Brake Chopper BC BC 4.1. Instruction and Operation Manual

Similar documents
TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

EDB6032_G/GB Antriebstechnik. Operating Instructions. Brake chopper 6032/6033/6034

J1000 D E F I 1000 J1000 J1000 J1000 J1000

EPS/ELA-Series User Manual EPS/ELA 250W

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Operating manual UPS - System

Electronic Ballast EVG 2000-T

LV Capacitor CLMD03 Power Module Instruction manual

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

QS20.241, QS C1

Installation and Start-up Guide. ACS-BRK Brake Units

Hitachi America, Ltd.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

Braking Unit for Frequency Inverter Serie 3CV V 18,5 bis 55kW

J1000. Compact Inverter Series.

MODVAR Low voltage reactive power compensation modules Installation manual

INTELLIGENT FLANGE STRÖTER. Magnetic pulse generator

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

user's manual nx frequency converters brake resistors

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

Drive Technology \ Drive Automation \ System Integration \ Services. Data sheet. MOVIAXIS Multi-Axis Servo Inverter. Information regarding UL

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

Essential equipment for all your requirements

3 Internal Frequency Converter Operation 43

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

Braking Devices BR 230/ Assembly- and Commissioning Instructions

vacon nx ac drives brake resistors user manual

PowerOhm Installation Manual for BM R Series Braking Modules

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

HIB Enclosed Inverter User Guide

Operating Instructions

Low voltage AC drives. ABB component drives ACS to 2.2 kw / 0.25 to 3 hp Catalog

INDUSTRIAL POWER SUPPLIES SFL-SERIES

Operating Instructions. Angle Seat Control Valve. Type 7020

Commissioning Instructions Inbetriebnahme Anleitung VB 230/ L (LP)

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

SMD10 SMD11 SMD15 SMD30

TA-BL Instruction & Operating manual

DYNAMIC BRAKING (DB) OPTION

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

MICRO MASTER MICRO MASTER Vector MIDI MASTER Vector

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

PowerOhm Installation Manual for LG ATV Series Braking Modules

ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. Motor cable length 0.3 m. T [mm]

SMT-BM 20 A BMM 05 F BMM 05 AF

Question Number: 1. (a)

User Manual. Solar Charge Controller 3KW

CHARGING UNIT DEM 313

Installation Data. Allen-Bradley 1336/1336VT/1336 PLUS/PLUS II/IMPACT 1336 FORCE Drives Dynamic Braking

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

8BVE0500HW General information. 2 Order data 8BVE0500HW

BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE

SPEEDRIVE INSTRUCTIONS MANUAL

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

CDBR-B. Dynamic Braking Unit Instruction Manual. April 2009 Part Number: R1 Copyright 2009 Electromotive Systems

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

ABB machinery drives. Application guide Common DC system for ACS380 drives

TDBU Series Dynamic brake unit user manual

ACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor

.3 Section Waste Management and Disposal.

Welcome to the ABB Industrial Drives, ACS800 planning the installation training module. If you need help navigating this module, click the Help

User Manual Solar Charge Controller 3KW

Internet For latest information, PDF catalogs and operation manuals

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

TECHNICAL SERVICE MANUAL FOR MASTERTIG ACDC MACHINES

FUSES. Safety through quality

GE FANUC Parts. VersaPoint Power Terminal. Segment Terminal Fused, with Diagnostics 24VDC IC220PWR013. Features. Ordering Information

Model Number Structure

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

SINUS K 13. ACCESSORIES Braking resistors APPLICATION TABLES 78/160 INSTALLATION INSTRUCTIONS

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

CONTROL FEATURES AVAILABLE OPTIONS

IB IL 24 PWR IN/F-D IB IL 24 PWR IN/F-D-PAC

DBR3, 4500W, 9R, TS - BRAKING RESISTOR

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

Electronic tank monitoring device (complete kit) - for battery tanks - incl. overfill safety - after TRwS 791(-2) with clearance display

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

FR-BU2-1.5K to 55K FR-BU2-H7.5K to H280K

PowerOhm Installation Manual for BM R Series Braking Modules

Plug-in relays Mini ISO relays

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

HHD. High Voltage Fuses German DIN Standard. The temperature limiting function of the fuse striker pin. Design and construction.

