FX2N-2LC SPECIAL FUNCTION BLOCK

Similar documents
HARDWARE MANUAL. 1. Introduction. 2. Outline of Product. 3. Name of Each Part [MAIN UNIT INSTRUCTION MANUAL] JY992D88901B

POWER REGULATOR LD -40PSU

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

TOWA SEIDEN INDUSTRIAL CO., LTD.

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

Filterpack FR-BFP2-(H)0.4K to (H)15K

MULTI FUNCTIONAL COUNT CHECKER MODEL Poka Patrol CNA-4mk3

RP Instruction Manual

EVS RP6020. Instruction Manual

I. Safety precautions

AC CURRENT ANALOG CLAMP-ON TESTER MODEL MCL-350 INSTRUCTION MANUAL

Module Type Controller SRX Temperature Control Module [Basic Type] X-TIO-A Instruction Manual

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Stereo Power Amplifier

Differential Pressure Transmitter

TRANSISTORIZED INVERTER INSTRUCTION MANUAL HIGH-DUTY BRAKE RESISTOR FR-ABR(H)

MANUAL NO E1.2 Published in Dec.2004 Revised in Aug LF Series Linear Variable Differential Transformer INSTRUCTION MANUAL

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

MODEL 3567A. Digital MΩ Tester. Instruction Manual

Open Chassis Star-Delta Starter User Guide

Installation Manual. Remote Temperature Sensor KS9-BS1-A. Instructions for :- Remote Temperature Sensor

Clamp Earth Tester MET-2. Instruction Manual

Communications. Auxiliary. Functions. output. functions. Transistor. Heating or cooling control is selectable (See note 2.

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

Lumitester PD-20 Control Kit

B297SB-01-1K40. AnyWireASLINK System Product Guide. ASLINKSENSOR [Photo Interrupter type] -B297SB011K40 1/7- [Function] [Notes on Safety]

Analog Input Terminal

Air duct switching damper

Digital Temperature Controller

Micro-OPLC Installation Guide

AS4V DC ALARM BEFORE USE... CAUTION WARNING INSTRUCTION MANUAL AS4V MODEL. (dual or quad alarm trip; field-configurable)

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

THV-40SERIES. Power Controller. Single Phase Thyristor Unit (High Voltage Type) AC V. RoHS compliant

FX-1100 Series MASS BURETTE FLOW DETECTOR INSTRUCTION MANUAL ONO SOKKI CO., LTD.

DIGITAL CLAMP TESTER MODEL HCL-5000D

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

CAUTION. Disconnect Power

B-RAD Select USER MANUAL TABLE OF CONTENTS

MIZCON Plus Cooling Tower Controller Model R7010W

ROGOWSKI LEAK METER MODEL RLM-1

This section is specifically about safety matters

Assembly and Maintenance Manual Type ASNU

Extended Panel Operation Manual RKP001Z-0

VM-5 SERIES MONITOR MODEL VM-5Z3 POWER SUPPLY UNIT INSTRUCTION MANUAL

INSULATION RESISTANCE TESTER FOR PHOTOVOLTAIC SYSTEMS MSEI-200C INSTRUCTION MANUAL

OPERATING INSTRUCTION

Digital display Pressure range ON/OFF output Linear output Model

Maximum operating temperature for standard motors = 110 C. Shut down temperature in case of a malfunction = 115 C.

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

SDS Enclosed Star-Delta Starter User Guide

Direct Coupled Damper Actuator Model MY6050A1001

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

Models SPG5A and SPG6A

ACTIVAL Two-way Ball Valve with Threaded-end Connection

KSID MINI Split DC Inverter QUICK CONNECT Air Conditioner TROUBLESHOOTING KSID016-H215Q. Model Numbers:

Digital Flow Switch (Sensor Part) Operation Manual

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

Automatic Burnout Furnaces 115 to 230-volt Models OPERATOR S MANUAL

Relay Retrofit Program Cutting Tool Safety Guide

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Digital Temperature Controllers/ NX-series Temperature Control Unit

0.1 mm. Actuator Position Sensor. D-MP Series. Actuator stroke position is output with an analog signal. Repeatability IP67.

