Phone: Fax: Web: -

Similar documents
TOTALINE PROTECTION CONTROLS

Application Engineering

Application Engineering

Part # Features & Applications Specifications Cross Reference

FLASHERS & TOWER LIGHTING CONTROLS

Power Controller. (see note 1) 10 sec

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

BF Series Flasher Thermal flasher circuitry

Model Number Structure

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

Model Number Structure

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES MV600

Low Signal Relay. To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12).

canfield connector 8510 Foxwood Court Youngstown, Ohio (330) Fax: (330)

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

HVACR Controls by ICM

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

Modulating Furnace Information. Warning on Meter Setting - Read First!

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

MERCURY CONTACTORS & RELAYS

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Series Motor Protection

OUTDOOR UNIT CONTROLLER (OUC)

Control Relays Overview

Model Pressure range ON/OFF output Linear output

Designed for ease of integration with automation systems

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

PBA Series Prelube Controls

C -5 to +55 (0.8 to 1.1Uc) Permissible o

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

ORSCO Lubrication Systems

Product discontinuation. Notices. Discontinuation Notice of Safety Relay and Socket. G7S series, P7S series. Wire connection

TOTALINE PROTECTION CONTROLS

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Submittal Data Information

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

VARNA Products 15 GPM (57 LPM) Prelube Kit for MTU 4000 Series Marine Engines

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Fincor Series 2230 MKII/2240

1. Take the cover off the relay, taking care to not shake or jar the relay or other relays around it.

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

48 Series - Contactor Relay 4PST - N.O. - Double Make, 15 Amp

HS Refrigeration Screw Compressor Troubleshooting Guidelines. SG March 2014

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Softstarters. Softstarters Power electronic brakes Type PEB

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

MIDDLE LOAD RELAY FOR SMART J/B

KD LV Motor Protection Relay

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

PD-Series Ground Fault Circuit Protection

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

ampcontrol s Hard rock relay range

Chapter 8. Understanding the rules detailed in the National Electrical Code is critical to the proper installation of motor control circuits.

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

PARTS & SERVICE MANUAL

22AF 40AF AF 150AF 225AF 400AF 800AF

EPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

G7S. Ordering Information. Plug-In Safety Relay. Safety Relay for Machine Control Conforms to EN Standard. H Suitable for safety circuits in press

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

Model Number Structure

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

PCB Relay. Contact form Terminal Single-side stable Single-winding latching

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Selection Guide Automotive Relays

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

COMPACT FLAT SIZE FOR AUTOMOTIVE

SURE TRIP RETRO KITS

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

209 Series. Magnetic Circuit Protectors

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

Thermal Overcurrent Circuit Breaker 3120-F...

LF Series At A Glance

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Application Note CTAN #127

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

TDX - Taco Duplex Starter with

COMPACT FLAT SIZE FOR AUTOMOTIVE

1 Form A 5A small size power relay for interface

MODEL RMS INSTALLATION INSTRUCTIONS. CONTENTS Page A. Introduction 1. Usage 2 2. How it operates 2

Transcription:

