P78 Series Controls for Dual Pressure Applications

Similar documents
P78 Series Controls for Dual Pressure and Hazardous Location Applications

M9300 Series Switch Kits

P70, P72, and P170 Series Controls for High Pressure Applications

M9300 Series Potentiometer Kits

CSD Series Current Devices Split Core

M9109-GGx-5 Series Proportional Electric Non-spring Return Actuators

M9106-GGx-4 Series Proportional Electric Non-Spring Return Actuators

M9109-GGx-4 Series Proportional Electric Non-Spring Return Actuators

VA-4233-AGx Series Electric Valve Actuators

System 350 S350C Temperature Slave Stage Module

P70, P72 and P170 Series Controls for High Pressure Applications

M9109 Series Electric Non-spring Return Actuators

P545 Series Electronic Lube Oil Control

VA9905 Actuator and VG1600 Series Six-Way Valves

VA9104-xGA-3S Series Electric Non-Spring Return Valve Actuators

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

M9106-AGx-2N0x Series Electric Non-Spring Return Actuators

M9203-Bxx-2(Z) Series On/Off Electric Spring Return Actuators

M9102-AGA-3S and M9104-xGA-3S Series Electric Non-Spring Return Actuators

M Remote Mounting Kit

M9106-xGx-2 Series Electric Non-Spring Return Actuators

P70, P72, and P170 Controls for Low Pressure Applications

VA-4233-GGx Series Electric Valve Actuators

TE-6100 Series Temperature Sensors and Completed Sensor/Hardware Assemblies

M Remote Mounting Kit

M9104-AGP-2S Series Electric Non-Spring Return Actuator with Pressure Sensor for VAV Applications Part No , Rev. B

System 350 A350E Electronic Cooling Control

Fan Relay Board (FRBii) Assembly

TM-11x1 Series Room Temperature Module

M9203-AGx-2(Z) Series On/Off and Floating Point Electric Spring Return Actuators

M x Series Valve Linkage Kits

M9208-Bxx-3 Series On/Off Electric Spring Return Actuators

Two Flashes. N/A for AboveAir Units / Witt Condenser use 75 psig (set with switches 64, 8, 2, & 1 set to ON )

M9300 Series Electric Non-Spring Return Actuators

M9102-AGA-2S and M9104-xGA-2S Series Electric Non-Spring Return Actuators

M9220-AGx-3 Floating Electric Spring Return Actuators

System 350 A350R Electronic Temperature Reset Control (with Relay)

V-2410 Three-Way Multipurpose Solenoid Air Valve

M9220-Bxx-3 On/Off Electric Spring Return Actuators

Applications. A421 Series Standard Electronic Temperature Controls Installation Guide

F261 Series Fluid Flow Switches

A25 Series Warm Air Control with Manual Reset

A11 Series Low Temperature Cutout Control

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

V46 and V47. Repair Parts and Service Instructions. Applications. Adjustments. Installation Guidelines

Installation Instructions. Applications. Installation. Part No , Rev. Issued May 9, 2011

DPT-2015 Differential Pressure Transmitter for VAV Box Applications

VA-720x Electric Valve Actuator

M9220-xxx-3 Electric Spring Return Actuators

VA-7450 Series. Electric Valve Actuators

P445 Series Electronic Lube Oil Control

INSTALLATION DATA ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

System 350 P352AB Electronic Pressure Control Series

INSTALLATION DATA ETC SINGLE STAGE ELECTRONIC TEMPERATURE CONTROL

P70 Series MICRO-SET TM Pressure Controls for Refrigeration and Air Conditioning, 4-Wire, 2-Circuit Contact Block

M9000-3xx Series Weather Shield Enclosures

V-9502 Series Pneumatic Valve Actuator Positioners

M9116, M9124, and M9132 Series Electric Non-spring Return Actuators

PRODUCT DESCRIPTION SPECIFICATIONS

INSTALLATION DATA ETC SINGLE Stage

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

Installation Instructions

VA-715x Electric Valve Actuator

RA-2000 Airflow Measuring System

TE-6001 Hardware Assemblies for TE-6000 Temperature Elements

M9220-HGx-3 Proportional Electric Spring Return Actuators

M Valve Actuator Weather Shield Kit

Series P28. Oil Protection Controls. Feature and Benefits. P28DP Oil Protection Control (P) Setpoint adjusting cam