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

LED control gear Compact fixed output

ACS800. Hardware Manual ACS Drives (5.5 to 110 kw) ACS800-U31 Drives (7.5 to 125 HP)

ABB Component Drives ACS150, 0.5 to 5 Hp

Installation Manual for DC Injection Brake Units

LV Capacitor Bank APC

Transcription:

Brake Chopper BC 2.1 - BC 4.1 Instruction and Operation Manual Caution: There is always a risk involved in the handling of electrical machinery! Therefore mounting and maintenance should only be done by authorized personnel. TAE Antriebstechnik GmbH Am Kappengraben 20 D-61273 Wehrheim Stand 24.02.2014 V-7 EBC2-1.PMD The German text applies in cases of doubt

About This Instruction Manual If you look for some definite topic you can use the table of contents at the beginning of these instruction and operation manual. In these instructions is a row of symbols which shall provide you with a fast orientation and show the importants. This symbol stands for notes and useful informations which shall make the operation easier for you. Note, disregard can damage or destruct the chopper. Note, disregard means a danger for the operator. 1. Instruction of Safety Before you put the chopper into operation, please read this instruction and operation manual completly. The operation should only be done by qualified personnel. The precautions and warnings below must be observed at the operation of the chopper. The braking chopper instruction and operation manual do not replace the manual of initial operation of the inverter. 1.1 Instructions and Rules During installation, general installation regulations such as following should be observed. DIN VDE 0100 VDE 0113 VDE 0160 VDE 0470 part 1 General requirements for the installation of power with mains General requirements for the installation of electrical equipment for production and tooling machines Requirements for electronic equipment for use in electrical power installations. International protection 2 Instruction and Operation Manual

1.2 Safety Caution Danger! Disconnect unit from mains and wait untill the capacitors have discharged before making any repairs. After the installation make sure that the unit and motor is properly grounded in order to avoid electrical hazzards. As with any form of electrical equipment, there is always a risk involved in the handling of electrical machinery. The greatest care must always be exercised during installation and maintenance. It is recommended that service is performed by authorized personnel only. Caution! 1. Do not connect or disconnect the chopper when it has power. 2. Please take care of the correct polarity. 3. If you exchange the connections + and - the inverter or the chopper can be destroyed. 4. An ultra rapid fuse for the protection of the IGBT is not installed. Table of content 1. Instruction of Safety... 2 1.1 Instructions and Rules... 2 1.2 Safety... 3 2. Function... 4 3. Mounting and Location... 4 4. Technical Data... 5 4.1 Chopper voltage 375V... 5 4.2 Chopper voltage 750V... 5 5. Load Curve... 6 6. Connections and Indications... 7 7. Example of Connection... 7 8. Dimensions... 8 9. Spare Parts... 8 10. Options... 9 10.1 Overcurrent relay... 9 10.2 Ultrafast semiconductor fuses... 9 11. Calculation Braking Chopper and Resistor... 9 12. Connection diagram option, ready for operation and chopper active...11 13. Connection diagram option Master - Slave... 12 Instruction and Operation Manual 3

