COMPARISON OF DIFFERENT METHODS FOR EXCITATION OF SYNCHRONOUS MACHINES

Similar documents
Asynchronous Generators with Dynamic Slip Control

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

Wind Farm Evaluation and Control

Statcom Operation for Wind Power Generator with Improved Transient Stability

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

Using energy storage for modeling a stand-alone wind turbine system

Modelling and Simulation of DFIG based wind energy system

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Studies regarding the modeling of a wind turbine with energy storage

OPTIMIZED STEAM TURBINE GOVERNOR CONTROLLING SINGLE OR MULTIPLE GRID FAULTS

Performance Analysis of 3-Ø Self-Excited Induction Generator with Rectifier Load

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Experimental Resultsofa Wind Energy Conversion Systemwith STATCOM Using Fuzzy Logic Controller

International Journal of Scientific & Engineering Research, Volume 7, Issue 6, June ISSN

ENHANCEMENT OF TRANSIENT STABILITY OF SMART GRID

Simulation of Indirect Field Oriented Control of Induction Machine in Hybrid Electrical Vehicle with MATLAB Simulink

Asian Journal on Energy and Environment ISSN Available online at

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

Modelling and Simulation of DFIG with Fault Rid Through Protection

POWER QUALITY IMPROVEMENT BASED UPQC FOR WIND POWER GENERATION

SPEED CONTROL OF THREE PHASE INDUCTION MACHINE USING MATLAB Maheshwari Prasad 1, Himmat singh 2, Hariom Sharma 3 1

Grid Connected DFIG With Efficient Rotor Power Flow Control Under Sub & Super Synchronous Modes of Operation

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Combined Input Voltage and Slip Power Control of low power Wind-Driven WoundRotor Induction Generators

Transient Stability Improvement of Squirrel Cage Induction Wind Turbine Generator using Plugging Mode

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab

Abstract. Benefits and challenges of a grid coupled wound rotor synchronous generator in a wind turbine application

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

ASSESSING BEHAVOIR OF THE OUTER CROWBAR PROTECTION WITH THE DFIG DURING GRID FAULT

Design and dimensions calculation of Inductive Rheostat as a Control Element of Synchronization Systems

Design and Control of Lab-Scale Variable Speed Wind Turbine Simulator using DFIG. Seung-Ho Song, Ji-Hoon Im, Hyeong-Jin Choi, Tae-Hyeong Kim

Laboratory Tests, Modeling and the Study of a Small Doubly-Fed Induction Generator (DFIG) in Autonomous and Grid-Connected Scenarios

ELECTRICAL POWER SYSTEMS 2016 PROJECTS

Effect of prime mover speed on power factor of Grid Connected low capacity Induction Generator (GCIG)

EPE97 OPTIMIZED DESIGN OF VARIABLE-SPEED DRIVES BASED ON NUMERICAL SIMULATION

Effect of Permanent Magnet Rotor Design on PMSM Properties

J.-J.Simond*, A.Sapin**, B.Kawkabani*, D.Schafer***, M.Tu Xuan*, B.Willy***

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

Coordinated Control of DFIG under Grid Fault Condition in Wind Energy Conversion System

Synchronous Generators I. EE 340 Spring 2011

Modelling and Analysis of Thyristor Controlled Series Capacitor using Matlab/Simulink

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

POWER TRANSMISSION OF LOW FREQUENCY WIND FIRMS

Induction Generator: Excitation & Voltage Regulation

Synchronous Generators I. Spring 2013

Full-Scale Medium-Voltage Converters for Wind Power Generators up to 7 MVA

Control Strategies for Supply Reliability of Microgrid

Pumped storage for balancing wind power fluctuations in an isolated grid

Accidental Islanding of Distribution Systems with Multiple Distributed Generation Units of Various Technologies

Hybrid Energy Powered Water Pumping System

Doubly fed electric machine

A Comparative Study of Constant Speed and Variable Speed Wind Energy Conversion Systems