F61 Series Standard Flow Switches

M9206-Bxx-2S Series On/Off Electric Spring Return Actuators

Specification Grade Contemporary Wall Mount/Technical Installation Data

A419ABG-3C Electronic Temperature Control

Series P100AP and P100CP Encapsulated Pressure Control. Auto-reset Standard Duty. Feature and Benefits

P66 Series Electronic Fan Speed Controls

VSD Series II Variable Speed Micro Drives

RPM1600 Series Room Pressure Monitors

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Series P74 Differential Pressure Controls, without time delay

Pressure Control Type KPU

Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

A419 Series Electronic Temperature Controls with NEMA 1 or NEMA 4X Watertight Enclosures

AD-1250 Airflow Measuring Station

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

VA9208-Bxx-x Series On/Off Electric Spring Return Valve Actuators

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

MOONRING 1.5 MOONRING 3

LAL SERIES LED LUMINAIRE

Series P215PR Direct Mount Pressure Actuated Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

VA2202-xxx-2 Series Electric Spring Return Valve Actuators

I ntroduction. N ote. Series P74 Differential Pressure Controls, without time delay. Feature and Benefits

Installation Instructions

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

CSR COMPACT FUSED INTERLOCKED ARKTITE RECEPTACLE - 30 & 60 AMP Installation & Maintenance Information IF 1440

VA9104-xGA-1S Series Electric Non-Spring Return Valve Actuators

M9210-xxx-3 Electric Spring Return Actuators

Captivate Illuminated Mirror Light

VA9104-xGA-2S Series Electric Non-Spring Return Valve Actuators

VA9203-AGx-2Z Series On/Off and Floating Point Electric Spring Return Valve Actuators

Transcription:

P78 Series Controls for Dual Pressure Applications Installation Instructions P78LCA, P78MCA Part No. 24-7664-3183, Rev. Issued November 2016 Applications Refer to the QuickLIT website for the most up-to-date version of this document. P78 Series Controls for Dual Pressure Applications provide combined high and low pressure control of compressors on commercial refrigeration and air-conditioning applications. IMPORTANT: Use this P78 Series Control only as an operating control. Where failure or malfunction of the control could lead to personal injury or property damage to the controlled equipment or other property, additional precautions must be designed into the control system. Incorporate and maintain other devices, such as supervisory or alarm systems or safety or limit controls, intended to warn of or protect against failure or malfunction of the control. IMPORTANT : Utiliser ce P78 Series Control uniquement en tant que dispositif de contrôle de fonctionnement. Lorsqu'une défaillance ou un dysfonctionnement du contrôle risque de provoquer des blessures ou d'endommager l'équipement contrôlé ou un autre équipement, la conception du système de contrôle doit intégrer des dispositifs de protection supplémentaires. Veiller dans ce cas à intégrer de façon permanente d'autres dispositifs, tels que des systèmes de supervision ou d'alarme, ou des dispositifs de sécurité ou de limitation, ayant une fonction d'avertissement ou de protection en cas de défaillance ou de dysfonctionnement du contrôle. P78 control models with Single-Pole, Double-Throw (SPDT) switches allow users to install alarm devices or other control circuits. These controls are available in several pressure ranges and are compatible with most common refrigerants. They may also be used on air, water, and other non-corrosive fluid applications. Dual pressure P78MCA Type models with Manual Reset Lockout lock out when the Cut-out pressure is reached and do not automatically reset after the control has cut out, providing shutdown capability for unmonitored equipment. See Manual Reset Operation. Type 1 enclosures are standard on most models. Installation Dimensions See Figure 1 for control dimensions. These dimensions are nominal and subject to accepted manufacturing tolerances and application variables. Figure 1: Dimensions of P78 Dual Pressure Control with Type 1 Enclosure, in. (mm) Style 5 Connection Style 45 Connection P78 Series Controls for Dual Pressure Applications Installation Instructions 1