Hydraulic PTO Flow Device

1/16 DIN Temperature Controller E5CS

Pressure Transmitter

Sectional and Tilting Door Opener

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Technical Documentation

AZ Series Motor OPERATING MANUAL. Introduction. Safety precautions. CE Marking

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

A Member of the. Integrated Metering Technologies

362 Clamp Meter. Users Manual

User s Manual Power Supply IM E. 5th Edition

Galaxy VM. Battery Breaker Box Installation 09/

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

SHIMADEN SINGLE-PHASE THYRISTOR POWER REGULATOR

Read and understand this manual for safely usage.

TMD90A Dual Input Digital Thermometer

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

PrioVino Premier. Translation of Original Operating Instructions. Status: August First edition January 2018 / PrioVino GmbH

362 Clamp Meter. Users Manual

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

WPS600. Hydraulic Pressure Transducer. User s Guide. 600 bar 60 MPa 8700 psi

SUPPLEMENTAL RESTRAINT SYSTEM (SRS)

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

ION JET NOZZLE NIH-55

CPS Energy Balancer. Version: 1.0

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Transcription:

SPECIAL FUNION BLOCK USER S GUIDE JY992D8561E Cautions on Safety (Make sure to read this paragraph before using the unit.) Thoroughly read this manual, a separate USER S MANUAL and all attached documents of the connected programmable controller (hereafter referred to as "PLC") and other related units before starting installation, operation and inspection/maintenance of the temperature control block. Acquire the knowledge on equipment, the information on safety and all cautions before using the temperature control block. In this instruction manual, cautions on safety are classified as "WARNING" or "CAUTION". This symbol indicates that incorrect handling may generate a dangerous situation which may lead to death or serious injury. This symbol indicates that incorrect handling may generate a dangerous situation which may lead to medium or minor injury or physical damage. Even an item classified as "CAUTION" may lead to a severe result depending on the situation. Each item describes important information. Make sure to observe each item marked with "WARNING" or "CAUTION". Carefully store the instruction manual offered together with the temperature control block so that the operator can refer to it at any time necessary. Make sure to deliver the instruction manual to the end user. We appreciate it very much that you have purchased the temperature control block for Mitsubishi programmable controller. This manual describes handling of the MELSEC-F Series Temperature Control Block. Thoroughly read this manual and other manuals of related products, and sufficiently understand the specifications before use. Make sure to deliver this manual to the end user. Brand and product names described by/in this manual are trademarks or registered trademark of the irrespective ownes. Related Manuals When you using the for the first time, a separate USER S MANUAL is required. Make sure to obtain the USER S MANUAL from the dealer from which you have purchased the FX2N- 2LC, and safely use the. Manual name USER S MANUAL FX1N FX2N FX2NC FX3U Series User s Manual - Hardware Edition FX3UC Series User s Manual - Hardware Edition FX SERIES PROGRAMMING MANUAL ΙΙ FX3S/FX3G/FX3GC/FX3U/ FX3UC Series Programming Manual - Basic & Applied Instruction Edition Manual No. Supplied with product or separately supplied JY992D8561, installation of. JY992D8931 Supplied with product and installation of FX1N series PLC. JY992D6631 Supplied with product and installation of FX2N series PLC. JY992D641 Supplied with product and installation of FX2NC series PLC. JY99D1651 JY99D281 JY992D8811 JY99D1661 and installation of FX3U series PLC. and installation of FX3UC series PLC. Describes the instructions of FX1S/ FX1N/FX2N/FX2NC series PLC. This manual explains the installations of FX3S/FX3G/FX3GC/FX3U/FX3UC series PLC. If necessary, obtain them from the dealer from which you have purchased the.