Timer - Delay-on-Make The TAC1 Series was designed to delay the operation of a compressor relay. It eliminates the possibility of relay chatter due to half-wave failure of the output. It connects in series with the load relay coil and provides a delay-on-make time delay each time input voltage is applied. It can be used for random start, anti-short cycling, sequencing, and many other applications. It is an excellent choice for all air conditioning and refrigeration equipment. Features TAC1 Series UL approved for air conditioning & refrigeration equipment Fixed or adjustable delays from 0.05-600s 24 to 230VAC Fail-safe design eliminates contactor chatter problems ±2% repeat accuracy Operation (Delay-on-Make): Upon application of input voltage, the time delay begins. The output is de-energized before and during the time delay. At the end of the time delay, the output energizes and remains energized until input voltage is removed. Reset: Removing input voltage resets the time delay and output. External ad just potentiometer: P/N: P1004- P/N: P1004-- Versa-knob: P/N: P0700-7 Plug-on adjustment module: P/N: VTP()() Load may be connected to terminals 3 or 1. R T is used when external adjustment is ordered. 1-0.05-3s 2-0.5-60s 3-2-180s 4-5-600s VTP P/N VTP4B VTP4F VTP4J VTP5N Selection Table for VTP Plug-on Adjustment Accessory. TAC1223 TAC1411 TAC141150 TAC1412 TAC1413 TAC14164 TAC1 Voltage 2-4 - 120VAC 6-230VAC Adjustment 1 - Fixed 2 - External adjust * 1-0.05-3s 2-0.5-60s 3-2 - 180s 4-5 - 600s *If fixed delay is selected, insert delay (0.05-600) in seconds. Type.... Analog circuitry Range.... 0.05-600s in 4 adjustable ranges or fixed Repeat Accuracy.... ±2% Tolerance (Factory Calibration).... ±20% Recycle Time.... 20ms after timing, during timing - 0.1% of time delay or 75ms, whichever is greater vs Temp. & Voltage.... ±10% Voltage................................. 24, 120, or 230VAC Tolerance.... ±20% AC Line Frequency.... 50/60 Hz Type.... Solid state Form.... NO, open during timing Rating.... 0.5A steady state, 10A inrush at 60 C Voltage Drop.... 120 & 230VAC: 4.2V @ 0.5A : 2.5V @ 0.5A Circuitry.... Encapsulated Dielectric Breakdown.... 2000V RMS terminals to mounting surface Insulation Resistance.... 100 MΩ Mounting... Surface mount with one #10 (M5 x 0.8) screw Dimensions.... 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) Termination.... 0.25 in. (6.35 mm) male quick connect terminals Operating / Storage Temperature.... -40 to 80 C / -40 to 85 C Humidity.... 95% relative, non-condensing Weight.... 2.4 oz (68 g)

Timer - Lockout T2D Series 1 Random Start Plus Lockout The T2D Series provides protection against short cycling of compressors and other motors. At the end of each operation, a lockout delay prevents restarting the compressor or motor until the delay is completed. models can be used with thermostats that include a cooling anticipator resistor. It can be connected in series with the load for delay-on-make operation. Operation (Lockout with Random Start): Connection #1: Upon application of input voltage, a random start time delay begins. At the end of this time delay, the output is energized. Lockout Delay: voltage must be applied prior to and during timing. When the thermostat or initiate switch opens, the output de-energizes and the lockout time delay begins. At the end of the lockout delay, the output is energized allowing the load to immediately energize when the initiate switch or thermostat closes. Connection #2: Upon application of input voltage and closure of initiate switch, the time delay begins. At the end of the time delay, the output is energized and remains energized until power is removed. Reset: Removing power resets the output and the time delay. Features: Lockout delay prevents rapid recycling of compressor Random start delay helps prevent low voltage starting Delay-on-make timer optional two terminal series connection Totally solid-state 1A output to 230VAC in 2 ranges T2D120A1150S T2D120A15M 2 Delay-on-Make L = Load S1 = Initiate Switch or Thermostat T2D Voltage 24A - 120A - 120/230VAC Adjustment 1 - Fixed 2 - External adjust * 1-1 - 100s 2-10 - 1000s 3-0.1-10m 4-1 - 100m Voltage................................., or 120/230VAC in 2 ranges Tolerance....±20% AC Line Frequency....50/60 Hz Minimum Load Current.... - 100mA; 120/230VAC - 40mA Rating....1A steady state, 10A inrush at 60 C Voltage Drop.... 2.5V @ 1A Initiate Time....After timing - 16ms Type....Analog circuitry Lockout & Random Start Delays....1s - 100m in 4 adjustable ranges or fixed Note: The lockout & random start delays are the same length. Tolerance....Adjustable: ±30%; factory fixed: ±30% Repeat Accuracy....±1% or 20ms, whichever is greater *If fixed delay is selected, insert delay (1-1000) followed by (S) sec. or (0.1-100) (M) min. Reset Time....After timing - 16ms; During timing - 200ms Dielectric Breakdown.... 2000V RMS terminals to mounting surface Insulation Resistance.... 100 MΩ Mounting....Surface mount with one #10 (M5 x 0.8) screw Dimensions....2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) Termination....0.25 in. (6.35 mm) male quick connect terminals Operating / Storage Temperature....-20 to 60 C / -40 to 85 C Humidity....95% relative, non-condensing Weight.... 2.4 oz (68 g) Cooling Anticipator ( Units Only) Minimum Cooling Anticipator.... 3,000 Ω