Fault Rid Through Protection of DFIG Based Wind Generation System

Study of DFIG based Wind Turbine for Reactive Power Generation Capability

Transient Stability Analysis of Power System with Wind Generators

Performance of FACTS Devices for Power System Stability

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

Synchronous Motor Drives

Intensification of Transient Stability in Grid Connected Squirrel Cage Induction Generator Using Plugging Mode Operation

Matlab Modeling and Simulation of Grid Connected Wind Power Generation Using Doubly Fed Induction Generator

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

A Dual Stator Winding-Mixed Pole Brushless Synchronous Generator (Design, Performance Analysis & Modeling)

Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM

Power Factor Improvement

A Linear Magnetic-geared Free-piston Generator for Range-extended Electric Vehicles

Simulation and Analysis of a DFIG Wind Energy Conversion System with Genetic Fuzzy Controller

QUESTION BANK SPECIAL ELECTRICAL MACHINES

IEEE Transactions on Applied Superconductivity, 2012, v. 22 n. 3, p :1-5

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

Integration of Large Wind Farms into Electric Grids

Grid Stability Analysis for High Penetration Solar Photovoltaics

PERFORMANCE ANALYSIS OF SQUIRREL CAGE INDUCTION GENERATOR USING STATCOM

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

Reducing Train Weight and Simplifying Train Design by Using Active Redundancy of Static Inverters for the Onboard Supply of Rolling Stock

Use of STATCOM for Improving Dynamic Performance of Wind Farms Connected in Power Grid

A single-phase induction motor operating as a self-excited induction generator *

Modeling and Simulation of Five Phase Inverter Fed Im Drive and Three Phase Inverter Fed Im Drive

Lösungen zur Spannungsregelung in Verteilernetzen

EFFECT OF WIND TURBINE GENERATORS ON THE SMALL SIGNAL STABILITY OF POWER SYSTEMS. Kamel A. Shoush, Member, IEEE

A Variable Speed Wind Generation System Based on Doubly Fed Induction Generator

SPEED AND TORQUE CONTROL OF AN INDUCTION MOTOR WITH ANN BASED DTC

Cascaded Doubly Fed Induction Generator with a Back-to-Back Converter Connected to a Small Distributed Generation System

DOUBLE STATOR WINDING INDUCTION GENERATOR FOR RENEWABLE ENERGY CONVERSION SYSTEMS

Variable speed control of compressors. ABB drives control the compressors of the world s longest gas export pipeline

Transient analysis of a new outer-rotor permanent-magnet brushless DC drive using circuit-field-torque coupled timestepping finite-element method

THE IMPORTANCE OF INTEGRATING SYNCHRONOUS COMPENSATOR STATCOM IN WIND POWER PLANT CONNECTED INTO THE MEDIUM VOLTAGE GRID

The Modeling and Simulation of Wind Energy Based Power System using MATLAB

ECEN 667 Power System Stability Lecture 19: Load Models

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

ENERGY STORAGE FOR A STAND-ALONE WIND ENERGY CONVERSION SYSTEM

Examples of Electric Drive Solutions and Applied Technologies

Australian Journal of Basic and Applied Sciences. Resonant Power Converter fed Hybrid Electric Vehicle with BLDC Motor Drive

A STUDY OF THE CENTRIFUGAL COMPRESSOR DISCHARGE PIPELINE CONSTRAINED OSCILLATION. KIRILL SOLODYANKIN*, JIŘÍ BĚHAL ČKD KOMPRESORY, a.s.

APPLICATION OF VARIABLE FREQUENCY TRANSFORMER (VFT) FOR INTEGRATION OF WIND ENERGY SYSTEM

Transcription:

Maszyny Elektryczne Zeszyty Problemowe Nr 3/2015 (107) 89 Stefan Schmuelling, Christian Kreischer TU Dortmund University, Chair of Energy Conversion Marek Gołȩbiowski Rzeszow University of Technology, Faculty of Electrical and Computer Engineering COMPARISON OF DIFFERENT METHODS FOR EXCITATION OF SYNCHRONOUS MACHINES Abstract: The energy turnaround in Germany leads to new operating conditions for small and medium synchronous generators. Since the electricity generation through renewable energy sources, such as wind or photovoltaic, is highly volatile, generators have to run up from standstill into rated operation within several minutes. Hence, it is necessary to compensate a lack of electricity generation caused by wrong weather forecasts. Usually, gas turbine systems provide this possibility. The generator is used as a starter engine due to the connection to a frequency inverter. The excitation current is often provided by static excitation systems. Thus, it is possible to start from standstill and run up the drive until the gas turbine is able to generate a positive torque. A new excitation concept, based on an induction machine with a 3-phase rotor winding, is able to provide an excitation current at 0 rpm and eliminates the need for brushes. To verify the applicability for power systems, both systems are compared under different aspects. The control of the excitation current at different speeds and the possibility to settle shaft oscillations after electrical faults are aspects researched in the paper at hand. A power system is performed with a synchronous machine connected to a grid. Both excitation systems are modeled by equivalent circuit diagrams in Matlab Simscape. Keywords: AC machines, Brushless machines, Electromagnetic transients, Excitation system, Power system 1. Introduction The increasing amount of highly volatile energy generation, such as wind power stations and solar plants, leads to new operating conditions for fossil-fueled power plants [1]. Since it is possible that the amount of active power fed by renewable energy sources changes within several minutes, the amount of conventional fed energy has to compensate for those fluctuations. Some gas power plants operate in turning operation for up to 70 % of time per year [2], since it is not possible to start them from standstill in a short time. Common generators are direct current excited synchronous machines. Therefore, it is possible to regulate the amount of reactive power by adjusting the DC excitation. There are mainly two set-ups to feed the field winding of a synchronous generator with direct current [3], [4]: 1. Brushless excitation systems 2. Static excitation systems Brushless exciters are synchronous machines with a rotating multi-phase winding mounted to the shaft and a stationary DC coil. The multi-phase winding is connected to a rotating rectifier and the rectifier is connected to the generator s field coil. The energy conversion with synchronous machines and therefore with common brushless exciters works only while the system is rotating, since there is no electromagnetic induction in the multi-phase winding at 0 rpm. Compared with common brushless excitation systems, static excitation systems use controlled rectifiers connected via slip rings and brushes to the generator s field coil. Thus, it is possible to provide an excitation current at standstill. This system requires a higher amount of maintenance work. In order to start a turbine generator or a synchronous condenser within a few minutes from standstill without using auxiliary drives, the synchronous machine can be used as motor for the start up by using it as inverter drive. There is a wide range of inverter topologies which are appropriate for the use with synchronous machines [5]. Typical brushless excitation systems are not able to provide an excitation current at 0 rpm. Thus, it is not possible to start a generator from standstill, unless it is equipped with a static excitation system. A third excitation system uses an induction machine as inductive energy transfer system to generate a direct current without using brushes. This system is typically used for very large drive applications, such as multi-megawatt

90 Maszyny Elektryczne Zeszyty Problemowe Nr 3/2015 (107) compressor drives in liquid natural gas (LNG) plants. Fig. 1 shows the brushless excitation systems (green) typically used for large drives. Fig. 1. Schematic drawing of an induction machine based excitation system (a) and a static excitation system (b) for turbine generators The induction machine stator winding is connected to an AC power controller. The rotary field, generated by the 3-phase stator winding of the exciter, turns in the opposite direction of the rotating direction of the shaft. Thus, the operational slip of the induction machine is at s = 1 during standstill and at s = 5 during rated operation. This system is brushless and it is able to feed the generator s field coil with a DC current at standstill. Its effects on the generator performance are unknown, since it is only used as an excitation system for large drives. Those drives do not have to regulate reactive power or have to stabilize the grid during faults. Fig. 1 also shows a typical static excitation system (orange dashed). It consists of a controlled 6-pulse rectifier, which is directly connected to the rotating field coil by using brushes and slip rings. The static excitation system has the advantage of being able to feed the field coil with a negative field voltage to reduce the field current in the case of an overexcitation. It has the disadvantage that it depends on using brushes and may cause shaft voltages [6], [7]. 2. System under investigation Switching operations in the grid or grid faults can cause oscillating shaft torques, which can damage the power system and lead to mechanical failures. Thus, the excitation system has to attenuate those resonances between the rotating system and the grid. In order to verify the applicability of the induction machine exciter (IM exciter) for turbine generators, a detailed power system is performed. The control performance of the IM exciter is compared with a static excitation system. The detailed equivalent circuit of the static excitation system is modeled and the controls are taken from the ST1A standard excitation system [8]. Both excitation systems are equipped with the same power system stabilizer (PSS1A) [8]. The stabilizer modifies the input signal of the voltage controller in order to suppress shaft oscillations in consequence of grid faults or resonance excitation. It uses the shaft acceleration as input signal. The is performed by using a typical benchmark model. As depicted in Fig. 2, the generator is connected to 2 equivalent grids. Hence, they have the same short circuit capacity (SCC) of 1500 MVA. Furthermore, both lines have a length of 50 km with the same values for resistance and reactance. Both excitation systems are fed by the on-site power. The on-site power is supplied by a transformer connected to the generator s terminals. Thus, both systems get affected by voltage drops on the transmission line. Fig. 2. Simulation model for the performance analysis of the excitation systems