1. Outline of Product Cautions on design Install a safety circuit outside the PLC so that the entire system conservatively operates even if an abnormality occurs in the external power supply or a failure occurs in the PLC. If the safety circuit is installed inside the PLC, malfunction and erroneous output may cause accidents. Make sure to construct an emergency stop circuit, protection circuit, interlock circuit to prevent damage to a machine or instrument outside the PLC. When the PLC or detects an abnormality such as a watch dog timer error or input value error by the self-diagnosis circuit, and all outputs turn off. When an abnormality occurs in the I/O control area which cannot be detected by the CPU in the PLC, output control may be disabled. Design external circuits and the structure so that the entire system conservatively operates in such cases. When a failure occurs in a relay, transistor, triac, etc. in the or output unit of PLC, outputs may keep ON or OFF. For output signals which may lead to severe accidents, design external circuits and the structure so that the entire system conservatively operates. Caution on disposal When disposing of the unit, treat it as industrial waste. The temperature control block (hereafter referred to as "temperature control block" or "") equipped with two temperature input points and two transistor (open collector) output points is a special block to control outputs of temperature inputs from thermocouples and platinum resistance thermometer bulbs by PID control. Connect the to the FX1N/FX2N/FX2NC/FX3U/FX3UC Series PLC. 1) As input sensors, two thermocouples, two platinum resistance thermometer bulbs or one thermocouple and one platinum resistance thermometer bulb are available. 2) Data can be read and written using FROM/TO instructions when the is connected to the FX1N/FX2N/FX2NC/FX3U/FX3UC Series PLC. (The performs arithmetic operation for PID control and output control. The PLC does not have to perform such control.) 3) Disconnection of heaters can be detected by current detection. 4) The proportional band, the integral time and the derivative time can be easily set by auto tuning. 5) Channels are isolated from each other. 2. Outside Dimension Φ Unit : mm (inch) Mass:.3kg Terminal screws M3 (.12) CH1 CH2 Terminal block 24+ COM 24- PTA PTA TC- TC+ TC- TC+

COM X2 X4 X1 X14 X16 L N 24+ X1 X3 X X13 X15 Y1 Y2 Y3 Y4 Y5 Y6 1 11 12 13 Y1 Y12 COM3 Y11 Y13 14 15 16 1 1 11 12 13 14 15 16 1 Y14 Y15 COM X X2 X4 X6 X X2 X4 X6 L N 24+ X1 X3 X5 X X1 X3 X5 X Y Y2 COM1 Y1 Y3 Y4 Y6 COM2 Y5 Y 1 Y Y2 COM3 Y1 Y3 2 3 4 5 6 Y4 Y6 COM4 Y5 Y 3. Installation Method Cautions on installation Use the unit in the environment for the general specifications described in the manual. Never use the unit in a place with dust, soot, conductive dust, corrosive gas or flammable gas, a place exposed to high temperature, dew condensation or rain and wind or a place exposed to vibration or impact. If the unit is used in such a place, electrical shock, fire, malfunction, damage in the product or deterioration of the product may be caused. Never drop cutting chips or electric wire chips into the ventilation window of the while drilling screw holes or wiring cables. Such chips may cause fire, failure or malfunction. After finishing installation, remove a dust preventing sheet adhered on the ventilation window of the PLC and the. If the sheet remains attached, fire, failure or malfunction may be caused. Securely connect connection cables such as extension cables and memory cassettes to specified connectors. Imperfect contact may cause malfunction. The can be installed on the right side of an FX1N/FX2N/FX2NC/FX3U/FX3UC Series PLC main unit or extension unit. The can be attached with a DIN rail DIN462 (width: 35 mm) or directly attached to a panel surface with screws (M4). 3.1 Installation on DIN rail Align the upper side of the DIN rail mounting groove of the with a DIN rail DIN462 (width: 35 mm) (➀), and push it on the DIN rail.(➁) When removing the, pull out downward the DIN rail mounting hook.(➂), and remove from DIN rail.(➃) When attached to DIN rail When removed from DIN rail 3.2 Direct installation on panel surface Screw-tighten the with M4 screws to a panel surface using two (upper and lower) mounting holes provided on the left side of the. Assure the interval of 1 to 2 mm between a unit or block installed on the left side of the. 4. Connection to PLC Main Unit Connect the to the PLC main unit with an extension cable. units are treated as special units of the PLC, and the special unit No. to is automatically assigned to each unit from the one nearest to the PLC main unit. *1 (These unit Nos. are used in FROM/TO instructions.) One unit occupies eight I/O points in the PLC main unit. For the details of I/O assignment in the PLC, refer to the manual of the PLC main unit. *1 Because the unit No. is assigned to the built-in CC-Link/LT master in the FX3UC-32MT-LT, unit numbers assigned to the begins with No.1. FX2N-32MR (X to X1) FX2N-4AD FX2N-32ER (X2 to X3) IN IN RUN BATT.V PROG.E FX2N-32MR OUT CPU.E FX2N-4AD OUT FX2N-32ER A/D (Y to Y1) Special block No. Special block No. 1 (Y2 to Y3) Special block No.2 Please check power supply specifications to decide the number of units that can be connected to the FX1N/FX2N/FX2NC/FX3U/FX3UC extension unit and PLC. To connect the unit to the FX2NC Series PLC, the interface FX2NC-CNV-IF is required. To connect the unit to the FX3UC Series PLC, the interface FX2NC-CNV-IF or FX3UC-1PS-5V is required. For extension, an extension cable FXN-65EC (65 mm) and the FX2N-CNV-BC sold separately are required. Only one FXN-65EC can be used in one system. ( ) indicates the I/O No.