Timer - Bypass TAC4 Series The TAC4 is a bypass timer that provides a closure across the low-pressure switch during compressor startup. Its time-delay circuit is totally solid state including the normally closed output. The molded housing with encapsulation, the single hole mounting, and 0.25 in. (6.35 mm) termination makes the TAC4 easy to use, rugged, and reliable. Operation (Bypass Timer): (As shown in the connection & function diagrams) Upon application of input voltage and closure of controller contact, CC, the load, CR, energizes and the time delay begins. During the time delay, the TAC4 s solid-state output bypasses the LPC, low pressure cutout switch. This allows the compressor controlled by CR to start and establish acceptable pressure. At the end of the time delay, TAC4 s output de-energizes and remains de-energized until reset. The TAC4 may be used in other applications where a controlling contact must be bypassed for a specified period of time. Reset: Removing input voltage or opening CC resets the output and time delay. Features UL approved for air conditioning & refrigeration equipment Fixed or adjustable delays from 0.05-600s 24, 120 or 230VAC Fail-safe design eliminates contactor chatter problems ±2% repeat accuracy External ad just potentiometer: P/N: P1004-12 P/N: P1004-12- Versa-knob: P/N: P0700-7 Plug-on adjustment module: P/N: VTP()() LR = Lockout Relay OL = Overload or High Pressure Switch LPC = Low Pressure Cutout CR = Compressor Control Relay CC = Controller Contact R T is used when external adjustment is ordered. TAC42110 TAC441120 TAC4415 1-0.05-3s 2-0.5-60s 3-2-180s 4-5-300s VTP P/N VTP4B VTP4F VTP4J VTP5T Selection Table for VTP Plug-on Adjustment Accessory. TAC4 Voltage 2-4 - 120VAC 6-230VAC Adjustment 1 - Fixed 2 - External adjust * 1-0.05-3s 2-0.5-60s 3-2 - 180s 4-5 - 300s *If fixed delay is selected, insert delay (0.05-300) in seconds. Type.... Analog circuitry Range.... 0.05-300s in 4 adjustable ranges or fixed Repeat Accuracy.... ±2% Tolerance (Factory Calibration).... ±20% vs Temp. & Voltage.... ±10% Reset Time.... 150ms Voltage................................. 24, 120, or 230VAC Tolerance.... ±20% AC Line Frequency.... 50/60 Hz Type.... Solid state Form.... NC, closed during timing Rating.... 0.5A steady state, 10A inrush at 60 C Voltage Drop.... 120 & 230VAC 4.2V @ 0.5A 2.5V @ 0.5A Circuitry.... Encapsulated Dielectric Breakdown.... 2000V RMS terminals to mounting surface Insulation Resistance.... 100 MΩ Mounting.... Surface mount with one #10 (M5 x 0.8) screw Termination.... 0.25 in. (6.35 mm) male quick connect terminals Dimensions.... 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) Operating / Storage Temperature.... -40 to 75 C / -40 to 85 C Humidity.... 95% relative, non-condensing Weight.... 2.4 oz (68 g)