2. Function If the speed of the motor is reduced the motor behaves like a generator. Since the kintical energy is not sent back with the Inverter to mains the intermediate circuit () capacitors store the energy. The voltage of the intermediate circuit increases. If the intermediate circuit voltage the inverter protects itself by turning off. To avoid the interuption of braking, a Braking Choppers is used. It is activated if the voltage of the intermediate circuit is higher than the tolerable intermediate circuit voltage. The braking resistor is connected with the intermediate circuit and the additional energy is transformed to heat. If big masses have to be decelerated the braking resistor must have enough power related to the kinetical energy. 3. Mounting and Location BC 2.1 BC 3.1 2 3 2 1 4 1 4 3 BC 4.1 2 5 1 4 (Hauptplatine - Mainboard) 3 type Position 1 2 3 4 5 BC 2.1-16/5,5 BC 2.1-24/6 BC 2.1-33/11 - BC 2.1-51/13 BC 3.1-32/13 - BC 3.1-32/22 1x BC 3.1-47/25 1x IGBT 2MBI Jumper Fan BC 3.1-65/27 B & Fuse F1 BC 3.1-67/26 Potentiometer PC- (only - P1 Board Electronic BC 3.1-67/45 Chopper not IGBT) 1x BC 3.1-97/52 voltage Fan BC 3.1-135/56 BC 4.1-90/33 BC 4.1-120/36 2x IGBT 2MBI BC 4.1-180/67 1x IGBT 2MBI BC 4.1-185/41 BC 4.1-250/75 BC 4.1-375/82 2x IGBT 2MBI 2x Fan Connection Voltage B 200-440V 450-800V Steckbrücke B - Jumper Chopper Voltage at potentiometer P1 at factory adjustment 375V 340V 750V 680V 4 Instruction and Operation Manual

4. Technical Data 4.1 Chopper voltage 375V Connection voltage 200-440 VDC +/- Chopper voltage Type Article-No. Factory adjustment Jumper B right:375v, B left: 340V Control range potentiometer P1: 240 to 440, cw:10v/turn lower Brake power in kva at Permanent load Permanent current Peak current Superfast fuse F2 Peak load in A in A in A >R min. BC 2.1-16/5,5 12262-0F01 5,5 16 15 45 50 8Ω BC 2.1-24/6 12262-1F01 6 24 17 68 63 5,3Ω BC 3.1-32/13 12263-AF01 13 32 35 90 100 4Ω BC 3.1-32/22 12263-0F01 22 32 60 90 100 4Ω BC 3.1-47/25 12263-1F01 25 47 70 130 125 2,8Ω BC 3.1-65/27 12263-2F01 27 65 75 180 200 2Ω BC 4.1-90/33 12264-0F01 33 90 90 240 250 1,6Ω BC 4.1-120/36 12264-1F01 36 120 100 330 355 1,1Ω BC 4.1-185/41 12264-2F01 41 185 110 500 500 0,75Ω Ambient temperature 0-40 C Dimensions refer to Chapter 8. 4.2 Chopper voltage 750V Connection voltage 450-800 VDC +/- Chopper voltage Type Article-No. Factory adjustment Jumper B right:750v, B left: 680V Control range potentiometer P1: 540 to 800, cw:25v/turn lower Brake power in kva at Permanent load Permanent current Peak current Superfast fuse F2 Peak load in A in A in A >R min. BC 2.1-33/11 12262-0F00 11 33 15 45 50 16Ω BC 2.1-51/13 12262-1F00 13 51 17 68 63 11Ω BC 3.1-67/26 12263-AF00 26 67 35 90 100 8,5Ω BC 3.1-67/45 12263-0F00 45 67 60 90 100 8,5Ω BC 3.1-97/52 12263-1F00 52 97 70 130 125 5,5Ω BC 3.1-135/56 12263-2F00 56 135 75 180 200 4,2Ω BC 4.1-180/67 12264-0F00 67 180 90 240 250 3,2Ω BC 4.1-250/75 12264-1F00 75 250 100 330 355 2,3Ω BC 4.1-375/82 12264-2F00 82 375 110 500 500 1,5Ω Ambient temperature 0-40 C Dimensions refer to Chapter 8. The value of the brake resistor has to be equal or higher than R min. and depends on the required output. If the brake resistor is lower than R min., the IGBT (Insulated Gate Bipolar Transistor) can be destroyed. The output is protected against short circuit but not against permanent overload. Instruction and Operation Manual 5