5. Wiring Cautions on wiring Make sure to shut down the power supplies of all phases on the outside before starting installation or wiring. If the power supplies are not shut down, you may receive an electrical shock or the unit may be damaged. As to loads, such as a connector for normal rotation and a connector for reverse rotation, which are dangerous when turning on at the same time, make sure to interlock them outside the PLC in addition to interlocking of them in a program in the PLC. Correctly connect the power cable of the and the PLC as described in this manual. If the AC power supply is connected to a DC I/O terminal or DC power terminal, the PLC may be damaged. Perform Class D grounding with an electric wire of 2 mm 2 or more to the grounding terminal in the and the PLC. However, never perform common grounding with a strong power system. When a temperature sensor is a thermocouple AC power supply 24+ 24- *1 DC + - SSR *1 Connect the ground terminals of the unit and the main unit. Use class D grounding on the main unit. Use the compensating cable when you use the thermo couple. COM SSR /TC+ /TC- Thermocouple Heater /TC+ /TC- Thermocouple Heater When a temperature sensor is a resistance thermometer bulb /TC+ /TC- Resistance thermometer bulb The temperature sensor must use three line type. The resistance of the lead wire is a little, and use the wire rod without the resistance difference between three lines. Secure the termination using a tightening torque of.5 to.8n m 6. Specifications 6.1 General specifications Withstand voltage Specifications 5V AC for 1 minute (between analog input terminal and grounding terminal) Other General specifications are equivalent to those for the PLC main unit. Refer to the manual of the PLC main unit. 6.2 Power supply specifications Driving power supply Power supply for communication Current consumption Insulation method Number of occupied I/O points Specifications DC (-15% to +1% maximum), input from driving power supply terminal 5V DC (supplied from inside of PLC main unit) DC, 55 ma and 5V DC, ma Analog input area and PLC are insulated by photocoupler. Power supply and analog input are insulated by DC/DC converter. (Channels are insulated from each other.) 8 points in total (including input points and output points)

6.3 Performance specifications Control method Control operation period Set temperature range Heater disconnection detection Operation mode Self-diagnosis function Memory Indication 6.4 Input specifications Two-position control, PID control (with auto tuning function), PI control 5ms Equivalent to input range Alarm is detected by buffer memory (Variable within range from. to 1. A.). : Measured value monitor 1: Measured value monitor + Temperature alarm 2: Measured value monitor + Temperature alarm + Control (selected by buffer memory) Adjustment data check, input value check, watch dog timer check. Built-in EEPROM (Number of times of overwrite: 1, times) Lit (green): While 5V power is supplied Extinguished: While 5V power is not supplied Lit (red): While power is supplied Extinguished: While power is not supplied Lit (red): While control output 1 is ON Extinguished: While control output 1 is OFF Lit (red): While control output 2 is ON Extinguished: While control output 2 is OFF Temperature input input Number of input points Input type Thermocouple K, J, R, S, E, T, B, N, PLII, WRe5-26, U, L, JIS C 162-1995 Resistance thermometer bulb 3-wire Pt1 JIS C 164-199, JPt1 JIS C 164-1981 Measurement precision Cold contact temperature compensation error Resolution Sampling period Effect of external resistance Input impedance Sensor current Allowable input lead wire resistance Operation when input is disconnected Operation when input is short-circuited Number of inputs Current detector Heater current measurement value Measurement precision Sampling period Ambient temperature 23 C ± 5 C : ±.3% of range span ± 1 digit. Ambient temperature C to 55 C : ±.% of range span ± 1 digit. However, to 399 C ( to 99 F) in B inputs as well as to 32 F in PLII and WRe5-26 inputs are outside precision guarantee range. Within ±1. C However, within ± 2. C while input value is -15 to -1 C within ± 3. C while input value is -2 to -15 C.1 C (.1 F) or 1 C(1 F) (Varies depending on input range of used sensors.) 5ms Approx..35 μv/ω 1 MΩ or more Approx..3 ma 1 Ω or less Upscale Downscale L-12-S36-8 or L-6-P-H (manufactured by U.R.D. Co., Ltd.) When L-12 is used: to 1A When L-6 is used: to 3A Larger one between ± 5% of input value and 2 A (excluding precision of current detector) 1 second 6.5 Sensor type K J R S -1. to 4. C -1 to 13 C -1 to 8 F -1 to 24 F -1. to 4. C -1. to 8. C -1 to 12 C -1 to 16 F -1 to 21 F to 1 C to 32 F to 1 C to 32 F Sensor type E T B N to 1 C to 18 F -2. to 4. C. to 4. C -3. to 4. F -3. to. F. to. F to 18 C to 3 F to 13 C to 23 F