Mounting Risk of Property Damage. Mount the P78 Dual Pressure Control according to the instructions and guidelines included with the control. These instructions and guidelines are intended to reduce the risk of malfunction of the control and resulting property damage. Failure to follow these instructions and guidelines could cause the control to malfunction, resulting in property damage. Risque de dégâts matériels. Montez le contrôle P78 selon les instructions et directives fournies avec le contrôle. Ces instructions et directives sont destinées à réduire les risques de mauvais fonctionnement du contrôle et de dégâts matériels. Le nonrespect de ces instructions et directives pourrait provoquer un dysfonctionnement du contrôle et causer des dégâts matériels. IMPORTANT: When mounting the control to a flat horizontal surface, use the screws provided and Universal Mounting Bracket (sold separately) to avoid damaging internal components. Be careful not to distort or bend the control case when mounting the control to an uneven surface. Using other screws or bending the control case will void the warranty. Guidelines: Observe the following guidelines to mount the P78 dual pressure control: Mount the control in an accessible position, where the control and pressure-connection lines are not subject to damage. Mount the pressure control upright and level. Position the pressure-connection lines to allow drainage away from the control bellows. Locate pressure-tap points on the topside of the refrigerant lines to reduce the possibility of oil, liquids, or sediment accumulating in the bellows, which could cause control malfunction. Mount controls with Type 1 enclosures on horizontal or vertical flat surfaces. Vertical Surface: Use four M4 x 6 mm + d screws (1) through the inner holes (2) on the back of the control case when mounting directly to a flat vertical surface (3). The screws cannot be longer than 6 mm + d (where d refers to the thickness of mounting surface). (See Figure 2 and Table 1.) Horizontal Surface: Use four M4 x 6 mm screws provided (4) and Universal Mounting Bracket (5) (sold separately) when mounting to a flat horizontal surface. (See Figure 2 and Table 1). 2

Figure 2: Mounting the P78 High Pressure Control with Type 1 Enclosure Vertical Surface Horizontal Surface Table 1: Mounting P78 Dual Pressure Control Callout Description 1 Mounting Screws for Vertical Surface (4), M4 x 6 mm + d (screws cannot be longer than 6 mm + d) 2 Inner Mounting Holes (4) 3 Flat Vertical Mounting Surface 4 Mounting Screws for Horizontal Surface (4), M4 x 6 mm (included) 5 Universal Mounting Bracket (Part Number 271-51, sold separately) Wiring Risk of Electric Shock. Disconnect or isolate all power supplies before making electrical connections. More than one disconnection or isolation may be required to completely de-energize equipment. Contact with components carrying hazardous voltage can cause electric shock and may result in severe personal injury or death. Risque de décharge électrique. Débrancher ou isoler toute alimentation avant de réaliser un branchement électrique. Plusieurs isolations et débranchements sont peut-être nécessaires pour -couper entièrement l'alimentation de l'équipement. Tout contact avec des composants conducteurs de tensions dangereuses risque d'entraîner une décharge électrique et de provoquer des blessures graves, voire mortelles. IMPORTANT: Use copper conductors only. Make all wiring connections in accordance with local, national, and regional regulations. Do not exceed the control s electrical ratings. IMPORTANT: Use terminal screws furnished in the switch block. Using other terminal screws will void the warranty and may damage the switch. 3

P78 controls for dual pressure applications are available with a Single-Pole, Double-Throw (SPDT) switch. Check the label inside the control cover for the model number, switch action, and electrical rating. Check the wiring terminal designations on the control switch block, and see the following wiring diagram when wiring the control. (See Figure 3 and Table 2). Also see Technical Specifications. Figure 3: P78 Switch Wiring (SPDT) Table 2: P78 Switch Wiring (SPDT) LP/HP Description LP A-C opens on pressure decrease A-B closes simultaneously HP A-C opens on pressure increase A-D closes simultaneously Refrigerant Connections Risk of Environmental and Property Damage. Avoid sharp bends in the capillary tubes. Sharp bends can weaken or kink capillary tubes, which may result in refrigerant leaks or restrictions of flow. Risque de dommages environnementaux et dégâts matériels. Éviter de former des coudes serrés avec les tubes capillaires. Les coudes serrés peuvent affaiblir les tubes capillaires ou engendrer des pliures, ce qui risque de provoquer des fuites de réfrigérant ou d'en gêner l'écoulement. 4