Maszyny Elektryczne Zeszyty Problemowe Nr 3/2015 (107) 91 Two scenarios are chosen to prove the applicability of the IM exciter for power generation systems. First, a 185 ms 3-phase fault is simulated in the middle of one transmission line. At the beginning of the the system runs at rated operation and at the time of t = 0 s the switch S 1 is closed. After 185 ms the fault is cleared by opening the switch S 2. Following it is assumed that the fault is cleared and the switch S 2 recloses successfully. Secondly, the 3-phase fault is simulated once again. The switch S 1 is closed similar to the successful reclosing. After 185 ms the switch S 2 opens and the generator gets separated from the 3-phase fault. 37 periods or 740 ms after S 2 was opened, it closes again. In this case the generator is connected to the 3-phase fault once again. This second is called unsuccessful reclosing. The reclosing fault is cleared after additional 185 ms. For both scenarios it is assumed that the turbine torque keeps constant to simplify the comparison. The fast travel mode of the turbine valves may be activated at real power plants due to the fault, in order to reduce the overspeed of the shaft [9]. 3. Simulation and results 3.1 Successful reclosing Fig. 3 shows the most important generator values during the 3-phase fault on the transmission line. The values are expressed in the per unit system, which brings benefit to the comparability of the presented figures. Fig. 3. Most important generator values for both excitation systems during the successful reclosing

92 Maszyny Elektryczne Zeszyty Problemowe Nr 3/2015 (107) The generator operates under rated conditions at 3000 rpm. At the time of t = 0 s the switch S 1 is closed. The sudden short circuit leads to high transient generator currents. Since the turbine torque is constant during the whole, the generator starts to accelerate. Both excitation systems have no visible influence on the transient values during the short circuit. Generator currents and the air gap torque have the same behavior. After 185 ms the switch S 2 opens and the generator returns into rated operation. The recovery time for the rotor angle ϑ and the speed ω is similar. The generator field current i f shows a big difference. By using the IM exciter, the field current is about 1.5-2 pu greater than the field current with the static excitation system. The static excitation system offers the possibility to reverse the field voltage. The negative field voltage values lead to lower field current values after fault clearance. Thus, the oscillating air gap torque of the generator has lower amplitudes after fault clearance. Nevertheless, both excitation systems return the generator into rated operation within a time period of 3 seconds. The generator stator currents have the same maxima for both excitation systems. 3.2 Unsuccessful reclosing Fig. 4 shows the most important generator values for the unsuccessful reclosing. The generator runs at rated operation and at the time of t = 0 s the switch S 1 is closed. 185 ms after S 1 is closed, the switch S 2 opens. Fig. 4. Most important generator values for both excitation systems during the unsuccessful reclosing