Sensor type PLII WRe5-26 U L to 12 C to 23 F to 23 C to 3 F -2. to 6. C -3. to. F. to 9. C to 16 F Sensor type JPt1 Pt1 When B is used, to 399 C ( to 99 F) is outside the precision guarantee range. When PLII is used, to 32 F is outside the precision guarantee range. When WRe5-26 is used, to 32 F is outside the precision guarantee range. 6.6 Output specifications -5. to 15. C -2. to 5. C -3. to 3. F -3 to 9 F -5. to 15. C -2. to 6. C -3. to 3. F -3 to 11 F Number of output points Output method Rated load voltage Maximum load voltage Maximum load current Leak current in OFF status Maximum voltage drop in ON status Control output cycle Open collector transistor output 5 to DC 3V DC or less 1mA.1 ma or less 2.5V (maximum) or 1.V (typical) at 1 ma 3 seconds (Variable within range from 1 to 1 seconds) Guidelines for the safety of the user and protection of the This manual has been written to be used by trained and competent personnel. This is defined by the European directives for machinery, low voltage and EMC. If in doubt at any stage during the installation of the always consult a professional electrical engineer who is qualified and trained to the local and national standards. If in doubt about the operation or use of the please consult the nearest Mitsubishi Electric distributor. Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment. All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples. Owing to the very great variety in possible application of this equipment, you must satisfy yourself as to its suitability for your specific application. This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual. Manual number : JY992D8561 Manual revision : E Date : April 215 HEAD OFFICE : TOKYO BUILDING, 2--3 MARUNOUCHI, CHIYODA-KU, TOKYO 1-831, JAPAN JY992D8561E Effective April 215 Specifications are subject to change without notice