Timer - Lockout TA Series The TA Series prevents rapid recycling of a compressor. A lockout delay is started when the thermostat opens, or input voltage is lost. Eliminates tripped circuit breakers or blown fuses caused by a locked rotor during short cycling. The TA will not allow the compressor to start when the line voltage is low. Chatter of the compressor relay is eliminated. Because of the fast initiate time, bounce of the thermostat will not be transmitted to the compressor relay coil. A 30 second delay provides anti-reversing protection for scroll compressors. Features: Ideal for HVAC/R applications Lockout delay prevents rapid recycling of a compressor Low voltage brownout protection Circuitry to activate the cooling anticipator ( models) Eliminates nuisance service calls due to blown fuse or tripped breakers N Operation (Lockout): On initial closure of the S1, the compressor relay energizes immediately. When S1 opens or input voltage is interrupted, a lockout time delay is initiated. During this lockout time delay, the compressor relay cannot be energized. The low voltage (brownout) protection prevents energization of the compressor when the line voltage is low. Reset: The lockout time delay cannot be reset. After the time delay is completed, the unit automatically resets. TA12D2 TA24A0.5 TA24A3 TA24A5 TA24D0.5 TA24D2 S1 = Initiate Switch, Contact, or Thermostat CR = Compressor Relay (Load) CA = Optional Cooling Anticipator Voltage 12VDC 12VDC 30s 2m 3m 5m 1m 2m 30s 2m 3m 5m Part Number TA24A0.5 TA24A2 TA24A3 TA24A5 TA12D1 TA12D2 TA24D0.5 TA24D2 TA24D3 TA24D5 Voltage.............................. 12 or ; AC Line Frequency....50/60 Hz Impedance........................... 450 Ω (anticipator by-pass) Minimum Load Current....75mA Maximum Load Current....1A at 60 C Voltage Drop.... 1.25V Initiate Time.... 16ms Lockout Time....Fixed 0.5, 1, 2, 3, or 5m Tolerance....-15% - 35% Circuitry....Encapsulated Low Voltage.... 20V: /DC; 9V: 12VDC Dielectric Breakdown.... 2000V RMS terminals to mounting surface Insulation Resistance.... 100 MΩ Mounting....Surface mount with one #10 (M5 x 0.8) screw Dimensions....2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) Termination....0.25 in. (6.35 mm) male quick connect terminals Operating / Storage Temperature....-40 to 70 C / -40 to 85 C Humidity....95% relative, non-condensing Weight.... 2.4 oz (68 g) Thermostat Cooling Anticipator Resistor.... 1800 Ω

Timer - Lockout TL Series The TL Series provides protection against short cycling of a compressor. At the end of each operation, or whenever power is lost, a lockout delay is initiated. This lockout delay prevents restarting of the compressor until the head pressure has equalized. Compressor relay chatter due to thermostat bounce is eliminated by use of optional one second delay-on-make. The TL Series should not be used with cooling anticipator resistors or solid-state switches. (See the TA Series). Operation (Lockout): Lockout: On initial closure of S1, the compressor relay energizes immediately (or after an optional 1 s delay). When the S1 opens or input voltage is interrupted, the output opens and remains open for the lockout time delay. During this lockout time delay period, the compressor relay cannot be re-energized. Reset: The lockout time delay cannot be reset. After the time delay is completed, the unit automatically resets. Features Ideal for HVAC/R applications Lockout delay prevents short cycling of a compressor Optional 1s delay-on-make prevents contactor chatter Totally solid state and encapsulated to 230VAC in 3 ranges Eliminates nuisance service calls due to blown fuse or tripped breakers T20A5T TL230A5 TL230A5T TL24A5 S1 = Initiate Switch CR = Compressor or Control Relay TL Voltage 24A - 120A - 120VAC 230A - 230VAC Lockout Time 2-2m 3-3m 5-5m Delay-on-Make Blank - No delay T - 1s Voltage........................... 24, 120, or 230VAC AC Line Frequency.... 50/60 Hz Tolerance.... ±20% Minimum Load Current.... 40mA Maximum Load Current.... 1A @ ; 0.5A @ 120 & 230VAC at 60 C Inrush Current.... 10A at 60 C Voltage Drop.... - 2.5V @ 1A 120 & 230VAC - 4.2V @ 0.5A Initiate Time.... 8ms Lockout Time*.... Fixed 2, 3, or 5m Tolerance.... -15% - 35% Option.... 1s delay-on-make eliminates contactor chatter due to thermostat bounce Circuitry.... Encapsulated Dielectric Breakdown.... 2000V RMS terminals to mounting surface Insulation Resistance.... 100 MΩ Mounting.... Surface mount with one #10 (M5 x 0.8) screw Dimensions.... 2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) Termination.... 0.25 in. (6.35 mm) male quick connect terminals Operating / Storage Temperature... -40 to 70 C / -40 to 85 C Humidity.... 95% relative, non-condensing Weight.... 2.4 oz (68 g) *Power must be applied for at least 15 s to achieve a full lockout delay. Less than 15s will result in proportionally shorter delay periods. NOTE: Cooling anticipator resistor or leakage may cause erratic operation. See TA Series for use with systems that include anticipator resistors or use solid-state switches.