Risk of Environmental and Property Damage. Coil and secure excess capillary tubing away from contact with sharp or abrasive objects or surfaces. Vibration or sharp or abrasive objects in contact with capillary tubes can cause damage that may result in refrigerant leaks, which may result in damage to the environment or property. Risque de dommages environnementaux et dégâts matériels. Enrouler et fixer l'excédent de tubes capillaires de manière à éviter tout contact avec des objets coupants ou des surfaces abrasives. Des vibrations ou des objets coupants ou abrasifs en contact avec les tubes capillaires risque d'endommager ceux-ci et d'occasionner des fuites de réfrigérant, susceptibles de provoquer des dommages environnementaux ou des dégâts matériels. IMPORTANT: If the control is installed on equipment that contains hazardous or regulated materials such as certain refrigerants or lubricants, you must comply with all standards and regulations governing the containment and handling of those materials. IMPORTANT: Do not apply more than 9 ft lb (12 N m) of torque to the flare nuts on pressure connection line fittings. Over-tightening or applying more than 9 ft lb (12 N m) of torque may cause seal failure and will void the warranty. P78 dual pressure controls with Style 5 connections are connected to the controlled equipment by a capillary. Capillaries are available from Johnson Controls, Inc. Refer to SEC99A, UltraCap Armored Capillary (LIT-1900131) for more information. Avoid severe pressure pulsation at high-side pressure connections. Install pressure connection to pressure-tap points away from the compressor, to minimize the effects of pressure pulsation from reciprocating compressors. IMPORTANT: After installing the control, evacuate pneumatic and pressure connection lines to remove air, moisture, and other contaminants in a manner consistent with applicable environmental regulations and standards. Setup and Adjustments Risk of Property Damage. Obtain and use the compressor manufacturer s net oil bearing pressure specifications. If necessary, reset the cut-out pressure difference to the manufacturer s specifications. Using improper pressure settings may damage the control, compressor, or other controlled equipment. Risque de dégâts matériels. Consulter et utiliser les spécifications de pression nette de palier à huile fournies par le fabricant du compresseur. Si nécessaire, réinitialiser la différence de pression d'ouverture sur les paramètres spécifiés par le fabricant. L'utilisation de paramètres de pression inappropriés risque d'endommager le dispositif de contrôle, le compresseur ou d'autres équipements contrôlés. 5

IMPORTANT: Use the pressure control settings recommended by the manufacturer of the controlled equipment. Do not exceed the pressure ratings of the controlled equipment or any of its components when checking pressure control operation or operating the controlled equipment. IMPORTANT: After mounting, wiring, and evacuating the control, attach a reliable set of gauges to the controlled equipment, and operate the equipment (at least) three cycles at the pressures necessary to verify control setpoints and proper equipment operation. IMPORTANT: Do not adjust pointers beyond the highest or lowest indicator marks on the control s pressure scale. Adjusting pointers beyond indicator marks may damage screw threads, may cause inaccurate control operation, and will void the warranty. Adjusting the P78 Dual Pressure Controls Use the following procedures for adjusting these controls. Refer to the product label inside the control cover for model number and switch action. Dual Pressure with Automatic Reset: Models with Automatic Reset have a scaleplate that displays the Cut-in and Differential setpoints for the low side (Item 1, Figure 4). The high side scaleplate of the P78 dual pressure control displays only the Cut-out setpoint (2). 1. Set the low side Cut-in setpoint by adjusting the range screw. 2. Turn the low side range screw (3) clockwise to raise the Cut-in setpoint. 3. Adjust the Cut-out setpoint by adjusting the differential screw (4). 4. Turn the differential screw clockwise to raise the Cut-out setpoint. 5. Set the high side Cut-out setpoint. 6. Turn the high side range screw (5) clockwise to raise the Cut-out setpoint. Note: Cut-out = Cut-in minus Differential. Dual Pressure with Manual Reset Lockout: Models with Manual Reset Lockout have a scaleplate that displays the low side Cut-in/Differential and high side Cut-out setpoints (Item 6, Figure 4). 1. Set the low side Cut-in setpoint by adjusting the range screw. 2. Turn the low side range screw (3) clockwise to raise the Cut-in setpoint. 3. Set the high side Cut-out setpoint. 4. Turn the high side range screw (5) clockwise to raise the Cut-out setpoint. 5. See Manual Reset Operation to restart controlled equipment (see Item 7). 6