COM X2 X4 X1 X14 X16 L N 24+ X1 X3 X X13 X15 Y1 Y2 Y3 Y4 Y5 Y6 1 11 12 13 Y1 Y12 COM3 Y11 Y13 14 15 16 1 1 11 12 13 14 15 16 1 Y14 Y15 COM X X2 X4 X6 X X2 X4 X6 L N 24+ X1 X3 X5 X X1 X3 X5 X Y Y2 COM1 Y1 Y3 Y4 Y6 COM2 Y5 Y 1 Y Y2 COM3 Y1 Y3 2 3 4 5 6 Y4 Y6 COM4 Y5 Y SPECIAL FUNION BLOCK USER S GUIDE JY992D8561E Cautions on Safety (Make sure to read this paragraph before using the unit.) Thoroughly read this manual, a separate USER S MANUAL and all attached documents of the connected programmable controller (hereafter referred to as "PLC") and other related units before starting installation, operation and inspection/maintenance of the temperature control block. Acquire the knowledge on equipment, the information on safety and all cautions before using the temperature control block. In this instruction manual, cautions on safety are classified as "WARNING" or "CAUTION". This symbol indicates that incorrect handling may generate a dangerous situation which may lead to death or serious injury. This symbol indicates that incorrect handling may generate a dangerous situation which may lead to medium or minor injury or physical damage. Even an item classified as "CAUTION" may lead to a severe result depending on the situation. Each item describes important information. Make sure to observe each item marked with "WARNING" or "CAUTION". Carefully store the instruction manual offered together with the temperature control block so that the operator can refer to it at any time necessary. Make sure to deliver the instruction manual to the end user. We appreciate it very much that you have purchased the temperature control block for Mitsubishi programmable controller. This manual describes handling of the MELSEC-F Series Temperature Control Block. Thoroughly read this manual and other manuals of related products, and sufficiently understand the specifications before use. Make sure to deliver this manual to the end user. Brand and product names described by/in this manual are trademarks or registered trademark of the irrespective ownes. Related Manuals When you using the for the first time, a separate USER S MANUAL is required. Make sure to obtain the USER S MANUAL from the dealer from which you have purchased the FX2N- 2LC, and safely use the. Manual name USER S MANUAL FX1N FX2N FX2NC FX3U Series User s Manual - Hardware Edition FX3UC Series User s Manual - Hardware Edition FX SERIES PROGRAMMING MANUAL ΙΙ FX3S/FX3G/FX3GC/FX3U/ FX3UC Series Programming Manual - Basic & Applied Instruction Edition Manual No. Supplied with product or separately supplied JY992D8561, installation of. JY992D8931 Supplied with product and installation of FX1N series PLC. JY992D6631 Supplied with product and installation of FX2N series PLC. JY992D641 Supplied with product and installation of FX2NC series PLC. JY99D1651 JY99D281 JY992D8811 JY99D1661 and installation of FX3U series PLC. and installation of FX3UC series PLC. Describes the instructions of FX1S/ FX1N/FX2N/FX2NC series PLC. This manual explains the installations of FX3S/FX3G/FX3GC/FX3U/FX3UC series PLC. If necessary, obtain them from the dealer from which you have purchased the. 1. Outline of Product Cautions on design Install a safety circuit outside the PLC so that the entire system conservatively operates even if an abnormality occurs in the external power supply or a failure occurs in the PLC. If the safety circuit is installed inside the PLC, malfunction and erroneous output may cause accidents. Make sure to construct an emergency stop circuit, protection circuit, interlock circuit to prevent damage to a machine or instrument outside the PLC. When the PLC or detects an abnormality such as a watch dog timer error or input value error by the self-diagnosis circuit, and all outputs turn off. When an abnormality occurs in the I/O control area which cannot be detected by the CPU in the PLC, output control may be disabled. Design external circuits and the structure so that the entire system conservatively operates in such cases. When a failure occurs in a relay, transistor, triac, etc. in the or output unit of PLC, outputs may keep ON or OFF. For output signals which may lead to severe accidents, design external circuits and the structure so that the entire system conservatively operates. Caution on disposal When disposing of the unit, treat it as industrial waste. The temperature control block (hereafter referred to as "temperature control block" or "") equipped with two temperature input points and two transistor (open collector) output points is a special block to control outputs of temperature inputs from thermocouples and platinum resistance thermometer bulbs by PID control. Connect the to the FX1N/FX2N/FX2NC/FX3U/FX3UC Series PLC. 1) As input sensors, two thermocouples, two platinum resistance thermometer bulbs or one thermocouple and one platinum resistance thermometer bulb are available. 