Timer - Delay-on-Make/Delay-on-Break CT Series N The CT Series combines a delay-on-make and delay-on-break time delay into one unit and may be used to control fan delays in heating and/or cooling equipment. The CT includes bypass circuitry to allow it to operate with cooling anticipators 3000 ohms. It is designed to operate in control circuits. Several CT modules may be combined to provide sequencing on of any number of loads and sequencing off of the same loads, such as electric heating elements. Operation (Delay-on-Make/Delay-on-Break): Forced Air Heating or Air Conditioning (as shown): When the thermostat closes, the compressor relay is immediately energized. At the end of a fixed delay-on-make delay (T1), the fan relay is energized. When the thermostat opens, the compressor relay is de-energized and the delayon-break delay is initiated. On completion of the fixed delay-on- break delay (T2) the fan relay is de-energized. If the thermostat is reclosed during the delay-on-break delay, the delay-on-break delay is reset and the fan relay remains energized. If the thermostat is closed when input voltage is applied, the delay-on-make delay (T1) begins as normal. Reset: Removing input voltage resets the output and time delays. Function: Delay-on-Make Delay-on-Break Features: Delay-on-make and delay-on-break in one unit Use for fan delays in heating or cooling equipment Use for multiple load sequencing operation Factory fixed delays from 1-600s in 1s increments CT1S12 CT1S30 CT1S300 CT1S45 CT1S8 CT1S90 CT30S1 CT45S45 CT5S300 CR = Compressor Relay THMS = Wall Thermostat R = Reset FS = Fan Switch FR = Fan Relay T1 = Delay-on-Make T2 = Delay-on-Break CT Delay-on-Make (fixed) Specify time in seconds from 1-600s followed by (S) Delay-on-Break (fixed) Specify time in seconds from 1-600s Type....Microcontroller Range....1-600s Repeat Accuracy....±5% Tolerance (Factory Calibration)....±20% Recycle Time... 300ms Voltage................................. Tolerance....±15% AC Line Frequency....50/60 Hz Type....Solid state Form....NO Rating....0.75A steady state, 5A inrush at 55 C Voltage Drop.... 1.25V Circuitry....Encapsulated Dielectric Breakdown.... 2000V RMS terminals to mounting surface Insulation Resistance.... 100 MΩ Mounting....Surface mount with one #10 (M5 x 0.8) screw Dimensions....2 x 2 x 1.21 in. (50.8 x 50.8 x 30.7 mm) Termination....0.25 in. (6.35 mm) male quick connect terminals Operating / Storage Temperature....-40 to 70 C / -40 to 85 C Humidity....95% relative, non-condensing Weight.... 2.4 oz (68 g) Thermostat....Anticipator Resistor: 3000 Ω