Maszyny Elektryczne Zeszyty Problemowe Nr 3/2015 (107) 93 Compared to Fig. 3, all values are equivalent until the switch S 2 closes 37 time periods after the first fault clearance. S 1 is kept still closed during the whole. Hence, the generator gets connected to the 3-phase fault once again. The rotor angle ϑ and speed ω show higher oscillation amplitudes for the IM exciter. By using the speed ω as reference, the static excitation system is 500 ms faster in suppressing the oscillations. By using the rotor angle ϑ as reference value, both systems are at rated operation after 5 seconds. As noticed during the successful reclosing, the IM exciter leads to higher field current values after the first fault clearance. The generator s field current is at 3.5 pu with the static excitation system and at 4 pu with the IM exciter while S 2 is reclosing at the time of t = 1.12 s. Hence, the maximum value of the field current during the second fault is at 6.75 pu for the static excitation system and at 8 pu by using the IM exciter. The same effect is visible at the terminal currents. Nevertheless, both excitation systems help to return the generator into rated operation. There are visible differences, but both systems can totally suppress the shaft oscillations within 3 s after the second fault clearance. 4. Conclusions The IM exciter shows good regulation characteristics for the presented s. A disadvantage, which comes with all brushless excitation systems, is the lack of possibility to feed the field coil with negative field voltage values. Thus, the field current i f has higher values. This has a negative influence on the generator s air gap torque values and current amplitudes after an unsuccessful reclosing event. The settling times are comparable to the static excitation system ST1A. In order to build brushless excitation systems for turbine generators with the possibility to generate a field current at standstill, the IM exciter is an efficient way to combine fast regulation characteristics and the advantages of classical brushless excitation systems, where less servicing is required. 5. References [1] S. Schmuelling and S. Exnowski, "Start-up performance of very large synchronous generators," in 2013 Fourth International Conference on Power Engineering, Energy and Electrical Drives (POWERENG), May 2013, pp. 305 308. [2] D. Thien, "Effects and analysis of the altered operation of gasturbine power plants, [in German: Betriebsauswertung und Analysen zur veränderten Fahrweise Gasturbinengetriebener Fossiler Kraftwerke]," 8. Essener Tagung: Turbogeneratoren in Kraftwerken, Feb 2015. [3] "IEEE Standard Definitions for Excitation Systems for Synchronous Machines," IEEE Std 421.1-2007 (Revision of IEEE Std 421.1-1986), pp. 1 33, July 2007. [4] G. Klempner and I. Kerszenbaum, Operation and Maintenance of Large Turbo-Generators, ser. IEEE Press Series on Power Engineering. John Wiley and Sons, Inc., 2004. [5] L. Golebiowski, M. Golebiowski, and D. Mazur, "Inverters operation in rigid and autonomous grid," COMPEL - The international journal for computation and mathematics in electrical and electronic engineering, vol. 32, no. 4, pp. 1345 1357, 2013. [6] C. Ammann, K. Reichert, R. Joho, and Z. Posedel, "Shaft voltages in generators with static excitation systems-problems and solution," IEEE Transactions on Energy Conversion, vol. 3, no. 2, pp. 409 419, Jun 1988. [7] L. Golebiowski, M. Golebiowski, and D. Mazur, "Voltages in the shaft of the induction motor in 3d fem formulation, " in IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, 2007. SDEMPED 2007, Sept 2007, pp. 142 145. [8] "IEEE Recommended Practice for Excitation System Models for Power System Stability Studies," IEEE Std 421.5-2005 (Revision of IEEE Std 421.5-1992), 2006. [9] C. Kreischer, M. Rosendahl, Bennauer, and H. Werthes, "Dynamic behavior of steam turbine controller in the event of load rejection following a threephase short circuit close to the power plant," VGB Power Tech, vol. 91, pp. 77 79, May 2011. Authors Stefan Schmuelling and Dr.-Ing. Christian Kreischer are with the Chair of Energy Conversion, TU Dortmund University, Dortmund, 44227 Germany (phone: +49 231 755-2585; email: stefan.schmuelling@udo.edu, christian.kreischer@udo.edu) Marek Gołȩbiowski is with The Faculty of Electrical and Computer Engineering, Rzeszow University of Technology, Rzeszow (email: yegolebi@prz.edu.pl)