2) Data can be read and written using FROM/TO instructions when the is connected to the FX1N/FX2N/FX2NC/FX3U/FX3UC Series PLC. (The performs arithmetic operation for PID control and output control. The PLC does not have to perform such control.) 3) Disconnection of heaters can be detected by current detection. 4) The proportional band, the integral time and the derivative time can be easily set by auto tuning. 5) Channels are isolated from each other. 2. Outside Dimension Φ Unit : mm (inch) Mass:.3kg Terminal screws M3 (.12) CH1 CH2 Terminal block 24+ COM 24- PTA PTA TC- TC+ TC- TC+ 3. Installation Method Cautions on installation Use the unit in the environment for the general specifications described in the manual. Never use the unit in a place with dust, soot, conductive dust, corrosive gas or flammable gas, a place exposed to high temperature, dew condensation or rain and wind or a place exposed to vibration or impact. If the unit is used in such a place, electrical shock, fire, malfunction, damage in the product or deterioration of the product may be caused. Never drop cutting chips or electric wire chips into the ventilation window of the while drilling screw holes or wiring cables. Such chips may cause fire, failure or malfunction. After finishing installation, remove a dust preventing sheet adhered on the ventilation window of the PLC and the. If the sheet remains attached, fire, failure or malfunction may be caused. Securely connect connection cables such as extension cables and memory cassettes to specified connectors. Imperfect contact may cause malfunction. The can be installed on the right side of an FX1N/FX2N/FX2NC/FX3U/FX3UC Series PLC main unit or extension unit. The can be attached with a DIN rail DIN462 (width: 35 mm) or directly attached to a panel surface with screws (M4). 3.1 Installation on DIN rail Align the upper side of the DIN rail mounting groove of the with a DIN rail DIN462 (width: 35 mm) (➀), and push it on the DIN rail.(➁) When removing the, pull out downward the DIN rail mounting hook.(➂), and remove from DIN rail.(➃) When attached to DIN rail When removed from DIN rail 3.2 Direct installation on panel surface Screw-tighten the with M4 screws to a panel surface using two (upper and lower) mounting holes provided on the left side of the. Assure the interval of 1 to 2 mm between a unit or block installed on the left side of the. 4. Connection to PLC Main Unit Connect the to the PLC main unit with an extension cable. units are treated as special units of the PLC, and the special unit No. to is automatically assigned to each unit from the one nearest to the PLC main unit. *1 (These unit Nos. are used in FROM/TO instructions.) One unit occupies eight I/O points in the PLC main unit. For the details of I/O assignment in the PLC, refer to the manual of the PLC main unit. *1 Because the unit No. is assigned to the built-in CC-Link/LT master in the FX3UC-32MT-LT, unit numbers assigned to the begins with No.1. FX2N-32MR (X to X1) FX2N-4AD FX2N-32MR Please check power supply specifications to decide the number of units that can be connected to the FX1N/FX2N/FX2NC/FX3U/FX3UC extension unit and PLC. To connect the unit to the FX2NC Series PLC, the interface FX2NC-CNV-IF is required. To connect the unit to the FX3UC Series PLC, the interface FX2NC-CNV-IF or FX3UC-1PS-5V is required. For extension, an extension cable FXN-65EC (65 mm) and the FX2N-CNV-BC sold separately are required. Only one FXN-65EC can be used in one system. ( ) indicates the I/O No. IN OUT FX2N-4AD (Y to Y1) Special block No. RUN BATT.V PROG.E CPU.E A/D Special block No. 1 OUT FX2N-32ER FX2N-32ER (X2 to X3) (Y2 to Y3) IN Special block No.2

