ½" or NPT ½" Optional: As compact valve with series 1 actuator DIN flanges. ANSI flanges for special applications Valve Body CF8M 3

Designs Valve with normalising fins -30 to 0 C resp. 250 to 400 C Valve with steam jacket Valve with bellows seal 4 Special body design with weld-on flanges Valve with normalising fins -30 to 0 C (-22 to 32 F) resp. +250 to +400 C (+482 to +752 F)

flowserve.com Standard C vs Values Cvs value (turbulent) Stroke mm (in.) Stem diameter mm (in.) Seat diameter mm (in.) Rangeability* Standard plug material Standard seat material Characteristics Linear Characteristics equal% Alternative material for seat/plug Hastelloy C Monel, Titanium, Alloy 6 0.0022 0.0029 0.0038 0.0054 0.0079 0.013 10 (0.39) 6 (0.24) 2 (0.08) 25:1 Alloy 6 1.4122 0.020 0.029 10 (0.39) 6 (0.24) 3 (0.12) 50:1 Alloy 6 1.4571 0.047 0.074 0.12 0.19 3 (0.12) 0.29 10 (0.39) 6 (0.24) 50:1 1.4571 1.4571 0.47 4.5 (0.18) 0.74 1.2 7 (0.28) 1.9 10 (0.39) 6 (0.24) 50:1 1.4571 1.4571 2.9 10 (0.39) * For calibration conditions 5

Dimensions mm (in.) and Weights kg (lb.) Connections Length A Height F Weight Std. Fins Bellows Std. Fins Bellows Female thread 80 (3.15) 0.7 (1.5) 1.2 (2.6) 2.2 (4.9) DN 10 130 (5.12) 2.0 (4.4) 2.5 (5.5) 3.5 (7.7) DN 15 130 (5.12) 2.2 (4.9) 2.7 (6.0) 3.7 (8.2) G1/2 KÄMMER PN40 1.4581 A F Flange DN 20 DN 25 150 (5.90) 160 (6.30) 45 (1.77) 85 (3.35) 130 (5.12) 2.4 (5.3) 3.3 (7.3) 3.0 (6.6) 3.5 (7.7) 4.1 (9.0) 4.8 (10.6) ½" 178 (7.00) 2.2 (4.9) 2.7 (6.0) 3.7 (8.2) ¾" 181 (7.13) 2.4 (5.3) 3.0 (6.6) 4.1 (9.0) 1" 184 (7.24) 3.3 (7.3) 3.5 (7.7) 4.8 (10.6) Model Code 0 3 0 0 P 2 Valve type Bonnet extension Actuator 030 Series Globe valve 030 000 0 1 3 Standard Normalising fins Bellows seal H1 37 Manual handwheel Pneumatic with integral positioner P0/P1 P2 Pneumatic Series 1 and 2 E1 Electric motor 6

flowserve.com Other Kämmer micro-flow valves Kämmer micro-flow series 080000/081000 Kammer series 080000 / 081000 ¼" low flow laboratory valves are designed for precision controlling up to PN400. The body is manufactured from bar stock stainless steel and is easily adapted to meet application requirements. Together with the series 1 actuator it forms an extremely compact control valve. Upon request a special calculating programme is available to define the K vs values and the actual rangeability. Kämmer Laboratory valves series 185000/187000 Kämmer microflow series 185000 and 187000 are ½" laboratory valves designed for precision controlling. The bodies in stainless steel and C-steel are manufactured from forged material, the bodies for all other special materials are manufactured from bar stock. The bodies are, therefore, easy to adapt for application requirements. Together with the series 1 or 2 actuators they form a compact control valve. Upon request a special calculating programme is available to define the K vs values and the actual rangeability. 7

Worldwide Regional Headquarters Flowserve Corporation Flow Control 1350 N. Mt. Springs Parkway Springville, UT 84663 USA Phone: +1 801 489 8611 Fax: +1 801 489 3719 Flowserve (Austria) GmbH Control Valves - Villach Operation Kasernengasse 6 9500 Villach Austria Phone: +43 (0)4242 41181 0 Fax: +43 (0)4242 41181 50 Your contact: Flowserve India Controls Pvt. Ltd Plot # 4, 1A, E.P.I.P, Whitefield Bangalore Kamataka India 560 066 Phone: +91 80 284 10 289 Fax: +91 80 284 10 286 Kämmer Products Europe, Middle East, Africa, Asia, Pacific FCD KMENBR3020-00 08/08 Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in caonnection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. 2000 Flowserve Corporation, Irving, Texas, USA. Flowserve is a registered trademark of Flowserve Corporation. Flowserve Essen GmbH Manderscheidtstr. 19 45141 Essen Germany Phone: +49 (0)201 8919 5 Fax: +49 (0)201 8919 662 Kämmer Products Americas Flowserve (FCD) Kämmer Valves INC. 1300 Parkway View Drive Pittsburgh, Pa 15205 USA Tel.: +1 412 787 8803 Fax: +1 412 787 1944 8