Figure 4: Adjusting the P78 Dual Pressure Controls Automatic Reset Manual Reset Lockout Table 3: Adjusting P78 Dual Pressure Controls Callout Description 1 Low Side Range and Differential Scales 2 High Side Range Scale 3 Low Side Range Screw 4 Low Side Differential Screw 5 High Side Range Screw 6 Low Side Range Scale (only) 7 Reset Button 8 Pressure Connection 9 Adjustment Lock Plate (if applied) Manual Reset Operation Pressure controls with the Manual Reset option, lock out when they reach Cut-out pressure and must be manually reset by the user to restart the controlled equipment. The manual reset mechanism is trip-free and cannot be overridden by holding the Reset Button down. When a control requires a manual reset, first determine what caused the control to cut out, and allow the sensed pressure to fall at least 44 psi (3 bar) below the Cut-out pressure. Then press and release the Reset Button on the front of the control to restore normal operation of the controlled equipment (see Item 5, Figure 4). Technical Specifications Table 4: P78 Series Electrical Ratings UL60730 24 120 208 240 Primary Secondary Primary Secondary Primary Secondary Volts AC 50/60 Hz Contact Contact Contact Contact Contact Contact Horsepower 1.33 1 0.75 1 1 Full Load Amperes 16 7.2 9.2 7.6 8 8 Locked Rotor Amperes 96 43.2 55.2 45.6 48 48 Resistive Amperes 16/8 16 8 10 8 10 8 Pilot Duty VA 125/125 720 720 720 720 720 720 Note: The Primary Contact is A C; the Secondary Contacts are A B and A D. 7

Table 5: P78 Series Applications Information Description Product Switch Action Single-Pole, Double-Throw (SPDT) Pressure Connection 7/16-20 UNF for 1/4 (6 mm) flare nut. Ambient Storage Conditions Enclosure Dimensions (H x W x D) Approximate Shipping Weight Compliance Temperature: -40 to 140ºF (-40 to 60ºC) Humidity: 0 to 95% R.H. Non-condensing Type 1: Cast Aluminum Type 1 Enclosure: 4 x 3.5 x 2.5 in. (101 x 89 x 64 mm) Individual Pack: (Type 1 Enclosure): 1.55 lbs (0.7 kg) Bulk Pack: (Type 1 Enclosure in multiples of 35 controls): 40 lbs (18.1 kg) culus Listed; UL 60730, File SA516 Table 6: UL Conformity Declaration Information Information Description Purpose of Control Pressure Operating Control: Automatic reset controls Pressure Cut Out: Manual reset controls Construction of Control Electromechanical Number of Cycles Automatic 30,000 Cycles Manual Reset 6,000 Cycles Method of Mounting Control Independently-mounted control Type 1 or Type 2 Action Automatic: Type 1; Type 1.C (Micro-Interruption) Manual Reset: Type 2 Pollution Degree Category 3 Heat and Fire Resistance Category N/A Rated Impulse Voltage 4,000 V Ball Pressure Temperature N/A Field Wiring Rating 194 F (90 C) Maximum Working Pressure LP: 290 psi (20 bar) HP: 479 psi (33 bar) Cover Screw Torque Requirements Tighten Enclosure Screws to: 10-12 in lb (1.1-1.4 N m) Instruction The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. European Single Point of Contact: NA/SA Single Point of Contact: APAC Single Point of Contact: JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA JOHNSON CONTROLS C/O CONTROLS PRODUCT MANAGEMENT NO. 22 BLOCK D NEW DISTRICT WUXI JIANGSU PROVINCE 214142 CHINA Building Technologies & Solutions 507 E. Michigan Street, Milwaukee, WI 53202 Johnson Controls and PENN are registered trademarks of Johnson Controls in the United States of America and/or other countries. All other trademarks used herein are the property of their respective owners. Copyright 2016 by Johnson Controls. All rights reserved. Published in U.S.A. 8 www.johnsoncontrols.com