5. Wiring Cautions on wiring Make sure to shut down the power supplies of all phases on the outside before starting installation or wiring. If the power supplies are not shut down, you may receive an electrical shock or the unit may be damaged. As to loads, such as a connector for normal rotation and a connector for reverse rotation, which are dangerous when turning on at the same time, make sure to interlock them outside the PLC in addition to interlocking of them in a program in the PLC. Correctly connect the power cable of the and the PLC as described in this manual. If the AC power supply is connected to a DC I/O terminal or DC power terminal, the PLC may be damaged. Perform Class D grounding with an electric wire of 2 mm 2 or more to the grounding terminal in the and the PLC. However, never perform common grounding with a strong power system. When a temperature sensor is a thermocouple /TC+ 6. Specifications 6.1 General specifications Withstand voltage Specifications 5V AC for 1 minute (between analog input terminal and grounding terminal) Other General specifications are equivalent to those for the PLC main unit. Refer to the manual of the PLC main unit. 6.2 Power supply specifications Driving power supply Power supply for communication Current consumption Insulation method 24+ COM /TC+ /TC+ Number of occupied I/O points *1 DC + - SSR SSR Thermocouple Heater Thermocouple Resistance thermometer bulb AC power supply Heater When a temperature sensor is a resistance thermometer bulb Specifications DC (-15% to +1% maximum), input from driving power supply terminal 5V DC (supplied from inside of PLC main unit) DC, 55 ma and 5V DC, ma Analog input area and PLC are insulated by photocoupler. Power supply and analog input are insulated by DC/DC converter. (Channels are insulated from each other.) 8 points in total (including input points and output points) *1 Connect the ground terminals of the unit and the main unit. Use class D grounding on the main unit. Use the compensating cable when you use the thermo couple. The temperature sensor must use three line type. The resistance of the lead wire is a little, and use the wire rod without the resistance difference between three lines. Secure the termination using a tightening torque of.5 to.8n m 6.3 Performance specifications Control method Control operation period Set temperature range Heater disconnection detection Operation mode Self-diagnosis function Memory Indication 6.4 Input specifications /TC- 24- /TC- /TC- Temperature input input 6.5 Two-position control, PID control (with auto tuning function), PI control 5ms Equivalent to input range Alarm is detected by buffer memory (Variable within range from. to 1. A.). : Measured value monitor 1: Measured value monitor + Temperature alarm 2: Measured value monitor + Temperature alarm + Control (selected by buffer memory) Adjustment data check, input value check, watch dog timer check. Built-in EEPROM (Number of times of overwrite: 1, times) Lit (green): While 5V power is supplied Extinguished: While 5V power is not supplied Lit (red): While power is supplied Extinguished: While power is not supplied Lit (red): While control output 1 is ON Extinguished: While control output 1 is OFF Lit (red): While control output 2 is ON Extinguished: While control output 2 is OFF Number of input points Input type Thermocouple K, J, R, S, E, T, B, N, PLII, WRe5-26, U, L, JIS C 162-1995 Resistance thermometer bulb 3-wire Pt1 JIS C 164-199, JPt1 JIS C 164-1981 Measurement precision Cold contact temperature compensation error Resolution Sampling period Effect of external resistance Input impedance Sensor current Allowable input lead wire resistance Operation when input is disconnected Operation when input is short-circuited Number of inputs Current detector Heater current measurement value Measurement precision Sampling period Ambient temperature 23 C ± 5 C : ±.3% of range span ± 1 digit. Ambient temperature C to 55 C : ±.% of range span ± 1 digit. However, to 399 C ( to 99 F) in B inputs as well as to 32 F in PLII and WRe5-26 inputs are outside precision guarantee range. Within ±1. C However, within ± 2. C while input value is -15 to -1 C within ± 3. C while input value is -2 to -15 C.1 C (.1 F) or 1 C(1 F) (Varies depending on input range of used sensors.) 5ms Approx..35 μv/ω 1 MΩ or more Approx..3 ma 1 Ω or less Upscale Downscale L-12-S36-8 or L-6-P-H (manufactured by U.R.D. Co., Ltd.) When L-12 is used: to 1A When L-6 is used: to 3A Larger one between ± 5% of input value and 2 A (excluding precision of current detector) 1 second Sensor type K J R S -1. to 4. C -1 to 13 C -1 to 8 F -1 to 24 F -1. to 4. C -1. to 8. C -1 to 12 C -1 to 16 F -1 to 21 F to 1 C to 32 F to 1 C to 32 F Sensor type E T B N to 1 C to 18 F -2. to 4. C. to 4. C -3. to 4. F -3. to. F. to. F to 18 C to 3 F to 13 C to 23 F Sensor type PLII WRe5-26 U L When B is used, to 399 C ( to 99 F) is outside the precision guarantee range. When PLII is used, to 32 F is outside the precision guarantee range. When WRe5-26 is used, to 32 F is outside the precision guarantee range. 6.6 Output specifications This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual. HEAD OFFICE to 12 C to 23 F to 23 C to 3 F Sensor type JPt1 Pt1-5. to 15. C -2. to 5. C -3. to 3. F -3 to 9 F Number of output points Output method Rated load voltage Maximum load voltage Maximum load current Leak current in OFF status Maximum voltage drop in ON status Control output cycle -5. to 15. C -2. to 6. C -3. to 3. F -3 to 11 F -2. to 6. C -3. to. F : TOKYO BUILDING, 2--3 MARUNOUCHI, CHIYODA-KU, TOKYO 1-831, JAPAN. to 9. C to 16 F Open collector transistor output 5 to DC 3V DC or less 1mA.1 ma or less 2.5V (maximum) or 1.V (typical) at 1 ma 3 seconds (Variable within range from 1 to 1 seconds) Guidelines for the safety of the user and protection of the This manual has been written to be used by trained and competent personnel. This is defined by the European directives for machinery, low voltage and EMC. If in doubt at any stage during the installation of the always consult a professional electrical engineer who is qualified and trained to the local and national standards. If in doubt about the operation or use of the please consult the nearest Mitsubishi Electric distributor. Under no circumstances will Mitsubishi Electric be liable or responsible for any consequential damage that may arise as a result of the installation or use of this equipment. All examples and diagrams shown in this manual are intended only as an aid to understanding the text, not to guarantee operation. Mitsubishi Electric will accept no responsibility for actual use of the product based on these illustrative examples. Owing to the very great variety in possible application of this equipment, you must satisfy yourself as to its suitability for your specific application. JY992D8561E Manual number : JY992D8561 Manual revision : E Date : April 215 Effective April 215 Specifications are subject to change without notice