5. Load Curve at 40 C ambient temperature Peak Current in A 70 60 50 40 BC 2.1 BC 2.1-51/13 & BC 2.1-24/6 BC 2.1-33/11 & BC 2.1-16/5,5 30 20 5 10 30 60 120 Max. brakeing in seconds 200 150 120 100 60 0 Min. break in seconds Peak current in A 500 400 300 200 BC 4.1-375/82 & BC 4.1-185/41 BC 4.1-250/75 & BC 4.1-120/36 BC 3.1 & BC 4.1 150 BC 4.1-180/67 & BC 4.1-90/33 BC 3.1-135/56 & BC 3.1-65/27 100 50 25 1 2 3 4 5 Max. brakeing in minutes 5 BC 3.1-97/52 & BC 3.1-47/25 BC 3.1-67/45 & BC 3.1-32/22 BC 3.1-67/26 & BC 3.1-32/13 4 3 2 1 0 Min. break in minutes 6 Instruction and Operation Manual

6. Connections and Indications Indications: Overcurrent red Overcurrent/Short circuit Active clear Chopper is active Power green Chopper is ready Connections of the terminal blocks: Connection for earth ( ) Earth the cover large surfaced, e.g. mounting on a galvanized assembly plate. - -connection -voltage inverter +connection -voltage inverter - a thermo protection has to be connected in row to the brake resistor. This thermo protection has to be adjusted to the nominal current of the brake resistor. (see Chapter 7 Example of Connection) Caution! 1. Do not connect or disconnect the chopper when it has power. 2. Please take care of the correct polarity. 3. If you exchange the connections + and - the inverter or the chopper can be destroyed. 4. An ultra rapid fuse for the protection of the IGBT is not installed. 7. Example of Connection Inverter voltage - L1 L2 L3 + R R F2 Ultrafast Fuses (refer to Chapter 10 Options) Overload Relay (refer to Chapter 10 Options) Line Inverter If cables between inverter and chopper resp. chopper and brake resistor are less than 25 cm, they have to be twisted and if they are longer than 25 cm they have to be shielded. Instruction and Operation Manual 7

8. Dimensions B S H H1 R R B1 T Device size B B1 H H1 T S BC 2.1 82,5 40,5 150 138 220 6 BC 3.1 130 64,5 205 193 208 6 BC 4.1 131 64,5 298 280 300 9 9. Spare Parts Device type BC 2.1 BC 3.1 BC 4.1 Art.-No. Description 12262-0F.. 12262-1F.. 12263-AF.. 12263-0F.. 12263-1F.. 12263-2F.. 12264-0F.. 12264-1F.. 12264-2F.. 34292-42 IGBT 2MBI 50N-120 50A 34292-47 IGBT 2MBI 75N-120 75A 34292-52 IGBT 2MBI 100N-120 100A 34292-55 IGBT 2MBI 150N-120 150A 34292-62 IGBT 2MBI 200N-120 200A 34292-67 IGBT 2MBI 300N-120 300A 34472-00 F1 Fuse for electronic 30x5 medium blow 3,15A 68053-00 Fan 24V 78303-0F PC-Board 8 Instruction and Operation Manual

10. Options Chopper BC 2.1 - BC 4.1 s up to 60kW permanent load enclosure IP 20 and different types according to customer wishes. Please consult TAE Antriebstechnik. Overcurrent relays for protection of the brake resistor against thermal overstressing. Overcurrent relays with higher rated current of enquiry. 10.1 Overcurrent relay Rated current in A: Art.-No: 0,1-0,16 36770-A0 0,16-0,24 36770-B0 0,24-0,4 36770-C0 0,4-0,6 36770-D0 0,6-1 36770-E0 1-1,6 36770-F0 10.2 Ultrafast semiconductor fuses Rated current in A: Art.-No: 1,6-2,4 36770-G0 2,4-4 36770-H0 4-6 36770-I0 6-10 36770-K0 10-16 36770-L0 16-24 36770-M0 Use with Braking chopper: Fuse value in A Art.-No. Fuse Art.-No. Fuse Breaker 3pol 12262-0F... 50 34606-00 34529-00 12262-1F... 63 34607-00 34529-00 12263-AF... 100 34609-00 34529-00 12263-0F... 100 34609-00 34529-00 12263-1F... 125 34610-00 34529-00 12263-2F... 200 34621-00 34529-01 12264-0F... 250 34622-00 34529-01 12264-1F... 355 34633-00 34529-02 12264-2F... 500 on request 34529-03 11. Calculation Braking Chopper and Resistor Basis of calculation: Constant Brake torque and linear speed reduction. -1 n[min ] n max = 2400 min -1 n mittel =1200 min -1 0 t RUN = 14 s t BREAK= 3 s t OFF = 3 s t[s] M+ [Nm] 0 t[s] 100 Nm M- [Nm] P[kW] 0 25,1 kw M MAX P MAX BREAK t[s] Example: Brake torque 100 Nm Max Speed 2400 min -1 Motor operation time 14 sec. Brake time 3 sec. Stop 3 sec. Chopper voltage 750 V Instruction and Operation Manual 9

Calculation Peak Load P MAX BREAK P n = M 9550 2400 x 100 = 9550 MAX MAX MAX BREAK = 25,1 kw P MAX BREAK in kw peak load brake chopper n MAX in min -1 max speed M MAX in Nm max brake torque Calculation RMS Brake load P BREAK RMS P BREAK RMS = P MAX BREAK 3 = 25,1 ( t + t + t ) 3 ( + 3 + 3) RUN t BREAK BREAK OFF 3 14 = 5,6 kw P BREAK RMS in kw RMS brake load P MAX BREAK in kw peak load brake chopper t BREAK in seconds brake time t RUN in seconds motoring operation t BREAK in seconds regen operation t OFF in seconds stop Calculation Brake Resistor R = P U 2 MAX BREAK 2 750 = = 22,4 Ω 25100 R in W brake resistor U in V (turn-on) voltage P MAX BREAK in W peak load brake chopper Brake Chopper selected from table 4.2 (refer to technical data) Brake chopper BC2.1-33/11 Art.-No. 12262-0F00 Chopper voltage 750V Permanent Load: P BREAK RMS = 5,6 < 11 kw OK Peak Load: P MAX BREAK = 25,1 < 33 kw OK Brake Resistor: R = 22,4 > 16 W OK 10 Instruction and Operation Manual

12. Connection diagram option, ready for operation and chopper active C2/A2 Stör- und Betriebsbereitmeldung C1/A1 Chopper Aktiv, verzögert Aus C2/A2 message "error" and "ready for operation" C1/A1 Chopper active, delayed OFF C2 A2 C1 A1 Jumper - closed +24V Stör- und Betriebsbereitmeldung message "error" and "ready for operation" (+24V) Chopper Aktiv, verzögert Aus Chopper active, delayed OFF DIP-Switch S1 ON OFF 0 0 1 1 4 3 2 1 Logic Output C1 - A1 Chopper ON DIP OUT - ON OUT - OFF S1.1 ON S1.2 ON S1.3 ON S1.4 ON max 30mA max 30mA - -C2 A2 C1 A1- - Steckbrücke - Jumper Instruction and Operation Manual 11

13. Connection diagram option Master - Slave Achtung!!! Anschlüsse O,G,I,C führen 400VDC nach Erde! Caution!!! Connection O,G,I,C lead 400VDC to ground! Anschluss Variante 1: Master - Slave (in Reihe) - Connection version 1: Master - Slave (in series) MS - Master SL - Slave O G I C Output Ground Input Com Master RR Bremswiderstand Slave 1 RR Bremswiderstand Slave 2 RR Bremswiderstand Anschluss Variante 2: Master - Slave (Parallel) - Connection version 2: Master - Slave (parallel) (max 5 Slaves Parallel) MS - Master SL - Slave O G I C Output Ground Input Com Master RR Bremswiderstand Slave 1 RR Bremswiderstand Slave 2 RR Bremswiderstand 12 Instruction and Operation Manual